Loading...
HomeMy WebLinkAboutCertification for Design Load Compliance Planning& Development Services Department Building&Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982-(772)462-1553 Certification for Design Load Compliance Project Name: RE-ROOF Project Address: 787 NE PRIMA VISTA BLVD. Permit#: Occupancy Type: A Construction Type: V INSTRUCTIONS FOR USE: •This certification must lie completed,signed,and sealed by the design professional of record. •Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following: o New Residences(single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. *Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED:(complete all that apply) 1. DESIGN CODE: Florida Building Code 2020 7th Edition with 20 Supplements using ASCE 7-16 2.Structure Designed as(check one): X Enclosed Partially Enclosed Open 3.Risk Category: _I X II III IV Exposure Category: X B_ C_D 4.Design Wind Velocity 160 mph 124 ASD N/A LRFD End Zone Width 5 ft 5.Mean Roof Height: 20 ft Roof Pitch: N/A :12 Parapet: N/A ft 6.Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings): 10.0 10.0 10.0 27.6 27.6 N/A Zone 1: Zone 2: Zone 3: Zone 4: Zones: Garage: - -39.2 -51.7 -70.4 -30.0 -37.0 N/A 7.Design Loads: Floor: N/A PSF Roof/Dead: 7 PSF Roof/Live: 20 Balcony:_ N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A .PSF Fence: N/A PSF Railings: N/A PLF/CONCENTRATED 8.Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9.Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10.Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that,to the best of my knowledge and belief,the attached plans&specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St.Lucie County-.l also certify-that structural elements depicted on these plans provide adequate resistance tolthe design forces spec i d: — = - Paul Welch P.E. 29945 / 5115 Print Name Cert#&Co.Cert Auth. Paul Welch Inc. :9/30/2021 Signature,Wit And Sea.["' eal 1984 S.W. Biltmore St.Suite#1i14 Port St. Lucie, FL Company Name&Address SLCCDV Form#020-12 Revised 3/15/12(JS) I