APPROVED Design Pressures(1)
Property Information Owner:Xiomara Canela Address:135 NE Penlynn Ave Port Saint Lucie, FL 34983 Building Information Wind Zone:165 MPH. Exposure Category:C Minimum Building Dimension:40 ft. Mean Roof Height:10 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 49 49 7 34.4 -45.3 2 End 49 49 7 34.4 -45.3 3 End 49 49 7 34.4 -45.3 4 End 49 49 7 34.4 -45.3 5 End 49 49 7 34.4 -45.3 6 End 73 49 7 33.5 -43.5 7 End 98 49 7 32.8 -42.1 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1