Loading...
HomeMy WebLinkAboutElevator PlanPALM BEACH LIFTS, INC. 1748 Australian Avenue North, Suite 14 Riviera Beach, Florida 33404 (561) 863-7707 Fax (561) 863-7799 August 17, 2011 Malasky Homes 1300 Fla Maqngo rd #15 West Palm Beach, FL 33409 Subject: 3415 S Indian River Dr. PERMIT # 1107-0007 George � SPECIFICATION Quantity: 1 ;Type: Whisperide 2 stage DP Capacity: 1,000lbs •Speed: 40 fpm Travel: 121811 ` Landings: 2 F I L Openings:. 2 Commit Relay. Logic Pit: 2' Power Supply: 720 V.A:C.", "30.amp, single h Overhead: 10 Lighting Syppiy: 110 V.A:C , 15 amp, single p- a. Operation:' Automatic Mach�rte Room Location; adj. Co Size: 4'5" W: x 4'9" d x Vh Power Doors: Optional. PUMP -Type Uitima 3210m e eutral Spec!ial Conditrons: " Base cab is cabinet grade,pl ood veneer, hic hat ceiling fxture, sfalnless fl uses, -vinyl wooc gate, f nish floor - others: PALM BEACH LIFTS, INC. SPECIFICATIONS These specifications are intended to cover the complete installation of the el vator in a first-class workmanlike manner and to include all work and material in accordance with the drawing as specified. PERMITS AND INSPECTIONS The elevator contractor shall obtain and pay for necessary Municipal or State inspections and permits, as required, and make tests as called for by the regulation of such authorities. The Contractor shall furnish and install the Hydraulic. Elevator(s) as manufa ured by PALM BEACH LIFTS, INC. All material furnished by the manufacturer shall be guaranteed or a, period of one year against defects in workmanship. POWER UNIT I j A Power Unit -especially designed and manufactured for this service shall befumished. It shall include a constant displacement rotary screw type pump, .motor oil reservoir, hydraul c control unit and oil level gauge. Controller shall be a relay logic control panel, standard with emerges y power loweringt, and. shall be contained in a metal cabinet. VALVE(S) The control valve.includes safety check•valve, UP direction valve and high pressure relief. UP leveling andsoftstop features available.when specified. Manual lowering of elevator at power unit is standard. Control valves shall .be solenoid operated 'and designed to open a d close gradually to give smooth control. All valves shall' be readily accessible for adjustment. AUTOMATIC -TWO-WAY LEVELING When applicable, an .automatic two-way leveling device shall be provided so: hat the car will approach landing stop at reduced speed from either -direction of travel. The leveling d. vice shall, .within its zone, be entirelyindependent`of the operating device and shall automatically stop and:maintain.the car. approximately level;+/-1 /2" within the landing, -regardless of the change :i i load. PLUNGER The Plunger shall :be accurately groan. d and polished seamless steel. The -b: "ttom of the..plunger shall be fitted with a heavy steel disc welddd in place and provided with a suitable xtended..edge :to Provide. a positroe stop d6sign6d_6.'preve6fihe plunger from leaving the. cylinder.. The top of _the plunger shall. be provided with an internal welded steel -disc. I CYLINDER The Cylinder shall: be machined :from. steel pipe with a machined flange at th upper end,and. a heavy steel bulkhead -welded in the lower end The:cylinder shall be providedwith: Ei suitable steel --fitting for . connecting to oil line and with an air bleeder. A pipe rupture valve is fined between oiLsupply line and cylinder for protection against oil line 'breakage. GUIDE RAILS Guide rails shall be provided for the car consisting of 8# T steel and framing by heavy steel brackets. to the hoistway PALM BEACH LIFTS, INC. SPECIFICATIONS (cont.) ELECTRIC WIRING Furnish and install complete necessary insulated wiring to connect all parts electric wiring shall comply with the requirements of the National Electric Q the equipment. All OPERATION Operation shall be fully automatic. A call station shall be furnished with a push button for each landing served. The car station shall have one button for each level served. All cab operating panels are equipped with an emergency stop switch, alarm button, automatic emergency lowering, emergency lighting and cab light switch. CAB `Standard cab dimensions shall be as specified and as allowed by clear hok -cab. shall be constructed of no less than 3/4" thick wood panels. The cab constructed of no less than I" thick wood,,panels. The cab will -be °set in a 1 7.4 9,ply.plywood is used for cab manufacturing. The use of MDF, particle bi substrates is not allowed in ourcab:construction. A- note,about.ourcabs. We build custom cabs. Every hoistway is carefully measured before and. :phase. A custom cab, unlike a "prefab," should fit like a glove. Items we 1.1 Maximizing the hoistway size and shape allowable. ■ Perfectly aligning the edges, strike side and/or hinge side.of the cab hoistway door jambs. • Maximizing the cab: height. A.taller cab yields .a feeling .of'spaciousn Assur'ing,that no equipment other than the cab can beseen.from the ■ The ability to build your cab around .obstacles that sometimes. exist-_d ■ Your cab is built in a appropriate time frame prior to installation at jot ■ Everycab -is assembied:.at our facility prior ;to being delivered. After hoistwaylhe cab is .again Jrispedt6d. for, perfection. ■ You, the customer, have the abilityi :get -::exactly: what you want. Ya ay dimensions. The and ceiling will be steel reinforcing frame. I or other inferior I our first installation on are no less than: relationship to .the de or inside of the cab. construction. mbly in your design is your choice. FIXTURES Fixtures. are of elevator type and are :appropriately labeled as to each button r switch function. Designer options and features are available. DOOR;LOCKS A -combination unit system contact and lock shall be furnished for each hois. �a%y.entrance A locking device:shall.prevent elevator operationunless:d_ oors are closed.a' d:prevent gpenmg of doors;when car is not at that landing. PIRE.RUPTURE VALVE A pipe rupture valve.prevents the,car from exceeding contract speed in the d wn direction in the event that the oil supply line has failed. PALM BEACH LIFTS, INC. (WORK BY OTHERS) 1. Permanent power to operate the elevator must be provided to a lockabl� fused disconnect. A machine room/area is to be provided by the ownerlagent before installation begins, per Palm Beach Lifts',. Inc. specifications. If temporary power is provided to expedite the installation, it is the owner/agent's responsibility to provide adequate power. Due to the: desirable battery backup feature that our controllers offer, it that the following disconnect, or its equal, be used: Siemans (or comparable quality) SMNS HF221 N D SMNS.HA161234 auxiliary contact kit SMNS HR21 rejection clip kit (RKS type fuse) Without an auxiliary contact in disconnect, as listed above, emergency be rerooved-properly when disconnect is turned off. highly recommended voltage cannot . 2-. Where applicable, tow sleeves, three inches -in diameter; are to be provided for the electrical, conduit. anOydraulic hose from the machine room to the hoistway. If tr nching is needed this alsa.shall be provided by the owner/agent. 3. . No.conduit wiring and piping other than pertaining to the lift equipment i permitted in the hoistway. 4. Due to close running, clearance, the owner/agent, must assure .that the hoistway is constructed .plumb, square and true to dimensions as specified Palm. Beach Lifts, InG. 'S: ' It -is the soleresponsibilityof the owner/agent to provide adequate supp rt for guide rail fastenings and a shaft :which will safely support all`loads. imposed by lift quipment. 6. The pit floor is to be provided by owner/agent to .support a :load, as specified by Palm: Beach. Lifts, Inc. 7 Pit must be clean, dry and level: Pit water pr9p. ing,:or sump, if.requi'' is to be:prov�ded:by -owned-igent: 8 .Any changes to overhead must: be -approved by Palm:Beach Lifts, Inc. p. for to ordering. .equipment. 9.._ Pit walis.must be in line with rail.and:hoistway:walls. Where applicable, io footing,or obstruction shall be..under the cut.out.area, designated for cylinder installation. 1:0 Where'applicable, front wall hoistway is to -be left at. the lowest level until the. car enclosure is. in talled Entrance. frames ar61.lo be erected after the elevator is installed. Finish grouting .and masonryaround doors is the responsibility of the ownerlagent. 1.1. Call buttons must be ;inserted in the wall. The drywall and painting .after.installation, is -the responsibility of thLowner/agent. 1;2_ Palm Beach Lifts, Inc. highly recommends the installation of .solid -core doors at each landing and will not bee responsible for doors warping and repairs caused by their wa ping. Door hardware is the responsibility of the owner/agent. PALM BEACH LIFTS11 , INC. J 1748 Australian Avenue North, Suite 14 Riviera Beach, Florida 33404 (561) 863-7707 Fax (561) 863-7799 August 17, 2011 To: Fax: Subject: 341 S Indian River Dr. George Pantuso, MACHINE ROOM POWER .REQUIREMENTS: rec6mrnend6 that 1 Siemans (or cote SMNS HF221 N SMNS HA116123 SMNS HR21= rejf Without;an-auxiliary. .cannot be removed:1 POWEWSUPPLY 3,0"ampaervice 220/24011V single -OK Ground and:neutTA. I. Separate 110 Vac lig TELEPHONE Telephone ff ' wirk if; phoneline is .not w Phone: )attery backup feature. that our controllers pfl a following'disconnect, .or its equal, be used`. arable quality) auxiliary contact kit .tion clip kit MKS` type fuse) intact in disconnect, as.listed above, emerg+ 'operly when disconnect is -,turned off. circuit for cab 'lighting (recomnmt.i dd) to a standard female; jack preferable red -into a standard female jack, ;wires rmust bE � d ;to :aid- it,is highly lowering voltage i. RESIDENTIAL SUBMERSIBLE UNIT NAME TANK DIMENSION (Inches) TOTAL VOLUME RE CAPACITY USEABLE TOTAL WEIGHT WIDE DEPTH HEIGHT (US gal) (SERV (US gal) (US gal) (LBS) " � N / � � %�/�, / !� fl.' —01 260 - 370 20 gal 24 13 26 28 8 20 HEIGHT. The total weight does not Include oil and optional equipment. —CONNECTION BOX VE jLes InaustlnCs'Toumebo Inc 3TE 3U6IENNE (Q �BEC) Page 8 Power Units 229,1=800-953-3229 '219' 3Om Property of I.T.I. Hydraulik TWO STAGE Dimensional Data for "S" Type Jacks SIZE ST-6385-S ST-70100-S ST-85120-S A mm (in), 50(1.97) 63(2.48) 7.0(275) 85(335) B1 nun (in) 7.5 (0.295) . 7.5 Q.295) 7.5 (0 95) 7-5(0295) . . . . . . . . . . . . . . . . . . H mm, (in), 102(4-01) .141 165(6.50) K*i, ........... Imm 140 (SS ) 140,LS.5) 140 L5 V.nlm (fin:) 5-7 (2.244) 63'(2.480) 63 OU NUMBER SoN Size M36 x 70mm or 3/4' NC x r ST-6385-S BOLT SUE M30 or 3/4' NC .15MM Oil Lift 63mm And Standard t STME PA lo 'Systems 85 mm Type S o w E - Tdlesdopic. Diameter Cyl inder Rams on #9 2nd STAGE 81 WALL THICKNESS JACKIS PRE -FILLED WITH 2Sinrn I WAY LUBE OIL OIL OWN F'117ING ., .- �.AR. �OLEEOEW. 6.S.. + M .0 OUM TUBE HI WAIL THICACNESS, rn - 0 1 1 /1" NPT fEMALE PIPE PLUG u 13mm'—f L Assistance flange,Opt�.ion and Assistance _..I 0 19rnm Guide. Shoes; See Pag#es 23 and # 215.' 11 ice between the stway door is 39. (2) 2 x 10 glued and screwed, supported and: 'lr fastened between. (2).2 x 4-behind plywood for supporting rail brackets. .All supports.should be strapped to slabs, joists, and trusses. The Typical stud and wall board construction: