Loading...
HomeMy WebLinkAboutWITHERS- ENERGY CALC FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WITHERS RESIDENCE Builder Name: JWN BUILDERS,LLC. Street: LOT 1106 NETTLES ISLAND Permit Office: ST LUCIE COUNTY City,State,Zip: JENSEN BEACH , FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Types(1970.0 sgft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Polystyrene Bead AggrER=0.0 1970.00 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 11.Ceiling Types (1673.0 sgft.) Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=19.0 1673.00 ft2 6. Conditioned floor area above grade(ft2) 1673 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 7. Windows(279.7 sqft.) Description Area 12.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:AHU CLST 6 140 a. U-Factor: Sgl,U=0.65 279.67 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 29.4 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 1.644 ft. 14.Heating systems kBtu/ Efficiency Area Weighted Average SHGC: 0.250 a.Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15.Hot water systems SHGC(AVG): N/A a.Electric Tankless Cap: 1 gallons 9. Floor Types (1673.0 sgft.) Insulation Area EF:0.990 a.Slab-On-Grade Edge Insulation R=0.0 861.00 ft2 b. Conservation features b.Raised Floor R=0.0 559.00 ft2 None c.other(see details) R= 253.00 ft2 16.Credits None Glass/Floor Area: 0.167 Total Proposed Modified Loads: 63.95 PASS Total Baseline Loads: 64.04 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this fiV Code. calculation indicates compliance G'0D with the Florida Energy Code. PREPARED BY: W&R, Before construction is completed DATE: 6-10-2021 this building will be inspected for �.1" Srgl, compliance with Section 553.908 1 hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). 6/10/2021 8:35 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WITHERS RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1673 Lot# Owner Name: Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: JW N BUILDERS,LLC. Rotate Angle: 0 Street: LOT 1106 NETTLES IS Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: JENSEN BEACH , Family Type: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1673 13384 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 LIVING/DINING RM 407 3256 No 0 1 Yes Yes Yes 2 PANTRY 20 160 No 0 1 No Yes Yes 3 BATH 60 480 No 0 1 Yes Yes Yes 4 WIC 70 560 No 0 1 Yes Yes Yes 5 KITCHEN 304 2432 Yes 0 1 Yes Yes Yes 6 M BEDROOM 201 1608 No 0 1 1 Yes Yes Yes 7 M W IC 36 288 No 0 1 Yes Yes Yes 8 STAIRS UP 72 576 No 0 1 Yes Yes Yes 9 W/D 18 144 No 0 1 No Yes Yes 10 HALLWAY 64 512 No 0 1 No Yes Yes 11 M TOILET 24 192 No 0 1 Yes Yes Yes 12 M BATH 88 704 No 0 1 Yes Yes Yes 13 CLST 3 14 112 No 0 1 Yes Yes Yes 14 BEDROOM 3 120 960 No 0 1 1 Yes Yes Yes 15 BEDROOM 2 133 1064 No 0 1 1 Yes Yes Yes 16 AHU CLST 9 72 No 0 1 No Yes Yes 17 WIC 2 33 264 No 0 1 Yes Yes Yes 6/10/2021 8:35 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation LIVING/DINING R 58.2 ft 407 ft2 ____ 1 0 0 2 Slab-On-Grade Edge Insulation PANTRY 1 ft 20 ft2 ____ 1 0 0 3 Slab-On-Grade Edge Insulation BATH 6 ft 60 ft2 ____ 1 0 0 4 Slab-On-Grade Edge Insulation WIC 18 ft 70 ft2 ____ 1 0 0 5 Slab-On-Grade Edge Insulation KITCHEN 45.4 ft 304 ft2 ____ 1 0 0 6 Raised Floor M BEDROOM ____ ---- 201 ft2 1 0 0 7 Raised Floor M W IC ____ ____ 36 ft2 1 0 0 8 Raised Floor STAIRS UP ____ ____ 72 ft2 1 0 0 9 Raised Floor W/D ____ ____ 18 ft2 1 0 0 10Raised Floor HALLWAY ____ ---- 64 ft2 1 0 0 11Raised Floor M TOILET ---- -___ 24 ft2 1 0 0 12Raised Floor M BATH ____ ____ 88 ft2 1 0 0 13Raised Floor CLST 3 ____ ____ 14 ft2 1 0 0 14Raised Floor BEDROOM 3 ____ ____ 120 ft2 19 1 0 0 15Raised Floor BEDROOM 2 ____ ____ 133 ft2 19 1 0 0 16Raised Floor AHU CLST ____ ---- 9 ft2 1 0 0 17Raised Floor WIC 2 ____ ---_ 33 ft2 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1763 ft2 0 ft2 Light N 0.3 No 0.9 No 19 18.43 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1673 ft2 N N 6/10/2021 8:35 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) LIVING/DINING R 0 Blown 407 ft2 0.1 Wood 2 Under Attic(Unvented) PANTRY 0 Blown 20 ft2 0.1 Wood 3 Under Attic(Unvented) BATH 0 Blown 60 ft2 0.1 Wood 4 Under Attic(Unvented) WIC 0 Blown 70 ft2 0.1 Wood 5 Under Attic(Unvented) KITCHEN 0 Blown 304 ft2 0.1 Wood 6 Under Attic(Unvented) M BEDROOM 0 Blown 201 ft2 0.1 Wood 7 Under Attic(Unvented) M W IC 0 Blown 36 ft2 0.1 Wood 8 Under Attic(Unvented) STAIRS UP 0 Blown 72 ft2 0.1 Wood 9 Under Attic(Unvented) W/D 0 Blown 18 ft2 0.1 Wood 10 Under Attic(Unvented) HALLWAY 0 Blown 64 ft2 0.1 Wood 11 Under Attic(Unvented) M TOILET 0 Blown 24 ft2 0.1 Wood 12 Under Attic(Unvented) M BATH 0 Blown 88 ft2 0.1 Wood 13 Under Attic(Unvented) CLST 3 0 Blown 14 ft2 0.1 Wood 14 Under Attic(Unvented) BEDROOM 3 0 Blown 120 ft2 0.1 Wood 15 Under Attic(Unvented) BEDROOM 2 0 Blown 133 ft2 0.1 Wood 16 Under Attic(Unvented) AHU CLST 0 Blown 9 ft2 0.1 Wood 17 Under Attic(Unvented) WIC 2 0 Blown 33 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belowo 1 N Exterior Concrete Block-PolystylAWNG/DININ 0 21 7 8 0 172.7 ft2 0 0 0.3 0 2 NE Exterior Concrete Block-PolystylAWNG/DININ 0 3 7 8 0 28.7 ft2 0 0 0.3 0 3 E Exterior Concrete Block-PolystylAWNG/DININ 0 17 0 8 0 136.0 ft2 0 0 0.3 0 4 W Exterior Concrete Block-PolystylAWNG/DININ 0 16 0 8 0 128.0 ft2 0 0 0.3 0 5 W Exterior Concrete Block-PolystyrenEBATH 0 6 0 8 0 48.0 ft2 0 0 0.3 0 6 E Exterior Concrete Block-Polystyrene W IC 0 1 0 8 0 8.0 ft2 0 0 0.3 0 7 S Exterior Concrete Block-Polystyrene W IC 0 10 0 8 0 80.0 ft2 0 0 0.3 0 8 W Exterior Concrete Block-Polystyrene W IC 0 7 0 8 0 56.0 ft2 0 0 0.3 0 9 E Exterior Concrete Block-PolystyreK@TCHEN 0 23 0 8 0 184.0 ft2 0 0 0.3 0 10 SE Exterior Concrete Block-PolystyreMTCHEN 0 9 5 8 0 75.3 ft2 0 0 0.3 0 11 S Exterior Concrete Block-PolystyreK@TCHEN 0 5 0 8 0 40.0 ft2 0 0 0.3 0 12 W Exterior Concrete Block-PolystyreK@TCHEN 0 8 0 8 0 64.0 ft2 0 0 0.3 0 13 N Exterior Concrete Block-Polysty ArREDROOM 0 7 0 8 0 56.0 ft2 0 0 0.3 0 14 NE Exterior Concrete Block-PolystytArB2EDROOM 0 3 7 8 0 28.7 ft2 0 0 0.3 0 15 E Exterior Concrete Block-Polysty ArB2EDROOM 0 10 0 8 0 80.0 ft2 0 0 0.3 0 16 W Exterior Concrete Block-Polysty ArREDROOM 0 5 0 8 0 40.0 ft2 0 0 0.3 0 17 NW Exterior Concrete Block-Polysty ArREDROOM 0 14 5 8 0 115.3 ft2 0 0 0.3 0 18 W Exterior Concrete Block-Polystyren6A W IC 0 6 0 8 0 48.0 ft2 0 0 0.3 0 19 W Exterior Concrete Block-Polystyr&Te41RS UP 0 8 0 8 0 64.0 ft2 0 0 0.3 0 20 E Exterior Concrete Block-PolystyreAabTOILET 0 3 0 8 0 24.0 ft2 0 0 0.3 0 21 E Exterior Concrete Block-PolystyrerPd BATH 0 11 0 8 0 88.0 ft2 0 0 0.3 0 22 E Exterior Concrete Block-PolystyrenDLST 3 0 2 0 8 0 16.0 ft2 0 0 0.3 0 23 E Exterior Concrete Block-PolystyBEDROOM 3 0 9 0 8 0 72.0 ft2 0 0 0.3 0 6/10/2021 8:35 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below o 24 SE Exterior Concrete Block-Polystyf&EDROOM 3 0 11 8 8 0 93.3 ft2 0 0 0.3 0 25 S Exterior Concrete Block-Polystyf&EDROOM 2 0 11 0 8 0 88.0 ft2 0 0 0.3 0 26 W Exterior Concrete Block-Polysty&EDROOM 2 0 11 0 8 0 88.0 ft2 0 0 0.3 0 27 W Exterior Concrete Block-Polystyrend/V IC 2 0 6 0 8 0 48.0 ft2 0 0 0.3 0 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.65 0.25 Y 59.0 ft2 1 ft 0 in 1 ft 4 in None None 2 N 1 Vinyl Low-E Single Yes 0.65 0.25 Y 33.3 ft2 1 ft 0 in 1 ft 4 in None None 3 W 4 Vinyl Low-E Single Yes 0.65 0.25 Y 8.0 ft2 1 ft 0 in 1 ft 4 in None None 4 W 5 Vinyl Low-E Single Yes 0.65 0.25 Y 2.0 ft2 1 ft 0 in 1 ft 4 in None None 5 E 9 Vinyl Low-E Single Yes 0.65 0.25 Y 9.0 ft2 1 ft 0 in 1 ft 4 in None None 6 SE 10 Vinyl Low-E Single Yes 0.65 0.25 Y 12.0 ft2 1 ft 0 in 1 ft 4 in None None 7 S 11 Vinyl Low-E Single Yes 0.65 0.25 Y 20.0 ft2 10 ft 0 in 1 ft 4 in None None 8 N 13 Vinyl Low-E Single Yes 0.65 0.25 Y 33.3 ft2 1 ft 0 in 1 ft 4 in None None 9 W 16 Vinyl Low-E Single Yes 0.65 0.25 Y 4.0 ft2 1 ft 0 in 1 ft 4 in None None 10 NW 17 Vinyl Low-E Single Yes 0.65 0.25 Y 29.0 ft2 1 ft 0 in 1 ft 4 in None None 11 W 18 Vinyl Low-E Single Yes 0.65 0.25 Y 4.0 ft2 1 ft 0 in 1 ft 4 in None None 12 W 19 Vinyl Low-E Single Yes 0.65 0.25 Y 24.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 13 E 20 Vinyl Low-E Single Yes 0.65 0.25 Y 4.0 ft2 1 ft 0 in 1 ft 4 in None None 14 E 21 Vinyl Low-E Single Yes 0.65 0.25 Y 4.0 ft2 1 ft 0 in 1 ft 4 in None None 15 SE 24 Vinyl Low-E Single Yes 0.65 0.25 Y 15.0 ft2 1 ft 0 in 1 ft 4 in None None 16 S 25 Vinyl Low-E Single Yes 0.65 0.25 Y 15.0 ft2 1 ft 0 in 1 ft 4 in None None 17 W 26 Vinyl Low-E Single Yes 0.65 0.25 Y 4.0 ft2 1 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1115.3 61.19 114.88 .1191 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 29.4 kBtu/hr 882 cfm 0.8 1 sys#1 6/10/2021 8:35 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless WIC 0.99 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 140 ftz Attic 14 ft2 Default Leakage AHU CLST (Default)c(Default)c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb Mar Apr May rjJun rj Jul rj Aug �Xj Se Oct Nov Dec Heatin HJan Feb Mar Apr May Jun Jul Au Sep Oct Nov Dec Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz Oft 0.3 LIVING/DINING RM Default(8 Ibs/sq.ft. ftz ft 0.3 PANTRY Default(8 Ibs/sq.ft. ftz ft 0.3 BATH Default(8 Ibs/sq.ft. ftz ft 0.3 WIC Default(8 Ibs/sq.ft. ftz ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ftz ft 0.3 M BEDROOM Default(8 Ibs/sq.ft. ftz ft 0.3 M W IC Default(8 Ibs/sq.ft. ftz ft 0.3 STAIRS UP Default(8 Ibs/sq.ft. ftz ft 0.3 W/D Default(8 Ibs/sq.ft. ftz ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ftz ft 0.3 M TOILET Default(8 Ibs/sq.ft. ftz ft 0.3 M BATH Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ftz ft 0.3 AHU CLST 6/10/2021 8:35 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 6/10/2021 8:35 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 7 of 7 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. LOT 1106 NETTLES ISLAND, JENSEN BEACH, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Polystyrene Bead AggrER=0.0 1970.00 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 11.Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=19.0 1673.00 ft2 6. Conditioned floor area(ft2) 1673 b.N/A R= ft2 7. Windows- Description Area c.N/A R= ft2 a. U-Factor: Sgl,U=0.65 279.67 ft2 12.Ducts,location&insulation level R ft2 a.Sup:Attic,Ret:Attic,AH:AHU CLST 6 140 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 SHGC: 13.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 29.4 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14.Heating systems kBtu/hr Efficiency SHGC: a.Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 1.644 ft. Area Weighted Average SHGC: 0.250 8. Skylights Description Area 15.Hot water systems a. U-Factor(AVG): N/A ft2 a.Electric Cap: 1 gallons EF:0.99 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 861.00 ft2 Credits(Performance method) None b.Raised Floor R=0.0 559.00 ft2 c.other(see details) R= 253.00 ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building * ° Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed CAD WE based on installed Code compliant features. Builder Signature: Date: g O�DOE STA Address of New Home: City/FL Zip: ' *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/10/2021 8:38 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WITHERS RESIDENCE Builder Name: JWN BUILDERS,LLC. Street: LOT 1106 NETTLES ISLAND Permit Office: ST LUCIE COUNTY City,State,Zip: JENSEN BEACH , FL, Permit Number: Y U Owner: Jurisdiction: ST LUCIE COUNTY w Design Location: FL,Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or ceiling Concealed When required to be sealed,concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer.Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Nates and walls or ceilin s. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 6/10/2021 8:38 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1