Loading...
HomeMy WebLinkAboutLETTER-ENGINEERINGi RECEIVED PAUL WELCH INC. SEP 27 2021 Mechanical Electrical Civil Engineering St,Luoi000M Y 1984 S.W. Biltmore St. Suite#114 Perm fiq' Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 September 27, 2021 Re: Permit# 21080363 Over Hang Repair 7601 Deland Ave. Ft. Pierce, Florida To Whom It May Concern: Our office has personally inspected the 24" 2x4 scab on the existing rafter overhang w/ 12" overlap each way w/ #10 screws at 3" o.c staggered on the back side and 8" x 1/8" thick x 3 %" steel nail plate with 4" over lap at each member w/ (10) 12d nails at each member (see attached photo) at the above referenced address and find that all work meets the FBC and FRC 2020, 7t" Edition and our engineering requirements. Thank you for your attention to this matter. Sincer ly: PAUL KELCH INC. � -tea `;:��► � � e:� o. j Paul etch, P.E. Fla. R No. 29945 PW:ns REVIEWED FOR )DE COMPLIANCE r. LUCIE COUNTY BOCC REVISION I i f � t� 1 1�►11 r ��11