HomeMy WebLinkAboutCertification for Design Load Compliance Planning& Development Services Department
Building&Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982-(772)462-1553
Certification for Design Load Compliance
Project Name: RE-ROOF
Project Address: 787 NE PRIMA VISTA BLVD.
Permit#: Occupancy Type: A Construction Type: V
INSTRUCTIONS FOR USE:
•This certification must lie completed,signed,and sealed by the design professional of record.
•Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following:
o New Residences(single or multi-family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
*Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official.Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED:(complete all that apply)
1. DESIGN CODE: Florida Building Code 2020 7th Edition with 20 Supplements using ASCE 7-16
2.Structure Designed as(check one): X Enclosed Partially Enclosed Open
3.Risk Category: _I X II III IV Exposure Category: X B_ C_D
4.Design Wind Velocity 160 mph 124 ASD N/A LRFD End Zone Width 5 ft
5.Mean Roof Height: 20 ft Roof Pitch: N/A :12 Parapet: N/A ft
6.Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings):
10.0 10.0 10.0 27.6 27.6 N/A
Zone 1: Zone 2: Zone 3: Zone 4: Zones: Garage: -
-39.2 -51.7 -70.4 -30.0 -37.0 N/A
7.Design Loads: Floor: N/A PSF Roof/Dead: 7 PSF Roof/Live: 20 Balcony:_ N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A .PSF Fence: N/A PSF Railings: N/A PLF/CONCENTRATED
8.Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9.Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10.Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that,to the best of my knowledge and belief,the attached plans&specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St.Lucie
County-.l also certify-that structural elements depicted on these plans provide adequate resistance tolthe design
forces spec i d: —
= - Paul Welch P.E. 29945 / 5115
Print Name Cert#&Co.Cert Auth.
Paul Welch Inc.
:9/30/2021
Signature,Wit And Sea.["'
eal 1984 S.W. Biltmore St.Suite#1i14 Port St. Lucie, FL
Company Name&Address
SLCCDV Form#020-12 Revised 3/15/12(JS)
I