HomeMy WebLinkAbouthealth departmentSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Michael Zeek AGENT. Wayne St. Pierre (St. Pierre Construction Inc) PROPERTY ADDRESS: 15358 Navion Dr Port Saint Lucie, FL 34987 LOT: 97 BLOCK: APPLICATION # : SOP 1607544 PERMIT #:56-SF-2213775 DOCUMENT #:F11703729 DATE PAID' 12/15/2020 FEE PAID:545.00 RECEIPT #:56-PID-4830105 SUBDIVISION: Treasure Coast Air Park ID#: 4224-501-0097-000-4 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [11 1050.00 [21 [ ] [271 SURFACE WATER 76 FT [ ] [021 TANK MATERIAL Concrete [ ) [281 DITCHES FT [ ] [03] OUTLET DEVICE [ ] [291 PRIVATE WELLS 80 FT [ ] [041 MULTI -CHAMBERED [ Y N ] [ ] [301 PUBLIC WELLS FT [ ] [051 OUTLET FILTER PolylokPL-68 [ ) [311 IRRIGATION WELLS FT [ ] [06] LEGEND 1. 28-015-08DC3 2. [ ] [321 POTABLE WATER 6.5 FT [ ] [07] WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 7 FT [ ] [081 LEVEL [ ] [341 PROPERTY LINES 100 FT [ ] [091 DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [11 510 [21 SQFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 6.00 2. [ ] [38] SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [391 STABILIZATION [ ) [141 DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 8.00 [ ] [40] UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [181 DOSING PUMPS [ ] [42] ALARMS [ ] [191 AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ 1 [21] AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] [221 FILL AMOUNT [ ] [47] CONTRACTOR Bruce T Mc Cullers (Reliable T [ ] [231 FILL TEXTURE [ ] [481 OTHER ADS Septic Stack-9 (9 pipes - 2 tier) [ ] 1241 EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION St. Lucie CHD DISAPPROVED Y nvironmental Specialist I Ma i (Florida Department of He FINAL SYSTEM [ APPROVED / DISAPPROVED ]�St. Lucie CHD nvironmenta pecialist I Matthew �yi-nda Department of H (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1607544 EID2213775 DATE: 07/28/2021 DATE: 10/06/2021 Page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1607544 PERMIT #:56-SF-2213775 DOCUMENT #:F11703729 DATE PAID:12/15/2020 FEE PAID:545.00 RECEIPT # :56-PI D-4830105 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST, filter, and 5x30ft+1x20ft long TRENCH DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final inspection for well inspection/setback, filled system, depth of cover, and final site grading. Pump leading from pond must be dismantled. Final inspection completed. Filled system checked, depth of cover checked, final site grading completed, well inspection/setback completed, and pump leading to pond has been dismantled. Final inspection approved. Emailed copy to building department and contractor. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1607544 EID2213775