Loading...
HomeMy WebLinkAboutEnergy Code'w FORM R405-2020 RECEIVED FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING MARRUCTION r Florida Department of Business and Professional Regulation ResidentiqeF,fnMethod St. Lucie Project Name: Lot 61 Block 1 Waterstone 2000 AGL Builder Name: -ADAMS HOMES Street: 8701 Merano Avenue Permit Office: ' City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1941.1 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1428.20 ftz 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent c. Frame - Wood, Exterior R=13.0 288.56 ftz R=13.0 224.40 ftz 4. Number of Bedrooms 4 d. N/A R= ftz 5. Is this a worst case? No 11. Ceiling Types (2084.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2004.00 ftz 6. Conditioned floor area above grade (ftz) 2004 b. Knee Wall (Vented) R=19.0 80.00 ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 7. Windows(193.0 sgft.) Description Area 12. Ducts R ftz a. U-Factor: Dbl, U=0.33 142.83 ftz a. Sup: Attic, Ret: Main, AH: Main 6 400.8 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ftz 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.55 17.78 ftz SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 4.940 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.270 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ftz 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2004.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 16. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 60.87 PASS Total Baseline Loads: 61.06 I hereby certify that the plans a . cations covered � Revie of the plans and ��TTiB;STg?8 this calculation are in compli ergy specifications covered by this •-, p. Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: ns- i KPnmany this building will be inspected for s X. compliance with Section 553.908-_- I hereby certify that this building, as desisne_'d is in compliance Florida Statutes. with the Florida nerg p OWNERZX ENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.50 ACH50 (R402.4.1.2). RECEIVED AUG-2 0 2021 Permitting Department St. Lucie County 8/17/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ' PROJECT Title: Lot 61 Block 1 Waterstone 20 Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 2004 Lot # 61-1 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8701 Merano Avenue Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2004 18837.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2004 18837.6 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 181.9 ft 0 2004 ftz ---- 0.35 0 0.65 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2241 ftZ 502 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2004 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2004 ftZ 0.11 Wood 2 Knee Wall (Vented) Main 19 Batt 80 ftz 0.11 Wood 8/17/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ` WALLS Adjacent Space Cavity Width Height F Sheathing Framing Solar Below 0 ^ _ 1 E Exterior Concrete Block - Int Insul Main 4.1 53 7 9 7 513.5 ft2 0 0 0.6 0 2 N Exterior Concrete Block - Int Insul Main 4.1 20 0 9 4 186.7 ft2 0 0 0.6 0 3 W Exterior Frame - Wood Main 13 25 2 8 11 224.4 ft2 0 0.23 0.6 0 4 W Exterior Concrete Block - Int Insul Main 4.1 39 0 9 4 364.0 ft2 0 0 0.6 0 5 S Exterior Concrete Block - Int Insul Main 4.1 37 4 9 9 364.0 ft2 0 0.6 0 6 - Garage Frame - Wood Main 13 30 11 9 4 288.6 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 Wood Main None .25 2 8 6 8 17.8 ft2 2 N Insulated Main None .25 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 13.3 ft2 1 ft 5 in 0 ft 9 in None None 2 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 5 in 0 ft 9 in None None 3 N 2 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 5 in 4 ft 0 in None None 4 W 3 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 5 in 0 ft 9 in None None 5 S 5 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 11 ft 8 in 1 ft 0 in None None 6 S 5 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 5 in 0 ft 9 in None None 7 S 5 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 11 ft 8 in 0 ft 9 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 754 ft2 754 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000388 2040.7 111.96 210.19 .1251 6.5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 1 8/17/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FOP,M R405-2020 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 400.8 ft Main 100.2 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Heating Venting Jan f X Jan Feb f X� Feb Mar Mar Apr f Apr f May May Jun Jun rl Jul Jul rl u Mug Aug Se Sep ri Oct Oct Nov Nov Dec XDec [ Jan [ Feb X Mar [X] A r [ Ma Jun Jul Se [ Oct X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/so.ft. 0 ftZ 0 ft 0.3 Main 8/17/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FURM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD M ESTIMATED ENERGY PERFORMANCE INDEX* = 100 ~ The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Windows- Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.21 c. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.70 d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 8701 Merano Avenue, Fort Pierce, FL, 34951 New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1428.20 ftz b. Frame - Wood, Adjacent R=13.0 288.56 ftz 1 c. Frame - Wood, Exterior R=13.0 224.40 ftz 4 d. N/A R= ftz No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 2004.00 ftz 2004 b. Knee Wall (Vented) R=19.0 80.00 ftz Area c. N/A R= ftz 142.83 ftz 12. Ducts, location & insulation level R ftz a. Sup: Attic, Ret: Main, AH: Main 6 400.8 32.38 ftz 13. Cooling. systems kBtu/hr Efficiency 17.78 ftz a. Central Unit 35.0 SEER:16.00 ftz 14. Heating systems kBtu/hr Efficiency 4.940 ft. a. Electric Heat Pump 34.6 HSPF:8.50 0.270 Area 15. Hot water systems ftz a. Electric Cap: 40 gallons EF: 0.94 b. Conservation features Insulation Area None R=0.0 2004.00 ftz Credits (Performance method) Pstat R= ftz R= ftz I certify that this home has complied with the Florida Energy Efficiency Code for Building ' Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact'the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/17/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1