HomeMy WebLinkAboutEnergy Code,FORM 1100A-08
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs Residential Performance Method A
r
Project Name: The Pantuso Residence
Street: 3415 S. Indian River Drive
Builder Name:
Permit Office:
City, State, Zip: Fort Pierce , FL ,
Owner:
Permit Number:
Jurisdiction:
FILE
r y
De3ign Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (4353.3 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 4363.30 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2899.0 sqft.)
Insulation Area
6. Cbnditioned floor area (ft2) 4847
a. Cathedral/Single Assembly (Unvented) R=20.0 2899.00 ft2
b. N/A
R= ft2
7. Windows(665.5 sqft.) Description Area
c. N/A
R= ft2
a. U-Factor: Sgl, default 665.50 ft2
SHGC: Tinted, default
11. Ducts
b. U-Factor: N/A ft2
a. Sup: Interior Ret: Interior AH: Interior Sup. R= 6, 969.4 ft2
SHGC:
12. Cooling systems
c. U-Factor: N/A ft2
a. Central Unit
Cap: 108.0 kBtu/hr
SHGC:
SEER: 22
d. U-Factor: N/A ft2
13. Heating systems
SHGC:
a. Electric Strip Heat
Cap: 73.6 kBtu/hr
e. U-Factor: N/A ft2
COP:1
SHGC:
14. Hot water systems
8. Floor Types (2899.0 sqft.) Insulation Area
a. Natural Gas
Cap: 80 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2899.00 ft2
EF: 0.59
b. N/A R= ft2
b. Conservation features
c. N/A R= ft2
None
15. Credits
CF, CV, Pstat
Total As -Built Modified Loads: 66.15
Glass/Floor Area: 0.137
PASS
Total Baseline Loads: 87.43
1 hereby certify that the plans and specifications covered by
Review of the plans and
tIli8 Sx�Z,
this calculation are in complianc with the Florida Energy
specifications covered by this
yaf
Code.
calculation indicates compliance
with the Florida Energy Code.
�.r,,r'
f4 rrrrrCR
PREPARED By,
Before construction is completed
-
DATE:
this building will be inspected for
compliance with Section 553.908
""._. •.j
certify building, designed, is in
Florida Statutes.
I hereby that this as compliance
with the Florida Energy Co I e.
C0D WS
OWNER/AG T:
BUILDING OFFICIAL:
U'ATE: 2 -
DATE:
i
3/3/2011 9:42 AM
EnergyGauge® USA - FlaRes2008
Page 1 of 6
PROJECT
Title:
The Pantuso Residence
Bedrooms: 4
Adress Type:
Street Address
Building Type:
FLAsBuilt
Conditioned Area: 4847
Lot #
.Owner:
Total Stories: 2
Block/SubDivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
3415 S. Indian River Dri
Permit Office:
Cross Ventilation: Yes
County:
St. Lucie
"Jurisdiction:
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
Design
Location
TMY Site Zone 97.5 %
2.5 %
Winter Summer Degree Days Moisture
Range
FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39
90
75 70 722
62
Low
FLOORS
#
Floor Type
Perimeter R-Value
Area
Tile Wood
Carpet
1
Slab -On -Grade Edge Insulatio 231 ft 0
2899 ft2
0 0
1
ROOF
Roof Gable
Roof
Solar Deck
#
Type Materials Area Area
Color
Absor. Tested Insul.
Pitch
1
Hip
Metal 3140 ft2 0 ft2 Medium
0.96 No 20
22.6 deg
ATTIC
Area
RBS IRCC
V #
Type
Ventilation Vent Ratio (1 in)
1
Full attic
Unvented 0
2899 ft2 N N
CEILING
#
Ceiling Type
R-Value
Area
Framing Frac
Truss Type
1
Cathedral/Single Assembly (Unvented 20
2899 ft2
0.11
Wood
WALLS
Cavity
Sheathing
Framing
Solar
#
Ornt Adjacent To
Wall Type
R-Value
Area R-Value
Fraction Absor.
1
N Exterior
Concrete Block - Int Insul
4.1
550 ft2
0
0.75
2
S Exterior
Concrete Block - Int Insul
4.1
550 ft2
0
0.75
- 3
E Exterior
Concrete Block - Int Insul
4.1
586.6666
0
0.75
4
W Exterior
Concrete Block - Int Insul
4.1
586.6666
0
0.75
5
N Exterior
Concrete Block - Int Insul
4.1
453.3333
0
0.75
' 6
S Exterior
Concrete Block - Int Insul
4.1
453.3333
0
0.75
7
E Exterior
Concrete Block - Int Insul
4.1
586.6666
0
0.75
a 8
W Exterior
Concrete Block - Int Insul
4.1
586.6666
0
0.75
3/3/2011 9:42 AM EnergyGauge® USA - FlaRes2008 Page 2 of 6
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
•
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
3/3/2011 9:42 AM EnergyGauge® USA - FlaRes2008 / Page 5 of 6
FORM 1100A-08
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
,J ADDRESS: 3415 S. Indian River Drive PERMIT #:
. Fort Pierce, FL,
INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
�CHETL
Exterior Windows & Doors
N1106.AB.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
N1106.AB.1.2
Caulk, gasket, weatherstrip or seal between: windows/doors &
frames, surrounding wall; foundation & wall sole or sill plate; joints
between exterior wall panels at corners; utility penetrations;
between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is
-
installed that extends from, and is sealed to, the foundation to the
top plate.
Floors
N1106.AB.1.2
Penetrations/openings > 1/8" sealed unless backed by truss or
joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier
is installed that is sealed to the perimeter, penetrations and seams.
Ceilings
N1106.AB.1.2
Between walls & ceilings; penetrations of ceiling plane to top floor;
around shafts, chases, soffits, chimneys, cabinets sealed to
continuous air barrier; gaps in gyp board & top plate; attic access.
EXCEPTION: Frame ceilings where a continuous infiltration barrier
is installed that is sealed at the perimeter, at penetrations and
seams.
Recessed Lighting Fixtures
N1106.AB.1.2
Type IC rated with no penetrations, sealed; or Type IC or non -IC
rated, installed inside a sealed box with 1/2" clearance & 3" from
insulation; or Type IC with < 2.0 cfm from conditioned space,
tested.
Multi -story Houses
N1106.AB.1.2
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
N1106.AB.1.3
Exhaust fans vented to outdoors, dampers; combustion space
heaters comply with NFPA, have combustion air.
OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
N1112.AB.3
Comply with efficiency requirements in Table N1112.ABC.3
Switch or clearly marked circuit breaker (electric) or cutoff (gas)
must be provided. External or built-in heat trap required.
Swimming Pools & Spas
N1112.AB.2.3
Spas & heated pools must have covers (except solar heated).
Non-commercial pools must have a pump timer. Gas spa & pool
heaters must have a minimum thermal efficiency of 78%.
Heat pump pool heaters shall have a minimum COP of 4.0.
Shower heads
N1112.AB.2.4
Water flow must be restricted to no more than 2.5 gallons per
minute at 80 PSIG.
Air Distribution Systems
N1110.AB
All ducts, fittings, mechanical equipment and plenum chambers
shall be mechanically attached, sealed, insulated and installed in
accordance with the criteria of Section N1110.AB.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
N1107.AB.2
Separate readily accessible manual or automatic thermostat for
each system.
Insulation
N1104.AB.1
Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both
N1102.B.1.1
sides. Common ceiling & floors R-11.
3/3/2011 9:42 AM EnergyGauge® USA - FlaRes2008 Page 6 of 6
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 76
The lower the EnergyPerformance Index, the more efficient the homes
3415 S. Indian River Drive, Fort Pierce, FL,
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftZ)
7. Windows— Description
a. U-Factor: Sgl, default
SHGC: Tinted, default
b. U-Factor: N/A
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
e. U-Factor: N/A
SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
New (From Plans)
9. Wall Types
Insulation Area
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 4353.30 ftZ
b. N/A
R= ftZ
1
c. N/A
R= ftz
4
d. N/A
R= ft2
No
10. Ceiling Types
Insulation Area
4847
a. Cathedral/Single Assembly (Unvented)
R=20.0 2899.00 ftz
b. N/A
R= ftZ
Area
c. N/A
R= ftZ
665.50 ftZ
11. Ducts
ftZ
a. Sup: Interior Ret: Interior AH: Interior
Sup. R= 6, 969.4 ftZ
12. Cooling systems
ftZ
a. Central Unit
Cap: 108.0 kBtu/hr
SEER: 22
ftZ
13. Heating systems
a. Electric Strip Heat
Cap: 73.6 kBtu/hr
ftZ
COP: 1
14. Hot water systems
Insulation Area a. Natural Gas Cap: 80 gallons
R=0.0 2899.00 ftZ EF: 0.59
R= ftZ b. Conservation features
R= ftZ None
15. Credits CF, CV, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
*Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA -
FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home
mFjy qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at
(.321) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified
Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the
' Department of Community Affairs at (850) 487-1824.
**Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G
'of the Florida Building Code, Residential, if not DEFAULT.
EnergyGauge® USA - FlaRes2008