Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED Construction Drawings
<<w=175; h=175; n=BLANK - SIG; a=11>>SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.G-001SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:TITLE SHEET0FOR CONSTRUCTIONAM07/01/210LOCATION MAPVICINITY MAPKnow what's below. Call before you dig.RCOMPLIANCE CODEPROJECT SUMMARYPROJECT DESCRIPTIONUTILITY COMPANIESSHEET INDEXSHEETNO:DESCRIPTION:REV:DATE:BY:G-001TITLE SHEET007/01/21AMG-002GENERAL NOTES007/01/21AMC-101DETAILED SITE PLAN007/01/21AMC-102DETAILED GROUND PLAN007/01/21AMC-201TOWER ELEVATION007/01/21AMC-401ANTENNA INFORMATION & SCHEDULE007/01/21AMC-501CONSTRUCTION DETAILS007/01/21AME-501GROUNDING DETAILS007/01/21AMR-601SUPPLEMENTALR-602SUPPLEMENTALR-603SUPPLEMENTALR-604SUPPLEMENTALR-605SUPPLEMENTALR-606SUPPLEMENTALR-607SUPPLEMENTALR-604 (5)SUPPLEMENTALPOWER COMPANY: FLORIDA POWER & LIGHTPHONE: (800) 226-3545TELEPHONE COMPANY: CENTURY LINKPHONE: (800) 366-8201ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLEDIN ACCORDANCE WITH THE CURRENT EDITIONS OF THEFOLLOWING CODES AS ADOPTED BY THE LOCALGOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS ISTO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TOTHESE CODES.1.2020 FLORIDA BUILDING CODE, 7TH EDITION2.ANSI/TIA-222-H3.6TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA 70)4.2017 NATIONAL ELECTRICAL CODE5.BASIC WIND SPEED: 153 MPH (3-SECOND GUST)6.CITY/COUNTY ORDINANCESSITE LOCATIONT-MOBILE EXCALIBUR ANTENNA AMENDMENT PLANCONFIGURATIONSITE ADDRESS:5690 ENVIRONMENT DR.FORT PIERCE, FL 34981COUNTY: ST. LUCIEGEOGRAPHIC COORDINATES:LATITUDE: 27.37959167LONGITUDE: -80.3821GROUND ELEVATION: 21' AMSLENVIRONMENT DRTHE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASEDAND TOWER MOUNTED EQUIPMENT AS INDICATED PER BELOW:TOWER WORK:REMOVE (3) MOUNT(s), (9) ANTENNA(s), (6) RRH(s), (3) TTA(s), (3)COVP(s), (12) 1-5/8" COAX CABLE(s) AND (3) 1.24" HYBRID CABLE(s)INSTALL (3) MOUNT(s), (6) ANTENNA(s), (6) RRH(s) AND (3) 1.99"HYBRID CABLE(s)GROUND WORK:REMOVE (2) CABINET(s), (1) COVP(s), (3) RRH(s) AND (6) DIPLEXER(s)INSTALL (1) ENCLOSURE 6160 CABINET AND (1) B160 BATTERYEXISTING (1) PPC(s), (1) METER/DISCONNECT, (1) GPS(s), (1)TELCO(s), (1) CIENA(s), (1) ATS(s) AND (1) GENERATOR(s) TO REMAIN1.THE FACILITY IS UNMANNED.2.A TECHNICIAN WILL VISIT THE SITE APPROXIMATELY ONCE AMONTH FOR ROUTINE INSPECTION AND MAINTENANCE.3.THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LANDDISTURBANCE OR EFFECT OF STORM WATER DRAINAGE.4.NO SANITARY SEWER, POTABLE WATER OR TRASH DISPOSALIS REQUIRED.5.HANDICAP ACCESS IS NOT REQUIRED.6.THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS ANELIGIBLE FACILITIES REQUEST ENTITLED TO EXPEDITEDREVIEW UNDER 47 U.S.C. § 1455(A) AS A MODIFICATION OF ANEXISTING WIRELESS TOWER THAT INVOLVES THECOLLOCATION, REMOVAL, AND/OR REPLACEMENT OFTRANSMISSION EQUIPMENT THAT IS NOT A SUBSTANTIALCHANGE UNDER CFR § 1.61000 (B)(7).PROJECT NOTESPROJECT LOCATION DIRECTIONSFROM I-95 AT EXIT #126 TRAVEL EAST ON CR-712 (W MIDWAYRD) FOR 2.0 MILES. THEN TURN LEFT (NORTH) ONTO S JENKINSRD AND TRAVEL 0.3 TENTHS OF A MILE. NOW TURN RIGHT(NORTH) ONTO MAGNUM DR AND TRAVEL 0.1 TENTH OF A MILEAND ARRIVE AT ACCESS ROAD GATE.ATC SITE NAME: MIDWAY ROADATC SITE NUMBER: 5100T-MOBILE SITE NAME: A2P0047AT-MOBILE SITE NUMBER: A2P0047ASITE ADDRESS:5690 ENVIRONMENT DR.FORT PIERCE, FL 34981PROJECT TEAMAPPLICANT:T-MOBILE5901 BENJAMIN CENTERDRIVE, SUITE 110 A-BTAMPA, FL 33634TOWER OWNER:AMERICAN TOWER10 PRESIDENTIAL WAYWOBURN, MA 01801ENGINEER:ATC TOWER SERVICES, LLC3500 REGENCY PKWY STE 100CARY, NC 27518PROPERTY OWNER:US FILTER RECOVERY SERVICES (MID-ATLANTIC) INC5690 ENVIRONMENT DR.FORT PIERCE, FL 34981MAGNUM DR S JENKINS RD <<w=175; h=175; n=BLANK - SIG; a=11>>SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.G-002SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:GENERAL NOTES0FOR CONSTRUCTIONAM07/01/210GENERAL CONSTRUCTION NOTES:1.OWNER FURNISHED MATERIALS, T-MOBILE "THE COMPANY" WILL PROVIDE AND THECONTRACTOR WILL INSTALLA.BTS EQUIPMENT FRAME (PLATFORM) AND ICEBRIDGE SHELTER (GROUNDBUILD/CO-LOCATE ONLY)B.AC/TELCO INTERFACE BOX (PPC)C.ICE BRIDGE (CABLE TRAY WITH COVER) (GROUND BUILD/CO-LOCATE ONLY, GCTO FURNISH AND INSTALL FOR ROOFTOP INSTALLATION)D.TOWERS, MONOPOLESE.TOWER LIGHTINGF.GENERATORS & LIQUID PROPANE TANKG.ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTINGH.ANTENNAS (INSTALLED BY OTHERS)I.TRANSMISSION LINEJ.TRANSMISSION LINE JUMPERSK.TRANSMISSION LINE CONNECTORS WITH WEATHERPROOFING KITSL.TRANSMISSION LINE GROUND KITSM.HANGERSN.HOISTING GRIPSO.BTS EQUIPMENT2.THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THECOMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCHMATERIALS AS FENCING, STRUCTURAL STEEL SUPPORTING SUB-FRAME FOR PLATFORM,ROOFING LABOR AND MATERIALS, GROUNDING RINGS, GROUNDING WIRES,COPPER-CLAD OR XIT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS ANDDISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARY ELECTRICAL POWER,CONDUIT, LANDSCAPING COMPOUND STONE, CRANES, CORE DRILLING, SLEEPERS ANDRUBBER MATTING, REBAR, CONCRETE CAISSONS, PADS AND/OR AUGER MOUNTS,MISCELLANEOUS FASTENERS, CABLE TRAYS, NON-STANDARD ANTENNA FRAMES ANDALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TOTHE DRAWINGS AND SPECIFICATIONS. IT IS THE POSITION OF T-MOBILE TO APPLY FORPERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIREDPERMITS.3.ALL WORK SHALL CONFORM TO ALL CURRENT APPLICABLE FEDERAL, STATE, AND LOCALCODES, INCLUDING ANSI/EIA/TIA-222, AND COMPLY WITH ATC CONSTRUCTIONSPECIFICATIONS.4.CONTRACTOR SHALL CONTACT LOCAL 811 FOR IDENTIFICATION OF UNDERGROUNDUTILITIES PRIOR TO START OF CONSTRUCTION.5.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIREDINSPECTIONS.6.ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, ANDSITE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONTRACTOR WITH ALLDISCREPANCIES REPORTED TO THE ENGINEER.7.DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS.8.DETAILS SHOWN ARE TYPICAL; SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESSOTHERWISE NOTED.9.THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTIONSAFETY WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.10.CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDEDFOR STABILITY ARE INSTALLED. THESE ELEMENTS ARE AS FOLLOWS: LATERAL BRACING,ANCHOR BOLTS, ETC.11.CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDSDRAINS, DRAIN PIPES, VENTS, ETC. BEFORE COMMENCING WORK.12.INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING ORNONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE T-MOBILEREP PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH REMEDIAL ACTION SHALLREQUIRE WRITTEN APPROVAL BY THE T-MOBILE REP PRIOR TO PROCEEDING.13.EACH CONTRACTOR SHALL COOPERATE WITH THE T-MOBILE REP, AND COORDINATE HISWORK WITH THE WORK OF OTHERS.14.CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THISPROJECT TO MATCH EXISTING PRE-CONSTRUCTION CONDITIONS TO THE SATISFACTIONOF THE T-MOBILE CONSTRUCTION MANAGER.15.ALL CABLE/CONDUIT ENTRY/EXIT PORTS SHALL BE WEATHERPROOFED DURINGINSTALLATION USING A SILICONE SEALANT.16.WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET,CONTRACTOR SHALL NOTIFY THE T-MOBILE REP AND ENGINEER OF RECORDIMMEDIATELY.17.CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETEAND CURRENT SET OF DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT.18.CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OFEACH DAY.19.CONTRACTOR SHALL COORDINATE WORK SCHEDULE WITH AMERICAN TOWERCORPORATION (ATC) AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OFOTHER OCCUPANTS OF THE FACILITY.20.CONTRACTOR SHALL FURNISH T-MOBILE AND AMERICAN TOWER CORPORATION (ATC)WITH A PDF MARKED UP AS-BUILT SET OF DRAWINGS UPON COMPLETION OF WORK.21.PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REPTO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED. ALL ITEMS NOT PROVIDEDSHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR WILL INSTALLALL ITEMS PROVIDED.22.PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REPTO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR. ALL REQUIREDPERMITS NOT OBTAINED BY T-MOBILE MUST BE OBTAINED, AND PAID FOR, BY THECONTRACTOR.23.CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH T-MOBILESPECIFICATIONS AND REQUIREMENTS.24.CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO T-MOBILE FOR REVIEW ANDAPPROVAL PRIOR TO FABRICATION.25.ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'SSPECIFICATIONS AND LOCATED ACCORDING TO T-MOBILE SPECIFICATIONS, AND ASSHOWN IN THESE PLANS.26.THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTIONMEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FORCOORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT.27.CONTRACTOR SHALL NOTIFY T-MOBILE REP A MINIMUM OF 48 HOURS IN ADVANCE OFPOURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS ORSEALING ANY WALL, FLOOR OR ROOF PENETRATIONS FOR ENGINEERING REVIEW ANDAPPROVAL.28.CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY INCLUDING COMPLIANCE WITHALL APPLICABLE OSHA STANDARDS AND RECOMMENDATIONS AND SHALL PROVIDE ALLNECESSARY SAFETY DEVICES INCLUDING PPE AND PPM AND CONSTRUCTION DEVICESSUCH AS WELDING AND FIRE PREVENTION, TEMPORARY SHORING, SCAFFOLDING,TRENCH BOXES/SLOPING, BARRIERS, ETC.29.THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES ANDSUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD. ANYDAMAGE CAUSED BY NEGLECT ON THE PART OF THIS CONTRACTOR OR HISREPRESENTATIVES, OR BY THE ELEMENTS DUE TO NEGLECT ON THE PART OF THISCONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK, OR TO HISWORK OR THE WORK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HISEXPENSE TO THE OWNER'S SATISFACTION.30.ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNERBY MECHANICS SKILLED IN THE TRADE INVOLVED. THE QUALITY OF WORKMANSHIPSHALL BE SUBJECT TO THE APPROVAL OF THE T-MOBILE REP. ANY WORK FOUND BYTHE T-MOBILE REP TO BE OF INFERIOR QUALITY AND/OR WORKMANSHIP SHALL BEREPLACED AND/OR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL ISOBTAINED.31.IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OFMATERIALS LISTED HEREINAFTER BY MANUFACTURER’S NAMES AND/ORMANUFACTURER’S CATALOG NUMBER SHALL BE PROVIDED BY THESE MANUFACTURERSAS SPECIFIED.32.T-MOBILE FURNISHED EQUIPMENT SHALL BE PICKED-UP AT THE T-MOBILE WAREHOUSE,NO LATER THAN 48HR AFTER BEING NOTIFIED INSURED, STORED, UNCRATE, PROTECTEDAND INSTALLED BY THE CONTRACTOR WITH ALL APPURTENANCES REQUIRED TO PLACETHE EQUIPMENT IN OPERATION, READY FOR USE. THE CONTRACTOR SHALL BERESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP.33.T-MOBILE OR HIS ARCHITECT/ENGINEER RESERVES THE RIGHT TO REJECT ANYEQUIPMENT OR MATERIALS WHICH, IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITHTHE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THEEQUIPMENT SHALL BE REPLACED WITH EQUIPMENT CONFORMING TO THEREQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TOT-MOBILE OR THEIR ARCHITECT/ENGINEER.SPECIAL CONSTRUCTIONANTENNA INSTALLATION NOTES:1.WORK INCLUDED:A.ANTENNA AND COAXIAL CABLES ARE FURNISHED BY T-MOBILE UNDER ASEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNAINSTALLATION CONTRACTOR IN TERMS OD COORDINATION AND SITE ACCESS.ERECTION SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OFPERSONNEL ANDB.INSTALL ANTENNA AS INDICATE ON DRAWINGS AND T-MOBILE SPECIFICATIONS.C.INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGSD.INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE.E.CONTRACTOR SHALL PROVIDE FOUR (4) SETS OF SWEEP TESTS USINGANRITZU-PACKARD 8713B RF SCALAR NETWORK ANALYZER. SUBMIT FREQUENCYDOMAIN REFLECTOMETER(FDR) TESTS RESULTS TO THE PROJECT MANAGER.SWEEP TESTS SHALL BE AS PER ATTACHED RFS "MINIMUM FIELD TESTINGRECOMMENDED FOR ANTENNA AND HELIAX COAXIAL CABLE SYSTEMS" DATED10/5/93. TESTING SHALL BE PERFORMED BY AN INDEPENDENT TESTING SERVICEAND BE BOUND AND SUBMITTED WITHIN ONE WEEK OF WORK COMPLETION.F.INSTALL COAXIAL CABLES AND TERMINATING BETWEEN ANTENNAS ANDEQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALLCONNECTIONS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURER'SREQUIREMENTS. TERMINATE ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OFENTRY PORT LOCATION UNLESS OTHERWISE STATED.G.ANTENNA AND COAXIAL CABLE GROUNDING:2.ALL EXTERIOR #6 GREED GROUND WIRE "DAISY CHAIN" CONNECTIONS ARE TO BEWEATHER SEALED WITH RFS CONNECTORS/SPLICE WEATHERPROOFING KIT #221213 OREQUAL.3.ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OFCOAXIAL CABLE (NOT WITHIN BENDS)ALL DISCREPANCIES FROM WHAT IS SHOWN ON THESECONSTRUCTION DRAWINGS SHALL BE COMMUNICATED TO ATCENGINEERING IMMEDIATELY FOR CORRECTION OR RE-DESIGN. FAILURE TO COMMUNICATE DIRECTLY WITH ATC ENGINEERING ORANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIORAPPROVAL FROM ATC ENGINEERING SHALL BE THE SOLERESPONSIBILITY OF THE GENERAL CONTRACTOR. <<w=175; h=175; n=BLANK - SIG; a=11>>XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X XXXXX0D2908-SM4X15STUD 0D2908-SM4X15STUD M6X200C8112A-S XXSHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-101SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:DETAILED SITE PLAN0FOR CONSTRUCTIONAM07/01/210(MODIFIED AS REQUIRED FOR UPGRADE)1C-102SITE PLAN NOTES:1.THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITEPRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT.2.ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALLPROPOSED AND EXISTING EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN. BEFORE UTILIZING EXISTING CABLE SUPPORTS, COAX PORTS, INSTALLING NEWPORTS OR ANY OTHER EQUIPMENT, CONTRACTOR SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS.3.NO ELECTRICAL SCOPE IS INCLUDED IN THIS PROJECT. LEGENDAUTOMATIC TRANSFER SWITCHATSDISCONNECTDELECTRICALEFIBERFBOLLARDBGENERATOR RECEPTACALGHAND HOLE, VAULTHH, VICE BRIDGEIBKENTROX BOXKGENERATORGENMETERMLIGHTING CONTROLLCPULL BOXPBPOWER POLEPPTELCOTTRANSFORMERTRNXCHAINLINK FENCEGROUNDING TEST WELLCELL SITE CABINETCSCPROPOSED CABLE LENGTH:1.ESTIMATED LENGTH OF PROPOSED CABLE IS 230'.ESTIMATED LENGTH OF CABLE WAS PROVIDED BYCUSTOMER OR CALCULATED BY ADDING THE RADCENTER AND THE DISTANCE FROM THE SHELTERENTRY PLATE TO THE TOWER (ALONG THE ICEBRIDGE) AND A SAFETY FACTOR MEASUREMENT OF15% (OF THE TWO PREVIOUS VALUES), CDS DEFERTO GREATEST CABLE LENGTH.2.ROUTE PROPOSED CABLES ALONG SAME PATH ASEXISTING CABLES AND IN ACCORDANCE WITHSTRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZEEXISTING CABLE SUPPORT STRUCTURES ASPROVIDED FOR CARRIER TO ADEQUATELY SECURECABLES, USING EITHER APPROPRIATELY SIZEDSTAINLESS STEEL SNAP-INS OR MOUNTINGHARDWARE AND BRACKETS AS SPECIFIED BY CABLEMANUFACTURER. OTHERWISE, ATTACH CABLES TOHORIZONTAL OR DIAGONAL TOWER MEMBERSUSING PROPOSED STAINLESS STEEL ADAPTERS (DONOT ATTACH TO TOWER LEG).PROPOSED (3) 1.99" HYBRID CABLES(ROUTED PER PROPOSED CABLE LENGTH NOTE 2)(REFER TO PROPOSED CABLE LENGTH NOTE ONTHIS PAGE)(12) 1-5/8" COAX CABLES AND(3) 1.24" HYBRID CABLES(TO BE REMOVED)1DETAILED SITE PLANGRAPHIC SCALE( IN FEET )1 UNIT = 10 FEET105010GROUND WORK:1.TECH LIGHTS WILL BE REPOSITIONED IF NECESSARY,PROVIDE LIGHTING INSIDE THE CABINETS.2.EXISTING BTS CABINETS TO BE REMOVED. UTIILTY FEEDSINCLUDING PPC SHALL REMAIN AND RECONNECT.PROPOSEDENCLOSURE 6160CABINET1R-602PROPOSED B160BATTERY CABINET1R-6035'-0"6"6" <<w=175; h=175; n=BLANK - SIG; a=11>>SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-102SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:0FOR CONSTRUCTIONAM07/01/210DETAILED GROUNDPLAN1EXISTING GROUND EQUIPMENTGROUND WORK:1.TECH LIGHTS WILL BE REPOSITIONED IF NECESSARY,PROVIDE LIGHTING INSIDE THE CABINETS.2.EXISTING BTS CABINETS TO BE REMOVED. UTIILTY FEEDSINCLUDING PPC SHALL REMAIN AND RECONNECT.(TO BE REMOVED)(TO BE REMOVED)(TO BE REMOVED)(TO BE REMOVED)(NOT IN PHOTO)(TO BE REMOVED) <<w=175; h=175; n=BLANK - SIG; a=11>>SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-201SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:TOWER ELEVATION0FOR CONSTRUCTIONAM07/01/210TOWER NOTE:1.IT IS THE CONTRACTOR'S RESPONSIBILITY TOCONFIRM WITH THE PROJECT MANAGER THATTHEY HAVE THE MOST RECENT VERSION OF THESTRUCTURAL ANALYSIS BEFORE COMMENCINGWORK. EXISTING AND PROPOSED TOWERAPPURTENANCES, MOUNTS, AND ANTENNAS ARESHOWN BASED ON THE STRUCTURAL ANALYSIS.2.WHERE APPLICABLE, ALL NEW ANTENNAS,EQUIPMENT, MOUNTS, CABLING, ETC. SHALL BEPAINTED/SOCKED TO MATCH EXISTING EQUIPMENTIN ACCORDANCE WITH FAA, JURISDICTION, AND/OROTHER LOCAL REQUIREMENTS.3.ROUTE PROPOSED CABLES ALONG SAME PATH ASEXISTING CABLES AND IN ACCORDANCE WITHSTRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZEEXISTING CABLE SUPPORT STRUCTURES ASPROVIDED FOR CARRIER TO ADEQUATELY SECURECABLES, USING EITHER APPROPRIATELY SIZEDSTAINLESS STEEL SNAP-INS OR MOUNTINGHARDWARE AND BRACKETS AS SPECIFIED BYCABLE MANUFACTURER. OTHERWISE, ATTACHCABLES TO HORIZONTAL OR DIAGONAL TOWERMEMBERS USING PROPOSED STAINLESS STEELADAPTERS (DO NOT ATTACH TO TOWER LEG).4.TOWER ELEVATIONS ARE MEASURED FROM TOPOF BASE PLATE TO MATCH STRUCTURALANALYSIS. ELEVATIONS DO NOT REFLECT TRUEABOVE GROUND LEVEL (A.G.L.)1TOWER ELEVATIONSCALE: N.T.S.EXISTING T-MOBILERAD CENTER @180'PROPOSED T-MOBILEEQUIPMENT2C-401 <<w=175; h=175; n=BLANK - SIG; a=11>>SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-401SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:ANTENNA INFORMATION& SCHEDULE0FOR CONSTRUCTIONAM07/01/2101C-5013ANTENNA AND RF EQUIPMENT SCHEDULE2FINAL ANTENNA PLANSCALE: N.T.S.FINAL FIBER DISTRIBUTION / OVP BOXFINAL CABLING SUMMARYMODEL NUMBERSTATUSCOAXHYBRIDSTATUS---(3) 1.99"ADD-----CABLE LENGTHS FOR JUMPERSJUNCTION BOX TO RRU: 15'RRU TO ANTENNA: 10'1.CONFIRM WITH T-MOBILE REPFOR APPLICABLEUPDATES/REVISIONS ANDMOST RECENT RFDS FOR NSNCONFIGURATION (CONFIG). GCTO CAP ALL UNUSED PORTS.2.CONFIRM SPACING OFPROPOSED EQUIP DOES NOTCAUSE TOWER CONFLICTSNOR IMPEDE TOWER CLIMBINGPEGS.NOTESSTATUS ABBREVIATIONSRMV: TO BE REMOVED: TO REMAINREL: TO BE RELOCATEDADD: TO BE ADDED1EXISTING ANTENNA EQUIPMENTSCALE: N.T.S.ALL EXISTING ANTENNA, RADIOS, LINES, ETC.SHALL BE REMOVED. EXISTING MOUNT SHALL BEREPLACED.AZ.=ALPHA60°AZ.=ALPHA60° AZ.= BETA 180° AZ.= BETA 180°AZ.=GAMMA300°AZ.=GAMMA300°A1A2A3A4B1B2B3B4C1C2C3C4PROPOSED FFVV-65C-R3 ANTENNA(1 PER SECTOR)(TYP.3)PROPOSED AIR6449 ANTENNA(1 PER SECTOR)(TYP.3)PROPOSED RADIO 4460 B25,B66(1 PER SECTOR)(TYP.3)PROPOSED RADIO 4480 B71, B85A(1 PER SECTOR)(TYP.3)PROPOSED SITEPRO1 VFA10-HD-80SECTOR MOUNT(1 PER SECTOR) (TYP. 3)1C-5012C-5013C-5013C-501(TO BE REMOVED)(2 PER SECTOR) (TYP. 3)(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)(TO BE REMOVED)(1 PER SECTOR) (TYP. 3) <<w=175; h=175; n=BLANK - SIG; a=11>>SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-501SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:CONSTRUCTIONDETAILS0FOR CONSTRUCTIONAM07/01/210PROPOSED SECTOR FRAMEPROPOSED RRU MOUNT LOCATION (OPTION 2)(MOUNT PER MANUFACTURER'S SPECS)(ENSURE THAT BRACKET DOES NOT CONFLICT WITHEXISTING OR PROPOSED EQUIPMENT)PROPOSED RRU MOUNT LOCATION (OPTION 1)(MOUNT PER MANUFACTURER'S SPECS)(ENSURE THAT BRACKET DOES NOT CONFLICT WITHEXISTING OR PROPOSED EQUIPMENT)PROPOSED RRU MOUNT LOCATION (OPTION 3)(MOUNT PER MANUFACTURER'S SPECS)(ENSURE THAT BRACKET DOES NOT CONFLICT WITHEXISTING OR PROPOSED EQUIPMENT)3PROPOSED RRU MOUNTING DETAIL - TYPICALSCALE: N.T.S.PROPOSED SECTOR FRAMEPROPOSED ANTENNAPROPOSED 2-3/8" O.D. X 96" LONG SCH. 40ANTENNA MOUNTING PIPE2PROPOSED 5G ANTENNA MOUNTING DETAIL - TYPICALSCALE: N.T.S.5PROPOSED BREAKOUT CYLINDER ATTACHMENTSCALE: N.T.S.PROPOSEDHCS TRUNKPROPOSEDBREAKOUTCYLINDERPROPOSEDFIBER/DCPAIRSPROPOSED STAINLESSBANDING AS REQUIRED4CABINET ATTACHMENT DETAILSCALE: NOT TO SCALEPROPOSEDCABINETPROPOSED 1/2" HILTI KWIK BOLT3-5/8" NOMINAL EMBEDMENT NOTE:INSTALL HILTI KWIK BOLT ANCHORS STRICTLY PERINSTALLATION INSTRUCTIONS INCLUDED WITH PRODUCT ORFOUND ONLINE AT WWW.US.HILTI.COM. PROPERINSTALLATION IS CRITICAL FOR FULL PERFORMANCE.PROPOSED ANTENNAPROPOSED SECTOR MOUNT(SITE PRO 1 PART #: VFA10-HD-80)(INSTALL PER MANUFACTURER'S SPECS)(1 PER SECTOR) (TYP. 3)PROPOSED STIFF-ARM PROVIDED WITHMOUNT (TYP. 3)PROPOSED 2-3/8"Ø X 96" LONG SCH. 40ANTENNA MOUNITNG PIPE1PROPOSED ANTENNA MOUNTING DETAIL (ELEVATION)SCALE: NOT TO SCALE <<w=175; h=175; n=BLANK - SIG; a=11>>SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.E-501SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:GROUNDING DETAILS0FOR CONSTRUCTIONAM07/01/210DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECTGROUND WIRE DOWN TO GROUND BAR.CONTRACTOR SHALL PROVIDE WEATHERPROOFING KIT (ANDREW PARTNUMBER 221213) AND INSTALL/TAPE PER MANUFACTURER'S SPECIFICATIONS.2CABLE GROUND KIT CONNECTION DETAILSCALE: N.T.S.TO ANTENNATO EQUIPMENTTO GROUND BARANTENNA CABLE 2 1/2"Ø MAXGROUNDING KIT PER CABLEMANUFACTURER'S RECOMMENDATIONS(ANDREW OR APPROVED EQUAL)#6 AWG STRANDED COPPER GROUNDWIRE (GROUNDED TO GROUND BAR)GROUND KIT NOTES:1.2.1/4" X 4" X 6" GROUND BAR(ERICO P/N: EGBA14406CC OR EQUAL)3TOWER GROUND BAR DETAILSCALE: N.T.S.GROUND BAR NOTES:1.GROUND BAR KITS COME WITH ALL HARDWARE, NUTS, BOLTS,WASHERS, ETC. EXCEPT THE STRUCTURAL MOUNTING MEMBER(S).2.GROUND BAR TO BE BONDED DIRECTLY TO TOWER.3/8" SS LOCK WASHER(EACH SIDE)TWO-HOLE LUG, TO BE USEDWITH #2 AWG BCW(LOWER TOWER GROUNDBAR ONLY)3/8" X 1-1/2" SS BOLT(EACH SIDE)OCPD SIZEWIRE SIZEGROUND SIZECONDUIT SIZE80A/2P2#3 AWG#8 AWG1-1/4"100/2P2#2 AWG#8 AWG1-1/4"125A/2P2#1 AWG#8 AWG1-1/2"150A/2P2#1/0 AWG#8 AWG1-1/2"ELECTRICAL NOTES:1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATEWITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITYCOMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS,BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENTREQUIRED FOR ELECTRICAL SERVICE. ALL ELECTRICAL WORKSHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OFTHE STATE AND NATIONAL CODES, ORDINANCES ANDREGULATIONS APPLICABLE TO THIS PROJECT.2.ATC HAS NOT VERIFIED ANY EXISTING T-MOBILE GROUNDEQUIPMENT OR ELECTRICAL LOADING. PROPOSED WORK BASEDON INSTALLATION CONFIGURATION PROVIDED BY T-MOBILE.CONTRACTOR TO VERIFY EXISTING T-MOBILE PANEL HASSUFFICIENT SPACE FOR PROPOSED BREAKER. PROPOSED CABLEAND CONDUIT SHALL BE MINIMUM SIZE PER BELOW IN CHART.3.FOR SPECIFIC CABINET / ANCILLARY EQUIPMENT WIRINGREQUIREMENTS, THE T-MOBILE CONTRACTOR SHOULDREFERENCE DESIGN DOCUMENTS PROVIDED BY T-MOBILE FORTHIS CURRENT PROJECT CONFIGURATION, IN ACCORDANCE WITHLOCAL JURISDICTION REQUIREMENTS & NEC STANDARDS &PRACTICES.TO EQUIPMENTGROUND KIT NOTES:1.2.NOTES:1.THIS DETAIL IS INTENDED TO SHOW THE GENERAL GROUNDING REQUIREMENTS. SLIGHTADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS. THECONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORM THECONSTRUCTION MANAGER OF ANY CONFLICTS.2.SITE GROUNDING SHALL COMPLY WITH T-MOBILE GROUNDING STANDARDS, LATESTEDITION, AND COMPLY WITH T-MOBILE GROUNDING CHECKLIST, LATEST VERSION. WHENNATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN.PROPOSED CONNECTOR ANDWEATHERPROOFING KIT1TYPICAL ANTENNA GROUNDING DIAGRAMSCALE: N.T.S.PROPOSED ANTENNAPROPOSED JUMPERPROPOSED COAXGROUND KITSPROPOSEDANTENNASPROPOSED WEATHERPROOFING KIT2E-5013E-501GROUND BAR MOUNTEDNEAR/BELOW ANTENNA(TO BE INSTALLED IFREQUIRED)#6 AWG STRANDED CUWIRE WITH GREEN, 600V,THWN INSULATIONANTENNA CABLE TOCABINET (TYP.)PROPOSED CABLEGROUND KITPROPOSED #6 AWGSTRANDED CUWIRE WITH GREEN, 600V,THWN INSULATION TO PROPOSED RRUGROUND LUG (TYP.)2E-5014CABINET GROUNDING DETAILSCALE: N.T.S.PROPOSED CABINET#2 AWG STRANDED GREENINSULATED COPPER CONDUCTOR SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-601SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:SUPPLEMENTAL0FOR CONSTRUCTIONAM07/01/210NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT.1ANTENNA SPECIFICATIONSFOR ILLUSTRATIVE PURPOSES ONLY - N.T.S.2RRU SPECIFICATIONSFOR ILLUSTRATIVE PURPOSES ONLY - N.T.S.A BC A C BFRONT VIEWTOP VIEWFRONT VIEWTOP VIEWANTENNA SPECIFICATIONSANTENNA MODELABCWEIGHT(LBS)FFVV-65C-R3-V195.9"25.2"9.3"124.6AIR6449 B4133.1"20.6"8.6"104.0RRU SPECIFICATIONSRRU MODELABCWEIGHT(LBS)446019.6"15.7"12.1"109.0448021.8"15.7"7.5"84.0 SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-602SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:SUPPLEMENTAL0FOR CONSTRUCTIONAM07/01/210NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-603SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:SUPPLEMENTAL0FOR CONSTRUCTIONAM07/01/210NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-604SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:SUPPLEMENTAL0FOR CONSTRUCTIONAM07/01/210NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT.1MOUNT DETAILS SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-605SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:SUPPLEMENTAL0FOR CONSTRUCTIONAM07/01/2101MOUNT DETAILSNOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-606SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:SUPPLEMENTAL0FOR CONSTRUCTIONAM07/01/2101MOUNT DETAILSNOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-607SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:SUPPLEMENTAL0FOR CONSTRUCTIONAM07/01/2101MOUNT DETAILSNOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-604(5)SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 9053THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:07/01/21ATC JOB NO:A2P0047ACUSTOMER ID:13677274_G3A2P0047ACUSTOMER #:T Mobile©5100ATC SITE NAME:MIDWAY ROADA2P0047A5690 ENVIRONMENT DR.FORT PIERCE, FL 34981ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:SUPPLEMENTAL0FOR CONSTRUCTIONAM07/01/2101MOUNT DETAILSNOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT.