HomeMy WebLinkAboutPLOT PLAN & VECENITY MAP291'-3"126'-1"291'-3"126'-1"76'-6"32'-5"163'-0"26'-1"123PLOT PLAN WITH ROOF PLANHOUSE PHOTOVICINITY MAPSCALE: 1/32" = 1'-0"A-00SCALE: NTSA-00A-00SCALE: NTSPROJECT SITESHEET INDEXA-00 PLOT PLAN & VICINITY MAPS-01ROOF PLAN & MODULESS-02ATTACHMENT DETAILSE-01ELECTRICAL SITE PLANE-02ELECTRICAL LINE DIAGRAME-03WIRING CALCULATIONSE-04SYSTEM LABELINGE-05OPTIMIZER CHARTDS-01MODULE DATA SHEETDS-02 OPTIMIZER DATA SHEETDS-03INVERTER DATA SHEETDS-04RAIL DATA SHEETDS-05ATTACHMENT DATA SHEETDS-06GROUNDING DATA SHEETPROJECT DESCRIPTION:EQUIPMENT SUMMARY31 JINKO JKM370M-6RL3-B (370) MODULES1 SOLAREDGE SE11400H-US INVERTER31 SOLAREDGE POWER OPTIMIZER P40031 x 370 JINKO JKM370M-6RL3-B (370) MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESSHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMEA-00Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMPLOT PLAN & VICINITY MAPSYSTEM SIZE: 11.470 kW DC STCARRAY AREA # 1: 308.1 SQ FT.ARRAY AREA # 2: 328.64 SQ FT.PROJECT SITEGOVERNING CODES :FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)FLORIDA BUILDING CODE, 7TH EDITION 2020 EDITION (FBC)FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)2017 NATIONAL ELECTRICAL CODEFLORIDA FIRE PREVENTION CODE, 7TH EDITION (FFPC)ROOF #2(16) JINKO JKM370M-6RL3-B(370) MODULES(E) FENCE1-STORY HOUSE(E) DRIVEWAYSILVER OAK DR(E) POOLROOF #1(15) JINKO JKM370M-6RL3-B(370) MODULESASCE 7-16 WIND DESIGN CRITERIAULTIMATE WIND SPEED: 160 MPHNOMINAL WIND SPEED: 124 MPHWIND EXPOSURE: BRISK CATEGORY: II
SHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMES-01Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COM1ROOF PLAN & MODULESS-01SCALE: 1/8" = 1'-0"ROOF PLAN &MODULESMODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 31 MODULESMODULE TYPE = JINKO JKM370M-6RL3-B (370) MODULESWEIGHT = 47.40 LBS / 21.5 KG.MODULE DIMENSIONS = 73.03" x 40.51" = 20.54 SFUNIT WEIGHT OF ARRAY = 2.31 PSFJINKOJKM370M-6RL3-B (370)MODULES73.03"40.51"ARRAY & ROOF AREACALC'S (ROOF #1)DESCRIPTION (ROOF #1)ROOF TYPE - ASPHALT SHINGLESROOF TILT - 14°ROOF AZIMUTH - 270 °RAFTERS SIZE - 2"X4" @ 24" O.C.ARRAY AREA = 308.1 SQ. FT.ROOF FACE AREA = 1092 SQ. FT.308.1 / 1092 = 28.21% OF ROOFFACE AREA COVERED BY ARRAY(N) 62-FLASHFOOT 2 PVROOF ATTACHMENT(N) IRONRIDGEXR-10 RAIL (TYP.)SYP RAFTERS @ 24" O.C.36" WALKWAY PATH PER R324.6.1TYPROOF #2(16) JINKO JKM370M-6RL3-B(370) MODULESROOF #1(15) JINKO JKM370M-6RL3-B(370) MODULES4'-0"4'-0"18" FIRE SETBACK18" FIRE SETBACK36" FIRE SETBACK36" FIRE SETBACKROOF #1TILT - 14°AZIM. - 270°ROOF #2TILT - 14°AZIM. - 90°ARRAY & ROOF AREACALC'S (ROOF #2)DESCRIPTION (ROOF #2)ROOF TYPE - ASPHALT SHINGLESROOF TILT - 14°ROOF AZIMUTH - 90 °RAFTERS SIZE - 2"X4" @ 24" O.C.ARRAY AREA = 328.64 SQ. FT.ROOF FACE AREA = 983.95 SQ. FT.328.64 / 983.95 = 33.40% OF ROOFFACE AREA COVERED BY ARRAY1. APPLICABLE CODE: 2020 FLORIDA RESIDENTIAL CODE (7TH EDITION) &ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES.2. ATTACHMENT STRENGTH OF IRONRIDGE FLASHFOOT 2 ATTACHMENTSARE BASED OFF IRONRIDGE'S PULL TEST DATA AND IRONRIDGEMANUFACTURERS SPECIFICATIONS AND IT IS ASSUMED THE EXISTINGWOOD TRUSSES ARE SOUTHERN YELLOW PINE.3. SPACING OF THE IRONRIDGE FLASHFOOT 2 ATTACHMENTS SHALL BE ASFOLLOWS:*WIND ZONE 1 = 4'-0" ON CENTER, 1'-7" CANTILEVER*WIND ZONE 2e, 2r = 4'-0" ON CENTER, 1'-7" CANTILEVER*WIND ZONE 3 = 4'-0" ON CENTER, 1'-7" CANTILEVER4. IRONRIDGE FLASHFOOT 2 ATTACHMENT SHALL BE INSTALLED PERMANUFACTURER'S INSTRUCTIONS AND CONTRACTOR SHALL FOLLOWMANUFACTURER'S RECOMMENDATIONS TO WEATHER PROOF AND SEAL ALLROOF PENETRATIONS.6. DESIGN PARAMETERS SHOWN ARE BASED ON ALLOWABLE STRESSDESIGN (ASD) NOMINAL WIND SPEED PRESSURES PER SECTION 29.4.4 FORROOFTOP SOLAR PANELS PARALLEL TO THE ROOF SURFACE WITHEXPOSURE "B", RISK CATEGORY II, ENCLOSED BUILDING AND h < 60'-0"PER ASCE 7-16 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHERSTRUCTURES" AND 2020 F.B.C. (7TH EDITION). EXPOSED ANDNON-EXPOSED MODULES ARE LABELED AS SHOWN.5. EXISTING ROOF IS A TYPICAL GABLE ROOF FROM 7 DEGREES TO 20DEGREES WITH A ROOF COVERING OF ASPHALT SHINGLES. MEAN ROOFHEIGHT = 15 FT OR LESS ABOVE GRADE.7. ROOF SURFACE TO UNDERSIDE OF PANEL HEIGHT IS APPROXIMATELY 5INCHES AND INCREASED UPLIFT ON THE PORTION OF MODULES WITHIN A 10INCH CLEARANCE OF THE ROOF EDGES HAS BEEN CONSIDERED.8. "a" DIMENSION AS DEFINED PER ASCE 7-16 SHALL BE 4 FT REGARDLESSPER THE 2020 FLORIDA RESIDENTIAL CODE (7TH EDITION).10. SOLAR PANELS AND MOUNTING SYSTEM SHALL BE INSTALLED PERMANUFACTURER'S RECOMMENDATIONS.GENERAL STRUCTURAL NOTES:I CERTIFY THAT THEINSTALLATION OF THEMODULES IS IN COMPLIANCEWITH FBC: RESIDENTIALCHAPTER 3. THE ADDITIONOF THE SOLAR MODULESAND ALL ACCESSORIES TOTHE EXISTING BUILDING WILLNOT ADVERSELY AFFECTTHE STRUCTURAL INTEGRITYOF THE BUILDING AND CANSAFELY ACCOMODATE THENEW IMPOSED LOADS OFTHE SOLAR SYSTEM.LEGEND- ROOF OBSTRUCTION- PV ROOF ATTACHMENT- RAFTERS- NON-EXPOSED MODULE- EXPOSED MODULEEN- EDGE MODULEEDWIND ZONE 2e TYPWIND ZONE 1 TYPWIND ZONE 2r TYPWIND ZONE 3e TYPWIND ZONE 2n TYPWIND ZONE 3r TYPTOTAL ROOF AREAARRAY AREA = 630 SQ. FT.TOTAL PLAN VIEW ROOF AREAAREA = 2550 SQ. FT.630 / 2550 = 14.1% OF ROOF18" SETBACK IS OK PER R324.6.218" RIDGE SETBACK PER R324.6.2TYPEEEEEEEEEEEENNNNNNNNNNNNNNNNNNN
SHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMES-02Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMATTACHMENTDETAILSSHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMES-02Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMPV MODULE5/16x4.75" SS LAG BOLT W/MIN. 2.5" THREAD EMBEDMENT,SEALED PENETRATIONIRONRIDGE BONDED UFO FASTENER(END/MID CLAMP)(N) IRONRIDGE XR10 RAIL(N) IRONRIDGEFLASHFOOT22"X4" RAFTER @ 24"O.CSEE (2/S-02) FORENLARGED VIEWFLASHINGASSEMBLYCAP ASSEMBLYW/ 3/8" SS BOLT & NUTATTACHMENT DETAIL (enlarged view)S-02SCALE: NTSATTACHMENT DETAIL (enlarged view)S-02SCALE: NTS1ATTACHMENT DETAILS-02SCALE: 1" = 1'-0"1ATTACHMENT DETAILS-02ASPHALT SHINGLESASPHALT SHINGLE ROOF2NOTE: 2X4 RAFTES ASSUMED TO BE NO. 2 SYPAND SHALL BE VERIFIED IN THE FIELD.2"X4"
RAFTERS @
24"O
.C
JBJBUM MSP ACD INV1ELECTRICAL PLANE-01SCALE: 1/8" = 1'-0"ROOF PLAN &MODULESSHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMEE-01Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMSOLAR ARRAY 11.470 kW-DC STC(31) JINKO JKM370M-6RL3-B (370) MODULES(01) STRING OF 15 MODULES(01) STRING OF 16 MODULES(N) JUNCTION BOX (TYP.)(E) MAIN DISTRIBUTION PANEL(N) PV MAIN DISCONNECT(E) UTILITY METER(N) SOLAREDGESE11400H-US INVERTERCONDUITLEGEND- JUNCTION BOXJBMSP- MAIN DISTRIBUTION PANEL- ROOF OBSTRUCTION- CONDUIT- UTILITY METERUM(N) 31-SOLAREDGE POWEROPTIMIZERS P400STRING-2 (16 MODULES)STRING-1 (15 MODULES)(E) FRONT YARDSILVER OAK DR(E) BACK YARD
SHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMEE-02Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMELECTRICALLINE DIAGRAM1ELECTRICAL LINE DIAGRAME-02SCALE: NTS(N) JUNCTION BOX600 V, NEMA 3UL LISTEDSOLAREDGEOPTIMIZER P400 (TYP.)(3) #6 AWG THWN-2(1) #10 AWG THWN-2 - EGCIN 3/4" CONDUITPV MODULE(TYP.)INVERTERSOLAREDGE 11400H-US (240V)OUTPUT: 240 VAC, 47.5A99% CEC WEIGHTED EFFICIENCYNEMA 3R, UL LISTED, INTERNAL GFDIWITH INTEGRATED DC DISCONNECTL2L1L2L1GL2L1L2L1L1L2NL1L2NL1L2NN(E) MAIN DISTRIBUTIONPANEL, 150A RATED,240V.L2L1NGL2L1NG(N) PV MAINDISCONNECT:240V, 60A W/ 60A OCPD,LOCKABLE, NEMA 3RSTRING-1 (15 MODULES)STRING-2 (16 MODULES)=DCACNOTE: BARE COPPER-GND TO BEPROTECTED PER NEC 250.120(C)L2L1L2L1NOTE: IF CIRCUIT FROM JUNCTION BOXTO INVERTER IS WITHIN THE BUILDINGENCLOSURE, CONDUIT MUST BEMETALLIC PER NEC 690.31(E).(4) #10 AWG THWN-2(1) #10 AWG THWN-2 EGCIN 3/4" CONDUIT(4) #10 AWG, PV WIRE(1) #10 AWG BARE COPPER-GNDUTILITY GRID120/240V 150ASERVICEBOND #6 AWG CU TO EXISTINGGROUNDING ELECTRODE150A/2POCPDGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGSOLAR ARRAY 11.470 kW-DC STC(31) JINKO JKM370M-6RL3-B (370) MODULES(01) STRING OF 15 MODULES(01) STRING OF 16 MODULES(E) GROUNDINGELECTRODESYSTEM(3) #6 AWG THWN-2IN 3/4" CONDUIT
SHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMEE-03Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMWIRINGCALCULATIONSDC CONDUCTOR AMPACITY CALCULATIONS:ARRAY TO JUNCTION BOX :SOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #JINKO JKM370M-6RL3-B (370) MODULESVMP36.71VIMP10.08AVOC44.02VISC10.90AMODULE DIMENSION73.03"L x 40.51"W x 1.37"D (In Inch)AMBIENT TEMPERATURE SPECSRECORD LOW TEMP0°AMBIENT TEMP (HIGH TEMP 2%)33°CONDUIT HEIGHT0.5"ROOF TOP TEMP55°CONDUCTOR TEMPERATURE RATE90°MODULE TEMPERATURE COEFFICIENT OF Voc0.28%/°CEXPECTED WIRE TEMP (In Celsius)33°TEMP. CORRECTION PER TABLE (310.15)(B)(2)(a)0.96NO. OF CURRENT CARRYING CONDUCTORS4CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a)0.80CIRCUIT CONDUCTOR SIZE10 AWGCIRCUIT CONDUCTOR AMPACITY40AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B)18.75A1.25 X MAX DC OUTPUT CURRENTDERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC (310.15)(B)(2)(a)30.72ATEMP. CORRECTION PER TABLE (310.15)(B)(2)(a) XCONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) X CIRCUITCONDUCTOR AMPACITYResult should be greater than (18.75A) otherwise less the entry for circuit conductor size andampacityDC CONDUCTOR AMPACITY CALCULATIONS:FROM JUNCTION BOX TO INVERTER:AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUITPER NEC 310.15(B)(2)(c)+22°EXPECTED WIRE TEMP (In Celsius)33°+22° = 55°TEMP. CORRECTION PER TABLE (310.15)(B)(2)(a)0.76NO. OF CURRENT CARRYING CONDUCTORS4CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a)0.80CIRCUIT CONDUCTOR SIZE10AWGCIRCUIT CONDUCTOR AMPACITY40AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B)18.75A1.25 X MAX DC OUTPUT CURRENTDERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC (310.15)(B)(2)(a)24.32ATEMP. CORRECTION PER TABLE (310.15)(B)(2)(a) XCONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) X CIRCUITCONDUCTOR AMPACITYResult should be greater than (18.75A) otherwise less the entry for circuit conductor size andampacityELECTRICAL NOTESINVERTER SPECIFICATIONSMANUFACTURER / MODEL #SOLAREDGE SE11400H-USNOMINAL AC POWER11.4 kWNOMINAL OUTPUT VOLTAGE240 VACNOMINAL OUTPUT CURRENT47.5AAC CONDUCTOR AMPACITY CALCULATIONS:FROM INVERTER TO MSP :No. OF INVERTER1EXPECTED WIRE TEMP (In Celsius)33°TEMP. CORRECTION PER TABLE (310.15)(B)(2)(a)0.96NO. OF CURRENT CARRYING CONDUCTORS3CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a)1CIRCUIT CONDUCTOR SIZE6AWGCIRCUIT CONDUCTOR AMPACITY75AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B)59.38A1.25 X MAX INVERTER OUTPUT CURRENTDERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC (310.15)(B)(2)(a)72.00TEMP. CORRECTION PER TABLE (310.15)(B)(2)(a) XCONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) X CIRCUITCONDUCTOR AMPACITYResult should be greater than (59.38A) otherwise less the entry for circuit conductor size andampacity1.) ALL EQUIPMENT SHALL BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90°C WET ENVIRONMENT.3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED ASCLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEM. CONTRACTOR SHALL FURNISH ALL NECESSARYOUTLETS, SUPPORTS, FITTINGS , AND ACCESSORIES TO MEET APPLICABLE CODES AND STANDARDS.6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZETHEM ACCORDINGLY.7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND ACCESSIBLE.8.) INSTALL MODULE AND RACKING GROUNDING HARDWARE PER MANUFACTURER'S INSTRUCTION.
SHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMEE-04Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMSYSTEMLABELINGLABEL LOCATION:DC DISCONNECT ON INVERTER ANDROOF JUNCTION BOX PER NEC 690.35(F)WARNING:PHOTOVOLTAICPOWER SOURCELABEL LOCATION:CONDUIT, COMBINER BOX(PER CODE: NEC 690.31(G)(3)(4)THE DC CONDUCTORS OF THEPHOTOVOLTAIC SYSTEM AREUNDERGROUND AND MAY BE ENERGIZEDWARNINGELECTRIC SHOCK HAZARD!LABEL LOCATION:AC DISCONNECT & INVERTER(PER CODE: NEC690.54)PHOTOVOLTAIC SYSTEM AC DISCONNECTMAXIMUM AC OPERATING CURRENT 47.5 AMPSMAXIMUM AC OPERATING VOLTAGE 240 VOLTSRAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMLABEL LOCATION:RAPID SHUTDOWN(PER CODE: NEC 690.56(C)(3)WARNING!DO NOT RELOCATE THISOVERCURRENT DEVICEPOWER SOURCE OUTPUT CONNECTIONLABEL LOCATION:ADJACENT TO PV BREAKER (IF APPLICABLE).PER CODE(S): NEC 2017: 705.12(B)(2)(3)(b)SOLAR PV SYSTEMEQUIPPED WITH RAPIDSHUTDOWNSOLARELECTRIC PVPANELSTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWNPV SYSTEM AND REDUCESHOCK HAZARD IN THEARRAY.LABEL LOCATION:ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTINGMEANS TO WHICH THE PV SYSTEMS ARE CONNECTED.PER CODE(S): NEC 2017: 690.56(C)(1)(a)INVERTERPHOTOVOLTAIC DC DISCONNECTMAXIMUM SYSTEM VOLTAGE:MAXIMUM CIRCUIT CURRENT:MAX RATED OUTPUT CURRENT OF THE CHARGECONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED):VDCADCADCLABEL LOCATION:INVERTER(S), DC DISCONNECT(S).PER CODE(S): NEC 2017: 690.5328.7480
SHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMEE-05Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMOPTIMIZERCHART
SHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMEDS-01Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMDATA SHEETMODULE
SHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMEDS-02Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMDATA SHEETOPTIMIZER
SHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMEDS-03Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMDATA SHEETINVERTER
SHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMEDS-04Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMDATA SHEETRAIL
SHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMEDS-05Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMDATA SHEETATTACHMENT
SHEET NAMESHEET SIZESHEET NUMBERJOYNER RESIDENCE
ANSI B11" X 17"PROJECT NAMEDS-06Signature with Seal5809 SILVER OAK DR
FORT PIERCE, FL 34982
REVDATEDESCRIPTIONREVISIONS0109-08-2021INITIALSOLAR ENERGY SPECIALISTS6418 HOFFNER AVE #100,ORLANDO, FL 32822engineering@yourenergyspecialistcorp.netJEFFREY A. TORRES, P.E.FL PE #80379SUNSMART ENGINEERING, LLCFL COA #35170925 SUNSHINE LANEALTAMONTE SPRINGS, FL 32714JEFF.TORRES@SUNSMARTENGINEERING.COMDATA SHEETGROUNDING