Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Evaluation Report; SOPREMA Roof Underlayments for use in FBC HVHZ Jurisdictions
NEW I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION SOPREMA, Inc. Evaluation Report 3m-SOPC-2I-FBCER.A 1640 rue Haggerty FL2569-R22'(HVHZ) Drummondville, Quebec J2C 5P8 Canada Date of Issuance: 04/19/2021 (819)478-2400 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State.of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 7eh Edition (2020) Florida Building Code, High Velocity Hurricane Zone sections noted herein. DESCRIPTION: SOPREMA Roof Underlayments for use in FBC HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This' Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC,.LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc: Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall. be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through .7. Prepared by: olt�_ai Ma Robert J.M. Nieminen, P.E. �'3�:'Sn%z:Oft a� -' slii_ = ? f Florida Registration No. 59166, Florida DCAANE1983 ,•'� .,.�,..« The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/19/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing,products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, not will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO EfC, LLC ONEMO I etc. ROOFING COMPONENT EVALUATION: Product Category: Sub -Category: U n d erl ayme nt Compliance Statement: SOPREMA Roof Underlayments, as produced by SOPREMA, Inc., have demonstrated compliance with the following sections of the 7" Edition (2020) Florida Building Code, High Velocity Hurricane Zone through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARDS:2. Section Property Standard Year TAS 110 Material standard ASTM D1970 2015 TAS 110 Material standard ASTM D4601 2012 TAS 110 Material standard TAS 103 2020 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: EnftY Examination Reference Date ERD (TST6049) TAS 103 (MS) S43530.02.14-1-R1 02/21/2014 ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (OH) S44870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (MS) S44870.04.14-4 04/10/2014 ERD (TST6049) ASTM D1970 (OH) S40540.10.14 10/31/2014 ERD (TST6049) Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) ASTM D4798 SOPC-SC8520.04.14 04/27/2015 NEMO (TST6049) ASTM D1970 / TAS 110 (QC) SOPC-SC8970.08.15-RI 04/25/2018 NEMO (TST6049) Tile Slippage 4S-SOPC-18-002.09.18 09/21/2018 NEMO (TST6049) ASTM D4601(MS) 4q-SOP-I9-SSMBB-01.A 03/11/2019 MEMO (TST6049) ASTM D4601(OH) 44-SOP-I9-SSMBB-01.8 03/11/2019 NEMO (TST6049) ASTM D4798/D1970 (OH & MS) 4S-SOPC-18-002.05.19.A 05/31/2019 NEMO (TST6049) Tensile Adhesion / Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-20-SSUDL-01.A 01/07/2021 NEMO (TST6049) ASTM D1970 (MS) 4j-SOPC-2I-SSUDL-01.A 04/19/2021 PRI (TST5878) ASTM D1976 (MS) SOP-064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH.PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control MLA File No. R16814 12/10/2015 UL, LLC (QUA9625) Quality Control MLA File No. R27605 05/08/2019 UL, LLC (QUA9625) Quality Control Service Confirmation 06/29/2020 UL, LLC (QUA9625) Quality Control Florida BCIS Current M 4.1 4.2 4.3 4.4 •.••DESCRIPTION: Product Material Standard Plant(s) Description LASTOBOND TU HT ASTM D1970 and Gulfport, MS self:adhering, non -woven polyester fabric surfaced, SBS TAS 103 modified bitumen roof underlayment Tri-BuiltS/A HTTU ASTM D1970'and Gulfport, MS self -adhering, non -woven polyester fabric surfaced, SBS Underlayment TAS 103 modified bitumen roof underlayment LASTOBOND Shield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch RESISTO SA SMOOTH PLY40 ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment NEMO ETC, LLC. Evaluation Report 3m-SOPC-2I-FBCER.A Certificate ofAutharkation #32455 7-,EDITION (2020) FBC HVHZ EVALUATION FL2569-1122 (HVHZ) SOPREMA Roof Underlayments Revision 0: 04/19/2021 Page 2 of 7 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 ONEMOletc. PRODUCT Product Material Standard Plants), Description, LASTOBOND Shield HT ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment LASTOBOND Pro HT-N ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch LASTQa0N0ProHT-- AST LD1970 fi Drummondville qC self-adheri'ng;,woven olyetfiylenesurfaced high'7 ,;temperature; SBS modified bitumenroofiunderlayment j EnviroShield ASTM D1970 Drummondville, QC self=adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment LASTOBOND Eco ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH LASTOBOND Smooth Seal HT ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Wadsworth, OH modified bitumen roof underlayment Tri-Built Smooth HT S/A ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Underlayment Wadsworth, OH modified bitumen roof underlayment PrimeSource Grip -Rite ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Smooth Seal HT Wadsworth, OH modified bitumen roof underlayment RESISTO LB1236 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH TRI-BUILT Sand-R SA Shingle ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Underlayment Gulfport, MS modified bitumen roof underlayment Wadsworth, OH PrimeSource Grip -Rite Eave ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS & Valley Protector Gulfport, MS modified bitumen roof underlayment Wadsworth, OH SRS TopShield ICE & WATER ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS DEFENDER Gulfport, MS modified bitumen roof underlayment Wadsworth, OH RESISTO LB1244 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH MODIFIED SOPRA-G ASTM D4601, Type II Gulfport, MS Fiberglass reinforced, SBS modified asphaltic base sheet Wadsworth, OH 5.1 This is a Building Code Evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is notfor use in FBC Non -High Velocity Hurricane Zone jurisdictions (i.e., outside of Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. NEMO ETC, I.I.C. Evaluation Report 3m-SOPC-2I-FBCER.A Cerra lcate ofAuthorizatlon #32455 7- EDITION (2020) FBC HVHZ EVALUATION FL2569-R22 (HVHZ) SOPREMA Roof Underlayments Revision 0: 04/19/2021 Page 3 of 7 ONEMOjetc. 5.5 SOPREMA Roof Undeclayments.rhay be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be.made to the Authority Having Jurisdiction for approval based on this evaluation combined.with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1 ROOF COVER OPTIONS FBCSection: TAS 110(110), RAS115 TAS 110(S21), RAS 118,129 & 220 RAS 133 TAS 120(S11) RAS 130 Clay and Concrete Tile Underlayment Y Asphalt Shingles Metal Slate or Slate- Type Shingles Wood Mechanical Adhesive- Attach Set , LASTOBOND TU HT, Tri-Built S/A HT TU Yes Yes Underlayment Yes See 5.6.1 Yes Yes Yes LASTOBOND Shield, Pro HT-N, RESISTO SA SMOOTH PLY 40 Yes No No Yes Yes Yes LASTOBOND Shield HT, Pro HT-S Yes No No Yes Yes Yes Enviro5hield Yes No No Yes Yes Yes LASTOBOND ECO, RESISTO LB1236, TRI- BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, Yes No No No Yes Yes TopShield ICE & WATER DEFENDER, RESISTO LB1244 LASTOBOND Smooth Seal HT Tri-Built Smooth HT S/A Underlayment, Grip -Rite Yes No No Yes Yes Yes Smooth Seal HT 5.6.1 Adhesive -set the is limited to use of the following underlayment / tile -adhesive combinations. •. ;,,..;jABLEJLA:ALLOWAEfLg NDERLAYMENT�TILE-ADHESIVEC0 BINATIUNS1 Underlayment Adhesive Florida ProductApproval LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment Dupont `Tile Bond'" Roof Tile Adhesive' FL22525 ICP Adhesives and Sealants "Polyset® AH-160" NOA 20-1124.07 5.7 Allowable Substrates: ' ;. ,-TABLE 2: SUBSTRATE OPTIONS' FOR ADHERED UNDERLAYMENTS Underlayment Application Substrates (designed to meet wind loads for project) Type Primer Material(s) LASTOBOND Shield, LASTOBOND Pro HT-N, Deck ASTM D41 structural concrete RESISTO SA SMOOTH PLY'46, LASTOBOND Shield HT LASTOBOND Pro HT-S, Insulation (Optional) Elastocol Stick Zero Dens Deck -Prime or SECUROCK Enviro5hield, LASTOBOND TU HT, .Tri-BuiltS/A Gypsum -Fiber Roof Board HTTU Underlayment, LASTOBOND ECO, self- RESISTO LB1236, TRI-BUILT Sand-R SA Shingle adhering Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER Base Sheet (Optional) Elastocol Stick Zero ASTM D226, Type II felt DEFENDER, RESISTO LB1244, LASTOBOND Smooth Seal HT, Tri-Built Smooth HTS/A Underlayment or Grip -Rite Smooth Seal HT I Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approvol for Overturning Moment Resistance Performance. MEMO ETC, LLC. Evaluation Report 3m-SOPC.21-FBCER.A CPrdficate of Authorization #32455 77N EDITION (2020) FBC HVHZ EVALUATION FL2569-R22 (HVHZ) SOPREMA Roof Underlayments Revision 0: 04/19/2021 Page 4 of 7 ONEMOletc. TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Material(s) LASTOBOND TU HT; Tri-Built S/A HT TU Underlayment, RESISTO LB1236, TRI-BUILT self- Existing Existing sand -surfaced, glass -fiber Sand-R SA Shingle Underlayment, Grip -Rite adhering substrate RESISTO EXTERIOR PRIMER surfaced, mineral -surfaced or Eave & Valley Protector orTopShield ICE & film -surfaced roof underlayment*' WATER DEFENDER * Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment RES15TO LB1236, TRI-BUILTSand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector orTopShield ICE & WATER DEFENDER self adhering underlayments, contact RESISTO technical support. 5.8 Attachment Limitations: Refer to Section 6 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Prepared Roof Cover Maximum Underlayment Installation Type Exposure (days) LASTOBOND Eco, RESISTO LB1236, TRI-BUILTSand-R SAShingle Underlayment, Grip -Rite Mechanically attached 30 Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244 LASTOBOND Shield, I ASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT Mechanically attached 90 S/A Underlayment or Grip -Rite Smooth Seal HT LASTOBOND TU HT or Tri-Built S/A HTTU Underlayment Mechanically attached or adhesive -set tile roof system 180 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 30-tile stack 6:12 LASTOBOND TU HT, Tri- Built S/A HT TU Underlayment Lugged Max.10-tile stack 5:12 Lugged Double -tile stacking method, as shown below 6:12 NEMO ETC, LLC. Evaluation Report 3m-SOPC-2I-FBCER.A Certificate afAuthorization #32455 7- EDITION (2020) FBC HVHZ EVALUATION FL2569-R22 (HVHZ) SOPREMA Roof Underlayments Revision 0: 04/19/2021 Page 5 of 7 ONEMID-Jetc. 6.1 SOPREMA Roof Underlayments shall be installed in accordance with. SOPREMA published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panel's, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 6.3.1 Approved Assemblies: Deck Type 1: Wood, Non -Insulated Deck Description: Min.19/32" plywood or wood plank System Type E: Base sheet.mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt -or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and Table 4 for tile stagging limitations. 6.3.2 1 Deck Type 1: Wood,Non-Insulated Deck Description: Min.19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT, self - adhering. Surfacing: FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate -type shingles, wood shakes or wood shingles. 6.3.3 I Deck Type 1: Wood, Non -Insulated Deck Description: Min.19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND ECO, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244, self -adhering. Surfacing: FBC HVHZ Approved asphalt shingles, slate, slate -type shingles, wood shakes or wood shingles. NEMO'ETC. LLC. Evaluation Report 3m-SOPC-21: FBcER.A Cerrlflcare ofAurharkation #32455 7- EDITION(2020) FBC HVHZ EVALUATION F1,2569-02 (HVHZ) SOPREMA Roof Underlayments Revision 0: 04/19/2021 Page 6 of 7 ONEMOIetc. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: I Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified' material standards. UL LLC—QUA9625; (414) 248-6409; Karen.buchmann@ul.com - END OF EVALUATION REPORT - NEMO ETC, LLC. Evaluation Report 3m-SOPC-2I-FBCER.A Certificate of Authorization #32455 7- EDITION (2620) FBC HVHZ EVAWATION F1.2569-I122 (HVHZ) SOPREMA Roof Underlayments Revision 0: 04/19/2021 Page 7 of 7