HomeMy WebLinkAboutRevisions; Move Electrical Sub-PanelOFFICE USE ONLY: )ATE FILED: REVISION FEE: 9 ti PERMIT # /U-O 7 7 RECEIPT # n _ _ r-,c 1. LOCATION/SITE " ADDRESS: �, A15 Bl� t" K i 1/ w Y 1 J2 R�r-- P1 ew c¢. j f c. 21yea 2. DETAILED DESCRIPTION OF PROJECT XEnVISIONS: i v I oy 4L �P_te CA (k c.cj SJb - (xn 21 �o M 9P ragR L xj ( 1-6 i n. S,J Q. 3. 4. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: Cool BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): Jkl- OWNER/BUILDER INFORMATION: NAME: A' ADDRESS: CITY: PHONE: ARCHITECT/ENGINEER INFORMATION: NAME: E h J Aji S e e, n Al2 ADDRESS: ' ri i CITY: ' ST. STATE: FAX: STATE: FAX: CERT. #: -2 b61 cl q ZIP: ZIP: PHONE (DAYTIME): �v� /- st7��i"'70-7 FAX:(al SLCCC: 9/23/09 Revised OVIU2010 -, Uri LL W� ® o0 Wm W ® �� 0 IL W CC InL y c Job No. 09-105 Seal A Roger P. Janssen AR-14785 Drawing No. E - 2.2 Becrc d Legend & DUPLEX RECEPTACLE >� HALF SWITCHED DUPLEX RECEPT. QUADPLEX RECEPTACLE HALF SWITCHED QUADPLEX RECEPT. 220 RECEPTACLE -e- DEDICATED RECEPTACLE DUPLEX FLOOR OUTLET HALF SWITCHED FLOOR OUTLET QUAD FLOOR OUTLET t� U.C. DUPLEX RECEPTACLE CIRCULATING PUMP GAS sP SPEAKER IS VOLUME CONTROL STEREO: PROVIDE STEREO SPEAKER PRE -WIRE W/VOLUME CONTROLS TO THE STEREO LOCATION SELECTED BY OWNER. WALL SWITCH 5D SMOKE DETECTOR $3 3-WAY WALL SWITCH HEAT DETECTOR �:J Cq DETECTOR 4 4-WAY WALL SWITCH EXHAUST FAN DOOR SWITCH DS GARBAGE DISPOSAL GFI GROUND FAULT INTERRUPTER j 42 MOUNTING HEIGHT (INCHES) PUSH BUTTON [] BUZZER WP WEATHERPROOF �IiIM CHIME VP VAPOR PROOF rp ELECTRIC METER 4 TELEVISION JACK: RG6 ELECTRIC PANEL HOME RUN TO CWP N TELEPHONE JACK: CAT5 DISCONNECT SWITCH HONE RUN TO CWP [ b TELEPHONE / COMPUTER Oj JUNCTION BOX COMBINATION JACK ® FLOOR TELEPHONE JACK: CAT5 HOME RUN MOTOR TO CWP FLOOD LIGHT J O PROVIDE 3/4" CONDUIT W/PULL WIRE BACK TO FUTURE PANEL I.C. INTERCOM: TWO WAY CONNECTION TO ALL PHONE LINES NOTES: 1) ALL WHITE RECESSED INCANDESCENT LIGHTING 2) MOUNT ALL INTERIOR WALL SCONCES 75" H (VERIFY W/ OWNER) 3) PROVIDE DIMMABLE SWITCHES FOR ALL LIGHTING AND FANS. Q HALOGEN 'PUCK' LICHT ® RECESSED NCAIPESCENT .`{ SURFACE INCANDESCENT )C�DF DECORATIVE FIXTURE F(¢-- BRACKET INCANDESCENT ® WALL SCONCE 4 > RECESSED WALL WASHER F07 STEP LIGHT --�.; FLUORESCENT TUBE STRIP ® UNDER CABINET LIGHT I' X 4' SURFACE FLUORESCENT 2' X 4' SURFACE FLUORESCENT 4 STRUCTURED WIRING: (2) CAT2 & (2) R66 TO EACH LOCATION HOME RUN TO CWP CWp CENTRAL WIRING PANEL FOR STRUCTURED WIRING: (2) CAT5 & (2) R06 FROM EACH CON. LOCATION 70 A ELEC. PANELa 'D' 10,000 A.I.C. RATED 100% 1 KVA WIRE BKR POLE DESCRIPTION CIRC. CIRC. DESCRIPTION POLE BKR WIRE KVA 100% 0 1.5 12 20 1 GARAGE DOOR OPENER 1 2 GARAGE DOOR OPENER 1 20 12 1.5 0 0 1.5 12 20 1 INTERIOR LIGHTING 3 4 INTERIOR LIGHTING 1 20 12 1.5 0 0 1.5 12 20 1 EXTERIOR LIGHTING 5 6 EXTERIOR LIGHTING 1 20 12 1.5 0 0 1.5 12 20 1 GEN. RECEPTACLES 7 8 GEN. RECEPTACLES 1 20 12 1.5 0 0 1.5 12 20 1 ORCHID HOUSE LIGHTING 9 10 ORCHID HOUSE RECEPT. 1 20 12 1.5 0 0 0 0 0 1 SPACE 11 12 SPACE 1 0 0 0 1 0 0 0 0 0 1 SPACE 13 14 SPACE 1 0 0 0 0 0 0 0 0 1 SPACE 15 16 SPACE 1 0 0 0 0 0 7.5 SUBTOTAL SUBTOTAL 7.5 0 TOTAL LOAD (NO A/C) 1ST 10,000 AT 100% REMAINDER AT 40% A/C LOAD AT 65% TOTAL 15 10.00 2.0 0 12.0 X 1000 / 240 = 50 AMPS TOTAL THIS PANEL 150 A IELEC. PANEla W 10,000 A.D.C. RATED 100% KVA WIRE BKR POLE DESCRIPTION CIRC, CIRC. DESCRIPTION POLE BKR WIRE KVA 100% 0 1.5 12 20 1 O.H. DOOR 1 2 O.H. DOOR 1 20 12 1.5 0 0 2.0 10 30 2 SPA PUMP 3 4 POOL PUMP 2 30 10 2.0 0 1 5 6 1 0 1.5 12 20 1 GARAGE DOOR OPENER 7 8 GARAGE DOOR OPENER 1 20 12 1.5 0 0 .75 14 15 1 U.C. REFRIG. (LOGGIA) 9 10 BBQ HOOD (F. LOGGIA) 1 20 12 .75 0 0 .75 14 15 1 ICE MAKER (LOGGIA) 11 '12 CABANA EXHAUST FAN 1 20 20 1.5 0 0 1.5 12 20 1 EXT. GFI (GARAGE) 13 14 GFI (GARAGE) 1 20 12 1.5 0 0 1.5 12 20 1 GFI (GARAGE) 15 16 EXT. GFI 1 20 12 1.5 0 0 1.5 12 20 1 EXT. GFI (SUM. KITCHEN) 17 18 GARAGE LIGHTING 1 15 14 1.5 0 0 1.5 14 15 1 EXT. LIGHTING 19 20 EXT. LIGHTING 1 15 14 1.5 0 0 1.5 14 15 1 EXT. LIGHTING 21 22 EXT. LIGHTING 1 15 14 1.5 0 0 1.5 14 15 1 EXT. LIGHTING 23 24 LANDSCAPE LIGHTING 1 20 12 1.5 0 0 1.5 12 20 1 LANDSCAPE LIGHTING 25 26 LANDSCAPE LIGHTING 1 20 12 1.5 0 0 1.5 12 20 1 POOL LIGHTING 27 28 SPACE 1 0 0 0 0 0 0 0 0 1 SPACE 29 30 SPACE 1 0 0 0 1 0 0 18.5 SUBTOTAL SUBTOTAL 19.25 0 TOTAL LOAD (NO A/C) 37.75 1ST 10,000 AT 100% 10.00 REMAINDER AT 40% 11.1 A/C LOAD AT 65% 0 TOTAL 21.1 X 1000 / 240 = 87.9 AMPS TOTAL THIS PANEL 200 A ELEC. PANEL. U 10,000 A.I.C. RATED 100% KVA WIRE BKR POLE DESCRIPTION CIRC. CIRC. DESCRIPTION POLE BKR WIRE KVA 100% 10 0 6 60 2 AHU HEAT STRIP #1 1 2 AHU HEAT STRIP #2 2 60 6 0 10 1 3 4 1 0 0 8 40 2 COMPRESSOR #1 5 6 COMPRESSOR #2 2 40 8 0 0 1 7 8 0 1.5 12 20 1 WASHER 9 10 DRYER 2 30 10 5 0 0 3.5 10 30 2 WATER HEATER 11 12 1 1 13 14 RECIRCULATION PUMP 1 15 14 .75 0 0 10 6 60 2 DOUBLE OVEN 15 16 RANGE HOOD (KITCHEN) 1 20 12 1.5 0 1 17 18 REFRIG. (KITCHEN) 1 20 12 1.5 0 0 1.5 12 20 1 DISH WASHER (KITCHEN) 19 20 TRASH COMPACTOR 1 20 12 .75 0 0 1 1.5 1 12 20 1 1 GARBAGE DISP. 21 22 MICROWAVE 1 20 12 1.5 0 0 1.5 12 20 1 SMALL APPLIANCE 23 24 SMALL APPLIANCE 1 20 12 1.5 0 0 1.5 12 20 1 SMALL APPLIANCE 25 26 SMALL APPLIANCE 1 20 12 1.5 0 0 1.0 14 15 1 ELEVATOR EQUIP. 27 28 ELEVATOR PUMP 2 30 10 5.0 0 0 1.5 14 15 1 ALARM / DATA 29 1 0 1.5 12 20 1 EXT. GFI 31 __30 EXT. GFI 1 20 12 1.5 0 0 0 0 0 1 SPACE 33 _:32 34 SPACE 1 0 0 0 0 0 0 0 0 1 SPACE 35 36 SPACE 1 0 0 0 0 0 0 0 0 1 SPACE 37 38 SPACE 1 0 0 0 0 0 0 0 1 0 1 1 1 SPACE 39 40 SPACE 1 0 0 0 0 0 0 0 0 1 1 SPACE 41 42 SPACE 1 0 0 0 0 10 25.0 SUBTOTAL SUBTOTAL 20.5 10 TOTAL LOAD (NO A/C) 45.5 1ST 10,000 AT 100% 10.00 REMAINDER AT 40% 14.2 A/C LOAD AT 65% 13.0 TOTAL 37.2 X 1000 / 240 = 155 AMPS TOTAL THIS PANEL (2) 2 1 /2" C W/ (3) 300MCM THHN TO F.P.L. (4 600 AMP METER (2) 2 1 /2" C W/ (3) 300MCM THHN & (1) #1 CU GRND (2) 2 1 /2" C W/(3) 300MCM THHN ATS 600 AMP SVC RATED 3R GENERATOR 100 KW 600 AMP MOP MLO POOAI170A PANEL PANEL PANEL "A„ „B„ „C„ 150A 200A 200A IN IN IN AUNDRY GARAGE GARAGE 2" CONDUIT 2-3/0 1-1/0 i -As (1) #1/0 CU. GRND. WIRE TO COLD WATER PIPE AND 1-5/8" GDX 10' CU. SUPPLEMENTAL GROUND ROD AND TO ONE REINFORCING BAR IN THE FOUNDATION 20'-0" LONG. MIN. ELECTRICAL RISER N.T.S. 200 A ELEC. PANEL 'C' 10,000 A.D.C. RATED 100% KVA WIRE BKR POLE DESCRIPTION CIRC. CIRC. DESCRIPTION POLE BKR WIRE KVA 100% 0 0 8 40 2 COMPRESSOR #3 1 2 AHU HEAT STRIP #3 2 60 6 0 10 3 4 0 1.5 12 20 1 DEN BATH GFI 5 6 LAUNDRY GFI 1 20 12 1.5 0 0 1.5 12 20 1 GUEST BATH GFI 7 8 BATH #1 GFI 1 20 12 1.5 0 0 1.5 12 20 1 POWDER ROOM GFI 9 10 MASTER BATH GFI 1 20 12 1.5 0 0 1.5 14 15 1 GENERAL RECEPTACLES 11 12 GENERAL RECEPTACLES 1 15 14 1.5 0 0 1.5 14 15 1 GENERAL RECEPTACLES 13 14 GENERAL RECEPTACLES 1 15 14 1.5 0 0 1.5 14 15 1 GENERAL RECEPTACLES 15 16 GENERAL RECEPTACLES 1 15 14 1.5 0 0 1.5 14 15 1 GENERAL LIGHTING 17 18 GENERAL RECEPTACLES 1 15 14 1.5 0 0 1.5 14 15 1 GENERAL LIGHTING 19 20 GENERAL LIGHTING 1 15 14 1.5 0 0 1.5 14 15 1 GENERAL LIGHTING 21 22 GENERAL LIGHTING 1 15 14 1.5 0 0 1.5 14 15 1 GENERAL LIGHTING 23 24 GENERAL LIGHTING 1 15 14 1.5 0 0 1.5 14 15 1 GENERAL LIGHTING 25 26 GENERAL LIGHTING 1 15 14 1.5 0 0 1.5 14 15 1 GENERAL LIGHTING 27 28 GENERAL LIGHTING 1 15 14 1.5 0 0 1.5 14 15 1 GENERAL LIGHTING 29 30 GENERAL LIGHTING 1 15 14 1.5 0 0 1.5 14 15 1 GENERAL LIGHTING 31 32 GENERAL LIGHTING 1 15 14 1.5 0 0 1.5 14 15 1 GENERAL LIGHTING 33 34 GENERAL LIGHTING 1 15 14 1.5 0 0 0 0 0 1 SPACE 35 36 SPACE 1 0 0 0 0 0 0 0 0 1 SPACE 37 38 SPACE 1 0 0 0 0 0 0 0 0 1 SPACE 39 40 SPACE 1 0 0 0 0 0 0 0 0 1 SPACE 41 42 SPACE 1 0 0 0 0 22.5 SUBTOTAL SUBTOTAL 22.5 10 TOTAL LOAD (NO A/C) 45.0 1ST 10,000 AT 100% 10.00 REMAINDER AT 40% 14.0 A/C LOAD AT 65% 6.5 TOTAL 30.5 X 1000 / 240 = 127.1 AMPS TOTAL THIS PANEL NOTE: 1. ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS AND OTHER SIMILAR ROOMS SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER COMBINATION -TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT (N.E.C. 210.12 (B)• 2. TAMPER -RESISTANT RECEPTACLES (NEC 406.11) ARE REQUIRED IN ALL DWELLING UNITS IN ALL AREAS AS SPECIFIED IN 2008 NEC 210.52, ALL 125-VOLT, 15 AND 20 AMP RECEPTACLES. 3. SMOKE DETECTORS SHALL BE INSTALLED PER F.B.C. SEC. 905.2 AND THE BRANCH CIRCUIT CONTAINING SR,1OKE DETECTORS SHALL HAVE ARC -FAULT PROTECTION PER 2002 N.E.C. 210-12 �01 z TOTAL ELECTRICAL LOAD CALCULATIONS PANEL 'A' 37.75 KVA PANEL ' B' 45.5 KVA PANEL' C' 45. 0 PANEL' D' 15. 0 SUBTOTAL 143,25 KVA FIRST 10.0 KVA 1007 10.00 KVA THE REMAINDER @ 40% 53.3 KVA 3 SPACE HEATERS (30 KVA) @ 65% 19.5 KVA 3 AIR CONDITIONERS @ 100% 0 _ TOTAL DEMAND LOAD 82.8 KVA 82.8 KVA x 1000 / 240V = 345 AMPS TOTAL CALC, SERVICE SIZE 240 VOLT, 1 PHASE 600 AMPS 1. HEAT STRIP LOAD GOVERNS OVER CONDENSOR UNIT LOAD. 2. GENERAL LIGHTING CALCULATED @ 6,0:53 SQ/FT. X 3 (WATTS/SQ/FT.) = 18,159 WATTS / 18.2 KVA 18.2 KVA / 1.3 KVA = 14 (15) AMP CIRCUITS MIN. REQ. FOR GENERAL LIGHTING. 3. A/C CONTRACTOR SHALL SIZE A/C UNITS. A/C UNITS SHOWN ARE FOR ELECTRICAL_ CALCULATIONS ONLY. ELECTRICAL GENERAL. NOTES 1. SCOPE OF WORK: CONTRACTOR SHALL FURNISH AND INSTALL LIGHTING FIXTURES, ELECTRICAL DEVICES, APPLIANCES, EQUIPMENTS, AND CONDUIT/WIRES WHERE SHOWN AND AS SPECIFIED AND/OR AS PER OWNER/ARCHITECT. 2. CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, TOOLS, AND EQUIPMENTS TO INSTALL A COMPLETE AND OPERATING SYSTEM. 3. CONTRACTOR SHALL PROVIDE ALL REQUIRED PERMITS. 4. CONTRACTOR SHALL VERIFY REQUIREMENTS, EXACT LOCATIONS AND TYPE OF OUTLETS FOR ALL ELECTRICAL FIXTURES, PANEL APPLIANCES AND EQUIPMENTS. „D„ 5. CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONDUITS, POWER/CONTROL WIRES, DISCONNECT SWITCHES, AND OVER - CURRENT PROTECTIVE DEVICES FOR ALL MECHANICAL EQUIPMENT. ALL CONDUITS, WIRES, AND SWITCHES SHALL BE SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC). ALL FUSES SHALL BE SIZED AS REQUIRED BY 70A THE EQUIPMENT MANUFACTURER. 6. CONTRACTOR SHALL COORDINATE ALL SERVICE REQUIREMENTS WITH POWER COMPANY. IN RV 7. CONTRACTOR SHALL MEET WITH THE TELEPHONE COMPANY & COORDINATE THE LOCATION OF SERVICE POINT ON THE 3ARAGE PROPERTY LINE, THE INCOMING SERVICE CONDUIT, GROUNDING, ETC. AND WITH THE OWNER/ARCHITECT TO INSTALL TELEPHONE RACEWAYS TO TELEPHONE OUTLET POINTS THROUGHOUT THE PROJECT. ALL TELEPHONE WIRES SHALL BE INSTALLED IN CONDUITS. 8. CONTRACTOR SHALL PROVIDE OWNER WITH AS -BUILT DRAWINGS. 9. ALL MATERIALS SHALL BE NEW AND FREE FROM DEFECT, AND SHALL BE UNDERWRITER'S LABORATORIES (UL) APPROVED. 10. INSTALLATIONS SHALL COMPLY WITH THE NEC, STATE CODES, FLORIDA ENERGY EFF.CODE, LOCAL RULES, AND ORDINANCES. 2" CONDUIT 11. ELECTRICAL SYSTEM SHALL COMPLETELY & EFFECTIVELY BE GROUNDED AS REQUIRED BY THE LATEST NEC. 2-3/0 12. COORDINATE ALL LIGHT FIXTURE AND EQUIPMENT LOCATIONS WITH ARCHITECT AND MECHANICAL CONTRACTOR BEFORE 1 -1/0 INSTALLATIONS. 13. CONDUCTORS SHALL BE COPPER THW UNLESS OTHERWISE SHOWN OR REQUIRED BY CODES. 1-#6 14. WIRE SIZES NOT SHOWN ON DRAWINGS SHALL BE SELECTED IN ACCORDANCE WITH THE NEC AMPACITY AND DERATING REQUIREMENTS. 15. ALL HOME RUNS OF 80 FEET AND OVER FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL BE A MINIMUM OF #10THW. 16. THERE SHALL NOT BE MORE THAN A 9-A & 13-A LOADS ON 15-A & 20-A RECEPTACLE CIRCUITS, RESPECTIVELY. 17. CONDUCTORS IN WIREWAYS ARE TO MATCH CONDUCTORS FEEDING DISCONNECTS. RUN CONDUCTORS THE FULL LENGTHS OF WIREWAYS. 18. CONDUITS SHALL BE ELECTRICAL METALLIC TUBING. FLEX -PLUS (ENMT) AND ROMEX MAY BE USED WHERE ALLOWED BY CODE. PVC MAY BE USED OUTDOORS AS ALLOWED BY CODE. 19. FLEXIBLE CONDUIT SHALL BE USED FOR EQUIPMENT CONNECTIONS NOT TO EXCEED SIX (6) FEET. 20. ALL COMMUNICATION CABLES TO OUTLETS AND JUNCTION BOXES SHALL BE IN CONDUITS. 21. THERMOSTATS AND CONTROL CIRCUITS BETWEEN AIR HANDLERS AND CONDENSING UNITS SHALL BE IN CONDUITS. 22. ALL CONDUITS SHALL BE CONCEALED EXCEPT AS NOTED, AND SHALL BE SIZED TO ACCOMMODATE THE REQUIRED SIZE AND NUMBER OF CONDUCTORS. 23. EXPOSED CONDUITS RUN PARALLEL TO WALLS. 24. MAIN DISCONNECTS SHALL BE HEAVY DUTY FUSED SWITCHES WITH CURRENT LIMITING FUSES WITH REJECTION CLIPS. 25. SWITCHES SHALL BE QUIET TYPE. ALL RECEPTACLES SHALL BE GROUND TERMINAL. 26. INSTALL SWITCHES AT 42" A.F.F. AND RECEPTACLES AT 12" A.F.F. EXCEPT AS NOTED OTHERWISE. 27. EVERY PANELBOARD OR LOAD CENTER SHALL BE EQUIPPED WITH TWO 20-A/SINGLE PHASE SPARE BREAKERS. FLUSH PANELS SHALL NOT PROTRUDE. THE WALL SHALL BE VERIFIED FOR THE DEPTH OF THE PANELS. PROVIDE TYPED WRITTEN DIRECTORIES FOR THE PANELS. 28. PULL AND JUNCTION BOX SIZES SHALL MEET THE REQUIREMENTS OF THE NEC. 29. INSTALL 120-V GFI, WEATHERPROOFED DUPLEX OUTLETS ADJACENT TO CONDENSING UNITS. 30. INSTALL ARC FAULT INTERRUPTERS FOR RECEPTACLES AND LIGHTING IN ALL BEDROOMS. 31. PROTECT POWER SERVICES FROM LIGHTNING WITH TRANSIENT VOLTAGE SURGE SUPPRESSOR (TVSS) MANUFACTURED BY SQUARE D AT INCOMING SERVICES AT MAIN DISCONNECTS AND AT PANEL BOARDS. PROVIDE PROTECTION FOR EACH PHASE TO GROUND. PROVIDE SURGE SUPPRESSION RECEPTACLES MANUFACTURED BY HUBBLE FOR ALL ELECTRONIC EQUIPMENT SUCH AS COMPUTERS, FAX MACHINES,... CONSULT ARCHITECT FOR LOCATIONS. 32. ALL FEEDERS, SUBFEEDERS AND BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED AFTER ACCURATE ELECTRICAL DATA OF THE EQUIPMENTS IS KNOWN. 33. LOAD DATA IS BASED ON INFORMATION GIVEN AT THE TIME OF DESIGN. VERIFY SIZE, CONDUCTOR, PROTECTION DEVICE, ETC. REQUIREMENTS OF ALL EQUIPMENTS PRIOR TO ORDERING OR INSTALLATIONS. o I CO NOTE: THIS ELECTRICAL PLAN IS .� INTENDED TO INDICATE THE r n REQUIREMENTS OF THE THE l OWNER. THE DETAILS OF THE �� ELECTRICAL SYSTEM SHALL BE E DETERMINED BY AN ELECTRICAL v CONTRACTOR LICENSED ACCORDING TO CHAPTER 489 OF W FLORIDA STATUTES AND BY THE co LOCAL BUILDING DEPARTMENT. THIS DESIGN IS ALLOWED BY ''�'" b CHAPTER 471 FPR 600 AMP OR ._L_, >~ LESS RESIDENTIAL SERVICES OR ° 800 AMP OR LESS COMMERCIAL U OR INDUSTRIAL SERVICES. (y o O pq I 1~ z Cd 0 a T >r i �+ 4 U f o z O 0 � i�iW � T uJ J a O yo S 3 a k n F� LL U W W �1 F� W W ® e W V .L W ' v O� W ILIcy-) Job No. 09-105 Seal L� Ro r P. Janssen AR-14785 Drawing No. E - 2.5 QC Copyright 2010 Dailey Janssen Architects, P.A. All rights reserved. " ' -- - -- - - - - L N�6 z 4 < / �I I I� I�I I I I Ifrr - 2"W 114 ' F ---- -- _ nil + ---- -- - FIRE LACE NA URAL " E 1 y( - _ lY I 4" FLOOR P TT _- 4 r LOGGIA -- --- ---4 - -- 123 I 1 14 1E: I PE FOOT 1 - - -+ +. 2.3 � I ---- --- -- - - - - - - - - - - - - - - - - - - - ----�- --- I I'I I LANDSCAPE -I v _ II II II I 4' ' F-- -I- - - - i I I I 11 f II QNI M G II I I 0 I fi - 11 \ I I I --T, --------- I - GAS WM TOP & III - -ELECTRIC ANCE I I - 1 DEIL SDI IW/, I AL II I II o o III I STORAGE pyy II I I I.I I BELOW I I II II L-- o a I I I _ I I 7 ------ -- --J�J-STORAGE-_ KNEE SPACE BELOW �1118 1 - n 1 " I 48" FULL -HEIGHT f�EF/F7R CABINET 1 -- I- I - t I \\\ I_ -- C- D - I 40 Elm 4� M I I! I U II -II I 4 -� {j - i - I - O. CH I 1 - I tNa I I p I'I+ I I I I I I I I I I r3LOPE: I P R FOOT II II 1 � II I I II II I I I I I I li I I �,j_L 40 - L L-_ J -- ---- - - ' 1 I - � f I !I II I 11, I - - 4110 WA L 1'4 LINT TV 21 307 - -_ - -- -- LJ-- --- =- -- =-- -- - - - 4 I I 1 1 I I i I f 4 \\ II s1177 o aEAvs' wjr� EA. CU-1 CU-2 , CU-3 IO" MIN. DEM 12' FRAM POLE - - - -I -- - - - 4 CD B Fl D) arfi"IW First Roor Fhsh Man I J _ — SCALE VIC -1'-W t 1 _1 r ��o��oo�0000a ��00000�oo��: • • l • r 0 CQ I 10, �CQ 0 N I I OOm Z. O 0Q 00 OI v] w A OC Job No, 09-105 J` Seel b1•0 "1Z Rger P. Janssen AR-14785 n Copyright 2010 Dailey Janssen Architects, P.A. All rights reserved.