Loading...
HomeMy WebLinkAboutGAF Shingle NOA#19-0312.04 MIAMI-DADE COUNTY MIAMI• PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economv GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline HD®,Timberline®Natural Shadow®,Timberline®NS,Timberline®American Harvest®,Timberline®AH,Timberline®HDZTM,Timberline®CS and Fortitude®Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 16-0811.11 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino NOA No.: 19-0312.04 MAMI.OAD;COUNTY Expiration Date: 02/21/22 Approval Date: 01/09/20 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves GAF Timberline HD®,Timberline®Natural Shadow®,Timberline NS®,Timberline American® Harvest®,Timberline AH®,Timberline®HDZTM,Timberline CS®and Fortitude TM Shingles as manufactured by GAF as described in this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline HD® 13 '/a,x 39 3/g" TAS 110 Fiberglass reinforced heavy weight asphalt roof Manufacturing shingle,with a laminate profile Locations#1,2,3,4,5,6,7 GAF Timberline®Natural 13 '/4"x 39 3/g" TAS 110 Fiberglass reinforced heavy weight asphalt roof Shadow®and Timberline'NS shingle,with a laminate profile Manufacturing Locations#1,2,3,4,5,6,7 GAF Timberline®American 13 '/a.x 39 3/g" TAS 110 Fiberglass reinforced heavy weight asphalt roof Harvest® shingle,with a laminate profile Manufacturing Locations#2,4,6,9 GAF Timberline®AH 13 '/4„x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof Manufacturing shingle,with a laminate profile Locations#2, 4, 6, 9 GAF Timberline®HDZTM' 13 '/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof Manufacturing shingle,with a laminate profile Locations#1,2,3,4,5,6,7,8,9 GAF Fortitude® 13 '/a,x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof Manufacturing shingle,with a laminate profile Location#4 GAF Timberline'CS 13 '/a"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof Manufacturing shingle,with a laminate profile Location #9 NOA No.: 19-0312.04 MAMI•DAD`COUNTY Expiration Date: 02/21/22 Approval Date: 01/09/20 Page 2 of 7 MANUFACTURING LOCATION 1. Tampa,FL 2. Michigan City,IN 3. Baltimore,MD 4. Myerstown,PA 5. Ennis,TX 6. Tuscaloosa,AL 7. Dallas, TX 8. Shafter, CA 9. Fontana, CA NOA No.: 19-0312.04 Miarai•oao`COUNrr Expiration Date: 02/21/22 Approval Date: 01/09/20 Page 3 of 7 EVIDENCE SUBMITTED Test Ame Test Identifier Test Name/Report Date Underwriters Laboratories, LLC ASTM D3462 4788932264 12/13/19 Underwriters Laboratories,LLC ASTM D3462 4788717529 01/31/19 Underwriters Laboratories,LLC ASTM D3462 4787344101 07/25/16 Underwriters Laboratories,Inc. ASTM D3462 11CA48924 10/22/11 Underwriters Laboratories,Inc ASTM D3462 IOCA21994 04/22/11 Underwriters Laboratories,Inc ASTM D3462 IOCA28717 07/26/11 Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories,Inc. ASTM D3462 06NK05159 08/09/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05 Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02 Underwriters Laboratories,Inc.Center for ASTM D3462ASTM 03NK26444257989 10/17/03 Applied Engineering D3462 05/13/97 Underwriters Laboratories,LLC TAS 107 4789225984 11/1/19 Underwriters Laboratories,LLC TAS 107 4788717529 01/31/19 Underwriters Laboratories,Inc. TAS 107 01NK45803 04/13/94 Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05 Underwriters Laboratories,Inc. TAS 107 02NK41811 11/11/02 Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories,Inc. TAS 107 04CA13850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies,Inc. TAS 100 GAF-912-02-01 12/17/18 PRI Asphalt Technologies,Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologies,Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt Technologies,Inc. TAS 100 GAF-116-02-02 03/23/06 PRI Asphalt Technologies,Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELK-085-02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-08 7-02-01 10/21/02 ELK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10/09/03 NOA No.: 19-0312.04 MAMI.OWD;COUNTY Expiration Date: 02/21/22 Approval Date: 01/09/20 Page 4 of 7 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail'B', attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 19-0312.04 MIAMMAD`COUNTY Expiration Date: 02/21/22 Approval Date: 01/09/20 Page 5 of 7 DETAIL A COURSE LAYOUT DECK FULL 5th 17" OFF 4th 11" OFF 3rd 6" OFF 2nd FULL 1st 5-5/8" Exposure NOA No.: 19-0312.04 MIAMI•DAD;COUNTY Expiration Date: 02/21/22 Approval Date: 01/09/20 Page 6 of 7 DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN FOR TIMBERLINE HD® TIMBERLINE® NATURAL SHADOW® AND TIMBERLINE®NS Il 39-3/8" (,m} �— 14-1/2"- 17-1/2" 14-1/2"- 17-1/2" (368-445mm) (368-445mm) aifguide line 6-1/2" 9-1/2" 6-1/2" 9-1/2" 5 1(155-241 (155-241-) - - -1/4 146mm-159mm) v2 - - -13337mm r'- /2" from bottom of shingle 13-64 7 elf seal adhesive on back ENHANCED NAILING PATTERN - six nails per shingle* *required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6" (152mm) from bottom of of shingle, above the cut outs; as shown. Nails must not be exposed. OVERALL DIMENSIONS AND NAILING PATTERN FOR TIMBERLINE®HDZTM, TIMBERLINE®CS, TIMBERLINEOAH,AND FORTITUDE® 39-3f8" 1 m) 14-112'-17-117 366 mm-445 mm 14-11t'-17-112' 3%mm-445mm 6-112'-9-1/1'(165mm-241 mm) 6-112'-9-1/1(166mm-241 mm) (13mm-64mm) 1Z-2-1/2'(13mm-64mm) 13-1/4" 337mm = { } TARGET --- ----- - ----- ----- --- -- ---------- -------- ----- -------- ----- --- --- ----- --- NAIL ZONE 5-13116'-6-114' 5-13116'-7-5/8" (148mm-159 mm) (.148 mm-194 mm) For Mansard Raafs — 1 0 END OF THIS ACCEPTANCE NOA No.: 19-0312.04 MIAMI•DAD;COUNTY Expiration Date: 02/21/22 Approval Date: 01/09/20 Page 7 of 7