HomeMy WebLinkAboutEnergy Code'w FORM R405-2020 RECEIVED
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING MARRUCTION
r Florida Department of Business and Professional Regulation ResidentiqeF,fnMethod
St. Lucie
Project Name: Lot 61 Block 1 Waterstone 2000 AGL
Builder Name: -ADAMS HOMES
Street: 8701 Merano Avenue
Permit Office: '
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Type$1941.1 sgft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1428.20 ftz
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
c. Frame - Wood, Exterior
R=13.0 288.56 ftz
R=13.0 224.40 ftz
4. Number of Bedrooms
4
d. N/A
R= ftz
5. Is this a worst case?
No
11. Ceiling Types (2084.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2004.00 ftz
6. Conditioned floor area above grade (ftz)
2004
b. Knee Wall (Vented)
R=19.0 80.00 ftz
Conditioned floor area below grade (ftz)
0
c. N/A
R= ftz
7. Windows(193.0 sgft.) Description
Area
12. Ducts
R ftz
a. U-Factor: Dbl, U=0.33
142.83 ftz
a. Sup: Attic, Ret: Main, AH: Main
6 400.8
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
32.38 ftz
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55
17.78 ftz
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth:
4.940 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.270
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights
Area
c. U-Factor:(AVG) N/A
ftz
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2004.0 sgft.)
Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation
R=0.0 2004.00 ftz
b. Conservation features
b. N/A
R= ftz
None
c. N/A
R= ftz
16. Credits
Pstat
Glass/Floor Area: 0.096
Total Proposed Modified Loads: 60.87
PASS
Total Baseline
Loads: 61.06
I hereby certify that the plans a .
cations covered �
Revie of the plans and
��TTiB;STg?8
this calculation are in compli
ergy
specifications covered by this
•-,
p.
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: ns- i
KPnmany
this building will be inspected for
s
X.
compliance with Section 553.908-_-
I hereby certify that this building, as desisne_'d is in compliance
Florida Statutes.
with the Florida nerg
p
OWNERZX ENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.50 ACH50 (R402.4.1.2). RECEIVED
AUG-2 0 2021
Permitting Department
St. Lucie County
8/17/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
'
PROJECT
Title:
Lot 61 Block 1 Waterstone 20 Bedrooms: 4
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 2004
Lot #
61-1
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
8701 Merano Avenue
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/ Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2004 18837.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished
Cooled
Heated
1
Main
2004 18837.6 Yes 5
4
1
Yes
Yes
Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 181.9 ft 0
2004 ftz
---- 0.35 0 0.65
ROOF
/
Roof Gable Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
#
Type
Materials Area Area Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Gable or Shed Composition shingles 2241 ftZ 502 ft2 Medium
N
0.85
N 0.85
No 0
26.57
ATTIC
V
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Vented 300 2004 ftz
N
N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented)
Main 30 Blown
2004 ftZ
0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
80 ftz
0.11
Wood
8/17/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
` WALLS
Adjacent Space Cavity Width Height
F
Sheathing Framing Solar Below
0
^
_ 1 E
Exterior Concrete Block - Int Insul Main
4.1 53 7
9 7 513.5 ft2
0
0 0.6
0
2 N
Exterior Concrete Block - Int Insul Main
4.1 20 0
9 4 186.7 ft2
0
0 0.6
0
3 W
Exterior Frame - Wood Main
13 25 2
8 11 224.4 ft2
0
0.23 0.6
0
4 W
Exterior Concrete Block - Int Insul Main
4.1 39 0
9 4 364.0 ft2
0
0 0.6
0
5 S
Exterior Concrete Block - Int Insul Main
4.1 37 4
9 9 364.0 ft2
0 0.6
0
6 -
Garage Frame - Wood Main
13 30 11
9 4 288.6 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
Wood Main
None
.25 2
8
6 8
17.8 ft2
2
N Insulated Main
None
.25 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1
E 1 Vinyl Low-E Double Yes
0.33 0.23 N
13.3 ft2 1 ft 5 in
0 ft 9 in
None
None
2
E 1 Vinyl Low-E Double Yes
0.33 0.23 N
16.2 ft2 1 ft 5 in
0 ft 9 in
None
None
3
N 2 Vinyl Low-E Double Yes
0.33 0.21 N
32.4 ft2 1 ft 5 in
4 ft 0 in
None
None
4
W 3 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2 1 ft 5 in
0 ft 9 in
None
None
5
S 5 Vinyl Low-E Double Yes
0.55 0.7 N
17.8 ft2 11 ft 8 in
1 ft 0 in
None
None
6
S 5 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2 1 ft 5 in
0 ft 9 in
None
None
7
S 5 Vinyl Low-E Double Yes
0.33 0.23 N
48.6 ft2 11 ft 8 in
0 ft 9 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
754 ft2 754 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000388 2040.7 111.96 210.19 .1251
6.5
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5
34.6 kBtu/hr
1
sys#1
1
8/17/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FOP,M R405-2020 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cart # Company Name System Model # Collector Model # Area Volume FEF
None None ftz
DUCTS
/
---- Supply ----
----
Return ----
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
Leakage
Type
Handler
TOT
OUT QN
RLF
Heat Cool
1
Attic
6 400.8 ft Main
100.2 ft
Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Heating
Venting
Jan
f X Jan
Feb
f X� Feb
Mar
Mar
Apr
f Apr
f
May
May
Jun
Jun
rl
Jul
Jul
rl
u
Mug Aug
Se
Sep
ri
Oct
Oct
Nov
Nov
Dec
XDec
[ Jan
[ Feb
X
Mar
[X] A r
[
Ma
Jun
Jul
Se
[
Oct
X Nov
[ Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
80
80
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
68
66
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/so.ft.
0 ftZ
0 ft
0.3
Main
8/17/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FURM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
M
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
~ The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows- Description
a. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.70
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
8701 Merano Avenue, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1428.20 ftz
b. Frame - Wood, Adjacent
R=13.0
288.56 ftz
1
c. Frame - Wood, Exterior
R=13.0
224.40 ftz
4
d. N/A
R=
ftz
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2004.00 ftz
2004
b. Knee Wall (Vented)
R=19.0
80.00 ftz
Area
c. N/A
R=
ftz
142.83 ftz
12. Ducts, location & insulation level
R ftz
a. Sup: Attic, Ret: Main, AH: Main
6 400.8
32.38 ftz
13. Cooling. systems
kBtu/hr
Efficiency
17.78 ftz
a. Central Unit
35.0 SEER:16.00
ftz
14. Heating systems
kBtu/hr
Efficiency
4.940 ft.
a. Electric Heat Pump
34.6
HSPF:8.50
0.270
Area
15. Hot water systems
ftz
a. Electric
Cap:
40 gallons
EF: 0.94
b. Conservation features
Insulation
Area
None
R=0.0
2004.00 ftz
Credits (Performance method)
Pstat
R=
ftz
R=
ftz
I certify that this home has complied with the Florida Energy Efficiency Code for Building '
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact'the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/17/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1