Loading...
HomeMy WebLinkAboutDesign Pressures(1) Florida Window & Door Co. 1 125 N.Dixie Hwy Tel.(561)848-4900 LakeWorth, FL 33460 Floridawindowanddoor.com Property Information Building Information Owner: Agnieszka Loaza Wind Zone: 160 MPH. Address: 125 NE Bracken Rd Exposure Category: C Port Saint Lucie,FL 34983 Minimum Building Dimension: 35 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 End 37 51 7 32.9 -43.7 2 End 37 51 7 32.9 -43.7 3 End 53 26 7 33.5 -44.8 4 End 106 38 7 31.2 -40.4 L-5 End 111 63 7 30.0 -38.0 Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code. Page 1 of 1