Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
�+ wrightsoft® Project Summary House One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.0neStopCooling.00m License: CAM 817652 For: Wade Jumey Homes FL Notes: Design Information Weather: Winter Design Conditions Outside db 43 OF Inside db 68 OF Design TD 25 OF Heating Summary Structure 10954 Btuh Ducts 1296 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 12250 Btuh Infiltration Method Construction quality . Fireplaces Melbourne Regional, FL, US Simplified Semi -tight 0 Heating Cooling Area (ft� 1422 1422 Volume (ft3) 11378 11378 Air changes/hour 0.31 0.16 Equiv AVF (cfm) 59 30 Heating Equipment Summary Make Carrier Trade Model CH14NBO2400GOA0 AHRI ref 9162301 Efficiency 8.2 HSPF Heating input Heating output 22200 Btuh @ 470F Temperature rise 0 OF Actual airflow 0 cfm Airflowfactor 0 cfm/Btuh Static pressure 0 in H2O Space thermostat Capacity balance point = 29 OF Backup: _ Input=13 kW, Output=43093 Btuh,100 AFUE Job: 7409 Belleair Ave 1449E R.. Date: 07/23/20 By-. WIN Summer Design Conditions Outside db 91 OF Inside db 74 OF Design TD 17 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/Ib Sensible Cooling Equipment Load Sizing Structure 12748 Btuh Ducts 2698 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data . n Rate/swing multiplier 0.96 Equipment sensible load 14767 Btuh Latent Cooling Equipment Load Sizing Structure 3664 Btuh Duds 739 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 4403 Btuh Equipment Total Load (Sen+Lat) 19170 Btuh Req. total capacity at 0.75 SHR 1.6 ton Cooling Equipment Summary Make Carrier Trade Cond CH14NBO2400GOA0 Coil FB4CNP025L AHRI ref 9162301 Efficiency 11.5 EER,14.5 SEER Sensible cooling 16650 Btuh Latent cooling 5550 Btuh Total cooling 22200 Btuh Actual airflow 740 cfm Air flow factor 0.048 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.78 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -*- wrightsoft ° 2021-Jan-25 09:46:17 ..,•_.-. ...,..,.._..- Right Suite®Universa1201919.020 RSU16877 Page 1 AC -, ...e 1449E RHG-N17409 BelleairAre 1449B RHG-N.rut Calc=MJ8 Front Doortces: N - wrightsoft° Right-JO Worksheet House One Stop Cooling and Heating Job: 7409 Belleair Ave 1449B RHG-N Date: 07/23/20 By. W W 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920, Fax: (407) 629 - 9307 Web: v w.OneStopCooling.com License: CAC1817652 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area House 137.0 it 8.0 it d 1422.3 ftz KIT 12.0 ft 8.0 it heat/cool 16.5 x 12.0 ft 198.0 fF Ty Construction number U-value (BtuhiW2F) Or HTM (B Area (T) or perimeter (ft) Load (Btuh) Area (fte) or perimeter (ft) Load (Btuh) Heat Cool Gross NiP/S Heat Cool Gross N/P/S Heat Cool 6 11 �G .12C-Osw ' _ - .4A5 2ov-----..__ _ .__ 12C-0s6v 4A5-2ov 11DO -4A5.2ov- ---_ 12C-0sw 4A5.2ov 11D0 12C-Osw .11D0. - - -_ - - 168 30ad i---- ----- 22A,cpm_-_- .-.--- - 0.091 .:_._ _ 0.320 0.091 0.320 0.390 _ -- -0,091 ------0.320 0.091 0.320 0.390 0.091 -- -0.390 0.032 n ._. n a a a s .- s--- w w w - ---n•- 2.27 ... _ _ =7.97 2.27 7.97 9.71 2.27 ------ 7.97 2.27 7.97 9.71 -- 2.34 :_---'8.60 2.34 16.13 7.82 2.34 .---_ ._8.73 2.34 22.64 11.99 - 264 . ---- -15 132 30 20 404 ^-_15 _ 2490- _- -- - -0 82 14 20 -- . 389 . _ . _ 13 233 0 18 286 ,.--- -]B __ -__._ 120 186 239 195 - -- 881 ..,_ _120 528 359 174 - 648 -- 174 1133 -- -- 129 192 484 157 ------ - 912 ._ -._ 131 546 1019 214 - 413 - - -140 2469 _ - _ 0 0 0 0 - - --- 96 ----_-__ 0 0 0 0 - 0 -------0 - --- - --- t) 0 0 0 -- - - - 96 : -. ----0 0 0 0 - - 0 - - - 0 198 ' _ _ 12 ----- _0. 0 0 0 -_ --- - 218 --.-----0..-- 0 0 _o 0 - -----Q 158 - ----0 0 0 0 - - 225 --- 0 0 0 0 0 ---- -- Q 344 W W, ! __G W 296 45 18 R 2.27 -9.71. 0.80 1.44 _.-. 7.82 1.74 304 . _._ 18 1422 D C --- ,F-_----- -- - _ _-- _ 1.180 - _. c--- -- 29.38.,.____0.00 ---. 1422 _1422137 _ _ -4025 , 0 ^ _ _198 - _ _ 19B _ 353 .-- -- ---- _0. 6 c)AED excursion 256 -44 Envelope losstgain 9345 7644 728 525 12 a) Infiltration b) Room ventilation 1609 0 554 0 141 0 48 0 13 Internal gains: Occupants @ 230 Appliances(other 5 1150 3400 0 0 1200 Subtotal (lines6 to 13) 10954 12748 869 1774 14 15 Less extemal load Lesstransfer Redistribution Subtotal Ductloads 12% 21% 0 0 0 10954 1296 0 0 0 12748 2698 121/o 21% 0 0 123 992 117 0 0 227 2001 424 Total room load Airrequired (dm) 12250 0 15446 740 1109 0 2425 116 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. -ri- wrigF�tsofft� 2021-Jan-2509A6:17 . P. • ...... Right -Suite@ Universal2019 19.0.20 RSU16877 Page 1 e 1449B RHG-M7409 BelleairAie 1449B RHG-N.rut Calc= W8 Front Doorfaces: N wrightsoft' Right-M Worksheet Job: House Date: One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: wmv.OneSlopCooling.com License: CAC1817652 7409 Belleair Ave 1449E RHIG-N 07/23/20 WW 1 2 3 4 5 Room name E)posed wall Room height Room dimensions Room area BED 4 29.5 It 8.0 ft heaUcool 1.0 x 145.5 ft 145.5 T MBED 27.0 ft 8.0 ft heaUcool 14.5 x 12.5 it 181.3 ftz Ty Construction number U-value (BluhAt;°F) Or HTM (Btuh/W) Area (M or perimeter (ft) Load (Bhuh) Area (fte) or perimeter (ft) Load (Btuh) Heat Cod Gross NIPS Heat Cool Gross NIPS Heat Cod 6 11 W, _L-G IWI ^- t� !--_p_ W W RR C 12C=0sw :9A6_2ov"__ _ -- 12C-0sw 4A5-20v 11 DO - _ - _ 12C-Osw 4A5 2ov�- _ _ - _ 12C-0sw 4A5-2ov 11DO 12C-Osw 16B-30ad . - 0.091 -- 0.320.-n 0.091 0.320 _ _ 0.390 0.091 0.320 0.091 0.320 0.390 0.091 _0.390 0.032 n a a a - s s_ w w w -n_- - 2.27 - -7.97 2.27 7.97 9.71 - 2.27 _ _7.97 2.27 7.97 9.71 _ -- 2.27 9.71. 0.80 ' 2.34 --- -8.60. 2.34 16:13 7.82 - - 2.34 -_ -8.73 2.34 22.64 11.99 .-.--- 1.44 ----_7.82 1.74 -- -- 28 - - -0 96 30 0 ' - 112 _ 0 0 0 0 0 ---- - 146 . - - . 28 -0 66 14 0 , -- '' 112 _ --- 0 0 0 0 - _- - 0 - 0 146 - - - 63 - -= 0 150 239 0 - - 254 --- 0 0 0 0 --- -- 0 .--- -0 116 '- ---: - -66 -- --0 155 484 0 - - 262 -_ T _0 0 0 - - - 0 0 ---- ----0 __ 253 - 106 - 0 0 0 0 + �- 0 _ -- 0 116 15 0 -- -- - 0 - ---00- 181 100 0 0 0 - _ _ --0--- 0 •-- -"___0 101 0 0 -- - 0 181 ---27 -- - -0 0 0 _ 0 0 Q 229 120 0 0 144 0 0 - - 0 0 _ -- -'__0. 237 340 - - --0 0 _ 315 -' -- -F: _ 22Acpm__ _-_1.]BO T _. ".29.38 __- 0.00 _ - 146 _ ^ 30 __ _ _867 _- _,0 ---- _ 793_ 0. 6 c)AED excursion -38 142 Envelope losstgain 1689 1181 1513 1267 12 a) Infiltration 346 119 317 109 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 2 460 Applianceslother 0 0 Subtotal (lines 6 to 13) 2035 ' 1531 1830 1836 Less exhemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 308 360 0 0 14 Subtotal 2342 1891 1830 1836 15 Ductloads 12% 21% 277 400 12% 21% 216 389 Total room load 2620 2291 2046 2225 Air required (dm) 1 0 110 0 107 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -*- wrigtitsoft- 2021-Jan-25 09A6:17 . P. -•�• - -men Right Suile@Universal2019 19.0.20 RSU16877 Page t e 1449B RHG-M7409 BelleairPue 1449B RHG-N.rut Calc= MJ8 Front Doorfaces: N A i wrightsoft° Right-J® Worksheet House One Stop Cooling and Heating Job: 7409 Belleair Ave 1449B RHG-N Date: 07/23/20 By. W W 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: vhvwvOneStopCooling.com License: CAC1817652 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area 0 ft 8.0 ft heatbool 3.5 x 3.5 ft 12.3 W MBA 6.0 ft 8.0 ft heaVcool 14.5 x 6.0 ft 87.0 ft2 Ty Construction number U-value (BtuhAF--'F) Or HTM (BtuhAn Area (ftz) or perimeter (ft) Load (Biuh) Area (fV) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W, -.- W _ W - - R - C 12C-Osw - 465,2ov____ _ _ 12C-Osw 4A5-2ov 11DO 12C-Os-w - - 4A5-2ov---- - 12C-Osw 4A5-2ov 11DO - -- - -. 12C-Osw 11D0-- -- - -' 1613-30ad 0.091 -___0.320n 0.091 0.320 0.390 - -- 0 091 -__ _0320 0.091 0.320 --- 0.390 0.091 - 0.390. 0.032 n a a a , s _ _s_ w w w - -0 _227 _ _7.97 2.27 7.97 9.71 227 -_--7.97_ 2.27 7.97 9.71 - 227 -- 9.7_1. 0.80 - -2.34 8.60_ 2:34 16.13 7.82 -�. 2.34 --- 8.7.3 2.34 22.64 11.99 1.q4 __�.7...82 1.74 -- 0 -__-0 0 0 0 --0 _ - ---0 0 0 0 __.-----0 _�_-_0 12 - - 0_0 ___0._ 0 0 0 _ 0 --:_0 0 0 0 ---;- - 0 .- -- 12 _- 0 0 0 0 - 0 - - -_ 0 0 0 0 •-- --- p - 0 10 .__ _ 0 __ `-0 0 0 0 - - - - 0 -----0 0 0 0 -- -•-- -0-- - - -0 21 __.. _48 ___0 0 0 0 --0 - ._ - -0 0 0 0 -._0 - - � 87 _ 48 _ 0 0 0 - 0 . - -_---Q 0 0 0 -----0 -- - --0 87 - - 109 0 0 0 0 _--__0 0 0 0 ---- - 0 - -- .-0 69 112 _ 0 0 0 . _ 0 .- --_0 0 0 0 -- - 0 - ---0 151 F_---_ . 22A[pm___-----_._ -_--29.38 •..-_0.00 __-12 _ .._ . 0. -�- _-- 0 _-- -----0 ---. 87 __..__.. _._6 = ..- 176,'--_ 6 c)AED excursion -1 -7 Envelope loWgain 10 21 354 257 12 a) Infiltration b) Room ventilation 0 0 0 0 70 0 24 0 13 Interned gains. Occupants@ 230 Appliances/other 0 0 01 0 10 0 Subtotal (lines 6 to 13) 10 21 425 281 14 15 Less e)demal load Lesstransfer Redistribution Subtotal Ductloads 12% 21% 0 0 -10 0 0 0 0 -21 0 0 12% 21% 0 0 2 427 51 0 0 86 367 78 Total room load Airrequired (clm) 1 0 0 0 0 478 0 445 21 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. �}� wrigt�tsoft- ��-M•�---•^•-��•� Right-Suite®Universal 201919.0.20 RSU16877 2021-Jan-2509A6:17 Page 3 e 1449B RHG-M7409 Belleair Ave 14498 RHG-N.rut Catc=MJ8 Front Door faces: N wrightsoft° Right-J® Worksheet House One Stop Cooling and Heating Job: 7409 Belleair Ave 1449B RHG-N Date: 07/23/20 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: wmv.OneStopCooling.com License: CAC1817652 WW 1 Room name MWIIC LAUN 2 Eposed wall 4.5 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 4.5 x 9.0 ft 40.5 T 6.0 x 3.0 ft 18.0 f 2 Ty Construction number U-value (Btuh/R;°F) Or HTM (Btu Area (ft0 or perimeter (ft) Load (Btuh) Area (ft2) I or perimeter (ft) Load (Stuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 IW - `(i 12C-Osw -- -- '4A52ov-- :- - -_: 12C-0sw 0.091 _. __ ._..0.320 0.091 " n -n_ a 2.21 --.7.97_.-- 2.27 --2.34 --8.60 2.34 - - p .. _- ----0 0 - - p -----° - -0 0 - 0 --_ - --0 0 - - 6 =-- -- -0 0 - --0 ----:---_0 0 . - - .- 6 -- -- ---0 0 - - -0 -- ---- 0-: 0 - b - ---_-0 0 W 11 4A5-2ov 11DO 0.320 0.390 a a 7.97 9.71 16.13 7.82 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - -- W -- --�- - 12C-Osw ' 4A5-2ov_--_-•-- -- ---- - 0.091 -----0.320 - s .-s_ - -. 2.27 ._.- 7.97 - -- 2.34 __ 8.73 -- - - - 0, _._ ___ -0 - -- -- _ 0 -_- -0-- - - -- 0 -_-- -- 0 -------- - - 0 . -- --0 - - - 0 ---.:.----0 -- - _ 0 _-- -- __0 - - - 0 W 12C-0sw 0.091 w 2.27 2.34 36 36 82 84 0 0 0 0 4A5-2ov 11DO 12C-Osw --+- -- 11D0-- ---_.- -- 1613-30ad 0.320 0.390 --- 0.091 --0.3.90 0.032 w _ _w_ -n.- 7.97 -_ 9.71 2.27 ----9.7_1----7.82- 0.80 22.64 11.99 1.44 1.74 0 0 --- 0 -0 41 0 0 - - 0 _ -0 41 0 - --- 0 0 0 -32 0 -- - 0 0 =-0- 70 0 - 0 0 - •---0 18 0 - - - 0 0 - --_0 18 0 -----0 0 -=_-----0 14 0 - - -- 0 0 -0 31 - - - C _.1.180 -._..---29.38,-- ---- _0.00_ __._41--------5___-.132 _ 0 --.,__.18-- _--0__._•-0--_.0_ 6 c)AED exarsion -4 -13 Envelope loss/gain 246 151 14 19 12 a) Infiltration 53 18 0 0 b) Room ventilation 0 0 0 0 13 Intemalgains: Occupants@ 230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13) 299 169 14 519 Less e)demalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 -14 -519 14 Subtotal 299 169 0 0 15 Dudloads 112% 21% 35 36 12% 21% 0 0 Total room load 334 204 0 0 Airrequired (cIfm) 0 10 0 0 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed - wrightsoft^ 2021-Jan-25 09A6:17 M ^-^-- Right -Suite® Universal201919.0.20RS016877 Page ...e 1449B RHG-N17409 BelleairAre 1449E RHG-N.rut Calc= W8 FrontDoorfaces: N wrightsoft° Right-JO Worksheet House One Stop Cooling and Heating Job: 7409 Belleair Ave 1449E RHG-N Date: 07/23/20 By- WIN 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BA2 0 ft 8.0 ft heat/cool 6.0 x 9.0 ft 54.0 fl= BED 2 11.0 ft 8.0 ft heaVcool 1.0 x 135.0 ft 135.0 fly Ty Construction number U-value (BtuhAf--"F) Or HTM (Btu Area (fl) or perimeter (ft) Load (B1uh) Area (fF) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 11 W 12C-O- - sw_4AS2ov.0.320 12C-Osw 4A5-2ov 11DO 12C-Osw 12C-Osw 4A5-2ov 11DO 12C-Os6v P- 11DO--___.---.--- 16B-30ad - 0 0 0.091 0.320 0.390 0.091 ---.--_ Q.320 0.091 0.320 0.390 - 0.091 ---0.390.-.:n---- 0.032 n91 - n- a a a s ,--s_ w w w "-- - 2.21 -.7.97-- 2.27 7.97 9.71 2.9 __6.60.-... 2.34 16.13 7.82 2.34 ---8.73 2.34 22.64 11.99 `- 1.44 7.82 1.74 0 0 0 0 0 0. ----- a 0 0 0 - -0 1--_..1----0 54 O---0 - _ 0 0 0 0 0 --- --- 0 0 0 0 - - 0 .0._ 54 __._0 0 0 0 0 ---- ----0 0 0 0 : - - 0 -0. 43 0 _ 0 0 0 0 0 - -----0 0 0 0 --- 0 ----0.- 94 . 88 _ __ 15- 0 0 0 0 -- ----0 0 0 0 - -- 88 0._ 135 ` - 73 - _ 0 0 0 0 0 .- ------ 0 0 0 0 88 - _--0 135 . 165 _ _ -_120 0 0 0 0 ---- -0 0 0 0 - 199 ----0 108 171 __- - 129 0 0 0 0 ---=---0. 0 0 0 -'-127 - ---0. 234 _ W �j 2.27 ----7..97_ 2.27 7.97 9.71 -j 2.27 --9.71..--"- 0.80 W _ D- C -- F- - -----., m - -- -._ 1.186 -- --_ ---- . _29.36 - 0.00 --- - - - -54 0 - - 0 - --0 135 .---- 11 ._.. - -323.. - -- 0 6 c)AED exarsion -2 -22 Ernelopeloss(gain 43 91 915 639 12 a) Infiltration b) Room ventilation 0 0 0 0 129 0 44 0 13 Internal gains: Occupants@ 230 Applianoes/other 0 0 01 1 230 0 Subtotal (lines 6 to 13) 43 91 1044 913 14 15 Less eABmal load Lesstransfer Redistribution Subtotal Dudloads 1 12% 21% 0 0 169 212 25 0 0 368 459 97 12% 21% 0 0 100 1144 135 0 0 124 1037 219 Total room load Airrequired (dm) 237 0 557 27 1280 0 1256 60 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wr-htsoRight-Suite®Uniersal201919.0.20RSU16877 Page 2021-Jan-25 09:46:17 ' CA ..e 1449B RHG-N17409 BelleairAre 1449B RHG-N.rut Calc= MJ8 FrontDoorfaces: N - wrightsoft° Right-J® Worksheet House One Stop Cooling and Heating Job: 7409 Belleair Ave 1449B RHG-N Date: 07/23/20 WW 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vwvw.OneStopCooling.com License: CAC7817652 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BED 3 10.5 It 8.0 ft heat/cool 1.0 x 136.5 It 136.5 fF FOY 4.5 ft 8.0 ft heatl000l 1.0 x 139.8 ft 139.8 fF Ty Construction number U-value (Btuh)W-°F) Or HTM (Btu Area (fF) or perimeter (ft) Load (Btirh) Area (fF) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 11 W -- 126-09w : 4A572ov-._ _-°---- 12C-0sw 4A5-2ov 11DO - . _- ... 12C-0sw 4A5.2oy_- 12C-0sw 4A5.2ov 11DO .. -_ 11D0-_---_-�__ 16B-30ad 0.091 -------0.320. 0.091 0.320 0.390 - __---- 0.091 ---0.320 0.091 0.320 -0.390 _,�0.39D 0.032 - ri - ---n- a a a ---- s _-s- w w w _n _ 2.27 =-7.97 2.27 7.97 9.71 - - - 2.27 ---7.97 2.27 7.97 9.71 2.27 . _9.71..___7.82 0.80 - f3-4 ----8.60 2.34 16.13 7.82 --- -�---- - 2.34 .____ 8.73 2.34 22.64 11.99 `.44 1 1.74 - - - 0 .----•- ----0 0 0 0 v. _ 84 _-.__15 0 0 0 - ` - ._ -0 137 = - : -0 - -_ -0 0 0 .- _ - . - 0 69 -- 13 0 0 0 -_. -- _0 ---0 137 - - --0 ----_ -- 0 0 0 0 .. p ,--. _ -0 0 0 0 0 - - -_--0 36 0 -- - -- 20 0 ..__ =_0 0 0 _ 0 - 216 140 0 ----- --0 16 0 20 _ - --- 0 r__--. 0 0 0 0 198 140 0 ------- -_ 0. 36 0 195 -- ---- - - 0 __0 0 0 0 -- -- 449 111 0 _ 37 0 157 - - --- 0 _ �-0. 0 0 0 -- 286 243 W D -_ WW,, !__G -- - -- 156 -_- 120 0 0 0_ 0 109 _ - -- - 162 131 0 0 0 - - 0 W Ec� D .L-D, C 237 F.- ---.22A-cpm---- .-------_•-1.180 -__29.38---0.00 _----137-------_11,----- -309.__-- 0.---- --140------5-_---132,!_._-0 6 c)AED excursion -19 -33 Envelope losstgain 693 511 1097 829 12 a) Infiltration b) Room ventilation 123 0 42 0 53 0 18 0 13 Intemalgains: Occupants@ 230 Appliances/other 1 230 300 0 0 500 Subtotal (lines 6 to 13) 816 1083 1150 1348 14 15 Less exdemalload Lesstransfer Redistribution Subtotal Ductloads 1 12% 21% 0 0 468 1284 152 0 0 548 1632 345 12% 21% 0 0 -1150 0 0 0 0 -1348 0 0 Total room load Air required (dm) 1436 0 1977 95 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. !�t- wrigtitsoft� �• • - •� ��mr� R ghE2021-Jan-2509A6:17 Suite®Universa1201919.0.20 RSU16877 Page 6 e 1449B RHG-M7409 BelleairAre 1449B RHG-N.rut Calc= MA Front Door faces: N -�- wrightsoft° Right-JO Worksheet House One Stop Cooling and Heating Job: 7409 Belleair Ave 1449B RHG-N Date: 07/23/20 By. WIN 7225 Sandsoove Court, W nter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: v wvOneStopCooling.com License: CAC1817652 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area LIV 32.0 ft 8.0 It heaUcool 1.0 x 274.5 It 274.5 W Ty Construction number U-value (Stuh/W--°F) Or HTM (B Area (T) or perimeter (ft) ' Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cod 6 11 W 12C=0sw 4A572ov - -' -- 12C-Osw 4A5-2ov 11 DO 12C-Osw. -- _---� 4, 5.2ov_ _�_- 12C-Osw 4A5.2ov 11DO 12C-Osw - 1613.30ad O.091 ------0.320 0.091 0.320 0.390 --- 0,091 0.320 0.091 0.320 0.390 -- 0.091 0.032 - � - n a a a S'- - s-. w w w ' - -2.27 _7.97 < 7.97 2.27 7.97 9.71 2.27 ---_7.97 2.27 7.97 9.71 -- -2.27 0.80 - 2.34 8.60 2.34 16.13 7.82 -_ 2.34 --8.73 2.34 22.64 11.99 1.44 1.74 - _ -0 .-- - -- 0 0 0 0 - 112 -- -----0 144 30 18 ..- .- . - __0 0 0 0 - 112 -------� 96 0 18 -- 0 0 0 0 0 0 0 - - ------ - -- - -- - - --- -- --- -- ----- W E �j � �-(� _ _ - 254 ---- a 218 239 174 - - 262 - -_._0 225 679 214 - --- ..-- --- - -- -. _- ------ -_ - IW G E- �D -0 275 -- -- 0' 275 0 219 - - 0 477 C F_ __ 22A cpm'- -•__--_-- - -----_1.180 �_ .. _29.38 - _0.00 -...--.,,275 _- -, 32 . 940-:- 6 c)AED exarsion 296 Envelopeloss/gain 2043 2154 12 a) Infiltration b) Room ventilation 376 0 129 0 13 Internal gains Occupants@ 230 Appliances/other 0 0 900 Subtotal (lines 6 to 13) 2419 3183 14 15 1 Less ex8emalload Lesstransfer Redistribution Subtotal Durtloads 12% 21% 0 0 5 2424 287 0 0 173 3356 710 Total room load Air required (dm) 2710 0 4066 195 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. -r- VWr7gF�tsoft� 2021-Jan-2509A6:17 .�P. •^•�•�-�•-^^^--•^�� Right-Suite®Universal 201919.0.20 RSU16877 Page 7 e 1449B RHG-M7409 BelleairAre 1449B RHG-N.rut Calc= MA Front Doorfaces: N Static Pressure and Friction Rate Job: 7409 BelleairAve 1449E R.. wrightsoft0 Date: 07/23/20 House W. vwu One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: vmw..OneStopCooling.com License: CPC1817652 For. Wade Jumey Homes FL AvailablePressure Heating Cooling (in H2O) (in H2O) External static pressure 0 0.50 Pressure losses Coil 0 0 Heatexchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure -0.2 0.34 Total• Supply Return (ft) (ft) Measured length of run -out 18 0 Measured length of trunk 8 0 Equivalent length of fittings 105 0 Total length 131 0 Total effective length 131 Friction Heating Cooling (in/100ft) (in/10011) Supply Ducts -0.122 < 0.06 0.260 > 0.18 Return Ducts -0.122 < 0.06 0.260 > 0.18 Fitting Equivalent LengthDetails Supply 11A=20,4X=35, 11 G=5, 11 G=5, 1A=35, 11 G=5: TotalEL=1 05 Return TotalEL=0 W rightsaft- 2021-Jan-25 09:46:18 Right -Suite® Universal 2019 19.0.20 RSU16877 Page 1 e 1449B RHG-M7409 Belleairfve 14498 RHG-N.rut Calc=W8 FrontDocrfaces: N - wrightsofto Duct System Summary House One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: vwvw.OneStopCooling.00m License: CAC1817652 For. Wade Jumey Homes FL Job: 7409 BeIIeair Ave 1449B R.. Date: 07/23/20 ww Heating Cooling External static pressure 0 in H2O 0.50 in H2O Pressure losses 0.16 in H2O 0.16 in H2O Available static pressure -0.2 in H2O 0.34 in H2O Supply / return available pressure -0.080 /-0.080 in H2O 0.170 / 0.170 in H2O Lowest fricdion rate -0.12 in/100ft 0.260 in/100ft Actual airflow 0 cfm 740 cfm Total effective length (TEL) 131 ft i Name Design (Btuh) Htg (dm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mat! Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BA2 c 557 0 27 0.321 4.0 Ox 0 VIFx 10.8 95.0 st2 BED2 c 1256 0 60 0.284 6.0 Ox0 VIFx 24.7 95.0 st1 BED3 c 1977 0 95 0.294 6.0 Ox0 VIFx 15.7 100.0 st2 BED4 c 2291 0 110 0.260 6.0 Ox0 VIFx 26.0 105.0 st2 KIT c 2425 0 116 0.309 6.0 Ox0 VIFx 15.0 95.0 st2 LIV c 4066 0 195 0.277 7.0 Ox0 VIFx 27.5 95.0 st1 MBA c 445 0 21 0.306 4.0 Ox0 VIFx 16.1 95.0 st1 MBED c 2225 0 107 0.303 6.0 Ox0 VIFx 17.1 95.0 st1 MWIC c 204 0 10 0.302 4.0 Ox0 VIFx 17.7 95.0 st1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (dm) (dim) FIR (fpm) (in) (in) Material Trunk st1 PeakAVF 0 393 0.277 500 12,0 0 x 0 VinlFlx st2 PeakAVF 0 347 0.260 637 10.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 Ox0 0 740 0 0 0 0 Ox 0 VIFx * wr ghtsoft'° yAA�/��, , , Right Suite® Universal 201919.020RSU76877 AC0,....a 1449B RHG-NV409 Belleair Aie 1449B RHG-N.rut Calc= MJ8 Front Doorfaces: N 2021-Jan-25 09.,46:18 Page 1 Level 1 LIV MWIC MBED 8x4 10 cfm 10x6 10x8 4 SRB 2 107 cfm 195 cfm 24 x 4 7" 8x4 21 cfm p 4" Bath Duct to Roof 4" Dryer Duct to Roof 19T . W/Fan Cap wlDryer Vent Box LAU N Broan 50CFM BA 2 6 " MBA 1 I6 p cfg m 12 " BED 2 4" Bath Duct to Roof W/Fan F Broan 50CFM g 7 cfm 101, gp0.m 24x14 RA 1. SRB 1 740 cfm T 'pig 95 cfm 6" 6, NO24x4 2.0 ton W/5KW @240V 1 PH AIC-1: 2.0 TON 14X14 Plen 14.0 SEER H.P. BED 3 24 x 4 ON METAL STAND AC Slab By Builder 2' From Wall 24x4 10x6 110 cfm FOY 4 GAR Job #: 7409 Belleair Ave 1449B RHG-N Scale: 1 : 34 Performed by WW for: One Stop Cooling and Heating Page WadeJumeyHomes 7225 Sandscove Court Right•Suite®uni%ersd2019 Winter Park, FL 32792 191-Ja RSU16877 FL Phone: 407 629 - 6920 Fax: 407 629 - 9307 202airAve 14 9:B RH i ) ...409 BelleairAve 14498 RHGN.rut www.OneStopCooling.com