HomeMy WebLinkAboutCertification for Design Load ComplianceA
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: Century Complete -1449
'Project Address: 7409 Belleair Ave, Fort Pierce 34951
Permit #: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
Y
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
• DESIGN CODE: Florida 2020 Code Sixth Edition with 20 NSA Supplements using ASCE 7-10
2. Structure Designed. as (check one): X Enclosed Partially Enclosed Open
k,
3. Risk Category: I X II III IV Exposure Category: B X C D
-t 4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: 3.6 ft
5. Mean Roof Height 11 ft Roof Pitch: 4 :12 Parapet: NSA ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10scift @ 15'MRH, clearly label on all plan openings):
Zone 1: +�9.3,-30.6 Zone 2: +19.3,-53.3 Zone 3: +19.3,-78.9 Zone 4: +33.5,-36.3 Zone 5: +33.5,-44.8 Garage: +31.7/-38.6
r:
7. Design Loads: Floor: 40 PSF " Roof/Dead: 17 PSF Roof/Live: 20 Balcony: NSA PSF
Dock:" NSA "PSF Deck: NSA PSF Stairs: NSA PSF Fence: NSA PSF Railings: 50 PSF
8. Were Shear Walls Considered For Structure? Y Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? Y Yes Not Applicable Explain Why Not:
10. Design $oil. Bearing Pressure: 1500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that,.to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County:ll also certify that.structural elements depicted on these plans provide adequate resistance to the design
forces
1 FR®C�B��i,3 James G. Friling
• .
VI •v G S ° °C ei `fir �' Print Name ? _ Cert # & Co. Cert Auth.
��Q ® No 77824 as
PE #77824 COA #27228
.� w„ • it
i Okurex3pmcloFal ° o / Mulhern + Kulp Structural Engineering - 300 Brookside Ave, Ambler, PA 19002
0,%.• C. W° °�� Company Name & Address
Revi M,(���g
I� v I�fHL a
,_. � ow� �-
��I/11111111® a