Loading...
HomeMy WebLinkAboutEnergy Code,FORM 1100A-08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A r Project Name: The Pantuso Residence Street: 3415 S. Indian River Drive Builder Name: Permit Office: City, State, Zip: Fort Pierce , FL , Owner: Permit Number: Jurisdiction: FILE r y De3ign Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (4353.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 4363.30 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2899.0 sqft.) Insulation Area 6. Cbnditioned floor area (ft2) 4847 a. Cathedral/Single Assembly (Unvented) R=20.0 2899.00 ft2 b. N/A R= ft2 7. Windows(665.5 sqft.) Description Area c. N/A R= ft2 a. U-Factor: Sgl, default 665.50 ft2 SHGC: Tinted, default 11. Ducts b. U-Factor: N/A ft2 a. Sup: Interior Ret: Interior AH: Interior Sup. R= 6, 969.4 ft2 SHGC: 12. Cooling systems c. U-Factor: N/A ft2 a. Central Unit Cap: 108.0 kBtu/hr SHGC: SEER: 22 d. U-Factor: N/A ft2 13. Heating systems SHGC: a. Electric Strip Heat Cap: 73.6 kBtu/hr e. U-Factor: N/A ft2 COP:1 SHGC: 14. Hot water systems 8. Floor Types (2899.0 sqft.) Insulation Area a. Natural Gas Cap: 80 gallons a. Slab -On -Grade Edge Insulation R=0.0 2899.00 ft2 EF: 0.59 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits CF, CV, Pstat Total As -Built Modified Loads: 66.15 Glass/Floor Area: 0.137 PASS Total Baseline Loads: 87.43 1 hereby certify that the plans and specifications covered by Review of the plans and tIli8 Sx�Z, this calculation are in complianc with the Florida Energy specifications covered by this yaf Code. calculation indicates compliance with the Florida Energy Code. �.r,,r' f4 rrrrrCR PREPARED By, Before construction is completed - DATE: this building will be inspected for compliance with Section 553.908 ""._. •.j certify building, designed, is in Florida Statutes. I hereby that this as compliance with the Florida Energy Co I e. C0D WS OWNER/AG T: BUILDING OFFICIAL: U'ATE: 2 - DATE: i 3/3/2011 9:42 AM EnergyGauge® USA - FlaRes2008 Page 1 of 6 PROJECT Title: The Pantuso Residence Bedrooms: 4 Adress Type: Street Address Building Type: FLAsBuilt Conditioned Area: 4847 Lot # .Owner: Total Stories: 2 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 3415 S. Indian River Dri Permit Office: Cross Ventilation: Yes County: St. Lucie "Jurisdiction: Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 75 70 722 62 Low FLOORS # Floor Type Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 231 ft 0 2899 ft2 0 0 1 ROOF Roof Gable Roof Solar Deck # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Hip Metal 3140 ft2 0 ft2 Medium 0.96 No 20 22.6 deg ATTIC Area RBS IRCC V # Type Ventilation Vent Ratio (1 in) 1 Full attic Unvented 0 2899 ft2 N N CEILING # Ceiling Type R-Value Area Framing Frac Truss Type 1 Cathedral/Single Assembly (Unvented 20 2899 ft2 0.11 Wood WALLS Cavity Sheathing Framing Solar # Ornt Adjacent To Wall Type R-Value Area R-Value Fraction Absor. 1 N Exterior Concrete Block - Int Insul 4.1 550 ft2 0 0.75 2 S Exterior Concrete Block - Int Insul 4.1 550 ft2 0 0.75 - 3 E Exterior Concrete Block - Int Insul 4.1 586.6666 0 0.75 4 W Exterior Concrete Block - Int Insul 4.1 586.6666 0 0.75 5 N Exterior Concrete Block - Int Insul 4.1 453.3333 0 0.75 ' 6 S Exterior Concrete Block - Int Insul 4.1 453.3333 0 0.75 7 E Exterior Concrete Block - Int Insul 4.1 586.6666 0 0.75 a 8 W Exterior Concrete Block - Int Insul 4.1 586.6666 0 0.75 3/3/2011 9:42 AM EnergyGauge® USA - FlaRes2008 Page 2 of 6 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 • PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/3/2011 9:42 AM EnergyGauge® USA - FlaRes2008 / Page 5 of 6 FORM 1100A-08 Code Compliance Checklist Residential Whole Building Performance Method A - Details ,J ADDRESS: 3415 S. Indian River Drive PERMIT #: . Fort Pierce, FL, INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE �CHETL Exterior Windows & Doors N1106.AB.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls N1106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is - installed that extends from, and is sealed to, the foundation to the top plate. Floors N1106.AB.1.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings N1106.AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures N1106.AB.1.2 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. Multi -story Houses N1106.AB.1.2 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N1112.ABC.3 Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each system. Insulation N1104.AB.1 Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both N1102.B.1.1 sides. Common ceiling & floors R-11. 3/3/2011 9:42 AM EnergyGauge® USA - FlaRes2008 Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 76 The lower the EnergyPerformance Index, the more efficient the homes 3415 S. Indian River Drive, Fort Pierce, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftZ) 7. Windows— Description a. U-Factor: Sgl, default SHGC: Tinted, default b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: e. U-Factor: N/A SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=4.1 4353.30 ftZ b. N/A R= ftZ 1 c. N/A R= ftz 4 d. N/A R= ft2 No 10. Ceiling Types Insulation Area 4847 a. Cathedral/Single Assembly (Unvented) R=20.0 2899.00 ftz b. N/A R= ftZ Area c. N/A R= ftZ 665.50 ftZ 11. Ducts ftZ a. Sup: Interior Ret: Interior AH: Interior Sup. R= 6, 969.4 ftZ 12. Cooling systems ftZ a. Central Unit Cap: 108.0 kBtu/hr SEER: 22 ftZ 13. Heating systems a. Electric Strip Heat Cap: 73.6 kBtu/hr ftZ COP: 1 14. Hot water systems Insulation Area a. Natural Gas Cap: 80 gallons R=0.0 2899.00 ftZ EF: 0.59 R= ftZ b. Conservation features R= ftZ None 15. Credits CF, CV, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home mFjy qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (.321) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the ' Department of Community Affairs at (850) 487-1824. **Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G 'of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge® USA - FlaRes2008