FL#
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL8784-R13
Revision
2020
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Vi Win Tech
2400 Irvin Cobb Drive
Paducah, KY 42003
(270)538-4431
swheeler@viwintech.com
Steven Wheeler
swheeler@viwintech.com
Steve Wheeler
2400 Irvin Cobb Dr
Paducah, KY 42003
(270)538-4431
swheeler@viwintech.com
Ronnie WIiiiams
2400 Irvin Cobb Dr
Paducah, KY 42003
(270)538-4437
rwilliams@viwintech.com
Windows
Fixed
Certification Mark or Listing
National Accreditation & Management Institute
Scott Wolters, PE
Validation Checklist -Hardcopy Received
Standard
AAMA/WDMA/CSA101/I.S.2/A440
TAS 201
TAS 202
TAS 203
Florida Licensed Professional Engineer or Architect
FL8784 R13 Eguiv FL8784 Eguivalency.,_gdf
Year
2008
1994
1994
1994
https://www.floridabuilding.org/pr/pr _ app _ dtl .aspx?param=wGEVXQwtDqtpMmisUSrjw6JxuGMYyis%2bShuh81 E8NI M84LXJkDA8eQ%3d%3d 1/2
5/19/2021 Florida Building Code Online
Product Approval Method Method 1 Option A
Date Submitted
Date Validated
12/30/2020
01/04/2021
Date Pending FBC Approval
Date Approved 01/12/2021
s fP d ro ucts ummaryo
FL# Model, Number or Name Description
8784.1 SL 3100 i PW 7872 Shoreline Picture Window 3100 Profile, Impact, 78x72 . FW-
C60. SGP Innerlayer. Jamb, Fin, Flange Install.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: Yes FL8784 R13 C CAC NI008088.01-R9 ,P-df
Approved for use outside HVHZ: Yes FL8784 R13 C CAC NI008088.02-R9,P-df
Impact Resistant: Yes Quality Assurance Contract Expiration Date
Design Pressure: +60/-60 05/31/2023
Other: When used in HVHZ color of frames to be WHITE only Installation Instructions
rigid PVC. FRAME MATERIAL TO BE RIGID PVC FROM VISION FL8784 R13 II 08-00204E.P-Qf
EXTRUSIONS LTD. AAMA CERTIFIED (VEX-1). "NOT TO BE Verified By: Luis R. Lomas, P.E. FL 62514
INSTALLED 30' OR HIGHER ABOVE GROUND LEVEL" -GLASS Created by Independent Third Party : Yes
INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE Evaluation Reports
FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE NOA FL8784 R13 AE 511139-lE.P-Qf
FOR KURARAY (FORMERLY DUPONT) INTERLAYERS -"Safety Created by Independent Third Party : Yes
Glass on outside pane required in HVHZ zones"
I
8784.2 SL 3100 PW 7272 SHORELINE 3100 PICTURE WINDOW 72X72
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL8784 R13 C CAC NI009173.01-R6,P-df
Approved for use outside HVHZ: Yes FL8784 R13 C CAC NI009173-R7,P-df
Impact Resistant: No Quality Assurance Contract Expiration Date
Design Pressure: N/A 06/30/2023
Other: REFER TO APPROVAL DOCUMENT FOR DESIGN Installation Instructions
PRESSURE RATINGS . FRAME MATERIAL TO BE RIGID PVC FROM FL8784 R13 II 08-00320C,i;!df
VISION EXTRUSIONS LTD . AAMA CERTIFIED (VEX-1). Verified By: Luis Roberto Lomas 62514
Created by Independent Third Party : Yes
Evaluation Reports
FL8784 R13 AE 510422D,P-df
Created by Independent Third Party : Yes
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone : 850-487-1824
The State of Florida is an AA/EEO employer. !:&P-ll!:ight 2007-2013 State of Florida . : : Privacy Statement : : Accessibility Statement : : Refund Statement
Under Florida law, email addresses are public records . If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail . If you have any questions, please contact 850.487 .1395. *Pursuant to Section 455 .275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official commun ication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
~IC)lilJ l§j E
Credi t Ca rd
Safe
sen1rit v l\11:nucs
https://www.floridabuilding .org/pr/pr _ app _ dtl .aspx?param=wGEVXQwtDqtpMmisUSrjw6JxuGMYyis%2bShuh81 E8NI M84LXJkDA8eQ%3d%3d 2/2
CERTIFICATION NO: NI008088.01-R9
DATE: 06/03/2007
CERTIFICATION PROGRAM: Structural
COMPANY: WiWinTech
CODE: 583-1
REVISION DATE: 04/03/2019
To verify that the “Notice of Product Certification” is valid, please visit www.NAMICertification.com to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
ViWinTech Windows and Doors Series “SL 3100 i PW 7872" Impact
2400 Irvin Cobb Drive Rated Vinyl Fixed Prime Window
Paducah, KY 42003-0588 Configuration: O
(Fin Mount)
Glazing: IG-3/16" Annealed Glass/Laminate-3/16"
Annealed Glass/0.090" DuPont Sentryglas®
Plus/3/16" Annealed Glass
Frame: W-1980mm(78") H-1830mm(72")
DLO: W-1835mm(72.25") H-1690mm(66.5")
SPECIFICATION PRODUCT RATING
AAMA/WDMA/CSA 101/I.S.2/A440-05
TAS 201/202/203-94
FW-R60 1980 x 1830 (78 x 72)
Design Pressure: +60/-60 psf
Large Missile Impact Rated
Product Tested By: National Certified Testing Laboratories, Inc.
Report No: NCTL-110-10728-27/110-10728-25
Expiration Date:May 31, 2023
Administrator’s Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
NOTICE OF PRODUCT CERTIFICATION
CERTIFICATION NO: NI008088.02-R9
DATE: 06/03/2007
CERTIFICATION PROGRAM: Structural
COMPANY: WiWinTech
CODE: 583-1
REVISION DATE: 04/03/2019
To verify that the “Notice of Product Certification” is valid, please visit www.NAMICertification.com to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
ViWinTech Windows and Doors Series “SL 3100 i PW 7872" Impact
2400 Irvin Cobb Drive Rated Vinyl Fixed Prime Window
Paducah, KY 42003-0588 Configuration: O
(Flush Mount)
Glazing: IG-3/16" Annealed Glass/Laminate-3/16"
Annealed Glass/0.090" DuPont Sentryglas® Plus/3/16"
Annealed Glass
Frame: W-1980mm(78") H-1830mm(72")
DLO: W-1835mm(72.25") H-1690mm(66.5")
SPECIFICATION PRODUCT RATING
AAMA/WDMA/CSA 101/I.S.2/A440-05
TAS 201/202/203-94
FW-R60 1980 x 1830 (78 x 72)
Design Pressure: +60/-60 psf
Large Missile Impact Rated
Product Tested By: National Certified Testing Laboratories, Inc.
Report No: NCTL-110-10728-27/110-10728-26
Expiration Date:May 31, 2023
Administrator’s Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
NOTICE OF PRODUCT CERTIFICATION
L. Roberto Lomas P.E.
233 W. Main St
Danville, VA 24541
434-688-0609
rllomas@lrlomaspe.com
Manufacturer:ViWinTech Windows and Doors
2400 Irvin Cobb Dr.
Paducah, KY 42003-0588
Engineering Evaluation Report
Report No.: 511139-l E
Product Line: SL 3100 i PW 7872 Shoreline Picture Window 3100 (78x72) Impact HVHZ
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1 (a). The product listed
herein complies with requirements of the Florida Building Code.
Supporting Technical Documentation:
1. Approval document: drawing number 08-00204 Revision E, prepared, signed and sealed by L. Roberto Lomas
P.E.
2. Report No.: NCTL 110-10728-24, signed by Robert H. Zeiders, P.E.
National Certified Testing Laboratories, York, PA.
AAMA/WDMA/CSA 101/1.S.2/A440-05 (Flange installation)
Design pressure: +60.Opsf
Water penetration resistance 9.Opsf
3. Report No.: NCTL 110-10728-25, signed by Robert H. Zeiders, P.E.
National Certified Testing Laboratories, York, PA.
AAMA/WDMA/CSA 101/1.S.2/A440-05 (Fin installation)
Design pressure: +60.Opsf
Water penetration resistance 9.Opsf
4. Report No.: NCTL 110-10728-26, signed by Robert H. Zeiders, P.E.
National Certified Testing Laboratories, York, PA.
AAMA/WDMA/CSA 101/1.S.2/A440-05 (Flush installation)
Design pressure: +60.Opsf
Water penetration resistance 9.Opsf
5. Report No.: NCTL 110-10728-27, signed by Robert H. Zeiders, P.E.
National Certified Testing Laboratories, York, PA.
Flange, fin and flush installation
TAS 201-94 Large Missile Impact Test
TAS 202-94 Uniform Static Air Pressure, +60.Opsf design pressure, 9.Opsf water penetration.
TAS 203-94 Cyclic Pressure loading +60.Opsf design pressure
6. Anchor calculations, report number 511140-1, prepared, signed and sealed by L. Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure:+60.Opsf
• Maximum unit size:78" x 72"
• Units must be glazed per ASTM E1300-04, refer to approval document for glazing details.
• This product is rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in wind borne debris regions.
• Frame material to be rigid PVC.
Installation:Units must be installed in accordance with manufacturer's installation
instructions and approval document, 08-00204, Revision E.
Certification of Independence:Please note that I don't have nor will acquire a
financial interest in any company manufacturing or distributing the product(s) for which
this report is being issued. Also, I don't have nor will acquire a financial interest in any
other entity involved in the approval process of the listed product(s).
1 of 1
4\31:141.:,1./4/4.
f<2<>GEN;..ld'1-e. s
2 *" ,#1(100625 '· * 2
** S,ATE OF *.05
<328' * :L OR \01: ..'dr.S..- G44-8/OAL E"///////111\\\\\\
Luis R. Lomas, P.E.
FL No.: 62514
10/29/2015