Loading...
HomeMy WebLinkAboutPRODUCT REVIEWSYSTEM SENSORO Indoor Selectablem Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert° Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Field -selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Horn rated at 88+.dBA at 16 volts • Rotary switch for horn tone and three volume selections • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert devices • Compatible with MDL3 sync module • Listed for ceiling or wall mounting Agency Listings SIGNALING UL F M> ME LISTED APPROVED approved 7125-1653:186 (Indoor strobes) 71 25-1 653:188 (horn strobes, 54011 (chimes, horn strobes, horns) 55512 (strobes) 3023572 MEA452-05-E chime strobes) 7135-1653:189 (horns, chimes) f r 9 V s t S r e o r The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections: SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance' circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit' Module accessory,_ shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification, appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full - wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable_. candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans, with Disabilities Act requirements for visible signaling appliances, flashing at 1 'Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be Wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hi over the strobe's entire operating voltage range. The strobe light shall, consist of a xenon flash tube and associated lens/reflector system. The horn shall have three. audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synch ronize'multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 1209F (0°C to 49°C) Humidity. Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per.second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR? Operating Voltage Range2 8 to 17.5 V (12 V nominal) or'16 to 33. V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 1.7.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12'to 18 AWG. Wall -Mount Dimensions (including lens) 5.6% x 4.7"W.x 2.5"D (142 mm L x 119 mm W. x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.31D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS) 5.7"L x 4.8"W x 0.35"D (145 mm L x 122 mm W x 9 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply,and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard 18 123 128 66 71 Candela 15/75 . 142 148 77 81. Range 30' NA NA ' 94 96 75 NA NA 158 . 153 95 NA NA 181 176 110. NA NA 202 195 115 NA NA 210, 205 High 185 NA NA 228 207 Candela 150 NA NA' 246 220 Range 117 NA NA 281 251 185 NA NA 286 258 UL-Max. Horn Current .. Sound Patter dB 8-17.5 Volts DC FWR 16-33 Volts DC FWR Temporal High 57 65 69 75 Temporal Medium. 4:4 49 ' 58 69 Temporal Low 38 44 44 48, Non -temporal High 57 56 • 69 75 . Non -temporal Medium 42 50 60 69 Non -temporal Low 41 44- 50 .50 Coded High. 57 55 69 75• Coded Medium .44 51 56 69 Coded Low 40 46 52 50 Max. Current Draw (mA DC Input RMS), 2-Wire 8-1 Z5 Volts 15 Horn 15/75 Strobe,UL ..rd 16-33 Volts 15 Candela Range (15-115 15/75 30 cd) 75 95 110 115 Temporal High 137 . ' 147 79 90 107 176 194 212 218. Temporal.Medium 132' 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 '93 1'54 179 198 207 Non-Temporal.High 141 152 91 100 116 176 201 221' ' -229 Non -Temporal Medium 133 145 75 85 102 163 - 187 207 '216 Non -Temporal Low 131 14.4 68 79 96 156 182 201 210 FWR Input' Temporal High 136 155 '88 97 112 168 190 210 218 Temporal Medium 120 152 78 88 103 160 184 202 206 Temporal Low 129 151 . 76 86 101 . 160 184 194 . 201 Non -Temporal High 142 161 103. 112 126 181 203 221 229. Non -Temporal Medium. , 134 155 85 95 110 166 189 208 216 . Non -Temporal Low 132 154 '80 90 105 161 184 202' - 211 UL Max. Current •Strobe, DC Input 16-33 Volts 135 150 117 185 FWR Input 16=33 Volts 135 150 177 185 Temporal High. 245 259 290 297 Temporal High 215 23.1 258 265 Temporal Medium 235 253 288 297 Temporal -Medium 209 224 250 '258 Temporal Low 232. 251 282 292 Temporal Low . 207 221 . 248 .256 Non -Temporal High 255 270 303 309 Non -Temporal High.- 233 248 275 281 Non -Temporal Medium ' 242 259 293_ 299 Non -Temporal Medium 219. 232 •262 .267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262. Horn Tones and Sound Output Data Morn . Morn StrobeOutput 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC, FWR- DC FWR DC FWR - DC FWR 1 Temporal 'High' 78 78 84 ' 84 '88'. 88 ,. 99. 98. 2 Temporal Medium 75 75• 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 ' 89 4 Non -Temporal High 82 82 88 88 93 92 100 100 6 Non -Temporal Medium '78 78 85 85 90 90 98 98 6 Non -Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 '92 101 101 8t Coded Medium 78 78 85 85 90 90 97. 98 9t Coded Low .. 74 75 81 81 88 85 96. 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes SpectrAlert Advance Dimensions Wall -mount horn strobes SpectrAlert Advance Ordering Information r..- .- . . Wall Horn Strobes P2R 2-Wire Horn Strobe, Standard cd, Red P2R-P 2-Wire'Horn.Strobe, Standard cd, Red, Plain P2R-SP 277re Horn Strobe, Standard cd, Red, "FUEGO" 72RH 2-Wire Horn Strobe, High cd, Red' P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain P2W 2-Wire. Horn Strobe, Standard cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White. P2WH-P 2-Wire Horn Strobe, High cd, White, Plain P4R 4-Wire Horn Strobe, Standard cd, Red P4R-P 4-Wire Horn Strobe, Standard. cd, .Red, Plain P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes SR Strobe, Standard cd, Red SR-P, Strobe, Standard cd, Red; Plain SR-SP. Strobe,_Staridard cd, Red,"'FUEGO" .. ' ModelDescription Wall Strobes (cont.). SRH _Strobe, High cd, Red SRH-P Strobe; High cd, Red, Plain SRH-SP Strobe, High cd, 'Red, "FUEGO" . SW Strobe,' Standard cd, White SW-P Strobe, Standard cd, White, Plain SWH Strobe, High cd, White SWH-P Strobe, High cd, White; Plain Horns HR Horn, Red HW Horn, White Accessories TR-HS Trim Ring, Wall, Red SBBR Indoor Surface Mount Back Box, Red SBBW Indoor Surface. Mount Back Box; White Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. o�J 1 STEM 3825 Ohio Avenue • St. Charles, IL 60174 @2014 System Sensor. �. SENSOR® Phone: 800-SENSOR2 •Fax: 630-377-6495 subjecA to I., current product information, including the latest version of this data sheet www.systemsensor.com AVDS10201.1/14