Loading...
HomeMy WebLinkAboutwater heaterPRINTED IN U.S.A. 12/20 WP FORM NO. PROG RHPV Rev. 6 INTEGRAT ED HOME COMFORTINTEGRATED HOME COMFORT Professional Classic® Power Vent gas water heaters offer up to 150 foot vent runs, energy efficiency and the Guardian System Professional Classic Power Vent 40 and 50-Gallon Capacities Up to 42,000 BTU/h Natural and LP Gas Efficiency • .65 - .70 UEF • ENERGY STAR® rated Performance • FHR: 66 - 86 gallons • Recovery: 32.4 to 42.4 GPH at a 90° F rise Self-Diagnostic System • Electronic gas control for improved monitoring and service Low Emissions • Eco-friendly burner, low NOx design Features • Uses indoor air for combustion; blower exhausts the flue gases • Standard 120 VAC electrical connection • New whisper quiet blower Guardian System™ & Sensor • Exclusive air/fuel shut-off device • Maintenance free – no filter to clean • Protective control system that disables the heater in the presence of flammable vapor accumulation Flexible Venting Options • Long venting lengths up to 150 equivalent feet • PVC, ABS, or CPVC vent pipe options • Vertical or horizontal termination Longer Life • Premium grade anode rod provides long-lasting tank protection High Altitude Compliant • All models certified for applications up to 7,800 ft. above sea level Plus… • Enhanced flow brass drain valve • Temperature and pressure relief valve included • Low lead compliant • Durable Silicon Nitride Ignitor (HSI) • EverKleen® patented system fights sediment build-up • Standard replacement parts Warranty • 6-Year limited tank and parts warranty* • With ProtectionPlus® the 6-year limited tank warranty becomes 10-year * See Residential Warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. Maintenance Free Flame Arrestor PlateCombustion Shut-off System LEED Point = 1 Water INTEGRATED HOME COMFORT Residential Gas Professional Classic Power Vent Water Heaters See specifications chart on back. PRINTED IN U.S.A. 12/20 WP FORM NO. PROG RHPV Rev. 6 INTEGRAT ED HOME COMFORTINTEGRATED HOME COMFORT In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.rheem.com Water INTEGRATED HOME COMFORT Residential Gas Professional Classic Power Vent Water Heaters Professional Classic® Power Vent Specifications HOTWATERCONNECTION COLDWATERCONNECTION POWER VENTASSEMBLY C B FA D G G E T&P FITTING3/4" N.P.T. 1/2" ANODE ROD 2 Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements. DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES)ENERGY INFO. T Y P E NOMINAL GALLON CAPACITY RATED GALLON CAPACITY MODEL NUMBER GAS INPUT IN THOUS. BTU/H RECOVERY IN G.P.H. 90° F RISE FIRST HOUR RATING (GALLONS) HEIGHT TO TOP OF ASSEMBLY A TANK HEIGHT B DIAM. C HT. TO GAS CONN. D WATER CONN. CENTER E HT. TO SIDE T&P VALVE F WATER CONN. SIZE G SHIP WT. (LBS) UNIFORM ENERGY FACTOR (UEF)NAT.LP NAT.LP NAT.LP Tall 40 38 PROG40-40N RH67 PV 40 –40.4 –86 –66-1/4 59 19-3/4 14 8 53-1/2 3/4 137 0.69 Tall 40 38 PROG40-36P RH67 PV –36 –36.4 –86 66-1/4 59 19-3/4 14 8 53-1/2 3/4 137 0.69 Tall 50 48 PROG50-42N RH67 PV 42 –42.4 –78 –65-1/2 58 21-3/4 14 8 52-1/2 3/4 170 0.68 Tall 50 48 PROG50-42P RH67 PV –42 –42.4 –78 65-1/2 58 21-3/4 14 8 52-1/2 3/4 170 0.68 Short 40 39 PROG40S-36N RH67 PV 36 –36.4 –66 –58-1/4 51-1/4 21-3/4 14 8 44-1/4 3/4 161 0.65 Short 40 39 PROG40S-32P RH67 PV –32 –32.4 –66 58-1/4 51-1/4 21-3/4 14 8 44-1/4 3/4 161 0.65 Short 50 48 PROG50S-36N RH67 PV 36 –36.4 –78 –58-1/4 51-1/4 23-3/4 14 8 44 3/4 185 0.70 Short 50 48 PROG50S-32P RH67 PV –32 –32.4 –78 58-1/4 51-1/4 23-3/4 14 8 44 3/4 185 0.70 Maximum and Minimum Vent Lengths for 2 - 3" Vents up to 2,000 Ft. (609 m) Above Sea Level Model Gas Heater input Vent System Diameter Min. Allowed Equivalent Vent Length Max Allowed Equivalent Vent Length Vent System TerminationBtu/hr.Inches Feet Meters Feet Meters All Natural & Propane 42,000, 40,000, 36,000, 32,000 2 7 2.1 55 16.7 45° Elbow 3 7 2.1 150 45.7 45° Elbow Maximum and Minimum Vent Lengths for 2 - 3" Vents From 2,000 Ft. (609 m) through 7,800 Ft. (2,377 m) Above Sea Level Model Gas Heater Input Vent System Diameter Min. Allowed Equivalent Vent Length Max Allowed Equivalent Vent Length Vent System TerminationBtu/hr.Inches Feet Meters Feet Meters 40 Gallon Natural 40,000 2 7 2.1 25 7.6 45° Elbow 3 7 2.1 150 45.7 45° Elbow 40 Gallon Propane 36,000 2 7 2.1 35 10.6 45° Elbow 3 7 2.1 150 45.7 45° Elbow 40 Gallon Natural & Propane 36,000, 32,000 2 7 2.1 40 12.2 45° Elbow 3 7 2.1 150 45.7 45° Elbow 50 Gallon Natural & Propane 42,000, 36,000, 32,000 2 7 2.1 35 10.6 45° Elbow 3 7 2.1 150 45.7 45° Elbow For the 2" and 3" vent, one 90° elbow is approximately equal to 5 feet of pipe. One 45° elbow is approximately equal to 2.5 feet of pipe.