ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Required Sections of
the Permit Application
Form
Attachments Required
See List Below
Low Slope Application
A, B, C
1,2,3,4,5,6,7
Prescriptive BUR-RAS 150
A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
1,2,4,5,6,7
Concrete or Clay Tile
A, B, D, E
1,2,3,4,5,6.7
Metal Roofs
A, B, D
1,2,3,4,5,6,7
Wood Shingles and
Shakes
Other
A, B, D
1,2,4,5,6,7
1,2,3,4,5,6,7
As Applicable
ATTACHMENTS REQUIRED As Applicable):
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3,
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
Municipal Permit Application
5.
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
5T. LUCI E
Master Permit No.
Contractors Name:
Section A (General Information)
Process No.
Code Red Roofers, Inc License # CM 326574
Job Address 3051 Charles Way
aLow Slope
❑ Asphaltic Shingles
❑ New roof ❑ Repair
Low Slope Roof Area (SF) 1000
ROOF CATEGORY
❑ Mechanically Fastened Tile
Metal Panel/Shingles
❑ Prescriptive BUR-RAS 15C
ROOF ROOF TYPE.
❑ Maintenance
ROOF SYSTEM INFORMATION
Steep Sloped Roof Area (SF) 2900
❑ Mortar/Adhesive Set Tiles
❑Wood Shingles/Shakes
Reroofing ❑ Recovering
Total (SF) 3900
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
ST. LUCIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: Risisto
Product Approval No.: 17084.1
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': Zone 1: Zone 2: Zone 3:
Max. Design Pressure, from the specific product approval
system: W-8
Deck:
Type: Plywood
Gauge Thickness: 5/8
Slope:.25/12
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Self adhered
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Trufast #12 DP with Trufast 3" Metal Insulation Plates
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s): Risisto LB1236
Base Sheet Fastener/Bonding Material:
Self Adhered
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply: Risisto Torch Applied Cap sheet
Top Ply Fastener/Bonding Material:
Torch Applied
Surfacing: Granules
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':
8 it oc @ Lap, # Rows
3 @ 8 " oc
Zone 1:—"
oc @ Lap, # Rows
@ "oc
Zone 2:—"
oc @ Lap, # Rows
@ " oc
Zone 3:—"
oc @ Lap, # Rows
@ "oc
Number of Fasteners Per Insulation Board:
Zone 1': Zone 1: Zone 2: Zone 3:
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterf lashing, Coping, Etc.,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16.
Trufast A
Trufast
Insulatio
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof system Manufacturer: Extreme Metal Fabricators
Notice of Acceptance Number:
17022.1
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1: -31 Zone 2e:-53 Zone 2n: -53 Zone 2r:153 Zone 3e: -79 Zone 3r:-79
Deck Type: Plywood
Type Underlayment: GAF Stormguard (10626.1)
Roof Slope:
3 12
Insulation:
Fire Barrier:
Ridge Ventilation? Fastener Type & Spacing: ET,-:f--:t
�DP Trufast 3" Metal Insulation Plates
Adhesive Type:F -- SA Base Sheet
Type Cap Sheet: Torch applied I
Mean Roof Height: 10' Roof Covering: 5v Metal (17022.1)
Type & Size Drip 26 ga. galv. 3x3
Edge: