Loading...
HomeMy WebLinkAboutProject Information � U'U � i ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code-Building INSTRUCTION PAGE o ,� COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A,B,C 1,2;34,5,6;7 Prescriptive BUR-RAS 150 A,B,C 2,4,506,7 Asphaltic Shingles A,B, D 1;Z SA 7 Concrete or Clay Tile A, B, D,E 1,2,34., , .7 Metal Roofs A,B, D Wood Shingles and A, B,D 324;5,67 Shakes Other As Applicable j2,345g7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128 4. Other Component of Product Approval S. Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation i Form RoofinfoFeb21 Rev Feb 18,2021 i Section A(General Information) Master Permit No. Process No. Sunrise City CHDO Inc CCC1327208 Contractors Name: License# Job Address 7507 BANYAN ST Fora Pierce, FL 34951 ROOF CATEGORY .1Low Slope 0 Mechanically Fastened Tile 13 Mortar/Adhesive Set Tiles Asphaltic Shingles 0 Metal Panel/Shingles ElWood Shingles/Shakes 13 Prescriptive BUR-RAS 150 ROOF ROOF TYPE 0 New roof 13 Repair ❑ Maintenance V Reroofing 0 Recovering -ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) 1028 ;Total(SF) 1028 Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. " 10 " 27, i U i BA9Y' 3, CPPR.: 22 5 e r <y , _r- a S ction C(Low Slope Roof) Surfacing: Fill specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attach nt: manu cturer Zone 1':—"oc @ Lap,#Rows (If a co onent is not used,identify as"NA") Zone 1:—"oc @Lap,#Rows System M ufacturer: Zone 2:_.._."oc @ Lap,#Rows Zone 3:_.._." oc @ Lap,#Row = W -- '� Product Appro I No.: Number of Fasteners Per Insula ' n Board: Design Wind Pressu s,From RAS 128 Or Calculations: Zone 1': Zone 1: one 2: Zone 3: Zone 1':_Zone 1: Zone 2: Zone 3: Illustrate Components N ed and Details as Applicable: Maz. Design Pressure,fro the specific product approval Woodblocking, Gut r, Edge ' Termination, Stripping, system: Flashing, Continuo s Cleat, Cant Strip, Base Flashing, Counterflashing, oping, Etc., Deck: Indicate: Mean oof Height, Parapet Height, Height of Base Type: Flashing,Co ponent Material,Material'Thickness,Fastener Gauge Thickness: Type,Fast er Spacing or Submit Manufacturers Details that Comply ith RAS 111 and Chapter 16.. Slope: Anchor/Base Sheet&No.df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: FT. Insulation Base Layer: Base Insultation Size and Thickness: Parapet Base Insulation Fastener/Bonding Material: Height Top Insulation Layer: Top Insulation Size and Thickness: FT. Top Insulation Fastener/Bonding Mater' I: Mean Base Sheet(s)&No.of Ply(s): Roof Base Sheet Fastener/Bonding ateria1: Height Ply Sheet(s)'&No.ofPI s): Ply Sheet Fastener/B Material: Top Pl/tener/Bonding Top Ply Material: Section D (Steep Slope Roof System) Roof System Manufacturer: Wens Corning Notice of Acceptance Number: FL10674 Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations): Zone 1:-07.8 Zone 2e:-a7.e Zone 2n:"76-0 Zone 2r:"76'0 Zone 3e:$1•7 Zone 3r: Deck Type:' plywood' Type lnderlayment: Synthetic Roof$lope I InsWaon., None7771 Firs'Bamer I None RidgeUentdabo6 yeS :' Fastener,Type&Spacing g°D Ring Shank;6"bC =Adhesive°TYPe� N/A TYPe.Cap'Sheet N/A MeanrRaaF HeightRoof Covering:r' Shingles Type Side Drip 3"x 3" Alurninun Edge: I -t Section E(Tile Calculations) For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values lues fro Mr.if the Mf values e greater than or equal to the Mrvalues,for each area of the roof,then the tile attachment method is ceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: X'�i Mg — Product Approval M (Zone 2e: Mg; -gym Product Approval (Zone 2n: frig; =Mm, Product Approval (Zone 2r: X�, _ Mg; Mrtr. Product Approval f one 3e: ,1M� Product Appro IMf ( ne 3r: 4X Mgi ^Mrat _ Product Appr val Mf Method 2"Simplified Tile Calculations Per Table Bel " Required Moment of esistance(Mr)From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof op e 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 .4 28.0 1 29 4 30.5 32.4 7:12 24. 25.9 A., 28.2 30.0 *Must be used in conjunction with a list o moment based tile sy ems • For Uplift based tile systems use Method 3.Compare the valu s for F'with the values for Fr If the F'values are greater than or equal to the Fr values,for each area of the ro then the tile ttachment method is acceptable. Method 3" lift Base Tile Calculations Per RAS 12T (Zone 1: x L =x W:= )-W: cos =Fri Product Approval F' (Zone 2e: x L =x W:= )-W: s r =Fae Product Approval F' (Zone 2n: x L =x W:= )-W: c r =Fan Product Approval F' (Zone 2r: x L =x W:= )-W: cos =Far Product Approval F' (Zone 3e: x L =x W:= )-W: cos r =Fr3e Product Approval F' (Zone 3r: x L =x W:= )-W: cos r =Fr3r Product Approval F' Where to Obtain InforiRation Description Symbol Where to find; Design Pressure Zo es 1,2e,2n,2r,3e,3r From apple ble table in RAS 127 or by an engineering analysis prepared by based on ASCE 7 Mean Roof Height H Job Site I Roof Slope 0 Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Grave Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resista a Mg Calculated Minimum Attachment sistance F' Product Approval Required Uplift Resis nce Fr Calculated Average Tile Weig W Product Approval Tile Dimensions L=length W=width Product Approval All calculatio must be submitted to the building official at the time of permit application.