Loading...
HomeMy WebLinkAboutCertification for Design Load ComplianceA Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Century Complete -1449 'Project Address: 7409 Belleair Ave, Fort Pierce 34951 Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. Y DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) • DESIGN CODE: Florida 2020 Code Sixth Edition with 20 NSA Supplements using ASCE 7-10 2. Structure Designed. as (check one): X Enclosed Partially Enclosed Open k, 3. Risk Category: I X II III IV Exposure Category: B X C D -t 4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: 3.6 ft 5. Mean Roof Height 11 ft Roof Pitch: 4 :12 Parapet: NSA ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10scift @ 15'MRH, clearly label on all plan openings): Zone 1: +�9.3,-30.6 Zone 2: +19.3,-53.3 Zone 3: +19.3,-78.9 Zone 4: +33.5,-36.3 Zone 5: +33.5,-44.8 Garage: +31.7/-38.6 r: 7. Design Loads: Floor: 40 PSF " Roof/Dead: 17 PSF Roof/Live: 20 Balcony: NSA PSF Dock:" NSA "PSF Deck: NSA PSF Stairs: NSA PSF Fence: NSA PSF Railings: 50 PSF 8. Were Shear Walls Considered For Structure? Y Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? Y Yes Not Applicable Explain Why Not: 10. Design $oil. Bearing Pressure: 1500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that,.to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County:ll also certify that.structural elements depicted on these plans provide adequate resistance to the design forces 1 FR®C�B��i,3 James G. Friling • . VI •v G S ° °C ei `fir �' Print Name ? _ Cert # & Co. Cert Auth. ��Q ® No 77824 as PE #77824 COA #27228 .� w„ • it i Okurex3pmcloFal ° o / Mulhern + Kulp Structural Engineering - 300 Brookside Ave, Ambler, PA 19002 0,%.• C. W° °�� Company Name & Address Revi M,(���g I� v I�fHL a ,_. � ow� �- ��I/11111111® a