Loading...
HomeMy WebLinkAboutDoole Permit #2107-0456 RevisionOFFICE USE ONLY: DATE FILED: REVISION FEE: PERAM # SLC-2107-0456 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 124 Queen Isabella Ct, Fort Pierce DETAILED DESCRIPTION OF PROJECT REVISIONS: Teeing into gas line to supply a 48,000 BTU range and an additional 8 ft of pe line to 65,000 BTU BBQ grill CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: Como Oil & Propane QUALIFIERS NAME: Dean Schnieder ADDRESS: 1701 Commerce Ave CITY: Vero Beach STATE: FL PHONE (DAYTIME): 772-492-6257 OWNER/BUILDER INFORMATION: NAME: Andrew Doole ADDRESS:124 Queen Isabella Ct CITY: Fort Pierce STATE: FL PHONE (DAYTIME: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130/17 ST. LUCIE CO CERT. #: FAX: ZIP: 32960 - - ZIP: 34949 ZIP: F.H.A REQUIREMENTS DIST. Z. P.R.M. @ P.l. Q-r P.C. SpOrp/ PLAT UMIrs NOT FOUND OR SET -FALLS IN WATER BOUNDARY SURVEY QUEEN-, ISABELLA FOUND P-K NAluvIsc COURT' @ R.P. t62'D'ASPHALT :'"�-�� CUL-DE-SAC Cl \ '•' FOUND 5/8" IRON ROD + NO ID. C2 O 0� o . 00� :ti mm SEPTIC—(- 00�— ,, y '`, A • r, O 2BA' o 120 FF LOT K BLOCK 1 2 CURVE DATA: C-1 - R-=0.Wrr=124.91, A=143°0752" C-2 - R=50.00, L=56.24, d=66°4420" C-3 - R=50.00; L=68.48, A=78°2826" C-4 - R=40.00, L=62.83, A=90°00'00" SURVEY NOTES PRaPERTPMDPPLIED BY CITY WATER. BUILDING #124 ENCOSUR LE ' FOUND 5/8" IRON ROD @ P.R.M. @ P.l. NO ID. r 0;� SET 9/2" IRON ROD LB #7893 •moo � - ,A)4 3 f9 P �. moo, ru � j�}� r%sue' w� , �KA O�•r .0 6.6' �ri~� •� POOL a :.co.9.. ao ,l, ,.::a gEAWA 9 4� LL NOT TO Fppl S N VATE CONCRETE DRIVE CROSSING LOT BOUNDARY ON NORTHERLY SIDE OF LOT. THEREARE FENCES NEAR THE BOUNDARY OF THE PROPERTY. E.O.F. =END OFFENCE t w• j a ? 0 Z 1 F 1 O B O � �P 4 T 'P y No. 6415 m w� m a STATE OF o N F1 O 4, 9 SURVEYORS CERTIFICATE I HEREBY CERTIFY THAT THIS BOUNDARY SURVEY IS A TRUE AND CORRECT REPRESENTATION OF SURVEY PREPARED UNDER MY DIRECTION. NOT VALID WITHOUT AN AUTHENTICATED ELECTRONIC SIGNATURE AND AUTHENTICATED ELECTRONIC SEAL, OR A RAISED EMBOSSED SEAL AND SIGNATURE. Kenneth Digitally signed by Kenneth Osborne ��=�•��R- Osborne Date: 2017.06.07 (SIGNED) 17:01:15-04'00' KENNETH J OSBORNE PROFESSIONAL SURVEYOR AND MAPPER A5415 (N 1) C-4 � `NOa` r'A�� C10 TARGET SURVEYIIVG, r •r .c. LB #7893 SERVING FLORIDA 6250 N. MILITARY TRAIL, SUITE 102 WEST PALM BEACH, FL 33407 PHONE (581)640-4800 STATEWIDE PHONE (800) 226.4807 STATEWIDE FACSIMILE (800)741-0578 WEBSITE: hHplltargeisurveying.nei BOARD OF COUNTY COMMISSIONERS GAS PIPING SCHEMATIC IA2] [L4] TANK L1 1-3 LS SIZE [A1] [A3] TANK SIZE: 500 GALS. APPLICANCE — TYPE/SIZE Al A 2 Range A3 BBQ Grill A4 A5 A6 PIPING LENGTH & SIZE [AS] tit-k 48,000 BTU 65,000 BTU BTU BTU BTU L1 14 FT. 314 INCH DIA. L2 8 FT. 3/4 INCH DIA. L3 FT. INCH DIA. L4 FT. INCH DIA. L5 FT. INCH DIA. L6 FT. INCH DIA. L7 FT. INCH DIA. L8 FT. INCH DIA. L9 FT. INCH DIA. L10 FT. INCH DIA. 1-11 FT. INCH DIA. L12 FT. INCH DIA. Revised 7/22/14 PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation Division [A6] (PIPE SIZE WAS TAKEN FROM THE 2014 FBC FUEL GAS CODE — TABLE 402 Web.- www.sbuciecosuov 2300 Virginia Avenue - Fort Pierce, FL. 34982-5652 Phone (772) 462-1553 FAX (772) 462-1578