Loading...
HomeMy WebLinkAboutCertainteed Evaluation Report - Tapered (1)(1) ESCC IMES Evaluation Report ESR-1388 Reissued May 2020 This report is subject to renewal May 2021. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00-THERMAL AND MOISTURE impregnated and covered with SBS modified bitumen. The PROTECTION membrane is a Type I, Grade G, membrane complying Section: 07 52 00-Modified Bituminous Sheet Roofing with ASTM D6163 and intended for adhesive or hot asphalt application. The membrane weighs approximately REPORT HOLDER: 7.2 pounds per square yard (3.9 kg/m2). The membrane is also available as a CoolStar option, which utilizes bright CERTAINTEED LLC white granules. EVALUATION SUBJECT: 3.2.2 Flintlastic FR-P (Standard or CoolStarfflintlastic FR-P is a 0.17-inch-thick (4.3 mm), granular-surfaced, CERTAINTEED FLINTLASTIC MODIFIED BITUMEN reinforced, SBS modified bitumen roofing membrane ROOF COVERING SYSTEMS manufactured from a nonwoven polyester fabric impregnated and covered with SBS modified bitumen. The 1.0 EVALUATION SCOPE membrane is a Type I, Grade G, membrane complying with ASTM D6164 and intended for adhesive or hot Compliance with the following codes: asphalt application. The membrane weighs approximately ■ 2018, 2015, 2012 and 2009 International Building 8.4 pounds per square yard (4.6 kg/m2). The membrane is Code®(IBC) also available as a CoolStar option, which utilizes bright white granules. ■ 2018, 2015, 2012 and 2009 International Residential 3.2.3 Flintlastic Premium FR-P (Standard or Code°(I RC) CoolStar): Flintlastic Premium FR-P is a 0.17-inch-thick Properties evaluated: (4.3 mm), mineral-surfaced, reinforced, SBS modified ■ Fire classification bitumen roofing membrane manufactured from a nonwoven polyester fabric impregnated and covered with ■ Wind uplift resistance SBS modified bitumen. The membrane is a Type II, ■ Physical properties Grade G, membrane complying with ASTM D6164 and intended for adhesive or hot asphalt application. The ■ Impact resistance membrane weighs approximately 8.4 pounds per square 2.0 USES yard (4.6 kg/m2). The membrane is also available as a The CertainTeed Flintlastic modified bitumen roof covering CoolStar option, which utilizes bright white granules. membranes are used as roof coverings in Class A, B or C 3.2.4 Flintlastic GTS (Standard or CoolStar): Flintlastic roof covering systems, described in this report, on new or GTS is a 0.176-inch-thick (4.5 mm), granular-surfaced, existing roofs. reinforced, SBS modified bitumen roofing membrane manufactured from a nonwoven polyester fabric 3.0 DESCRIPTION impregnated and covered with SBS modified bitumen. The 3.1 General: membrane is a Type II, Grade G, membrane complying CertainTeed roofing membranes are atactic polypropylene with ASTM D6164 and intended for torch application only. (APP) or styrene butadiene styrene (SBS) modified The membrane weighs approximately 9.9 pounds per square yard (5.4 kg/m2). The membrane is also available bitumen membranes complying with ASTM D6222,ASTM D6162, ASTM D6163 or ASTM D6164, as as a CoolStar option,which utilizes bright white granules. applicable. Roof covering systems utilizing CertainTeed 3.2.5 Flintlastic GMS (Standard or CoolStar): roofing membranes consist of single-ply membranes, base Flintlastic GMS is a 0.17-inch-thick (4.3 mm), granular- sheets and ply sheets, approved insulation, flashing, surfaced, reinforced, SBS modified bitumen roofing asphalts, adhesives, coatings and mechanical fasteners membrane manufactured from a nonwoven polyester fabric that are installed to produce an integrated roof system. impregnated and covered with SBS modified bitumen. The membrane is a Type I, Grade G, membrane 3.2 Membranes: g comp I Y In with ASTM D6164 and intended for adhesive 3.2.1 Flintlastic FR Cap 30 (Standard or CoolStar): or hot asphalt application. The membrane weighs Flintlastic FR Cap 30 is a 0.138-inch-thick (3.5 mm), approximately 8.0 pounds per square yard (4.4 kg/m2). granular-surfaced, reinforced, SBS modified bitumen The membrane is also available as a CoolStar option, roofing membrane manufactured from a glass fiber mat which utilizes bright white granules. ICGES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty,by ICC Evaluation Service,LLC,express or implied,as i to any finding or other matter-in this report,or as to any product covered by the report ���r cooEcou°;iii „o, Copyright©2020 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 27 ESR-1388 1 Most Widely Accepted and Trusted Page 2 of 27 3.2.6 Flintlastic Premium GMS(Standard or CoolStar): compound. The membrane is a Type I, Grade G Flintlastic Premium GMS is a 0.17-inch-thick (4.3 mm), membrane complying with ASTM D6164 and is intended granular-surfaced, reinforced, SBS modified bitumen for self-adhered application only. The membrane weighs roofing membrane manufactured from a nonwoven approximately 95 pounds per roll. The membrane is also polyester fabric impregnated and covered with SIBS available as a CoolStar option, which utilizes bright white modified bitumen. The membrane is a Type II, Grade G, granules. membrane complying with ASTM D6164 and intended for adhesive or hot asphalt application. The membrane weighs 3.2.13 Flintlastic FR Cap 30 T (Standard or CoolStar):(3.8 Flintlastic FR Cap 30 T is a 0.15-inch-thick 3.8 mm), approximately 8.4 pounds per square yard (4.6 kg/m2). The granular-surfaced, reinforced, SBS modified bitumen membrane is also available as a CoolStar option, which utilizes bright white granules. roofing membrane manufactured from a glass fiber mat impregnated and covered with SBS modified bitumen. 3.2.7 Flintlastic STA: Flintlastic STA is a 0.16-inch-thick The membrane is a Type I, Grade G membrane complying (4 mm), smooth-talc-surfaced, reinforced, APP modified with ASTM D6163 and is intended for torch application bitumen roofing membrane. Flintlastic STA is used as a only. The membrane weighs approximately 8.1 pounds per cap sheet or ply sheet and is manufactured from a square yard (4.4 kg/m2). The membrane is also available nonwoven polyester fabric impregnated and covered with as a CoolStar option, which utilizes bright white granules. APP modified bitumen. The membrane is a Type I, Grade S, membrane complying with ASTM D6222 and 3.3 Insulation: intended for torch application only. The membrane weighs Foam plastic insulation, where used, must have a approximately 7.4 pounds per square yard (4.0 kg/m2). flame-spread index of not more than 75 when tested, at the 3.2.8 Flintlastic STA Plus: Flintlastic STA Plus is a maximum thickness intended for use, in accordance with 0.18-inch-thick (4.5 mm), smooth-talc-surfaced, reinforced, UL 723 or ASTM E84. See Tables 1A, 1C and 2A through APP modified bitumen roofing membrane. The membrane 2F for insulations permitted for use with specific roofing is used as a cap sheet or ply sheet and is manufactured systems. from a nonwoven polyester fabric impregnated and 3.4 Fasteners: covered with APP modified bitumen. The membrane is a Type I, Grade S, membrane complying with ASTM D6222 Fasteners and plates used to mechanically fasten and intended for torch application only. The membrane insulation and base sheets must be in accordance with weighs approximately 8.1 pounds per square yard Table 3 unless otherwise noted. (4.4 kg/m2). 3.5 Adhesives: 3.2.9 Flintlastic GTA (Standard or CoolStar): Flintlastic GTA is a 0.16-inch-thick (4 mm), granular-surfaced, See Table 2F, footnote 5, for adhesives and coverage reinforced, APP modified bitumen roofing membrane rates. manufactured from a nonwoven polyester fabric 3.6 Impact Resistance: impregnated and covered with APP modified bitumen. The membrane is a Type I, Grade G, membrane complying The CertainTeed Flintlastic modified bitumen roof with ASTM D6222 and intended for torch application only. coverings described in this report meet the requirement The membrane weighs approximately 7.8 pounds per for impact resistance in accordance with Section 4.6 of square yard (4.2 kg/m2). The membrane is also available FM 4470. as a CoolStar option,which utilizes bright white granules. 4.0 INSTALLATION 3.2.10 Flintlastic GTA-FR (Standard or CoolStar): 4.1 General: Flintlastic GTA-FR is a 0.160-inch-thick (4.1 mm), granular-surfaced, reinforced, APP modified bitumen Installation of the CertainTeed Flintlastic membrane roof roofing membrane manufactured from a nonwoven covering systems described in this report must comply polyester fabric impregnated and covered with APP with the applicable code, the manufacturer's published modified bitumen. The membrane is a Type I, Grade G, installation instructions and this report. The manufacturer's membrane complying with ASTM D6222 and intended for published installation instructions must be available at all torch application only. The membrane weighs times on the jobsite during installation. CertainTeed approximately 8.6 pounds per square yard (4.7 kg/m2). Flintlastic roofing membranes are components of roof The membrane is also available as a CoolStar option, covering systems that may be installed over new or which utilizes bright white granules. existing roofs as described in Tables 1A through 1 D and 3.2.11 Flintlastic SA Cap-FR (Standard or CoolStar): 2A through 2F. Flintlastic SA Cap FR is a 0.125-inch-thick (3.2 mm), The roof slope must be a minimum Of '/4:12 (2 percent granular-surfaced, reinforced, SIBS modified bitumen slope) and must not be more than maximum slope for the roofing membrane manufactured from a glass fiber mat particular system as specified in Tables 1 A through 1 D. impregnated and covered with SBS modified bitumen. The membrane is a Type I, Grade G membrane complying Penetrations and terminations of the roof covering must with ASTM D6163 and is intended for self-adhered be flashed and made weathertight in accordance with the application only. The membrane weighs approximately CertainTeed LLC's published installation instructions and 7.3 pounds per square yard (4.0 kg/m2). The membrane is the applicable code. also available as a CoolStar option, which utilizes bright 4.2 Fire Classification: white granules. 3.2.12 Flintlastic SA Cap (Standard or CoolStar): 4.2.1 New Construction: Roof covering systems Flintlastic SA Cap is a 0.16-inch-thick (4.0 mm), described in Tables 1A through 1D, when installed in granular-surfaced, reinforced, SIBS modified bitumen accordance with this report, are Class A, B or C roof roofing membrane manufactured from a non-woven coverings in accordance with ASTM El08 or UL 790. polyester/fiber glass scrim combination mat, impregnated 4.2.2 Reroofing: Prior to installation of new roof and coated with a superior grade of modified bitumen coverings, inspection in accordance with 2018 IBC Section ESR-1388 1 Most Widely Accepted and Trusted Page 3 of 27 1511 [2015, 2012 and 2009 IBC Section 1510] and 2018 when tested at the maximum thickness intended for IRC Section R908 [2015, 2012 and 2009 IRC Section use in accordance with ASTM E84 or UL 723, subject R907], and approval from the code official having to the approval of the code official. Except for jurisdiction, are required. applications where a thermal barrier is not required, Class A, B or C roof covering systems may be installed total thickness of foam plastic insulation must be over existing roof coverings without additional roof limited to the lesser of the maximum thickness classification tests, provided the resulting classification is allowed in Tables 1A, 1C and 2A through 2F or the the lower of the new and existing roofing classifications maximum thickness that limits the flame-spread index under the following conditions: to not more than 75 when testing is in accordance with ASTM E84 or UL 723, subject to the approval of ■ New uninsulated systems installed only over existing the code official. uninsulated systems 5.6 Design wind uplift pressure on any roof area, ■ New insulated systems installed over existing including edge and corner zones, must not exceed uninsulated systems only the allowable wind uplift pressure for the roof covering 4.3 Wind Uplift Resistance: installed in that particular area. Refer to allowable wind uplift pressure shown in Tables 2A through 2F. 4.3.1 New Construction: The CertainTeed Flintlastic 5.7 Above-deck thermal insulation board must comply membrane roof covering systems described in this report with the applicable standards listed in IBC have a maximum allowable wind uplift capacity as shown Table 1508.2 and IRC Table R906.2. in Tables 2A through 2F. Metal edge securement systems must be listed in accordance with the 2011 edition of 5.8 The allowable wind-uplift pressures shown in ANSI/SPRI/FM4435 ES-1, and designed and installed in Tables 2A through 2F are for the roof covering only. accordance with 2018 and 2015 IBC Section 1504.5 and The deck and framing to which the roof covering is IBC Chapter 16 [2003 edition of ANSI/SPRI ES-1, and attached must be designed for the applicable designed and installed in accordance with 2012 and 2009 components, and cladding wind loads in accordance IBC Section 1504.5 and 2012 and 2009 IBC Chapter 16]. with the applicable code. 4.3.2 Reroofing: Roof covering systems employing 5.9 Calculations demonstrating that the required wind mechanical fasteners must be qualified, to the satisfaction resistance is less than the allowable wind resistance of the code official, on adequacy of fasteners penetrating must be submitted to the code official. through existing roof coverings into structural substrates. 5.10 When application is over existing roofs, Since the composition and/or condition of any particular documentation of the wind-uplift resistance of the underlying existing roofing material can vary widely, composite roof construction must be submitted to reroofing with adhered systems is outside the scope of this the code official at the time of permit application. report. 5.0 CONDITIONS OF USE 5.11 The membranes are manufactured in Little Rock, Arkansas, under quality control programs with The CertainTeed Flintlastic membrane roof covering inspections by ICC-ES. systems described in this report comply with, or are 6.0 EVIDENCE SUBMITTED suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following Data in accordance with the ICC-ES Acceptance Criteria conditions: for Membrane Roof-covering Systems (AC75), dated 5.1 Installation must comply with the applicable code, the July 2010 (editorially revised September 2016). manufacturer's published installation instructions and 7.0 IDENTIFICATION this report. If there are any conflicts between the 7.1 Each roll of CertainTeed Flintlastic roofing manufacturer's published installation instructions and membranes covered by this report is labeled with the this report,this report governs. CertainTeed LLC name and address, product name, 5.2 The roof covering systems must be installed only by date code, and the evaluation report number (ESR- authorized applicators approved by CertainTeed LLC. 1388). 5.3 Foam plastic insulation must be separated from the 7.2 The report holder's contact information is the interior of the building by an approved thermal barrier following: in accordance with IBC Section 2603.4.1.5 and IRC CERTAINTEED LLC Section R316.5.2, except when specifically 20 MOORES ROAD recognized in an ICC-ES evaluation report as outlined MALVERN, PENNSYLVANIA 19355 in Footnote 3 following Table 1D. (610)651-5847 5.4 For all above-deck insulations except foam plastics, www.certainteed.com the roof covering assembly, including such insulation, must have passed testing in accordance with UL 1256 or FM 4450. 5.5 Foam plastic insulation, where used, must bear the label of an approved agency indicating that the foam plastic has a flame-spread index of not more than 75 ESR-1388 1 Most Widely Accepted and Trusted Page 6 of 27 TABLE 1C—EXTERNAL ROOF FIRE CLASSIFICATIONS'7INSULATED COMBUSTIBLE DECKS'(Continued) SYSTEM MAX. VAPOR BARRIER INSULATION 2,3.8/ ROOF COVER NO. CLASS ROOF OR ANCHOR SHEETa THICKNESS a SLOPE Base Sheeta Ply Sheet Membrane Surfacing Flintlastic GTA, Flintlastic GTA CoolStar,Flintlastic (Optional) Type G2 or G2 GTS or Flintlastic Type G2 or G2 Perlite/min. Glasbase Base GTS CoolStar(HW) Karnak No.97 C-3 A /4:12 Glasbase Base Sheet 1.5-inch Sheet(MA)or None or Flintlastic GMS, Fi t 11/ted Aluminum a (LL)or(MA) (HM) Flintlastic GMS at 1 z gal/sq. CoolStar or Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar(HM) Polyisocyanurate, Type G2 or G2 Flintlastic FR Cap 30 perlite,glass fiber or Glasbase Base C-4 A /z:12 None wood fiber/any Sheet(MA)or None or Flintlastic FR Cap None thickness (HM) 30 CoolStar(HM) (Optional) One or more Type One or more G1,Type G2 or Flexiglas Base Flexiglas Base Flintlastic FR Cap 30 Sheet or Flintlastic Sheet or Flintlastic or Flintlastic FR Cap Perlite,glass fiber/any Base 20 adhered Base 20 or 30 CoolStar adhered C-5 A /2:12 None with Henry 553 Flintlastic Poly with Henry 553 MBA None thickness MBA Gold SMS Base Sheet Gold Modified Modified Bitumen adhered with Bitumen Adhesive at Adhesive at 11/2 Henry 553 MBA 11/2 gal/sq. gal/sq. Gold Modified Bitumen Adhesive at 11/2 gal/sq. DensDeck/min. Flintlastic SA Flintlastic SA Cap-FR C-6 A 1/2:12 None '/a-inch NailBase(MA) None or Flintlastic SA Cap- None FR CoolStar(SA) Polyisocyanurate, perlite,glass fiber or Flintlastic SA Flintlastic SA Mid Flintlastic SA Cap C-7 C 2:12 None wood fiber/any NailBase(MA) PIy( ) FR CoolStar SA or Flintlastic r(SA) -p- None (SA) thickness Polyisocyanurate, Flintlastic SA perlite,glass fiber or NailBase(MA)or wood fiber/any Flintlastic SA Flintlastic SA Flintlastic SA Cap FR, C-8 A /2:12 None A PlyBase(SA to Flintlastic SA Cap-FR None thickness primed DensDeck PlyBase(S ) CoolStar(SA) DensDeck/min. or DensDeck /a inch DuraGuard only) Perlite,glass fiber or Flintlastic SA Flintlastic SA Cap FR C-9 C Unlimited None wood fiber/any NailBase(MA) None or Flintlastic SA Cap- None thickness FR CoolStar(SA) Polyisocyanurate, (Optional) perlite,glass fiber or Flintlastic SA Flintlastic SA Mid Flintlastic SA Cap FR C-10 C 2:12 None wood fiber/any NailBase(MA) Flintlastic SA orFR CoolStar Flintlastic (SA) A))p- None thickness PlyBase(SA) Flintboard ISO/min. 1.5 inch Flintlastic FR Cap 30 C-11 A 1'/z:12 None (presecured) Flintlastic Base 20 None T or Flintlastic FR None DensDeck/min. T(HW) Cap 30 T CoolStar '/a-inch (HW) adhered in hot asphalt For SI:1 inch=25.4 mm,1 gal/sq.=0.41 I/mz.