MOUNTAIN REQUIREMENTS
1. SUBSCRIPT AT STROBES AND HORN/STROBES DENOTES CANDELA PER NF A i2 2016 AND UL 1971. 2. ALL > , & INITIATINGDEVICES,ABE • s i POINT OF ANNUNCIATION PANEL TO SUPERVISE THE ANNUNCIATOR PANEL ALL CIRCUITS AND INITIAT:NG DEVICES). 4. ALL DEVICES IN THE FIRE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED TO MANUFACTURERS SPECIFICATION. 5. AREAS; O•E THAN ONE VISUAL NOTIFICATIONAPPLIANCE ; OTHER& FIELDTHE SAME OF VIEW SHALLBE ' i ! 6. SUBSCRIPT SHOWN NEXT TO INITIATING DEVICES DENOTES THAT DEVICE'S ADDRESS ON THE SIGNALING LINE CIRCUIT (SLC). 7. FOR ALL SHIELDED CABLES USED IN THE INSTALLATION OF THE SYSTEITI, THE SHIELDS MUST BE SPLICED THROUGH FROM CABLE TO CABLE AND BE I NSU LATE D/ISCILATED FROM GROUND AND CLEAR OF GROUN • ; y ; • •; f • • ; iI LT r !CODE PERMITS. MINIMUM RACEWAY 3/4". 40% CONDUIT FILL MAXIMUM. r !. 101kyAlloato A •A ; A �sX • # •� �; •l 16. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN T OF A/C DIFFUSERS, KITCHEN OR BATHROOM DOORS. OTHERWISE17. CEILING MOUNTED DEVICES SHALL BE LOCATED ATA HEIGHT OF 10 I-oll +/ ON SMOOTH FLAT CEILIN-0 UNLESS BATTERY.18. THIS IS A BATTERY BACKUP SYSTEM, WITH 24 HOURS OF BACKUP& 5 MINUTES ALARM. SHOULD LOSS OF NORMAL 120 VAC OPERATING POWER OCCUR., THE FACP WILL AUTOMATICALLY TRANSFER TO STANDBY 19. FIRE ALARM PANEL& ANY ASSOCIATED FIRE ALARM TRANSPONDERS SHALL BE FED BY A 120 VAC, SINGLE PHASE, 20AMP., DEDICATED BREAKER. NOTED.0`0. RACKS, SHELVES AND EQUIPMENT ARE ALL LOWER THAN 80" ABOVE FINISHED FLOOR UNLESS OTHERWISE • • PATHWAY ;; t ! LEVEL 0 PATHWAYS SHALLREQUIRED ! HAVA ANY PROVISIONS • PATHWAY • i CERTIFICATE30. THE SOUND LEVEL WILL BEAT LEAST 15DBA ABOVE THE EQUIVALENT SOUND LEVEL OF 5DBA ABOVE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS MEASURED 5 FEET ABOVE THE FLOOR IN THE OCCUPIES AREA, INCLUDING RESTROOMS, WALK-IN COOLERS AND STORAGE AREAS. THE CONTRACTOR IS REQUIRED TO CERTIFY THE DBA LEVEL WITH AN APPROVED DBA METER PRIOR TO THE ISSUANCE OF THE OF OCCUPANCY. 31. ALL INFORMATION WILL BE ON SITE WHEN THE SAINT LUCIE COUNTY FIRE/RESCUE DEPARTMENT IS REQUE�JED TO WITNESS THE ACCEPTANCE 32. THE PLANS MUST INDICATE THE RECORDS OF COMPLETION WILL BE PREPARED AND A COPY ilROVIDED TO THE OWNER AND THE SAINT LUCIE COUNTY FIRE RESCUE DEPARTMENT. UPDATED UL CENTpAL STATION • 1 ST. LUCIE COUNTY PLAN REVIEW A 4 BLDG: DATE' ELE DATE: PLUMB: DATE: _"_,_ MECH: DATE: MOUNTING REQUIREMENTS N.F.P.A. 72 2016 ED. FIGURE A.17.3.2.1 NOTE MEAWREMENTS SROWN AW TO E CLOSEST OF THE DMICTOR 7WALL ED HERE x a � TOP OF DETECTOR OUNTED ACCEPTED SMOKE DETECTOR HERE 24" OR MORE SIDE WALL 110cd STROBE CEILING 00 Z zwNc6 V r,4 to ® a oa i z x w CO ao :n av ad m0r'0 o. oho le In aZ TED N.F.P.A, 72 2016 ED. T SECTION A.17.7.4.1 �! 1 3' MIN. zo X w av ra <UNxrr ed m0<— w Li z SYNCHRONIZE MORE THAN TWO APPLIANCES IN ANY FIELD OF v VIEW N.F.P.A. 72 2016 ED. SECTION 18.5.5.5.7 m ww o"— 4in e®aiw 0Nr z 'caw - - a)CDz�� aLu w C5 I— z MOUNTING HEIGHT 247 OR LESS OF CEILING 177 ad WEN IS GREATER THAN 24" TO THE CETUNG 110ed AS NFPA 72 ED. 2016 { THE BIND � SLEMNG IS AT LEAST SEG. 18.5.5.7 15 d9A ABOVE AWRALE T SOM LEVEL OR 75 CB0 MEAI AT hE KLOW. 16' MAX STROBE — PILLOW tlHMW IS (WATER PER WPA 72 18.4.5.1 (11N5 ED.) AUM E APPLIANCE PRO- VM N AREAS FOR SLEVIN WALL PRO- LTUCE A LOW MUOICY (520 1k)µAN PER IWPA T&I&4.5.3 (=6 ED.) SLEEPING ROOM 4" A/C SUPPLY �t DIFFUSER ACCEPTED HERE AUDIO / VISUAL AND VISUAL —ONLY DEVICES NEVER HERE—j DOOR WIDTH LESS 3" 0 MAGNETIC DOOR HOLDER FIRE PHONE JACK SHALL BE NO LESS THAN 36" AND NOT MORE THAN 66" ABOVE FLOOR LEVEL WTH {YEAR ACCESS AT LEAST 30 in. NFPA 72 (ED. 2016) SEC. 25.35.1.17 N.F.P.A. 72 2016 ED_''. FIGURE A.17.3.1.3.1 NOTE: MEASURMENTS SHOW AM TO E CLOSEST OF THE `a x 4 r WALL MOUNTED HEAT DETECTO FINISHED WALL MANUAL PULL STATION SIDE WALL '" -= WITHIN 5' ' 2 r'' FROM D001 ? ¢ O as PER NFPA 72 2016 C,4 b N �`EI- 17.14.8.4 a u.P 11 20 l St. Lucie -our11 r ALARM SYMBOLS Q MODEL SYMBOL DESCRIPTION i MOUNTING INFORMATION L STATION © STROBE MOUNTEDFIRE i. ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR PANEL DIGITAL ALARM COMMUNICATOR TRANSMITTER 1 DUCT SMOKE DETECTOR SMOKE DETECTOR ar... _..�... MANUAL STATION HORN / STROBE — WALL MOUNTED ra. ©�•�:WALL MOUNTED sr.... WATER FLOW SWITCH SWITCHVALVE TAMPER m 4T 3.�. ..�.' -.k i J e 0- 0 83 Stag%=r ,. _ r ��fgitatl�3igned �S„ �• �effre'y P. Collins,PE >:-j•``';= 592i 8fFTwtc3at�.k`- i .'S•r4�kyj�i xay..: a ai tr00e xiie""t _Z 0- 0 LU i] Q on � IL U z lu j Lu 2 C O W � Z O LLI t— <t N O eC} tV � U r N ®M E 9— �Q o* � ZLi:It ari W 9 cn W � ' U E W 0- ®y < a) ® v�cr? _ LL m 7- AVI N Q Lz n (D o > <CM�a uNCN � ci ci®RCN L- C'; C•i U) ►� x C7�u_ Co THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF ADT COMMERCIAL, IT IS NOT TO BE USED OR DUPLICATED BY ANYONE WITHOUT THE WRITTEN CONSENT OF ADT COMMERCIAL. IF ANY DOCUMENT PREPARED BY ADT COMMERCIAL IS ALTERED IN ANY MANNER BY OWNER, ITS AGENTS OR BY ANY THIRD PARTY IF CONSTRUCTION IS NOT IN ACCORDANCE WITH UNALTERED DOCUMENTS PREPARED BY ADT COMMERCIAL THEN IT IS UNDERSTOOD THAT ADT COMMERCIAL HAS NO LIABILITY IN WHOLE OR IN PART, RELATED TO THE PROJECT AND THAT THE OWNER AND ITS AGENTS INDEMNIFY AND HOLDS HARMLESS ADT COMMERCIAL FOR ANY AND ALL ACTS RELATED TO THE PROJECT. THIS CONCEPT DRAWING IS FOR INFORMATION ONLY TO POTENTIAL SYSTEM ARRANGEMENT. CONTRACTOR SHALL FIELD VERIFY ALL INFORMATION CONTAINED ON THESE DRAWINGS AND IS RESPONSIBLE FOR DESIGN AND INSTALLATION OF THE SYSTEM IN ACCORDANCE WITH THE SPECIFICATIONS. TO THE BEST OF ADT COMMERCIAL'S KNOWLEDGE THE DRAWINGS AND N SPECIFICATIONS SUBMITTED HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PREVISIONS OF THE APPLICABLE N.F.P.A. CODES IN EFFECT AT DATE SHOWN. LLJ �IUJJ Z LL_ Lu Lu U wJ 2 CJ ce- i V) °- Ln Li_ co L r) 00 JURISDICTION: SAINT LUCIE COUNTY DESIGNED BY: AD DATE: 07.20.2021 PROJECT NO: 280803257 SCALE: 3/16"= 1'-0" TITLE: FIRE ALARM PLAN SHEET: FA-01 FlMUTe ALarMS MS-905OUD Battery Calculation by Honeywell Secondary Power Source Requirements Device Type St Qty ndby Current Current Draw (amps) Secondary Alarm Current (amps) Total Qty Current Draw Total I ,Main Circuit Board F-1 I V re r ZZT_ �_P 9t 0.000300 0.000300 0.000270 0.000200 1111111,1110T, "If M11 611111110�� ■_ ■_ / 111/11 i I�! / 1111/1 FIMUTeAlLa"S by Honeywell — ---- - --- --- ---- MS-905OUD Battery Calculation Calculation in Total Sheet Required Standby Time • in Hours rol-fraffWE M-1 a 0.1200 Amps Required Alarm Time in Minutes Total Alarm Load 0.6400 Amps Total Current Load Multiply by the Derating Factor Total Ampere Hours Required Recommended Batteries: I BAT-1270 - 7AH Batteries I Battery Check The es can be charged by the MS-9050LID Charger. IThe batteries can be housed in the MS-19050UD Cabinet, Current Draw Check NAC#1 current is within the limitations of the circuit. NAC#2 current is within the limitations of the circuit. MS-9050UD current draw: The required output current is within the panel's limitations _8F1ML1TeAta"s MS-905OUD Circuit Detail by Honeywell NAC I Device Qty I Non -Alarm Draw] Total Qty I Alarm Draw Total 0.176000 0.880000 0.116000 0.348000 • I= I[IE= Total Alarm Load 111ORTM Ms I Device afy [ N n-Alarm Draw I Total Qty I Alarm Draw Total 0.176000 1=111 FIM z �, 75C 75C 75C 75C EXISTING DEVICES RELAY MODULE N2-07 N2-06 N2-05 N2-04 0 LO FOR MAGLOCK 0 J4 Pnwl:� �Zwl iTnnwm POWER SHUTDOWN EXISTING DEVICES EXISTING DEVICES R M M 1 "2M 13 1 M13 E FIRELITE E MS-9050UD E FDACTI FACP ------FFAApi Zi \ Jeff gsay,R,,, SO rf �8V State UJ V0 k W it yS! d F s,PE 538 of r6 f 410 15-.47:16 -04'00' 0 C� III 0 0 U) Z LU > Uj >1 o mi LU tE C) � 0 cm to C) 'tr 0 9 5; Lu (U L) Ib= (D U. U) z LL 4t C: LLJ Uj a. E E M 1D Lu CLFLR.< I w C: M a) tf Ji F7 0.� :C U_ M (!5