HomeMy WebLinkAboutLETTER-ENGINEERINGi
RECEIVED
PAUL WELCH INC. SEP 27 2021
Mechanical Electrical Civil Engineering St,Luoi000M Y
1984 S.W. Biltmore St. Suite#114 Perm fiq'
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
September 27, 2021
Re: Permit# 21080363
Over Hang Repair
7601 Deland Ave.
Ft. Pierce, Florida
To Whom It May Concern:
Our office has personally inspected the 24" 2x4 scab on the existing rafter overhang w/
12" overlap each way w/ #10 screws at 3" o.c staggered on the back side and 8" x 1/8"
thick x 3 %" steel nail plate with 4" over lap at each member w/ (10) 12d nails at each
member (see attached photo) at the above referenced address and find that all work
meets the FBC and FRC 2020, 7t" Edition and our engineering requirements.
Thank you for your attention to this matter.
Sincer ly:
PAUL KELCH INC.
� -tea `;:��► � � e:�
o.
j
Paul etch, P.E.
Fla. R No. 29945
PW:ns