HomeMy WebLinkAboutWithers_res_Cad plan-S-3 BRACBRACING NOTES: I. BRACING SHOWN DOE5 NOT INCLUDE TEMPORARY BRACING REQUIRED FOR THE ERECTION AND INSTALLATION OF TRU55E5 PRIOR TO THE INSTALLATION OF PERMANENT CRO35 BRACING AND WEB LATERAL BRACING REQUIREMENT-5. TEMPORARY BRACING I5 THE RESPONSIBILITY OF THE TRU55 INSTALLER AND SHOULD REMAIN IN PLACE AS LONG AS NECE55ARY FOR THE SAFE AND ACCEPTABLE INSTALLATION OF THE ROOF OR FLOOR. (REF: BC51). 2. PERMANENT WEB LATERAL BRACING IS TO BE INSTALLED AS 5HOWN ON THE INDIVIDUAL TRU55 ORAWIN65 (WEB LATERAL BRACING 15 NOT 5HOWN ON THI5 SHEET). PERMANENT WEB LATERAL BRACING IS TO BE RESTRAINED TO PREVENT LATERAL MOVEMENT BY SOLID ANCHORAGE TO END WALL5, OR BY PERMANENT DIAGONAL BRACING (NOT SHOWN) IN THE PLANE OF THE WEB MEMBER AT INTERVALS NOT TO EXCEED 20 FEET ALONG CONTINUOUS WEB BRACE. (REF: BC51). 3. PERMANENT DIAGONAL BRACING AS SHOWN ON THI5 SHEET DOES NOT INCLUDE BRACING REQUIRED FOR GABLE END 5TU05 OR BOTTOM CHORD OF GABLE END AT WALL. REFER TO 5TANDAR0 GABLE END DETAIL FOR BRACING REQUIREMENTS. 4. ALL TOP CHOR05 ARE A55UME0 TO BE 5HEATHED, AND ALL BOTTOM CHOR05 BRACED BY A RIGID CEILING 5Y.5TEM. REFER TO INDIVIDUAL TRUSS DRAWINGS FOR BRACING REQUIREMENTS OF NON -SHEATHED TOP CHORDS AND UNSUPPORTED BOTTOM CHORDS. 5. REFER TO TPI / WCTA BC51: COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION AND BRACING METAL PLATE CONNECTED WOOD TRU55E5" APPENDIX C, FOR RECOMMENDED SEQUENCE OF INSTALLING BRACING COMPONENTS. 6. THE STRUCTURAL ADEQUACY OF THE INDIVIDUAL TRU55 DESIGNS TO WITH5TAND GRAVITY AND WIND LOA0ING5 A5 WELL A5 GIRDER CONNECTIONS AND LOADS ARE THE RE5PON51BIL17Y OF THE TRU55 DE516NER. ANCHORAGE OF THE TRUSSES AND GIRDERS TO THE SUPPORTING STRUCTURE TO WITHSTAND WIND UPLIFT 15 THE RESPONSIBILITY OF THE PROJECT ENGINEER OR ARCHITECT. 7. THE BRACING FOR THE ROOF SYSTEM 15 OE51ONEO FOR BOTH POSITIVE $ NEGATIVE PRE55URE AND MEETS THE REQUI REMENT5 OF 2020 FBC. BRACING LEGEND: PERMANENT 2x4 DIAGONAL BRACE RESTRAINT IN THE PLANE OF THE NEAREST WEB MEMBER AT 20'-0" INTERVALS AT APPROXIMATELY 45 DEGREE ANGLE. FASTEN TO OFF051TE 5IDE OF WEB WITH 3-16d TOENAILS AND TO LATERAL BRACE WITH (5) IOd NAILS EACH INTERSECTION. (REF: B051). HORIZONTAL BRIDGING WITH A MINIMUM 2x6 5TRON6BACK AT 6-0" 0/0. FASTEN TO EACH TRUSS WITH 3-IOd NAILS AND ATTACH TO WALL5 OR OTHER RIGID POINT AT EACH END (REF: 1305I). PROVIDE OVERLAP OF AT LEAST (3) TRUSSES (FLOOR ONLY). PERMANENT 2x4XCONT. LATERAL BRACING IN THE PLANE OF THE STRUCTURAL BOTTOM CHORD OF THE TRUSSES AT I 6-0" 0/0. FASTEN WITH 2-I0d NAILS IN EACH TRUSS. PROVIDE OVERLAP OF AT LEAST (2) TRUSSES (ROOF ONLY). ZONES I $ 2 (5EE DIAPHRAGM SCHEDULE) ZONE 3 (5EE DIAPHRAGM SCHEDULE) BRACING DETAILS: 5HEATHI N6 COMPRESSION WEB SLOPING OR VERTICAL CONTINUOUS PERMANENT LATERAL BRACING (C.L.B) PERMANENT DIAGONAL BRACE NAILED TO OFF. 5I0E OF WEB PREVENTS LATERAL MOVEMENT AND SHOULD BE REPEATED AT APPROX. 20 FOOT INTERVALS CEILING FIGURE 36: PERMANENT DIAGONAL BRACING IN THE PLANE OF THE WEB MEMBERS .,...,... , - GRO55 FIGURE 37.- PERMANENT BRACING IN THE PLANE OF THE WEB5 FOR PITCHED TRU55E5 HORIZONTAL BRIDGING WITH A MINIMUM 2x6 5TRON6BACK CONNECTION TO EACH TRU55 WITH 3-I0d NAILS AND ATTACHED TO WALL5 OR OTHER RIGID POINT AT EACH END (REF: BC51). PROVIDE OVERLAP OF AT LEAST (5) TRU55E5 (FLOORS ONLY). SEE PLAN FIGURE 38: PERMANENT BRACING IN THE PLANE OF THE WEB5 FOR PARALLEL CHORD TRU55E5 LATERAL BRACE PERMANENT WEB DIAGONAL CRO55 BRACING GROUP OF WOOD TRU5555 (WEB MEMBERS) FIGURE 3q: PERMANENT BRACING IN THE PLANE OF THE WEB5 TRUSS GONNEGTOR SCHEDULE FA57ENER5 PER 5TRAP ALLOWABLE UPLIFT PARALLEL LOAD (F2) PERPEND. LOAD (FI) PRODUCT MARK U5P CONNECTOR TRUSS CONC./TIE-BEAM 51NOLE STRAP DOUBLE STRAP 51NOLE STRAP DOUBLE STRAP 51N6LE STRAP DOUBLE STRAP APPROVAL TC-I I HTA 12/12R (g) 10d x 1-1/2" - 070 # 2450 # 710 # 1510 # 270 # 1215 # FL 176eO TC-2 HTA 20/20 (q) 10d x 1-1/2" - 1870 # 2450 # 710 # 1510 # 270 # 1215 # FL 17680 TC-3 R716M (g) IOd x 1-1/2" (4) 1/4" x 1-3/4" TAP. 13g5 # 27gO # 4eo # g60 # 650 # 1260 # FL 1073q TC-4 HGAMIOKT (4) I/4'5(I-I/2" WS (4) 1/4" x 1-3/4" TAP. 17l5 # 1e30 # 740 # 14eO # 1 1075 # 2150 # FL 176gq I) ALLOWABLE LOADS ARE BASED ON U5P CATALOG 59TH Ed. 2) BLDR MAY USE LONGER 5TRAP5 OF SAME TYPE SPECIFIED. 3) USE GALVANIZED NAILS AS SPECIFIED BY MANUFACTURER. 4) TAPCON5 SHOULD BE LOCATED AT THE FARTHEST POINT FROM THE TOP OF THE BEAM. 5) PROVIDE APPROVED M0157URE BARRIER PLATE OR BUILDING PAPER BETWEEN MASONRY WALL AND EACH TRUSS. o: EDGE STRIP DEFINED AS THE LE55ER OF 10% OF LEAST HORIZONTAL DIMENSION OF BUILDING OR 40% OF HEIGHT H BUT NOT LE35 THAN 4% OF LEAST HORIZONTAL OIMEN51ON OF BUILDING AND AT LEAST 3 FT. ROOF ZONE PRE55URE5: ZONE I = 63.8 P5F. 3 ZONE 2r= 55.2 P5F. ZONE 2e OH= 121.4 P5F. ZONE 3 OH= 121.5 P5F. NOTE: SEE DIAPHRAGM 50HEDULE FOR ROOF ZONE NAILING REQUIREMENTS. ro I I I I I I I 75 I I I I I I I I I I I I I I I 22"x36" ATTIC ACC. Lwrn6. LT I 75 w o- I I I I I I m r I I I I I I I I I Ell I I I I I Q 323# MAX. UPLIFT (2)TG-I X DIAPHRAGM SCHEDULE DIAPHRAGM NAILING DIAPHRAGM ZONE I ZONE 2 ZONE 3 PANEL FRAMING BOUNDRIE5 EDGE INTER. EDGE INTER. EDGE INTER. LOCATION PANEL GRADE THICKNE55 SPACING REMARKS ROOF APA RATED SHEATHING PALM EXPOSURE I, OR EQUAL 24" O/C IOd IOd IOd IOd IOd IOd IOd BLOCKED AS BEACH SPAN RATING 40/20 Iq/32" MAX. 6" O/C 6" O/C 6" O/C 6" O/C 6" O/C 4" O/C 4" O/C 5HOPgN ON PLAN APA RATED SHEATHING SECOND 5TURO-I-FLOOR, OR EQ. 24" O/C IOd IOd IOd 6LUED AND BLOCKED FLOOR SPAN RATING 48/24 23/32" MAX. 6" O/C 6" O/C 10" O/C A5 5H0WN ON PLAN APA RATED SHEATHING NAIL CORNER 5TU05 EXT. EXPOSURE I, OR EQUAL 16" O/C IOd IOd IOd AT 4" O/C MAX TYPICAL WALL SPAN RATING 40120 Iq/32 MAX. 4" 0/C 4" O/C 6" O/C BLOCK FREE E0GE5 P-APAPP, G i I I II / I / I I II I II I III I II II I II II II I II III I II I I I I I II II III II III II I II I II I II L - I II tL. I 4 ^ Q O >s 001 00 O >s /� I MARK THICK GRADE NAILING PLYWOOD SHEARWALL SCHEDULE 3LOGK ALL FREE PANEL EDGE5 WITHIN 4'-0" OF GABLE ENDS AND NAIL PER ?ONE 3. (5EE DIAPHRAGM 50HEDULE) (TYP) 3LOGK ALL FREE PANEL EDGE5 WITHIN 4'-0" OF GABLE ENDS AND NAIL PER ?ONE 3. (5EE DIAPHRAGM 50HEDULE) (TYP) 5HEARWALL HOLDOWN ALLOW 57'UD5 FLOOR SILL FDN. SILL ENDPO57 2nd/ FDN. SHEAR (010 A Iq/32" APA RATED IOd NAILS ® 6" 0/C (FIELD) 2x6 #2 5P 2x6 W/ (2) ROW5 _ (2) 2x6 M5TA24 255 ONE 5I0E 40/20, EXP, 1 IOd NAILS ®4 O/C (EDGES) 0 16" O/C OF 16d NAILS 0 12 O/C #2 5P NOTES: I. ALL PANEL EDGE5 BACKED WITH 2 INCH NOMINAL OR WIDER FRAMING 2. ALL NAILS ARE COMMON, TYPICAL. 3. STRICTLY FOLLOW ALL U5P MANUFACTURER'S GUIDELINES AND INSTRUCTIONS FOR INSTALLATION OF CONNECTORS revisions no. date designed PAR d rawn PAR checked 55 date 7/1/21 scale 1/4" = 1'-0" U.N.O. job no. 21-0017 . WIT QUA QUANTUM ENGINEERING ASSOCIATES INC. • Strucdui-al Engineering & Cost Segregation 6415 LAKE WORTH ROAD SUITE 105 GREENACRES, FLORIDA 33463 W W W.QEASSOCIATES.COM W, Digitally Digitally signed N. 61 00 •'C5= �= by Shawn :0T�.T<oRStambaugh N...e Date: Thsimhasbenlv."lly signedandslsha Bagh, on the d.ehw'mga2021.08.20 Digital Signature. Printed cupiesu(thisd--ntare 1,2:00:46-04'00' nsidered signed and sealed and the signature must be verified - any copies Shawn M. Stambaugh, PE FL. LIC. 61850 - C.A. 26210 W U z W 0 Q zE O C) J C/) LL �Wy LL L U z VJ � zo W �w � J _ O C project U J z J U. W W D U Ln z O � W - l7 z Z z L9 ILL W Q W _v tP LlJ drawing ROOF BRACING PLANS sheet S-3