HomeMy WebLinkAboutProject Information � U'U
�
i
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code-Building
INSTRUCTION PAGE o ,�
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Required Sections of Attachments Required
Roof System the Permit Application See List Below
Form
Low Slope Application A,B,C 1,2;34,5,6;7
Prescriptive BUR-RAS 150 A,B,C 2,4,506,7
Asphaltic Shingles A,B, D
1;Z SA 7
Concrete or Clay Tile A, B, D,E 1,2,34., , .7
Metal Roofs A,B, D
Wood Shingles and A, B,D 324;5,67
Shakes
Other As Applicable j2,345g7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128
4. Other Component of Product Approval
S. Municipal Permit Application
6. Owners Notification for Roofing Considerations(Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
i
Form RoofinfoFeb21 Rev Feb 18,2021
i
Section A(General Information)
Master Permit No. Process No.
Sunrise City CHDO Inc CCC1327208
Contractors Name: License#
Job Address 7507 BANYAN ST Fora Pierce, FL 34951
ROOF CATEGORY
.1Low Slope 0 Mechanically Fastened Tile 13 Mortar/Adhesive Set Tiles
Asphaltic Shingles 0 Metal Panel/Shingles ElWood Shingles/Shakes
13 Prescriptive BUR-RAS 150
ROOF ROOF TYPE
0 New roof 13 Repair ❑ Maintenance V Reroofing 0 Recovering
-ROOF SYSTEM INFORMATION
Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) 1028 ;Total(SF) 1028
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
"
10
"
27,
i
U
i BA9Y' 3,
CPPR.:
22 5 e
r
<y ,
_r- a
S ction C(Low Slope Roof) Surfacing:
Fill specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attach nt:
manu cturer Zone 1':—"oc @ Lap,#Rows
(If a co onent is not used,identify as"NA") Zone 1:—"oc @Lap,#Rows
System M ufacturer: Zone 2:_.._."oc @ Lap,#Rows
Zone 3:_.._." oc @ Lap,#Row = W -- '�
Product Appro I No.:
Number of Fasteners Per Insula ' n Board:
Design Wind Pressu s,From RAS 128 Or Calculations: Zone 1': Zone 1: one 2: Zone 3:
Zone 1':_Zone 1: Zone 2: Zone 3: Illustrate Components N ed and Details as Applicable:
Maz. Design Pressure,fro the specific product approval Woodblocking, Gut r, Edge ' Termination, Stripping,
system: Flashing, Continuo s Cleat, Cant Strip, Base Flashing,
Counterflashing, oping, Etc.,
Deck: Indicate: Mean oof Height, Parapet Height, Height of Base
Type: Flashing,Co ponent Material,Material'Thickness,Fastener
Gauge Thickness: Type,Fast er Spacing or Submit Manufacturers Details that
Comply ith RAS 111 and Chapter 16..
Slope:
Anchor/Base Sheet&No.df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
FT.
Insulation Base Layer:
Base Insultation Size and Thickness: Parapet
Base Insulation Fastener/Bonding Material: Height
Top Insulation Layer:
Top Insulation Size and Thickness: FT.
Top Insulation Fastener/Bonding Mater' I:
Mean
Base Sheet(s)&No.of Ply(s): Roof
Base Sheet Fastener/Bonding ateria1: Height
Ply Sheet(s)'&No.ofPI s):
Ply Sheet Fastener/B Material:
Top Pl/tener/Bonding
Top Ply Material:
Section D (Steep Slope Roof System)
Roof System Manufacturer: Wens Corning
Notice of Acceptance Number:
FL10674
Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations):
Zone 1:-07.8 Zone 2e:-a7.e Zone 2n:"76-0 Zone 2r:"76'0 Zone 3e:$1•7 Zone 3r:
Deck Type:' plywood'
Type lnderlayment: Synthetic
Roof$lope
I
InsWaon., None7771
Firs'Bamer I None
RidgeUentdabo6 yeS :' Fastener,Type&Spacing g°D Ring Shank;6"bC
=Adhesive°TYPe� N/A
TYPe.Cap'Sheet N/A
MeanrRaaF HeightRoof Covering:r' Shingles
Type Side Drip 3"x 3" Alurninun
Edge:
I
-t
Section E(Tile Calculations)
For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values lues fro Mr.if the Mf values
e greater than or equal to the Mrvalues,for each area of the roof,then the tile attachment method is ceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: X'�i Mg — Product Approval M
(Zone 2e: Mg; -gym Product Approval
(Zone 2n: frig; =Mm, Product Approval
(Zone 2r: X�, _ Mg; Mrtr. Product Approval f
one 3e: ,1M� Product Appro IMf
( ne 3r: 4X Mgi ^Mrat _ Product Appr val Mf
Method 2"Simplified Tile Calculations Per Table Bel "
Required Moment of esistance(Mr)From Table Below Product Approval Mf
Mr required Moment Resistance*
Mean Roof Height Roof op e 15, 20' 25' 30' 40'
2:12 34.4 36.5 38.2 39.7 42.2
3:12 32.2 34.4 36.0 37.4 39.8
4:12 30.4 32.2 33.8 35.1 37.3
5:12 28.4 30.1 31.6 32.8 34.9
6:12 .4 28.0 1 29 4 30.5 32.4
7:12 24. 25.9 A., 28.2 30.0
*Must be used in conjunction with a list o moment based tile sy ems
• For Uplift based tile systems use Method 3.Compare the valu s for F'with the values for Fr If the F'values are greater than or
equal to the Fr values,for each area of the ro then the tile ttachment method is acceptable.
Method 3" lift Base Tile Calculations Per RAS 12T
(Zone 1: x L =x W:= )-W: cos =Fri Product Approval F'
(Zone 2e: x L =x W:= )-W: s r =Fae Product Approval F'
(Zone 2n: x L =x W:= )-W: c r =Fan Product Approval F'
(Zone 2r: x L =x W:= )-W: cos =Far Product Approval F'
(Zone 3e: x L =x W:= )-W: cos r =Fr3e Product Approval F'
(Zone 3r: x L =x W:= )-W: cos r =Fr3r Product Approval F'
Where to Obtain InforiRation
Description Symbol Where to find;
Design Pressure Zo es 1,2e,2n,2r,3e,3r From apple ble table in RAS 127 or by an engineering analysis
prepared by based on ASCE 7
Mean Roof Height H Job Site I
Roof Slope 0 Job Site
Aerodynamic Multiplier a Product Approval
Restoring Moment due to Grave Mg Product Approval
Attachment Resistance Mf Product Approval
Required Moment Resista a Mg Calculated
Minimum Attachment sistance F' Product Approval
Required Uplift Resis nce Fr Calculated
Average Tile Weig W Product Approval
Tile Dimensions L=length W=width Product Approval
All calculatio must be submitted to the building official at the time of permit application.