Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Revisions; AC Pad
OFFICE USE ONLY: DATE FILED: 9, PERMIT# 2380 REVISION FEE: j7 _� RECEIPT # LOCATION/SITE PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772)462.1553 APPLICATION FOR BUILDING PERMIT REVIIS,,, PROJECT INFORMATION SION Ora 0.1 Liu ETAILED DESCRIPTION OF PROJECT REVISIONS: _a2r evi��'an S CONTRACTOR INFORMATION STATE of FL REG./CERT. #: CBC051145 BUSINESS NAME: GRBK GHO Ho� me QUALIFIERS NAME: William Handler ADDRESS: 590NW Mercantile Place CITY: Pt St Lucie S,TA PHONE (DAYTIME): 772-773-0075 NAME: GRBK GHO St Lucie LLC ADDRESS:590 NW Mercantile PI: CITY: Port St Lucie PHONE (DAYTIME: 772-7734 ARCHITECT/ENGINEER I NAME: Donald J Nuelle ADDRESS: 11634 SW Rowena S CITY: Port St Lucie PIIONE (DAYTIME): 561-62E SLCCC: 9123109 Rewed 06130117 FILE COPY ST. LU IE CO CERT. #: FL ZIP: 3498E FAX: 561-688-0909 STATE: FL I MMATION: STATE: FI_ ZIP: 34E FAX: 561-688-0909 '5 qU@L E INZ Ey.d3S 3 All 3'' FOOTING SCHEDULE MARK SIZE D REINFORCING DESCRIPTION DETAIL NO. F-1 20' x 18' W/2 15 CONT. BIM. EXTERIOR MONOLITHIC ONE STORY 1 F-2 20' x 18' W/2 15 CONE. BIM. EXTERIOR MONOLITHIC ® RECESS 38 F-3 3-0' x 3'-0' x 12' W/4 15 BTM. E.W. ISOLATED PAD 7 F-4 20' x 16' W/2 15 CONE. BTM. INTERIOR MONOLITHIC 27 TE-1 10' x DROP x CONT. W/115 CONT THICKENED EDGE AT DROP 34 MASONRY WALL BEYOND PAVER RECESS CONC. BRICK PAVER SET IN SAND SLOPE PER SURVEY FOOTING SEE SCHEDULE OVERHEAD GARAGE DOOR OHD RECESS 20' DRIVEWAY / GARAGE INTERSECTION CONC, POURED FILLED — CELL W/ STL, PER PLAN DOWELL & EPDXY (1) #`. REBAR INTO SLAB 2 FILLED CELL LOCATION W/ 4' MIN, EMBED. INTO SLAB KUI NiNU 1JUND PER PLAN I CONC, SLAB & MONOLITHIC FOUNDATION PER PLAN COLUMN SCHEDULE MARK SIZE TIDE DESCRIPTION 8 x8' CONC. BLK. W/i FULLY GROUTED CELL W/1-15 VERT. EA. CELL C-1 BLOCK ® 8'-0' 0 C MAX. OR AS LOCATED ON PLANS 8'xI64 C-2 BLOCK GONG. BLOCK W 2 FULLY GROUTED CELLS W 1- 5 VERT. EA. CELL 8X12" C-3 BLOCK CONC. BLOCK W/2 FULLY GROUTED CELLS W/2-15 VERT. 12 x 12' C-4 BLOCK CONC. BLOCK W/1 FULLY GROUTED CELLS W/4-15 VERT. COOR MASONRY B' — MATCHING DOWELS FOR COLUMNS 48 BAR DIA. .. .4. ' I COLUMN MIN. W/STD. HOOKS IIVT BEARING WALL I RBERMESH �' ''h MATCHING DOWELS SEE FRAMING PUN �e"T'il' 48 BAR DUL MIN. TRANSVERSE REBAR GRADE WISTD. HOOKS ONLY AS REQD. FOOTING REBAR h 'I SEE FOOTING SCHED. N SEE FOOTING SCHED. - i .• li it I. • I FIBERMESN e WELDED WIRE MESH . . r 4' W ti a PAD REBAR SCHED, EQ, EQ. SEE FOOTING SCHEDULE EDGE BARS ALWAYS CONT REBAR FlBERMESH- SEE SCHED, REMAIN. SPACE OTHERS EQ. EQ. SEE FOOTING SCHED. 1-15 CONT. E°"'^L'Y SCHED, MIT CENTER BAR SCH ULE OHEN 3' MIN. COVER 10' O TYP. EXTERIOR CONT. MONOLITHIC FOOTING O ISOLATED PAD 38 27 O Y (2) REQD. 34 THICKENED EDGE EXT. CONT. MONOLITHIC INT. CONT. MONOLITHIC #1 -WED F0 ST, LUCIE � .Y BOC FILE COPY l PROJECT LOG ISSUED FOR PRE -CON 04-14-21 ISSUED FOR PERMIT 04-27-21 A/C PAD REVISION 08-19-21 W W e Di8 J �m Lq a W Z) Z Z.Lu � u j fNq 8 <_Fk Z a O v, o 0 rn fOc c S c N p t0 7 W d d C C C N p p tU 3 = a 9,7 d N t Lu co S c m L c N 0 o Y3 +i o m E +� a�i + to N oW �o p co Lu E au d {y+ d 6 9 =O O d _ rn N N C o C7 IE d Y du 8 Ri5 cu C7 v N ow =1 t Z d b tie O w J m Ln 2 W tY tr O • o co • 0 t CN LL_ o � O O O U ?> W °° O i--i U � J Ot W 2: Ln U.N.O. FOUNDATION PLAN A-1 MISSED COLUMN STL. DETAIL MW=18 R-40 BLOWN -IN INSULATION AT ALL A/C AREAS PROJECT LOG ISSUED FOR PRE -CON 04.14-21 ISSUED FOR PERMIT 1 04-27.21 A/C PAD REVISION 08-19-21 IMPACT / LOW E GLAZING AT WINDOWS AND SLIDING GLASS DOORS FINISHED ( OPT. 2x WD EACH S FOR MC 2x MT TYP. FINISHED F DELETE CERAMIC SOAP DISH IN ALL BATHS U VALUE SHGC TYP. WINDOW IMPACT .62 / .25 VERTICAL HEIGHT SEPARATION IS 8" ADDITIONAL NOTES: 1. STANDARD HOLLOW CORE RAISED PANEL DOORS. 2. TILE TO CEILING IN MASTER SHOWER - 8'-0" A.F.F. IN ALL OTHER SHOWERS 3. FIBERGLASS BOARD OR DUR-O-ROCK TO 8'-0" A.F.F. OR SOFFIT AROUND TUBS/SHOWERS AND TO 4'-0- A.F.F. 0 MARBLE TUBS 4. ROUNDED CORNERS AT ALL LOCATIONS EXCEPT CLOSETS, SLIDERS, WINDOWS, DOORS, VERTICAL EDGES OF CEILINGS OR AS NOTED ON PLANS. 5. KNOCKDOWN CEILING TEXTURE AND ORANGE PEEL WALL TEXTURE. 6. R-40 BLOWN -IN INSULATION AT ALL A/C AREAS 7. IMPACT ALL WINDOWS. TEMP FRAMELESS---,, GL W/ CLIPS 1/2" WALL CAP—� MTL FRAMING —� KNEEWALL W/ DRYWALL FINISH THIS SIDE TOP OF KNEEWALL W/ PT 2X TOP PLATE & 1/2" PLYWD & 1/2" NON ASBESTOS FIBER CEMENT BACKER BOARD KNEEWALL W/ NON ASBESTOS FIBER CEMENT BACKER BOARD ROMAN SHWR M PT 2X SILL PLATE L L L L L W/ 1/4"' TAP NS & FENDER WASH R TO SLAB L L L L L L LLLLLL TYP. KNEE WALL SECTION 1/2" = V-0" TYP. MEDICINE CABINET GARAGE CEILING (4) 20 METAL STUD FLOOR RO CEILING GARAGE FLOOR ELECT. PANEL / CHASE CEILING ]0'T.O.B.B. 9'-4" T.O. 16' TYPICAL FRAMING ® 16" O.C. — - FINISHED FLOOR w 3c 0 O V SOAP NICHE i< Y c • ■ ■ ■ ■ ■ ® D—---O SPUSHDELETE o 1 2X4 BEARING WALL - SEE STRUCTURAL12'-0• RANGE W MICRO ABV. 15'- DINING KITCHEN rH�.N „ -8 CLG. BBAACKIG 0 10 -8' CLG. 35"-57"-96" I E N10 SINK W/ DSP_ REFI 9'-¢I251 oDBL. w ag / 1I � o s'-z° z'-o° ■ � I I- COUNTER ®36" AFF � I � � • N ® N m °.r • SUPER KITCHEN N PACKAGE n PR 3080 POCKET ■ ® PORCH z a a I 13,-0" 7'-0" a'-6 14'-2° 8 2'-0" 9'-4" CLG.. $ : o PAVERS CO PATIO FOYER B 0 _ ----- T . 0' -8" CLG. 5-/2 3-5 1 10 -8, CLG. 3080 FULL 8 3'-4" -10° -616' 6-0N LITE EXT DR I 1 d II GREAT ROOM — , II N II PAVERS ■ -4' • ° 2'-0' 16,-0" 2'-0* I IV- G 10'-8" CLG. ■ 16070 OHD A9'-4" \ �OOM 1� n1IR c G.6 UTI LI TYA- FLAT O ARCH F� I N 2_C 'CLG. M5-8° 20 MIN. SOLID CORE 8 c 5'-0" 10 LR/A DOOR W/ RABBITTED 1 o ■ T i SH�FLF 42 AFF ® _� �rr' JAMB OVERSIZED WEATHERSTRIPPING t '-4' ■ ■ L o N 3'-?* - 0 1 ° S-6" M5SH," OPT. ILL I AND SELF -CLOSING I TWO BAY GARAGE ■ ■ rn 2880I 680 o HINGESCE I 1 N O ■ OD "0 N r I I N 9'-4" CLG. R& s • _ a I 1`�I I _— 7 8 I -----J �° ■ 13'-8° " 1'-4° _ ® R_& S _ 108 X 52" MIR OR $ oI LINE OF OVERHEAD DOOR N ■ 8'-6• SPACE , 60BO BP N 6080 BP L — J x °p W-2" 9'-0" UN. • 5-10" -0° R-11 BATT. INSULATION 0 ■ x I —I MASTER m 5 SH.� GARAGE DEMISING WALL SMOOTH COAT "v MASTER SUITE m " og BATH STUCC SH EXCEPT AOTDRIYWALL n N O 9'-4" CLG. o y-� 9'-4" CLG. I N 4'4. I BEDROOM 2 PROVIDE A 2° STL BOLLARD W/ 6 x 6 x 3/8° ■ O ® SILL ®48° t� 9'-4" CLG. BASE PLATE ATTACHED TO SLAB W/ (3) 3/8°0 m o CWiIN NGE q X 54 FRAM CLG. HGT. 7 SOAP WA.B W/ WASHERS 4' LG. FIELD VERIFY S I WIG' F.G. C P ~ I NICHE LOCATION TO PROTECT WH PER F.B.0 i 15'-0" 8'-6° 3'-0" 0° '� 4" 4• 13'-10" 26'-8" ^ WH R do S SOFFIT ®8'-6" m ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ (2) /10 S.M.S. TOP & BOTTOM 0 EACH STUD FINISHED CEILING - SEE M. WALL SECTION CONT. 25 GAUGE METAL TRACKS TOP & BOTTOM W/ (1) #10 SMS 0 24" O/C 25 GAUGE CHANNEL SHAPED STUDS 24" O/C W/1 FULL LENGTH LAYER OF 1/2" TYPE GYPSUM WALLBOARD APPLIED VERTICALLY & ATTACHED W/ 1" LONG BUGLE HEAD SCREWS TO EACH SIDE 0 12" O/C CONC. FLOOR SLAB HIL71 PINS .1450 DA x I* I.G. 0 16" 0/C W/ 1" WASHERS INTERIOR PARTITION 3/4" = V-0" 6020 FG (TEMP) SILL 0 6'-0" (2) j10 S.M.S. TOP & BOTTOM 0 EACH STUD FINISHED CEILING - SEE TYP WALL SECTION 2x6 BLOCKING 0 CABINET LOCATIONS. FASTEN EA END TO STUDS W/ (2) J10 S.M.S. EA. END 25 GAUGE CHANNEL SHAPED STUDS- 2O16- OLENGTH 4- OIC))W/1 FULLLAYER OF 1/2" TYPE GYPSUM WALLBOARD APPLIED VERTICALLY & ATTACHED W/ 1" LONG BUGLE HEAD SCREWS TO EACH SIDE 0 12" 0/C CONT. 25 GAUGE METAL TRACKS TOP & BOTTOM CONC. FLOOR SLAB HIL77 PINS .1450 DW x 10 LG. 0 16° 0/C W/ I° WASHERS TYPICAL INTERIOR PARTITION ALONG CABINETRY BACKING SCALE 3/4" = 110" WASHER K SH 35 (EG ES! i i AER 28-1/27 SPACE DRYER VENT LOCATION FRONT VIEW DRYER VENT AC CONC. PAD DETAIL N.T.S. RE Y RED CALCULATIONS TOTAL U/A 1832 S. F. COVERED ENTRY 117 S.F. Lu a LI.I � r Lq LLJ w Z Z y n w z J 0 Q• ❑ Z ° O € 0 y U o rn S c ro N v U) = T w c c o a 'Sp rn°� o a a' Ei S O °j — " aci L f0 S p to cn � OO O a-+ d' '4'' C (n o�Eo0�°Lu -8 '- J9 c to = o u " 0 > c� F-0 cn c' c c co cD vi W (���p ' Y H- Qc --• U � N Z t upa u_ W a � a 0 O U �w you I,! Q J OLLJ i Ln 1/4" = V-0" U.N.O. FLOOR PLAN COVERED PATIO 239 F. A�2 GARAGE 83 S. F. TOTAL AREA , � 2771 . MW=18 PROJECT LOG ISSUED FOR PRE -CON 04-14-21 ISSUED FOR PERMIT 04-27-21 AIC PAD REVISION 08-19-21 --- (1) SETS OF (3) /4/0 AWG. THWN IN 20 CONDUIT 200 AMP SERVICE ❑ METER DISCO PANEL 200 A 5/8" COX 10' CU SUPPLEMENTAL GROUND ROD AND TO ONE REINFORCEING BAR IN — THE FOUNDATION 20'-0' LONG MIN. ELECTRICAL RISER DIAGRAM *NOTE* - ALL ABOVE COUNTER AND ISLAND OUTLETS TO BE DECORA - ALL SWITCHES TO BE DECORA NOTE: THERMOSTAT TO BE 62" A.F.F. AND 9' HORIZONTALLY FROM ANY CORNER OF WALL OR OPENING PER PLAN nvc. nu yr eniwn Fv l TO BE NO LESS THAN 4" FROM NOTE: GARAGE PUSH BUTTON OPENINGS � LOCATED 0600 ABV GARAGE FLOOR 72" MAX. NOTE: ALL VANITY WALL LIGHTS TO BE 100" A.F.F. U.N.O. POWDER ROOM TO BE 86" A.F.F. IF APPLICABLE Plans are Prepared for the Builder and not any Planned or Future user / Home owner of the Subject Property and any Modifications, Deletions and other Changes Authorized by CHO Homes Corporation or other CHO entity are Permissible to included, but not be limited to Electrical Design Modification, Fixture or Outlet or Circuit changed, Combinations or Changes. All Final Work shall be at a minimum Equal to Code minimums and any changes are only Permissible if Suggested and complete by a licensed Electrician so long as Applicable Codes are Met and Load Sufficient to Meet GHO's minimum Level of Service and Operation. CALCULATION NOTES: A HEAT STRIP LOAD GOVERNS OVER CONDENSER UNIT LOAD. B. GENERAL LIGHTING CALCULATED ® 1,832 (SQ.FT.) x 3 (WATTS/SQ.FT.) = 5.496 / 10 (GEN.LTG.CIR.) = 550 (WATTS/EA.) C. A/C CONTRACTOR SHALL SIZE A/C UNITS. A/C UNITS SHOWN ARE FOR ELEC. CALC'S. ONLY. ELEC. PANEL "UNIT A" 200 AMP CIRC, DESCRIPTION POLE BRKR WIRE VAS 100% 1 AHU HEAT STRIP 2 60 6 0 9.6 1 A/C COMPRESSOR 2 40 8 0 0 1 RANGE 2 50 6 12.0 0 1 DRYER 2 30 10 5.0 0 1 WATER HEATER 2 25 10 4.5 0 1 WASHER 1 20 12 1.5 0 1 MICROWAVE 1 20 12 1.5 0 1 DISHWASHER 1 20 12 1.2 0 1 REFRIGERATOR 1 20 12 1.2 0 3 SMALL APPLIANCE 1 20 12 4.5 0 1 BATH GFI 1 20 12 1.5 0 12 GEN. LIGHTING 1 1 15 14 1 5.5 1 0 38.4 1 9,6 1st 10,000 at 100% = 10.00 REMAINDER AT 407 = 12,52 A/C LOAD AT 65X = 6.24 TOTAL = 28,76 x 1000/240 = 119.8 AMPS ELECTRICAL SYMBOLS Q� DUPLEX RECEPTACLE SWITCH TELEVISION JACK E DOCTOR ® RECESSED I AT 12° A.F.F. SINGLE POLE 4 PRE WIRED SECURITY USB O Q� DUPLEX RECEPTACLE SK17CH 220 V.RECEPTACLE FLOODLIGHTSS ® F.P.&SL. METER IIH AT BASE T3 THREE WAY AT 12' AF.F. Sn SMOKE g & DISC. DETECTOR DUPLEX RECEPTACLE �< FSWITCH WAC OUR WAY ER THERMOSTAT ISSMOKE / CARBON ® PANEL la AT 8" ABV. COUNTER Q INTERCOM MONOXIDE DETECTOR EXHAUST DUPLEX RECEPTACLE (y� SWITCH I AT 600 A.F.F. SWITCH FAN FLUSH IN FLOOR IR RHEOSTAT [:p DISCONNECT TELEPHONE OUTLET FL EXHAUST FAN ?DUPLEX RECEPTACLE s SWITCH ® AT 12' A.F.F. PADDLE FAN W/ LIGHT GFI ROUND FAULT r W/ OR WO/ LIGHT n DMIMER T FL FLUSH IN FLOOR FLUORESCENT RELEASE LLj DUPLEX RECEPTACLE SWITCH FIXTURE CLG. MINTED. m SPEAKER V VOLUME � m TOP REC. SWITCHED x KEYED ® IN CLG. INCANDESCENT LIGHT CONTROL W e Q�WP WATERPROOF KEYPAD INCANDESCENT LIGHT DUPLEX RECEPTACLE SECURITY FIXTURE CEILING MNTED. J I SPEAKER QUADRUPLEX III WALL OUTLET RECEPTACLE umi w ~" ; FIXTURE WALL. MINTED. a- LU LL DUPLEX RECEPTACLE JUNC71ON SPEAKER LOW VOLTAGE L u; NC UNDER COUNTER BOX s HI HAT TR Z o 4 HOME RUN ® TRANSFORMER w CLG. MOUNTED M 3 Q INTERCOM © DOOR CAT6 ® HI HAT Fla FAN BOX z N STATION I CHIME HOME RUN VAPOR PROOF IN CLG. a Z Q Z = 0 O`o 0 I CELL IR IN �i Mr. V�P � � O Cn Cn L C w O f0 c ` o T 0 a = a c n a o a n Y3 cid_++ +� � rco rcc $�+ a E Hcn W d pO N a p t F- = ao c 0 07 Q N can O C='.0 LU O 6 a� - C7 z 0� CI 0 O O 00 O 0 W J 37 =1 ELECTRICAL PLAN E-1 t z 0 G rY 2 W m N QZ N LU w i 1� 0 0 t L 0) O CD e-• r h^a LO N N h J LrL r z O U LU U J Ln MW=18