HomeMy WebLinkAboutProducts Review; Oceanview Aluminium Vertical Mullion (Impact)NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 4. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. 5. DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL. 6. SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. WINDOWS MUST BE MANUFACTURED BY VIWINCO INC. 7. _DESIGN PRESSURE OF MULLED UNIT. SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNIT. B. UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS ANCHORED AS SHOWN HEREIN. 9. MULLION VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING TO THIS DOCUMENT. �-fgzs'L� REVISIONS I REV I DESCRIPTION I DATE I APPROVEO ANCHORING NOTES: 1. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 2. FOR ANCHORING INTO CONCRETE USE 3/16" TAPCON WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 4. 3. FOR ANCHORING INTO METAL STRUCTURE USE #8 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 4. FOR ATTACHING WINDOW UNITS TO MULLION USE #8 SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS IN ACCORDANCE WITH WINDOW ANCHORING SCHEDULE AS SHOWN IN WINDOW SEPARATE APPROVAL. 5. ALL FASTENERS TO BE CORROSION RESISTANT. 6. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 (OR GREATER). D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063—T5 FU=30KSI 1/8" THICK MINIMUM 7. TO ATTACH CLIP TO MULLION USE (2) #8 x 3/4" SELF DRILLING SCREWS PER CUP. 8. ATTACH MULLION TO WINDOW FRAME USING #8 X 3/4" SELF DRILLING SCREWS LOCATED 1" FROM EACH END AND 8" MAX. O.C. THEREAFTER. 0 D " �I M�� ®o 0 rrp ® SIGNED:0310212016 VIWINCO, INC s �lit. u,L�o����� - � MORGANTOWN BUSINESS PARK P.O. BOX 499 �® r TABLE OF CONTENTS MORGANTOWN, PA 19543 v \CENs'9J'� SHEET NO. DESCRIPTION OCEAN VIEW ALUMINUM VERTICAL MULLION *• 0 61 Tk IMPACT 0 W ® 1 NOTES NOTES �� ate S E :OF . fit►: TAT �v z 2 - 3 APPROVED CONFIGURATIONS AND CHARTS DRAWN: DWG NO. REV �iD�'�••'O[pR10Q:'�C� 4 — 6 INSTALLATION DETAILS N.G. 08 2 84 7 COMPONENTS NTS DATE 03/1/16 s01 OF 7 120 1/2" COMBINED WIDTH F_ W1 W2 120" // WINDOW ✓/ FRAME HEIGHT ININDOIA WINDO11 (MULLION SPAN) W1 ---I I- W2 120 1/2" COMBINED WIDTH 120 1/2" T OMBINED WIDTH W 1 --{ W2 FRAME / HEIGHT WINDOW WINDOW (MULLION SPAN) F_ 120 1/2" COMBINED WIDTH /W1 � r---/ W2 J J WINDOW WINDO // WIN DOW 120 1/2" T OMBINED WIDTH W1 -I[- W2 / 'WINDOW WINDOWW /1 / W1-IF-W2 120 1/2" COMBINED WIDTH 120 1/2" COMBINED WIDTH IINDOW W1 -{[- W2 WINDOW Design pressure rating (pso Mullion span (in) Tributary width (in) 24.00 30.00 36.00 4200 48.00 54.00 60.00 24.00 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30.00 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36.00 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42.00 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48.00 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54.00 120.0 120.0 120.0 119.8 115.3 113.9 113.9 60.00 120.0 120.0 109.8 101.3 96.1 93.2 92.2 66.00 120.0 108.5 96.1 87.8 82.3 78.8 76.8 72.00 115.3 97.1 85.4 77.5 71.0 66.2 62.9 78.00 104.8 86.7 74.0 65.2 59.0 54.5 51.3 84.00 85.0 69.3 59.1 52.1 47.1 43.5 40.8 90.00 68.8 56.0 47.6 41.8 37.6 34.5 32.2 96.00 56.5 45.9 38.9 34.1 30.5 27.9 25.9 10200 47.0 38.1 322 28.1 25.2 22.9 21.2 108.00 39.5 31.9 27.0 23.5 21.0 19.1 17.6 114.00 .5 27.1 1 228 19.9 17.7 16.0 - 120.00 1 28.7 1 23.2 1 19.5 1 16.9 1 15.1 - - IMPACT RATED UP TO WIND ZONE 3 F_ 120 1/2" COMBINED WIDTH `W1-{I--W2 ` a WINDOW /WINnn` 4 /WINDOW APPROVED CONFIGURATIONS I W1---�1 -W2 120 1/2" COMBINED WIDTH REVISIONS I REV I DESCRIPRON I DATE I APPROVED A DESIGN PRESSURE TABLE INSTRUCTIONS: 1. DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2. DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3. LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH �E�] SIGNED: 03102120 VIWINCO, INC ��01%11111/11/ MORGANTOWN BUSINESS PAR P.O. BOX 499 `�•� EN ,9 O' '/ v\ d OCEAN VIEW ALUMINUM VERTICAL MULLION =p6} IMPACT ((�� APPROVED CONFIGURATIONS S0 TAT OF N.G. I 08-02884 SCALE NTS - 03/1/16 ISHEL72 OF 7 REV TPo HI WI HI COMBINED WIDTH Wt � �-^ W2 T-- NSOM IGHT TRANSOM TRANSOM TRANSOM FRAI HEIG (MULL JDOW WINDOW WINDOW WINDOW SPAT IGHT L W, -I1- W2 120 1/2" W CONFIGURATION E IT ON 1) Maximum design pressure chart (psi) Units with 18" transom Height (in) Window Transom Tributary width (in) 24.00 130.00 136.00 4200 14&00 154.00, 60.00 36.00 18.00 150.0 136.8 119.0 106.0 95.5 1 86.9 79.7 42.00 18.00 128.9 107.3 93.2 83.3 75.7 69.3 64.0 48.00 18.00 103.8 86.2 74.7 66.6 60.7 56.0 52.0 54.00 18.00 85.2 70.6 61.0 54.3 49.3 45.6 42.6 60.00 18.00 71.1 58.8 50.7 45.0 - 40.8 37.7 35.2 66.00 18.00 60.2 49.7 42.8 37.9 34.3 31.6 29.5 7200 18.00 51.6 42.5 36.5 32.3 29.2 26.8 25.0 78.00 1 18.00 44.7 36.8 31.5 27.8 '25.1 23.0 21.4 84.00 . 18.001 38.7 1 31.8 1 27.3 1 24.1 1 21.8 20.0 18.5 IMMAUJI KAMM UY I U WIKU LUNG J Maximum design pressure chart (ps0 Units with 24' hansom Height (in) Window Transom Tributary width (in) 24.00 30.00 136.00 42.00 48.00 54.00 60.00 36.00 24.00 132.7 110.2 1 95.2 84.2 75.4 68.3 62.4 4200 . 24.00 107.2 .88.8 1 76.6 67.9 61.2 55.7 51.1 48.00 24.00 88.2 72.9 1 62.8 55.5 50.2 46.0 42.4 60.00 24.00 62.4 51.4 44.1 38.9 35.1 32.1- 29.8 66.00 24.00 53.5 44.0 37.7 33.2 29.9 27.4 25.4 72.00 24.00 46.3 38.0 3um 23.5 21.8 L00 24.00 40.4 33.2 220.4 18.9 84.00 24.00 33.6 27.6 217.0' 15.7 Maximum design pressure chart (pso Units with 30' transom Height (in) Window Transom Tributary width (in) 24.00 130.00 36.00 4200 48.00 54.00 60.00 36.00 30.00 108.9 90.3 77.8 68.6 61.4 55.5 50.6 4200 30.00 90.0 74.4 64.0 56.5 50.7 46.0 42.1 48.00 30.00 75.5 62.2 53.4 47.1 424 38.6 35.5 54.00 30.00 64.1 52.7 45.2 39.8 35.7 32.6 30.1 60.00 30.00 55.0 45.2 38.6 34.0 30.5 27.8 25.7 .39.1- 33.4 29.3 26.3 24.0 22.1 34.1 29.1 25.5 22.9 20.8 , 19.2 W M29.4 28.6 24.421.3 19.1 17.4 16.0 24.0 20.4 17.9 16.0 - IMrAGI KAI UUY IU WINULUIMJ Maximum design pressure chart (pst) Units with 36' transom Height (in) Window Transom Tributary width (in) 24.00 30.00 36.00 4200 4&00 1 54.00. 60.00 36.00 1 36.00 90.6 74.9 64.5 56.9 50.9 1 46.0 42.0 42.00 36.00 76.4 62.9 54.0 47.7 42.8 38.8 35.4 48.00 36.00 65.1 53.5 45.8 40.4 36.2 32.9 30.2 54.00 36.00 56.0 46.0 39.3 34.6 31.0 28.2 25.9 60.00 36.00 48.6 39.8 34.0 29.9 26.8 24.3 22.4 66.00 36.00 42.5 34.8 29.7 26.1 23.3 21.2 19.5 7200 36.00 36.2 29.5 21.1 21.9 19.5 17.7 16.3 78.00 36.00 30.4 24.7 21.0 1 18.3 16.4 84.001 36.00 1 25.7 1 20.9 1 17.8 1 15.5 1 - IIW AGI KA I MU Ur I U VVINU L UfV=J REVISIONS REV DESCRIMON DATE I APPROVED DESIGN PRESSURE TABLE INSTRUCTIONS: 1. DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2. DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3. LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH - W1 + W2 2 VIWINCO, INC BOX 49 MORGANTOWN, PA 19543 OCEAN VIEW ALUMINUM VERTICAL MULLION IMPACT APPROVED CONFIGURATIONS DRAWN: DWG NO. N.G. 1 08-02884 'CALE NTS I DATE 03/1/16 SHEE 3 OF 7 SIGNED: 0310212016 REVISIONS MULLION COVER WINDOW FRAME aEv oFscRlPnaN on�E APPROVED REFERENCE ONLY ` MULLION � _ - � O CLIP #8 SELF DRILLING SCREW SEE ANCHORING NOTE 6 SHEET 1 3" MAX 3" MAX 4" MAX 4" MAX 3" MAX 3" MAX 1 1MIN EMBEEDD MENT 7/16" MIN WOOD FRAMING CUP EDGE DISTANCE OR 2X BUCK BY OTHERS 4 #8 WOOD 1 1/4" MIN SCREWEMBEDMENT 0 1/4" MAX SHIM SPACE 7/16" MIN EDGE DISTANCE l is = ! #8 WOOD / SCREW MULLION INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK SUBSTRATE HEAD SHOWN, SILL SIMILAR SIGNED: 0310212016 IO, INC MORGANTOWN BUSINESS PARK P.O. BOX 499 `�\\J\5+1R II LJd't191i� MORGANTOWN, PA 19543=�r••y�6ENs�,,.�� OCEAN VIEW ALUMINUM VERTICAL MULLION tk• 0, IMPACT INSTALLATION DETAILS �TAT � DRAWN: DWG ND. REv �iFS'O[ORID; G\$\ SS. NTS °A� 03/1/16 sHEE4 7 ?iSj NAL�E ��`� _ MULLION COVER WINDOW FRAME MULLION REFERENCE ONLY CLIP J #8 SELF DRILLING SCREW SEE ANCHORING NOTE 6 SHEET 1 MULLION INSTALLATION DETAIL METAL STRUCTURE INSTALLATION HEAD SHOWN, SILL SIMILAR REVISIONS DESCRIPRON DATE APPROVED 5/8" MIN #8 SELF EDGE DISTANCE DRILLING SCREW 1/4" MAX SHIM SPACE 7/16" MIN EDGE DISTANCE #8 SMS OR SELF DRILLING SCREW METAL STRUCTURE BY OTHERS SIGNED: 0310212016 INC lR I r�ro���i,, MORGANTOWN BUSINESS��PARK P.O. BOX 499 MORGANTOWN, PA 19543 �\�s we4�6ENs+.'9J+�� _ *1 p, 61261 V r OCEAN VIEW ALUMINUM VERTICAL MULLION IMPACT INSTALLATION DETAILS �70. TAT OF •r�; '�'c.�'c[QjZVDa. \\� DRAWN: DWG N0. REV 08 o�T8s4oF ��ONAIIE GxN "LE NTS °ATE 03/1 /16 7 MULLION COVER WINDOW F REVISIONS MULLION REFERENCE ONLY REV DESCRIPRON 11—I o 2 1/2" MIN \ CLIP (%8 SELF DRILLING SCREW EDGE DISTANCE SEE ANCHORING NOTE 6 SHEET 1 1 1/4" MIN 3" MAX 3" MAX 4" MAX 4" MAX 3" MAX 3" MAX EMBEDMENT BY OTHERS CONCRETES MASONRY CLIP .. ,-..:....... ;. a,...• . n :.. � .,. •• • ' 1 1/4" MIN EMBEDMENT MULLION INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION HEAD SHOWN, SILL SIMILAR #8 WOOD J SCREW 1/4" MAX SHIM �j SPACE Lf Lr MIN EDGEGE DISTANCE 3/16" TAPCON VIWINCO, INC MORGANTOWN BUSINESS PARK P.O. BOX 499 MORGANTOWN, PA 19543 OCEAN VIEW ALUMINUM VERTICAL MULLION IMPACT INSTALLATION DETAILS DRAWN: DWG NO. REV N.G. 08-02884 — 'CA'E NTS °ATE 03/1/16 IsHffT6 OF 7 DATE I APPROVED SIGNED: 0310212016 *• oy,61261 •9t;, STATE OF �,.% w 1 7,6" r 7/16" 13/16" r —{ �1/2" I 3 1/16" p 15/16" a DOO 3 8" -r r L� I 77 CLIP DETAIL MULLION PART 2411-A GALVANIZED STEEL .070'THICK ALUMINUM 6105-T5 MULLION COVER MOMENT OF INERTIA:.4048 INA4 PVC .050' THICK SECTION MODULUS:.2614 INA3 FRAME WINDOW ',REFERENCE ONLY WINDOW TO MULLION ATTACHMENT DETAIL COVER WINDOW ANCHORS SEE ANCHORING NOTE 4 SHEET 1 #8 X 3/4" SELF TAPPING SCREWS 1" FROM EACH END 8" MAX O.C. SEE ANCHORING NOTE 8 SHEET 1 MULLION REVISIONS DESCRIPDON DATE APPROVED SIGNED: 0310212016 I ILO��ii�� MORGANTOWN BUSINESS PARK P.O. BOX 499 `���5`R MORGANTOWN, PA 19543 `ter •�.�CENSE`9`n� *• 0G'm OCEAN VIEW ALUMINUM VERTICAL MULLION IMPACT _COMPONENTS �y0.• TAT �0���.��ORIOP� DRAWN: DWG NO. REV N.G. 08-02884 - f7NA`��G��\ �/ �� SCALE °ATE --7 NTS 03/1/16 OF 7