HomeMy WebLinkAboutwater heaterPRINTED IN U.S.A. 12/20 WP FORM NO. PROG RHPV Rev. 6
INTEGRAT ED HOME COMFORTINTEGRATED HOME COMFORT
Professional Classic® Power Vent gas water heaters
offer up to 150 foot vent runs, energy efficiency
and the Guardian System
Professional Classic
Power Vent
40 and 50-Gallon Capacities
Up to 42,000 BTU/h
Natural and LP Gas
Efficiency
• .65 - .70 UEF
• ENERGY STAR® rated
Performance
• FHR: 66 - 86 gallons
• Recovery: 32.4 to 42.4 GPH at a
90° F rise
Self-Diagnostic System
• Electronic gas control for
improved monitoring and
service
Low Emissions
• Eco-friendly burner, low NOx design
Features
• Uses indoor air for combustion;
blower exhausts the flue gases
• Standard 120 VAC electrical
connection
• New whisper quiet blower
Guardian System™ & Sensor
• Exclusive air/fuel shut-off device
• Maintenance free – no filter to clean
• Protective control system that
disables the heater in the presence of
flammable vapor accumulation
Flexible Venting Options
• Long venting lengths up to 150
equivalent feet
• PVC, ABS, or CPVC vent pipe options
• Vertical or horizontal termination
Longer Life
• Premium grade anode rod provides
long-lasting tank protection
High Altitude Compliant
• All models certified for applications up
to 7,800 ft. above sea level
Plus…
• Enhanced flow brass drain valve
• Temperature and pressure relief valve
included
• Low lead compliant
• Durable Silicon Nitride Ignitor (HSI)
• EverKleen® patented system fights
sediment build-up
• Standard replacement parts
Warranty
• 6-Year limited tank and parts
warranty*
• With ProtectionPlus® the 6-year limited
tank warranty becomes 10-year
* See Residential Warranty Certificate for
complete information
Units meet or exceed ANSI requirements and have
been tested according to D.O.E. procedures. Units
meet or exceed the energy efficiency requirements
of NAECA, ASHRAE standard 90, ICC Code and all
state energy efficiency performance criteria.
Maintenance Free
Flame Arrestor PlateCombustion Shut-off System
LEED Point = 1
Water INTEGRATED HOME COMFORT
Residential Gas
Professional Classic
Power Vent Water Heaters
See specifications chart on back.
PRINTED IN U.S.A. 12/20 WP FORM NO. PROG RHPV Rev. 6
INTEGRAT ED HOME COMFORTINTEGRATED HOME COMFORT
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100
Roswell, Georgia 30076 • www.rheem.com
Water INTEGRATED HOME COMFORT
Residential Gas
Professional Classic
Power Vent Water Heaters
Professional Classic® Power Vent Specifications
HOTWATERCONNECTION COLDWATERCONNECTION
POWER VENTASSEMBLY
C
B FA
D
G G
E
T&P FITTING3/4" N.P.T.
1/2"
ANODE ROD
2
Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements.
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES)ENERGY INFO.
T
Y
P
E
NOMINAL
GALLON
CAPACITY
RATED
GALLON
CAPACITY
MODEL
NUMBER
GAS INPUT
IN THOUS.
BTU/H
RECOVERY
IN G.P.H.
90° F RISE
FIRST HOUR
RATING
(GALLONS)
HEIGHT
TO
TOP OF
ASSEMBLY
A
TANK
HEIGHT
B
DIAM.
C
HT. TO
GAS
CONN.
D
WATER
CONN.
CENTER
E
HT. TO
SIDE T&P
VALVE
F
WATER
CONN.
SIZE
G
SHIP
WT.
(LBS)
UNIFORM
ENERGY
FACTOR
(UEF)NAT.LP NAT.LP NAT.LP
Tall 40 38 PROG40-40N RH67 PV 40 –40.4 –86 –66-1/4 59 19-3/4 14 8 53-1/2 3/4 137 0.69
Tall 40 38 PROG40-36P RH67 PV –36 –36.4 –86 66-1/4 59 19-3/4 14 8 53-1/2 3/4 137 0.69
Tall 50 48 PROG50-42N RH67 PV 42 –42.4 –78 –65-1/2 58 21-3/4 14 8 52-1/2 3/4 170 0.68
Tall 50 48 PROG50-42P RH67 PV –42 –42.4 –78 65-1/2 58 21-3/4 14 8 52-1/2 3/4 170 0.68
Short 40 39 PROG40S-36N RH67 PV 36 –36.4 –66 –58-1/4 51-1/4 21-3/4 14 8 44-1/4 3/4 161 0.65
Short 40 39 PROG40S-32P RH67 PV –32 –32.4 –66 58-1/4 51-1/4 21-3/4 14 8 44-1/4 3/4 161 0.65
Short 50 48 PROG50S-36N RH67 PV 36 –36.4 –78 –58-1/4 51-1/4 23-3/4 14 8 44 3/4 185 0.70
Short 50 48 PROG50S-32P RH67 PV –32 –32.4 –78 58-1/4 51-1/4 23-3/4 14 8 44 3/4 185 0.70
Maximum and Minimum Vent Lengths for 2 - 3" Vents
up to 2,000 Ft. (609 m) Above Sea Level
Model Gas
Heater input Vent System
Diameter
Min. Allowed Equivalent
Vent Length
Max Allowed Equivalent
Vent Length Vent System
TerminationBtu/hr.Inches Feet Meters Feet Meters
All Natural &
Propane
42,000,
40,000,
36,000,
32,000
2 7 2.1 55 16.7 45° Elbow
3 7 2.1 150 45.7 45° Elbow
Maximum and Minimum Vent Lengths for 2 - 3" Vents
From 2,000 Ft. (609 m) through 7,800 Ft. (2,377 m) Above Sea Level
Model Gas
Heater Input Vent System
Diameter
Min. Allowed Equivalent
Vent Length
Max Allowed Equivalent
Vent Length Vent System
TerminationBtu/hr.Inches Feet Meters Feet Meters
40 Gallon Natural 40,000
2 7 2.1 25 7.6 45° Elbow
3 7 2.1 150 45.7 45° Elbow
40 Gallon Propane 36,000
2 7 2.1 35 10.6 45° Elbow
3 7 2.1 150 45.7 45° Elbow
40 Gallon Natural &
Propane
36,000,
32,000
2 7 2.1 40 12.2 45° Elbow
3 7 2.1 150 45.7 45° Elbow
50 Gallon Natural &
Propane
42,000,
36,000,
32,000
2 7 2.1 35 10.6 45° Elbow
3 7 2.1 150 45.7 45° Elbow
For the 2" and 3" vent, one 90° elbow is
approximately equal to 5 feet of pipe.
One 45° elbow is approximately equal to
2.5 feet of pipe.