HomeMy WebLinkAboutPRODUCT APPROVAL SLIDING DOORA·L·I
(Validator / Operations Administrator)
Simonton Windows
1 Cochrane Dr.
Pennsboro, WV 26415
Attn: Tina Seese
AAMA
CERTIFICATION PROGRAM
AUTHORIZATION FOR PRODUCT CERTIFICATION
MiA
MA
This authorization is based on the successful completion of tests, and the reporting to the AAMA Validator of the results of the tests by an
AAMA Accredited Laboratory. The product information below will be added to the next update of the AAMA Certified Products Directory.
SPECIFICATIONS
AAMA/WDMA/CSA 101/1.S.2/A440-08
R-PG50-2419x2419 (95x95)-SD
COMPANY AND CODE
Simonton Windows
Code: SIM
PA 201, 202, 203
Missile Level: Large
Rating: +50/-50, 95x95
Rating above conforms
to the requirements of:
TAS 201, TAS 202,
and TAS 203
CPD
NO.
13183
RECORD OF PRODUCT TESTED
SERIES MODEL &
PRODUCT DESCRIPTION
11-11 STORMBREAKER
PLUS SGD
(PVC)(OX)(OG)
(INS TEMP/SGP LAM GL)
(MODIF)(REINF)(ASTM)
MAXIMUM SIZE TESTED
FRAME (mm)
2419 x 2419
(7'11" x 7'11")
This Certification will expire December 18, 2021 (extended from December 18, 2016 per AAMA 103-15) and requires validation
until then by continued listing in the current AAMA Certified Products Directory.
Structural Test & Report By:
Architectural Testing, Inc.
Report No: C6575.01-109-47
Date of Report: April 3, 2013
JGSIJTS
ACP-14 (Rev. 6/16)
Missile Impact Test & Report By:
Architectural Testing, Inc.
Report No: C4061.01-501-18
Date of Report: January 21, 2013
Evaluated for Certification: July 21, 2016
Asdociated Laboratories, Inc.
Authorized for Certification: July 21, 2016
AmeridWI Architectural Manufacturers Association
PANEL (mm)
1222 x 2350
(4'0" x 7'9")
FL PE #58201
Evaluation Report DA0010-R3
December 14, 2017
Product Description: Stormbreaker Plus 300VL Impact Resistant PVC Two-Panel Sliding Patio Door,
XO or OX
Manufacturer: Simonton Windows, 1 Cochrane Ave., Pennsboro, WV
Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC
Product Approval Rule 61G20-3.005 (4). This product complies with the requirements of the Florida
Building Code including the High Velocity Hurricane Zone. The product testing standards performed are
outlined below.
Technical Documentation:
1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL
2) Installation drawing DA0010-R3, signed and sealed by Lucas A. Turner, P.E.
3) Architectural Testing Inc. (ATI) Springdale, PA test report C4061.01-501-18, signed and sealed
by Michael Stremmel, P.E. with testing performed: TAS 201/202/203 1994, and ATI York, PA
test report C6575.01-109-47-r0, with testing performed: AAMA/WDMA/CSA 101/I.S.2/A440-
05/08
4) Supplemental Calculations to support DA0010-R3, signed and sealed by Lucas A. Turner, P.E.
Installation: Units must be installed according to installation drawing DA0010-R3.
Limitations of Use: This product:
May be used up to 95.25” wide x 95.25” high OX or XO configuration with design pressures of
+/-50 psf, with max. daylight openings as shown in DA0010-R3
Requires 1” overall I.G. consisting of 3/16” tempered outboard, and inboard laminated glass
made up of 3/16” annealed – 0.090” Kuraray SentryGlas Interlayer – 3/16” annealed
Is Large Missile Impact Resistant and does not require the use of shutters
May be used in the High Velocity Hurricane Zone
Requires Deceuninck PVC extrusions per Miami-Dade N.O.A. #13-1203.02†
Requires Kuraray SentryGlas Interlayer per Miami-Dade N.O.A. #14-0916.11†
† I have evaluated the interlayer and framing materials in these NOAs and find that they comply with
the requirements of the 6th Ed. (2017) Florida Building Code for use in this product.
Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial
interest in Simonton Windows or in any company manufacturing or distributing products for which this
report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in
any other entity involved in the testing or approval process of this product.
URNER
ENGINEERING &
CONSULTING, INC.
T 1239 Jabara Ave.
North Port, FL 34288
Ph. 941-380-1574
FBPE C.O.A. #29779
12/14/2017
Lucas A. Turner, P.E.