HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020
RECEIVED
JUN 2 5 2021
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDIROrt 14STRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CRADY RESIDENCE
Builder Name:
Street: 9507 S INDIAN RIVER DRIVE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�4415.5 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 3903.20 ft2
b. Frame - Wood, Adjacent
R=11.0 512.33 ftz
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
11. Ceiling Types (3486.0 sqft)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 3486.00 ft2
6. Conditioned floor area above grade (ft2) 3486
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(701.0 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: HVAC CLST
R ft2
6 125
a. U-Factor: Sgl, U=0.45 701.00 ft2
b. Sup: Attic, Ret: Attic, AH: AHU 2 CLST
6 200
SHGC: SHGC=0.25
b. U-Factor. N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
18.0 SEER.16.00
c. U-Factor: N/A ft2
b. Central Unit
47.0 SEER:15.00
SHGC:
Area Weighted Average Overhang Depth: 6.624 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.250
a. Electric Strip Heat
17.0 COPA.00
b. Electric Strip Heat
34.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (3486.0 sqft.) Insulation Area
EF: 0.980
a. Raised Floor R=11.0 2223.00 ft2
b. Conservation features
b. Slab -On -Grade Edge Insulation R=0.0 1263.00 ft2
None
c. N/A R= ft2
16. Credits
None
Total Proposed Modified Loads: 125.39
Glass/Floor Area: 0.201
PASS
Total Baseline Loads: 125.57
I hereby certify that the plans and specifications covered by
Review of the plans and
0� ST,gT�.
this calculation are in compliance with the Florida Energy
specifications covered by this
.Ati 0�,
Code.
calculation indicates compliance
y` ray '' w - �.���� 0'`
with the Florida Energy Code.
PREPA E Bxy
- -
DATE. �9 Z�
Before construction is completed
this building will be inspected for
compliance with Section 553.908
0
I hereby certify that this building, as des' ned, is in compliance
Florida Statutes.
5<S
G'OD
with the Florida Energ Code.
WF.flt�
`
0WNER/AGE T � V
BUILDING OFFICIAL:
DATE: ® C -- 4 K--- Q .0 -z
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
=tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
r
4/16/2021 11:43 AM EnergyGauge® USA 7:0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 8
FORM R405-2020 INPUT SUMMARY CHECKLI5T REPORT
PROJECT
Title:
CRADY RESIDENCE
Bedrooms: 2
Address Type:
Street Address
Building Type:
User
Conditioned Area: 3486
Lot #
Owner Name:
Total.Stories: 3
Block/SubdiAsion:
# of Units:
1
Worst Case: No
PlatBook
Builder Name:
Rotate Angle: 0
Street:
9507 S INDIAN RIVER
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State,
Zip:
FORT PIERCE,
Family Type:
Detached
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
1263
11240.7
2
AHU 2
2223
24286
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
BATH 2
80
712 No
0
1
Yes
Yes
Yes
2
HVAC CLST
28
249 No
0
1
Yes
Yes
Yes
3
CLST 2
14
125 No
0
1
Yes
Yes
Yes
4
BEDROOM 2
173
1539.7 No
0
1
1
Yes
Yes
Yes
5
LINEN
12
107 No
0
1
Yes
Yes
Yes
6
KITCHENETTE
360
3204 Yes
0
1
Yes
Yes
Yes
7
PANTRY
9
80 No
0
1
No
Yes
Yes
8
LAUNDRY
70
623 No
0
1
Yes
Yes
Yes
9
HALLWAY
102
908 No
0
1
No
Yes
Yes
10
FOYER
220
1958 No
0
1
Yes
Yes
Yes
11
LIVING RM
195
1735 No
0
1
Yes
Yes
Yes
12
STAIRS UP
80
1440 No
0
1
No
Yes
Yes
13
M HALL
63
630 No
0
1
Yes
Yes
Yes
14
M WIC
85
850 No
0
1
No
Yes
Yes
15
AHU 2 CLST
9
90 No
0
1
No
Yes
Yes
16
POWDER RM
45
450 No
0
1
Yes
Yes
Yes
17
M BATH
188
1880 No
0
1
Yes
Yes
Yes
18
MASTER BEDROO
414
4140 No
0
1
1
Yes
Yes
Yes
19
HALL
42
420 - No
0
1
Yes
Yes
Yes
20
DINING RM
272
2421 No
0
1
Yes
Yes
Yes
21
LIVING RM 2ND FL
289
5202 No
0
1
Yes
Yes
Yes
4/16/2021 11:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name Area Volume
Kitchen Occupants
Bedrooms
InfilID
Finished
Cooled
Heated
22
LAUNDRY 2ND FL 144 1440
No 0
1
Yes
Yes
Yes
23
KITCHEN 2ND FLR 252 2520
Yes 0
1
Yes
Yes
Yes
24
LOFT 276 2208
No 0
1
Yes
Yes
Yes
25
M TOILET 28 260
No 0
1
Yes
Yes
Yes
26
POWDER RM LOF 36 335
No 0
1
Yes
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation BATH 2
20 ft
80 ft2
-__
1
0
0
2 Slab -On -Grade Edge Insulation HVAC CLST
4 ft
28 ft2
--
1
0
0
3 Slab -On -Grade Edge Insulation CLST 2
2 ft
14 ft2
____
1
0
0
4 Slab -On -Grade Edge Insulation BEDROOM 2
27 ft
173 ft2
e__
1
0
0
5 Slab -On -Grade Edge Insulation LINEN
6 ft
12 ft2
---
1
0
0
6 Slab -On -Grade Edge Insulation KITCHENETTE
18 ft
360 ft2
____
1
0
0
7 Slab -On -Grade Edge Insulation PANTRY
1 ft
9 ft2
__-
1
0
0
8 Slab -On -Grade Edge Insulation LAUNDRY
7 ft
70 ft2
—
1
0
0
9 Slab -On -Grade Edge Insulation HALLWAY
1 ft
102 ft2
1
0
0
10SIab-On-Grade Edge Insulation FOYER
43 ft
220 ft2
e__
1
0
0
11Slab-On-Grade Edge Insulation LIVING RM
15 ft
195 ft2
____
1
0
0
12Raised Floor STAIRS UP
80 ft2
11
1
0
0
13Raised Floor M HALL
63 ft2
11
1
0
0
14Raised Floor M W IC
-- —
85 ft2
11
1
0
0
15Raised Floor AHU 2 CLST
___ --
9 ft2
11
1
0
0
16Raised Floor POWDER RM
_-
45 ft2
11
1
0
0
17Raised Floor M BATH
— —
188 ft2
11
1
0
0
18Raised Floor MASTER BEDRO
-- --
414 ft2
11
1
0
0
19Raised Floor HALL
s
42 ft2
11
1
0
0
20Raised Floor DINING RM
___ _-
272 ft2
11
1
0
0
21Raised Floor LIVING RM 2ND
289 ft2
11
1
0
0
22Raised Floor LAUNDRY 2ND F
___ --
144 ft2
11
1
0
0
23Raised Floor KITCHEN 2ND FL
—_ —
252 ft2
11
1
0
0
4/16/2021 11:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
24Raised Floor
LOFT
e
276 ft2
11
1 0 0
25Raised Floor
M TOILET e_
28 ft2
11
1 0 0
26Raised Floor
POWDER RM LO ___
_-
36 ft2
11
1 0 0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck Pitch
v #
Type
Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul. (deg)
1
Hip
Metal 4190 ft2
0 ft2
Light
N
0.1
No 0.9
No 20 33.69
ATTIC
V #
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Unvented
0
3486 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented)
BATH 2
0
Blown
80 ft2
0.1
Wood
2
Under Attic (Unvented)
HVAC CLST
0
Blown
28 ft2
0.1
Wood
3
Under Attic (Unvented)
CLST 2
0
Blown
14 ft2
0.1
Wood
4
Under Attic (Unvented)
BEDROOM 2
0
Blown
173 ft2
0.1
Wood
5
Under Attic (Unvented)
LINEN
0
Blown
12 ft2
0.1
Wood
6
Under Attic (Unvented)
KITCHENETTE
0
Blown
360 ft2
0.1
Wood
7
Under Attic (Unvented)
PANTRY
0
Blown
9 ft2
0.1
Wood
8
Under Attic (Unvented)
LAUNDRY
0
Blown
70 ft2
0.1
Wood
9
Under Attic (U nvented)
HALLWAY
0
Blown
102ft2
0.1
Wood
10
Under Attic (Unvented)
FOYER
0
Blown
220 ft2
0.1
Wood
11
Under Attic (Unvented)
LIVING RM
0
Blown
195 ft2
0.1
Woad
12
Under Attic (Unvented)
STAIRS UP
0
Blown
80 ft2
0.1
Wood
13
Under Attic (Unvented)
M HALL
0
Blown
63 ft2
0.1
Wood
14
Under Attic (Unvented)
M WIC
0
Blown
85 ft2
0.1
Wood
15
Under Attic (Unvented)
AHU 2 CLST
0
Blown
9 ft2
0.1
Wood
16
Under Attic (Unvented)
POWDER RM
0
Blown
45 ft2
0.1
Wood
17
Under Attic (Unvented)
M BATH
0
Blown
188 ft2
0.1
Wood
18
Under Attic (Unvented)
MASTER BEDRO
0
Blown
414ft2
0.1
Wood
19
Under Attic (Unvented)
HALL
0
Blown
42 ft2
0.1
Wood
20
Under Attic (Unvented)
DINING RM
0
Blown
272 ft2
0.1
Wood
21
Under Attic (Unvented)
LIVING RM 2ND
0
Blown
289 ft2
0.1
Wood
22
Under Attic (U nvented)
LAUNDRY 2ND F
0
Blown
144ft2
0.1
Wood
23
Under Attic (Unvented)
KITCHEN 2ND FL
0
Blown
252 ft2
0.1
Wood
24
Under Attic (Unvented)
LOFT
0
Blown
276 ft2
0.1
Wood
25
Under Attic (Unvented)
M TOILET
0
Blown
28 ft2
0.1
Wood
- 26
Under Attic (Unvented)
POWDER RM LO
0
Blown
36 ft2
0.1
Wood
4/16/2021 11:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
It
()rot
Adjacent
To
Space
Wall 114pe
Cavity
Width
Height
Sheathing Framing
Solar
Below
1
N
Exterior
Concrete Block- Int Insul BATH 2
4.1
7
0 8
10
61.8 ftz
0
0
0.1
0
2
W
Exterior
Concrete Block - Int Insul BATH 2
4.1
13
0 8
10
114.8 ft2
0
0
0.1
0
3
W
Exterior
Concrete Block - Int InsuHVAC CLST
4.1
4
0 8
10
35.3 ft2
0
0
0.1
0
4
W
Exterior
Concrete Block- Int Insul CLST 2
4.1
2
0 8
10
17.7 ft2
0
0
0.1
0
5
S
Exterior
Concrete Block- Int InsuBEDROOM 2
4.1
13
0 8
10
114.8 ft2
0
0
0.1
0
6
W
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1
14
0 8
10
123.7 ft2
0
0
0.1
0
7
N
Exterior
Concrete Block- Int Insul LINEN
4.1
6
0 8
10
53.0 ft2
0
0
0.1
0
8
S
Exterior
Concrete Block- Int InsLKITCHENETT
4.1
18
0 8
10
159.0 ft2
0
0
0.1
0
9
E
Garage
Frame - Wood KITCHENETT
11
15
0 8
10
132.5 ft2
0
0.1
0.1
0
10
E
Garage
Frame - Wood PANTRY
11
3
0 8
10
26.5 ft2
0
0.1
0.1
0
11
N
Exterior
Concrete Block- Int Insul LAUNDRY
4.1
7
0 8
10
61.8 ft2
0
0
0.1
0
12
E
Garage
Frame - Wood LAUNDRY
11
10
0 8
10
88.3 ft2
0
0.1
0.1
0
13
S
Garage
Frame - Wood LAUNDRY
11
4
0 8
10
35.3 ft2
0
0.1
0.1
0
14
E
Exterior
Concrete Block- Int Insul FOYER
4.1
11
0 8
10
97.2 ft2
0
0
0.1
0
15
S
Exterior
Concrete Block- Int Insul FOYER
4.1
26
0 8
10
229.7 ft2
0
0
0.1
0
16
W
Exterior
Concrete Block - Int Insul FOYER
4.1
6
0 8
10
53.0 ft2
0
0
0.1
0
17
N
Garage
Frame - Wood FOYER
11
26
0 8
10
229.7 ft2
0
0.1
0.1
0
18
N
Exterior
Concrete Block - Int Insul LIVING RM
4.1
15
0 8
10
132.5 ft2
0
0
0.1
0
19
S
Exterior
Concrete Block- Int Insul M HALL
4.1
9
0 10
0
90.0 ft2
0
0
0.1
0
20
N
Exterior
Concrete Block - Int InsuPOWDER R
4.1
5
0 10
0
50.0 ft2
0
0
0.1
0
21
N
Exterior
Concrete Block- Int Insul M BATH
4.1
8
0 10
0
80.0 ft2
0
0
0.1
0
22
E
Exterior
Concrete Block - Int Insul M BATH
4.1
10
0 10
0
100.0 ft2
0
0
0.1
0
23
E
Exterior
Concrete Block - Int InsuMASTER BE
4.1
27
0 10
0
270.0 ft2
0
0
0.1
0
24
S
Exterior
Concrete Block - Int InsuMASTER BE
4.1
18
0 10
0
180.0 ft2
0
0
0.1
0
25
W
Exterior
Concrete Block - Int InsuMASTER BE
4.1
8
0 10
0
80.0 ft2
0
0
0.1
0
26
N
Exterior
Concrete Block - Int Insul HALL
4.1
7
0 10
0
70.0 ft2
0
0
0.1
0
27
N
Exterior
Concrete Block- Int InsuIDINING RM
4.1
17
0 8
10
150.2 ft2
0
0
0.1
0
28
S
Exterior
Concrete Block- Int InsuLIVING RM 2
4.1
17
0 18
0
306.0 ft2
0
0
0.1
0
29
N
Exterior
Concrete Block- Int InsdJAUNDRY 2N
4.1
12
0 10
0
120.0 ft2
0
0
0.1
0
30
W
Exterior
Concrete Block - Int InsdJAUNDRY 2N
4.1
12
0 10
0
120.0 ft2
0
0
0.1
0
31
S
Exterior
Concrete Block - Int InsuKITCHEN 2N
4.1
12
0 10
0
120.0 ft2
0
0
0.1
0
32
W
Exterior
Concrete Block- Int InsuKITCHEN 2N
4.1
21
0 10
0
210.0 ft2
0
0
0.1
0
33
N
Exterior
Concrete Block - Int Insul LOFT
4.1
20
0 8
0
160.0 ft2
0
0
0.1
0
34
E
Exterior
Concrete Block - Int Insul LOFT
4.1
19
0 8
0
152.0 ft2
0
0
0.1
0
35
S
Exterior
Concrete Block- Int Insul LOFT
4.1
4
0 8
0
32.0 ft2
0
0
0.1
0
36
W
Exterior
Concrete Block - Int Insul LOFT
4.1
11
0 8
0
88.0 ft2
0
0
0.1
0
37
N
Exterior
Concrete Block - Int Insul M TOILET
4.1
7
0 9
4
65.3 ft2
0
0
0.1
0
38
E
Exterior
Concrete Block- Int Insul M TOILET
4.1
4
0 9
4
37.3 ft2
0
0
0.1
0
39
N
Exterior
Concrete Block - Int InsuPOW DER R
4.1
6
0 9
4
56.0 ft2
0
0
0.1
0
40
E
Exterior
Concrete Block - Int InsuPOWDER R
4.1
6
0 9
4
56.0 ft2
0
0
0.1
0
41
S
Exterior
Concrete Block - Int InsuPOW DER R
4.1
6
0 9
4
56.0 ft2
0
0
0.1
0
[l
4/16/2021 11:43 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated
FOYER
None
.23
3
8
24 ftz
2
E
Insulated
LAUNDRY
None
.23
3
8
24 ftz
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Omt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
W
2
Metal
Low-E Single
Yes
0.45 0.25
Y
15.0 ftz
1 ft 6 in
1 ft 4 in
None
None
2
S
5
Metal
Low-E Single
Yes
0.45 0.25
Y
24.0 ftz
1 ft 6 in
1 ft 4 in
Drapesiblinds
Exterior 5
3
W
6
Metal
Low-E Single
Yes
0.45 0.25
Y
36.0 ftz
1 ft 6 in
1 ft 4 in
Drapesiblinds
Exterior 5
4
S
8
Metal
Low-E Single
Yes
0.45 0.25
Y
96.0 ftz
13 ft 6 in
1 ft 4 in
None
None
5
S
15
Metal
Low-E Single
Yes
0.45 0.25
Y
30.0 ft'
1 ft 6 in
1 ft 4 in
None
None
6
N
20
Metal
Low-E Single
Yes
0.45 0.25
Y
10.0 ftz
1 ft 6 in
1 ft 4 in
None
None
7
N
21
Metal
Low-E Single
Yes
0.45 0.25
Y
20.0 ftz
1 ft 6 in
1 ft 4 in
None
None
8
E
22
Metal
Low-E Single
Yes
0.45 0.25
Y
10.0 ftz
1 ft 6 in
1 ft 4 in
None
None
9
E
23
Metal
Low-E Single
Yes
0.45 0.25
Y
54.0 ft'
1 ft 6 in
1 ft 4 in
None
None
10
S
24
Metal
Low-E Single
Yes
0.45 0.25
Y '
30.0 ftz
1 ft 6 in
1 ft 4 in
None
None
11
W
25
Metal
Low-E Single
Yes
0.45 0.25
Y
24.0 ftz
6 ft 6 in
1 ft 4 in
None
None
12
N
27
Metal
Low-E Single
Yes
0.45 0.25
Y
72.0 ftz
9 ft 6 in
1 ft 4 in
None
None
13
N
27
Metal
Low-E Single
Yes
0.45 0.25
Y
24.0 ftz
9 ft 6 in
1 ft 4 in
None
None
14
S
28
Metal
Low-E Single
Yes
0.45 0.25
Y
96.0 ftz
13 ft 6 in
1 ft 4 in
None
None
15
N
29
Metal
Low-E Single
Yes
0.45 0.25
Y
15.0 ftz
1 ft 6 in
1 ft 4 in
None
None
16
W
30
Metal
Low-E Single
Yes
0.45 0.25
Y
15.0 ftz
1 ft 6 in
1 ft 4 in
None
None
17
W
32
Metal
Low-E Single
Yes
0.45 0.25
Y
30.0 ftz
1 ft 6 in
1 ft 4 in
None
None
18
N
33
Metal
Low-E Single
Yes
0.45 0.25
Y
80.0 ftZ
6 ft 6 in
1 ft4 in
None
None
19
N
37
Metal
Low-E Single
Yes
0.45 0.25
Y
10.0 ftz
1 ft 6 in
1 ft4 in
None
None
20
E
38
Metal
Low-E Single
Yes
0.45 0.25
Y
10.0 ftz
1 ft 6 in
1 ft4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
616ftz
616ftz
54ft
9ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 W holehouse
Proposed ACH(50) .000324
2960.6 162.43
304.93
.1543
5
4/16/2021 11:43 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1
17 kBtu/hr
1
sys#1
2 Electric Strip Heat/
None
COPA
34 kBtu/hr
2
sys#2
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 16
18 kBtu/hr
540 cfm
0.8
1
sys#1
2 Central Unit/
Split
Single SEER: 15
47 kBtu/hr
1410 cfm
0.8
2
sys#2
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.98 50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
/ — Supply---
— - Return---
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic 6 125 ft2
Attic
13 ft2 Prop. Leak Free
HVAC CLS
— cfm
37.9 cfm 0.03
0.50
1 1
2 Attic 6 200 ft2
Attic
20 1`12 Prop. Leak Free
AHU 2 CLS
—cfm
66.7 cfm 0.03
0.50
2 2
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan Feb Mar
HeatinJan Feb Mar
Apr
Apr
May Jun Jul
May Jun Jul
Auge
4 Aug
Sep
Oct
Oct
Nov
Nov
Dec
Dec
Venting Jan Feb Mar
Apr
May Jun Jul
[ Aug
Sep
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 80
80 78 78
78
78
78
78
78
78
Cooling (W EH) AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 80
80 78 78
78
78
78
78
78
78
Heating (WD) AM 65
65 65
65 65 65
65
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
68
68
Heating (WEH) AM 65
65 65
65 65 65
65
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HVAC CLST
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
LINEN
4/16/2021 11:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHENETTE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STAIRS UP
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU 2 CLST
Default(81bs/sq.ft.
ft2
ft
0.3
POWDER RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING RM 2ND FL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY 2ND FL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN 2ND FLR
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LOFT
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/s .ft.
ft2
ft
0.3
POWDER RM LOF