Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 RECEIVED JUN 2 5 2021 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDIROrt 14STRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CRADY RESIDENCE Builder Name: Street: 9507 S INDIAN RIVER DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�4415.5 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 3903.20 ft2 b. Frame - Wood, Adjacent R=11.0 512.33 ftz 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 11. Ceiling Types (3486.0 sqft) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 3486.00 ft2 6. Conditioned floor area above grade (ft2) 3486 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(701.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: HVAC CLST R ft2 6 125 a. U-Factor: Sgl, U=0.45 701.00 ft2 b. Sup: Attic, Ret: Attic, AH: AHU 2 CLST 6 200 SHGC: SHGC=0.25 b. U-Factor. N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 18.0 SEER.16.00 c. U-Factor: N/A ft2 b. Central Unit 47.0 SEER:15.00 SHGC: Area Weighted Average Overhang Depth: 6.624 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 17.0 COPA.00 b. Electric Strip Heat 34.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (3486.0 sqft.) Insulation Area EF: 0.980 a. Raised Floor R=11.0 2223.00 ft2 b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 1263.00 ft2 None c. N/A R= ft2 16. Credits None Total Proposed Modified Loads: 125.39 Glass/Floor Area: 0.201 PASS Total Baseline Loads: 125.57 I hereby certify that the plans and specifications covered by Review of the plans and 0� ST,gT�. this calculation are in compliance with the Florida Energy specifications covered by this .Ati 0�, Code. calculation indicates compliance y` ray '' w - �.���� 0'` with the Florida Energy Code. PREPA E Bxy - - DATE. �9 Z� Before construction is completed this building will be inspected for compliance with Section 553.908 0 I hereby certify that this building, as des' ned, is in compliance Florida Statutes. 5<S G'OD with the Florida Energ Code. WF.flt� ` 0WNER/AGE T � V BUILDING OFFICIAL: DATE: ® C -- 4 K--- Q .0 -z DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, =tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. r 4/16/2021 11:43 AM EnergyGauge® USA 7:0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 8 FORM R405-2020 INPUT SUMMARY CHECKLI5T REPORT PROJECT Title: CRADY RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 3486 Lot # Owner Name: Total.Stories: 3 Block/SubdiAsion: # of Units: 1 Worst Case: No PlatBook Builder Name: Rotate Angle: 0 Street: 9507 S INDIAN RIVER Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 1263 11240.7 2 AHU 2 2223 24286 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BATH 2 80 712 No 0 1 Yes Yes Yes 2 HVAC CLST 28 249 No 0 1 Yes Yes Yes 3 CLST 2 14 125 No 0 1 Yes Yes Yes 4 BEDROOM 2 173 1539.7 No 0 1 1 Yes Yes Yes 5 LINEN 12 107 No 0 1 Yes Yes Yes 6 KITCHENETTE 360 3204 Yes 0 1 Yes Yes Yes 7 PANTRY 9 80 No 0 1 No Yes Yes 8 LAUNDRY 70 623 No 0 1 Yes Yes Yes 9 HALLWAY 102 908 No 0 1 No Yes Yes 10 FOYER 220 1958 No 0 1 Yes Yes Yes 11 LIVING RM 195 1735 No 0 1 Yes Yes Yes 12 STAIRS UP 80 1440 No 0 1 No Yes Yes 13 M HALL 63 630 No 0 1 Yes Yes Yes 14 M WIC 85 850 No 0 1 No Yes Yes 15 AHU 2 CLST 9 90 No 0 1 No Yes Yes 16 POWDER RM 45 450 No 0 1 Yes Yes Yes 17 M BATH 188 1880 No 0 1 Yes Yes Yes 18 MASTER BEDROO 414 4140 No 0 1 1 Yes Yes Yes 19 HALL 42 420 - No 0 1 Yes Yes Yes 20 DINING RM 272 2421 No 0 1 Yes Yes Yes 21 LIVING RM 2ND FL 289 5202 No 0 1 Yes Yes Yes 4/16/2021 11:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 LAUNDRY 2ND FL 144 1440 No 0 1 Yes Yes Yes 23 KITCHEN 2ND FLR 252 2520 Yes 0 1 Yes Yes Yes 24 LOFT 276 2208 No 0 1 Yes Yes Yes 25 M TOILET 28 260 No 0 1 Yes Yes Yes 26 POWDER RM LOF 36 335 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BATH 2 20 ft 80 ft2 -__ 1 0 0 2 Slab -On -Grade Edge Insulation HVAC CLST 4 ft 28 ft2 -- 1 0 0 3 Slab -On -Grade Edge Insulation CLST 2 2 ft 14 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation BEDROOM 2 27 ft 173 ft2 e__ 1 0 0 5 Slab -On -Grade Edge Insulation LINEN 6 ft 12 ft2 --- 1 0 0 6 Slab -On -Grade Edge Insulation KITCHENETTE 18 ft 360 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulation PANTRY 1 ft 9 ft2 __- 1 0 0 8 Slab -On -Grade Edge Insulation LAUNDRY 7 ft 70 ft2 — 1 0 0 9 Slab -On -Grade Edge Insulation HALLWAY 1 ft 102 ft2 1 0 0 10SIab-On-Grade Edge Insulation FOYER 43 ft 220 ft2 e__ 1 0 0 11Slab-On-Grade Edge Insulation LIVING RM 15 ft 195 ft2 ____ 1 0 0 12Raised Floor STAIRS UP 80 ft2 11 1 0 0 13Raised Floor M HALL 63 ft2 11 1 0 0 14Raised Floor M W IC -- — 85 ft2 11 1 0 0 15Raised Floor AHU 2 CLST ___ -- 9 ft2 11 1 0 0 16Raised Floor POWDER RM _- 45 ft2 11 1 0 0 17Raised Floor M BATH — — 188 ft2 11 1 0 0 18Raised Floor MASTER BEDRO -- -- 414 ft2 11 1 0 0 19Raised Floor HALL s 42 ft2 11 1 0 0 20Raised Floor DINING RM ___ _- 272 ft2 11 1 0 0 21Raised Floor LIVING RM 2ND 289 ft2 11 1 0 0 22Raised Floor LAUNDRY 2ND F ___ -- 144 ft2 11 1 0 0 23Raised Floor KITCHEN 2ND FL —_ — 252 ft2 11 1 0 0 4/16/2021 11:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 24Raised Floor LOFT e 276 ft2 11 1 0 0 25Raised Floor M TOILET e_ 28 ft2 11 1 0 0 26Raised Floor POWDER RM LO ___ _- 36 ft2 11 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 4190 ft2 0 ft2 Light N 0.1 No 0.9 No 20 33.69 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 3486 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BATH 2 0 Blown 80 ft2 0.1 Wood 2 Under Attic (Unvented) HVAC CLST 0 Blown 28 ft2 0.1 Wood 3 Under Attic (Unvented) CLST 2 0 Blown 14 ft2 0.1 Wood 4 Under Attic (Unvented) BEDROOM 2 0 Blown 173 ft2 0.1 Wood 5 Under Attic (Unvented) LINEN 0 Blown 12 ft2 0.1 Wood 6 Under Attic (Unvented) KITCHENETTE 0 Blown 360 ft2 0.1 Wood 7 Under Attic (Unvented) PANTRY 0 Blown 9 ft2 0.1 Wood 8 Under Attic (Unvented) LAUNDRY 0 Blown 70 ft2 0.1 Wood 9 Under Attic (U nvented) HALLWAY 0 Blown 102ft2 0.1 Wood 10 Under Attic (Unvented) FOYER 0 Blown 220 ft2 0.1 Wood 11 Under Attic (Unvented) LIVING RM 0 Blown 195 ft2 0.1 Woad 12 Under Attic (Unvented) STAIRS UP 0 Blown 80 ft2 0.1 Wood 13 Under Attic (Unvented) M HALL 0 Blown 63 ft2 0.1 Wood 14 Under Attic (Unvented) M WIC 0 Blown 85 ft2 0.1 Wood 15 Under Attic (Unvented) AHU 2 CLST 0 Blown 9 ft2 0.1 Wood 16 Under Attic (Unvented) POWDER RM 0 Blown 45 ft2 0.1 Wood 17 Under Attic (Unvented) M BATH 0 Blown 188 ft2 0.1 Wood 18 Under Attic (Unvented) MASTER BEDRO 0 Blown 414ft2 0.1 Wood 19 Under Attic (Unvented) HALL 0 Blown 42 ft2 0.1 Wood 20 Under Attic (Unvented) DINING RM 0 Blown 272 ft2 0.1 Wood 21 Under Attic (Unvented) LIVING RM 2ND 0 Blown 289 ft2 0.1 Wood 22 Under Attic (U nvented) LAUNDRY 2ND F 0 Blown 144ft2 0.1 Wood 23 Under Attic (Unvented) KITCHEN 2ND FL 0 Blown 252 ft2 0.1 Wood 24 Under Attic (Unvented) LOFT 0 Blown 276 ft2 0.1 Wood 25 Under Attic (Unvented) M TOILET 0 Blown 28 ft2 0.1 Wood - 26 Under Attic (Unvented) POWDER RM LO 0 Blown 36 ft2 0.1 Wood 4/16/2021 11:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS It ()rot Adjacent To Space Wall 114pe Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block- Int Insul BATH 2 4.1 7 0 8 10 61.8 ftz 0 0 0.1 0 2 W Exterior Concrete Block - Int Insul BATH 2 4.1 13 0 8 10 114.8 ft2 0 0 0.1 0 3 W Exterior Concrete Block - Int InsuHVAC CLST 4.1 4 0 8 10 35.3 ft2 0 0 0.1 0 4 W Exterior Concrete Block- Int Insul CLST 2 4.1 2 0 8 10 17.7 ft2 0 0 0.1 0 5 S Exterior Concrete Block- Int InsuBEDROOM 2 4.1 13 0 8 10 114.8 ft2 0 0 0.1 0 6 W Exterior Concrete Block - Int InsuBEDROOM 2 4.1 14 0 8 10 123.7 ft2 0 0 0.1 0 7 N Exterior Concrete Block- Int Insul LINEN 4.1 6 0 8 10 53.0 ft2 0 0 0.1 0 8 S Exterior Concrete Block- Int InsLKITCHENETT 4.1 18 0 8 10 159.0 ft2 0 0 0.1 0 9 E Garage Frame - Wood KITCHENETT 11 15 0 8 10 132.5 ft2 0 0.1 0.1 0 10 E Garage Frame - Wood PANTRY 11 3 0 8 10 26.5 ft2 0 0.1 0.1 0 11 N Exterior Concrete Block- Int Insul LAUNDRY 4.1 7 0 8 10 61.8 ft2 0 0 0.1 0 12 E Garage Frame - Wood LAUNDRY 11 10 0 8 10 88.3 ft2 0 0.1 0.1 0 13 S Garage Frame - Wood LAUNDRY 11 4 0 8 10 35.3 ft2 0 0.1 0.1 0 14 E Exterior Concrete Block- Int Insul FOYER 4.1 11 0 8 10 97.2 ft2 0 0 0.1 0 15 S Exterior Concrete Block- Int Insul FOYER 4.1 26 0 8 10 229.7 ft2 0 0 0.1 0 16 W Exterior Concrete Block - Int Insul FOYER 4.1 6 0 8 10 53.0 ft2 0 0 0.1 0 17 N Garage Frame - Wood FOYER 11 26 0 8 10 229.7 ft2 0 0.1 0.1 0 18 N Exterior Concrete Block - Int Insul LIVING RM 4.1 15 0 8 10 132.5 ft2 0 0 0.1 0 19 S Exterior Concrete Block- Int Insul M HALL 4.1 9 0 10 0 90.0 ft2 0 0 0.1 0 20 N Exterior Concrete Block - Int InsuPOWDER R 4.1 5 0 10 0 50.0 ft2 0 0 0.1 0 21 N Exterior Concrete Block- Int Insul M BATH 4.1 8 0 10 0 80.0 ft2 0 0 0.1 0 22 E Exterior Concrete Block - Int Insul M BATH 4.1 10 0 10 0 100.0 ft2 0 0 0.1 0 23 E Exterior Concrete Block - Int InsuMASTER BE 4.1 27 0 10 0 270.0 ft2 0 0 0.1 0 24 S Exterior Concrete Block - Int InsuMASTER BE 4.1 18 0 10 0 180.0 ft2 0 0 0.1 0 25 W Exterior Concrete Block - Int InsuMASTER BE 4.1 8 0 10 0 80.0 ft2 0 0 0.1 0 26 N Exterior Concrete Block - Int Insul HALL 4.1 7 0 10 0 70.0 ft2 0 0 0.1 0 27 N Exterior Concrete Block- Int InsuIDINING RM 4.1 17 0 8 10 150.2 ft2 0 0 0.1 0 28 S Exterior Concrete Block- Int InsuLIVING RM 2 4.1 17 0 18 0 306.0 ft2 0 0 0.1 0 29 N Exterior Concrete Block- Int InsdJAUNDRY 2N 4.1 12 0 10 0 120.0 ft2 0 0 0.1 0 30 W Exterior Concrete Block - Int InsdJAUNDRY 2N 4.1 12 0 10 0 120.0 ft2 0 0 0.1 0 31 S Exterior Concrete Block - Int InsuKITCHEN 2N 4.1 12 0 10 0 120.0 ft2 0 0 0.1 0 32 W Exterior Concrete Block- Int InsuKITCHEN 2N 4.1 21 0 10 0 210.0 ft2 0 0 0.1 0 33 N Exterior Concrete Block - Int Insul LOFT 4.1 20 0 8 0 160.0 ft2 0 0 0.1 0 34 E Exterior Concrete Block - Int Insul LOFT 4.1 19 0 8 0 152.0 ft2 0 0 0.1 0 35 S Exterior Concrete Block- Int Insul LOFT 4.1 4 0 8 0 32.0 ft2 0 0 0.1 0 36 W Exterior Concrete Block - Int Insul LOFT 4.1 11 0 8 0 88.0 ft2 0 0 0.1 0 37 N Exterior Concrete Block - Int Insul M TOILET 4.1 7 0 9 4 65.3 ft2 0 0 0.1 0 38 E Exterior Concrete Block- Int Insul M TOILET 4.1 4 0 9 4 37.3 ft2 0 0 0.1 0 39 N Exterior Concrete Block - Int InsuPOW DER R 4.1 6 0 9 4 56.0 ft2 0 0 0.1 0 40 E Exterior Concrete Block - Int InsuPOWDER R 4.1 6 0 9 4 56.0 ft2 0 0 0.1 0 41 S Exterior Concrete Block - Int InsuPOW DER R 4.1 6 0 9 4 56.0 ft2 0 0 0.1 0 [l 4/16/2021 11:43 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated FOYER None .23 3 8 24 ftz 2 E Insulated LAUNDRY None .23 3 8 24 ftz WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 2 Metal Low-E Single Yes 0.45 0.25 Y 15.0 ftz 1 ft 6 in 1 ft 4 in None None 2 S 5 Metal Low-E Single Yes 0.45 0.25 Y 24.0 ftz 1 ft 6 in 1 ft 4 in Drapesiblinds Exterior 5 3 W 6 Metal Low-E Single Yes 0.45 0.25 Y 36.0 ftz 1 ft 6 in 1 ft 4 in Drapesiblinds Exterior 5 4 S 8 Metal Low-E Single Yes 0.45 0.25 Y 96.0 ftz 13 ft 6 in 1 ft 4 in None None 5 S 15 Metal Low-E Single Yes 0.45 0.25 Y 30.0 ft' 1 ft 6 in 1 ft 4 in None None 6 N 20 Metal Low-E Single Yes 0.45 0.25 Y 10.0 ftz 1 ft 6 in 1 ft 4 in None None 7 N 21 Metal Low-E Single Yes 0.45 0.25 Y 20.0 ftz 1 ft 6 in 1 ft 4 in None None 8 E 22 Metal Low-E Single Yes 0.45 0.25 Y 10.0 ftz 1 ft 6 in 1 ft 4 in None None 9 E 23 Metal Low-E Single Yes 0.45 0.25 Y 54.0 ft' 1 ft 6 in 1 ft 4 in None None 10 S 24 Metal Low-E Single Yes 0.45 0.25 Y ' 30.0 ftz 1 ft 6 in 1 ft 4 in None None 11 W 25 Metal Low-E Single Yes 0.45 0.25 Y 24.0 ftz 6 ft 6 in 1 ft 4 in None None 12 N 27 Metal Low-E Single Yes 0.45 0.25 Y 72.0 ftz 9 ft 6 in 1 ft 4 in None None 13 N 27 Metal Low-E Single Yes 0.45 0.25 Y 24.0 ftz 9 ft 6 in 1 ft 4 in None None 14 S 28 Metal Low-E Single Yes 0.45 0.25 Y 96.0 ftz 13 ft 6 in 1 ft 4 in None None 15 N 29 Metal Low-E Single Yes 0.45 0.25 Y 15.0 ftz 1 ft 6 in 1 ft 4 in None None 16 W 30 Metal Low-E Single Yes 0.45 0.25 Y 15.0 ftz 1 ft 6 in 1 ft 4 in None None 17 W 32 Metal Low-E Single Yes 0.45 0.25 Y 30.0 ftz 1 ft 6 in 1 ft 4 in None None 18 N 33 Metal Low-E Single Yes 0.45 0.25 Y 80.0 ftZ 6 ft 6 in 1 ft4 in None None 19 N 37 Metal Low-E Single Yes 0.45 0.25 Y 10.0 ftz 1 ft 6 in 1 ft4 in None None 20 E 38 Metal Low-E Single Yes 0.45 0.25 Y 10.0 ftz 1 ft 6 in 1 ft4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 616ftz 616ftz 54ft 9ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 W holehouse Proposed ACH(50) .000324 2960.6 162.43 304.93 .1543 5 4/16/2021 11:43 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COPA 34 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 18 kBtu/hr 540 cfm 0.8 1 sys#1 2 Central Unit/ Split Single SEER: 15 47 kBtu/hr 1410 cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply--- — - Return--- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 125 ft2 Attic 13 ft2 Prop. Leak Free HVAC CLS — cfm 37.9 cfm 0.03 0.50 1 1 2 Attic 6 200 ft2 Attic 20 1`12 Prop. Leak Free AHU 2 CLS —cfm 66.7 cfm 0.03 0.50 2 2 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb Mar HeatinJan Feb Mar Apr Apr May Jun Jul May Jun Jul Auge 4 Aug Sep Oct Oct Nov Nov Dec Dec Venting Jan Feb Mar Apr May Jun Jul [ Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HVAC CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 LINEN 4/16/2021 11:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHENETTE Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 STAIRS UP Default(8 Ibs/sq.ft. ft2 ft 0.3 M HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU 2 CLST Default(81bs/sq.ft. ft2 ft 0.3 POWDER RM Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING RM 2ND FL Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY 2ND FL Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN 2ND FLR Default(8 Ibs/sq.ft. ft2 ft 0.3 LOFT Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/s .ft. ft2 ft 0.3 POWDER RM LOF 4/16/2021 11:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 8 of 8