Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProduct Approval ,underlayments R
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
khrlda
fib)
Product Approval
r ,
USER:Public User
�u^�Tr�r#�zvfa I
Product Approval Menu>Product or Aeplication Search>implication List>Application Detail
l - FL# FL15216-R8 � ��®
Application Type Revision �� rr
Code Version 2020
Application Status Approved
1'i
P
OG� vJG�d���
Comments lei C0' VY
Archived
Product Manufacturer Owens Corning Roofing and Asphalt,LLC
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43645
(740)321-6345
Greg.Keeler@owenscorning.com
Authorized Signature Keeler Greg
Greg.Keeler@owenscorning.com
Technical Representative Greg Keeler
Address/Phone/Email 2790 Columbus Road
Granville,OH 43023 ;
(740)321-6345
greg.keeler@owenscorning.com
_Quality Assurance Representative,
Address/Phone/Email
Category !ofing
Subcategory derlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
i
` Evaluation Report-Hardcopy Received
i
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity Intertek Testing Services NA,Inc.-QA Entity
Quality Assurance Contract Expiration Date 12/31/2023
Validated By John W.Knezevich,PE
In Validation Checklist-Hardcopy Received
Certificate of Independence FL15216 R8 COI 2020 01 COI NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D226(physicals) 2009
ASTM D4533(tear strength) 2015
ASTM D4798(weathering) 2011
ASTM D4869(liquid transmission) 2016
ASTM D5035(tensile strength) 2011
Equivalence of Product Standards
Certified By
I
I
T
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 12/16/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
Date Revised 06/15/2021
Summary of Products
FL# Model,Number or Name Description
15216.1 RhinoRoof U20,ABC Pro Guard 20 Synthetic roof underlayments
and SRS TopShield TS20 Roof
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15216 R8 II 2020 12 15 FINAL ER OWENS
Approved for use outside HVHZ:Yes CORNING RHINOROOF FL15216-R8.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See ER Section 5 for Limits of Use. Evaluation Reports
FL15216 R8 AE 2020 12 15 FINAL ER OWENS
CORNING RHINOROOF FL15216-R8.1Ldf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic.
.mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455:275(i),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
Credit Card,
Safe j
NEMO etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
i
a � •
Owens Corning Roofing and Asphalt,LLC Evaluation Report 140510.02.12-119
One Owens Corning Parkway FL15216-118
Toledo,OH 43659 Date of Issuance:02/17/2012
(740)321-6345 Revision 9:12/15/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been-reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 7'Edition(2020) Florida Building Code sections noted herein.
DESCRIPTION: ,Mind Roof U20,ABC PrO Guard.20 and,SRS TopShield TS20,Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). I.NEM0 ETC, LLC requires.a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval.Number (FL#) preceded by the words "NEMOietc. Evaluated" may.be
displayed in.advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.'
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official..
This Evaluation Report consists of pages 1 through 4.
j
Prepared by:
Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 �ai; ;„� `''~ Nieminen,P.E.on 12/15/2020.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,R.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 NEMO ETC,LLC
i
ONEMO etc.
ROOFING COMPONENT EVALUATION:
lit
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: RhinoRoof U20,ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments, as
produced by Owens Corning Roofing and Asphalt,LLC,have demonstrated compliance with the following sections
of the 7ThEdition (2020) Florida Building Code through testing in accordance with applicable sections of:the
following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use
.set forth herein.
. •ARD
Section. Properties. _ Standard . , Year
1507.1.1.1(2&3,Exception), Tear,strength ASTM D4533 2015
1507.1.1.1(5)/R905.1.1.1(2&3,
Exception),R905.1.1.1(5)
1507.1.1.1(2&3,Exception), Tensile strength ASTM D5035 2011
1507.1.1.1(5)/R905.1.1.1(2&3,
Exception),R905.1.1.1(5)
1507.1.1.1(5)/R905.1.1.1(5) Liquid water transmission ASTM D4869: 2016
1518.41'RAS 115 Unrolling,Breaking Strength,Pliability ASTM D226 2009
TAS 110 Accelerated Weathering ASTM D4798 2011
Enti Examination Reference- Date_
__._.._ � ...- .v_ _ ... _.- v _ .._"_ .v._-
ITS(TST1509) ASTM D226 100539395COQ-006 10/26/2011
ITS(TST1509) ASTM D4869 100539395COQ-002 10/26/2011
PRI(TST5878) ' ASTM D226/D4798/D4869 OCF-394-02-07.4 01/66/2020
PRI(TST5878) ASTM D226/D4798 OCF-464-02-02.2 01/06/2020.
PRI(TST5878) ASTM D4533/D5035/D4798 1378TO109 10/15/2020
PRI(TST5878). ASTM D4533/D5035 1378T0127 10/15/2020
ITS(QUA1673) Quality Control Service Confirmation 12/09/2020
ITS(QUA1673) Quality Control Florida BCIS Current
PRODUCT •
xe- t Specification Plant(s)i Description.
4.1 RhinoRoof U20 1507.1.1.1(2&3,Exception), Qingdao,China Multilayered polymer woven
1507.1.1.1(5)/R905.1.1.1(2&3, coated synthetic roof
Exception),R905.1.1.1(5) underlayment
4.2 ABC Pro Guard 20 1507.1.1.1(2&3,Exception), Silvassa, India Multilayered polymer woven
1507.1.1.1(5)/R905.1.1.1(2&3, coated synthetic roof
Exception),R905.1.1.1(5) underlayment
43 SRS TopShield TS20 1507.1.1.1(2&3,Exception), Silvassa, India Multilayered polymer woven
1507.1.1.1(5):/R905.1.1.1(2&3, coated synthetic roof
Exception),R905.1.1.1(5) underlayment
MEMO ETC,LLC Evaluation Report 140510.02.12-119
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ AND HVHZ EVALUATION FL15216-118
RhinoRoof U20,ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 9:12/15/2020
Page 2 of 4
i
i. N Em:o etc.
LI , .
5.1 This is a building_code evaluation. Neither NEW ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.3 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or.FBC HVHZ 1516 for
requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and
limitations concerning the use of foam plastic insulation.
5.4 RhinoRoof U20,ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments may be used with any prepared
roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request
may be made to the Authority Having Jurisdiction for approval based on this evaluation(combined with supporting
data for the prepared roof covering.
5.5 Allowable roof covers:
TABLE 1 ROOF.°COVER OPTIONS•' s�f
FBC NON HVHZ: 1507.2 15073 1507.4$1507.5 15077 1507.8&1507.9
TAS 110(Sll),
- FBC HVHZ: TAS I10(SIO),RA5115 RAS 133 TAS 110(S11)'_' RAS 130
-,?AS 118,119$120 r
77
Clay and Concrete - .Slate or'Slate-Type _
Underlayment Asphalt Shingles Metal" i Wood
Tile Shingles -_ -
RhinoRoof U20 Yes No Yes No NON-HVHZ: No
HVHZ: Yes
NON-HVHZ: No
ABC Pro Guard 20 Yes No. Yes No HVHZ: Yes
SRS TopShield TS20 Yes No Yes No i NON-HVHZ: No
HVHZ: Yes
5.6 Exposure Limitations:
TABLE 2: EXPOSURE LIMITATIONS`.,,` s
. •
Underlayment= Maximum Exposure(days)
RhinoRoof U20 60
ABC Pro Guard 20 30
SRS TopShield TS20 30
i
NEMO ETC,LLC Evaluation Report 140510.02.12-119
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ AND HVHZ EVALUATION FL15216-118
RhinoRoof U20,ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 9:12/15/2020
Page 3 of 4
0- NEM0 etc.
6.1 RhinoRoof U20,ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments shall be installed in accordance
with the manufacturer's published installation instructions subject to the Limitations set forth in Section 5 herein
and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application.
6 3= noR'ooi.U20,ABC Prd Guatd 20 and SRS TopShield TS20 Roof`Underlayments: -
6.3.1 NOWHVHZJurisdictlons
6.3.1.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception),
1507.1.1.1(3,Exception)or 1507.1.1.1(5)or FBC Residential R905.1.1.1(2,Exception),R905.1.1.1(3,Exception)
or R905.1.1.1(5) for.the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
6.3.1.2 Fasteners:
Minimum fasteners shall be corrosion resistant, ring-shank cap nails shall be as set forth in FBC 1507.1.1.1 or
1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3.
6.3.2 HVHZ;Jurisdicfi6ns-
6.3.2.1 Shall be installed in a shingle fashion with minimum 4-inch wide side(horizontal)laps and minimum 6-inch wide
end laps,and fastened in accordance with FBC HVHZ 1518.2.
BUILDING PERMIT •
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
MANUFACTURING PLANTS*
Contact the named QA entity for manufacturing'facilities covered by F.A.C. Rule 61G20-3 CA requirements.
Refer to Section 4 herein for products and production locations.having met codified material standards.
Intertek Testing Services NA Inc.—QUA1673;(312)906-7779;maura.norlander@intertek.com
-END OF EVALUATION REPORT-
NEW ETC,LLC Evaluation Report 140510.02.12-119
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ AND HVHZ EVALUATION FL15216-118
RhinoRoof U20,ABC Pro Guard 20 and SRS TopShield T520 Roof Underlayments Revision 9:12/15/2020