ENGINEERING SUBMITTALS
SEPTEMBER 13, 2021
WIND LOAD CERTIFICA TION.-
CODE-FBC 2020/ASCE7--16
(FBC 7m EDITION
WIND SPEED.• 160 mph, 3 SEC. GUST
EXPOSURE, "B"
CATEGORY II
INTERNAL PRESSURE COEFF 0.18
JOB:
RE-ROOF CM
787NEPRIMA VISTA BL VD.
PORT ST. LUC19 FLORIDA
PAUL WELCH INC,
Mechanical Electrical Civil Engineering -
1984 S.W. Biltmore St Suite#114
Port Saint Lucie, FL 34984
(772)785-9888 pwelchinc@aoLcom = - : :
Paul Welch, P.E. Fla Reg No. 29945
r -
PROJECT DATA:
NAME: R&ROOF
ADDRESS: 787 NE PRIMA VISTA BLVD.
PORT ST.LUCIE,FL
SQUARE FOOTAGE:
TYPE OF CONSTRUCTION: VB
SCOPE OF WORK:
- REMOVE EXISTING ROOFING
- REPAIR/REPLACE EXISTING METAL DECK WITH 18-22GA TYPE`B"GRADE 33
STEEL DECK OVER EXISTING STEEL BAR JOISTS AT 5'O.C.MAX WITH 5/8"
PADDLE WELDS WITH WELD WASHERS OR WITH TEKS 4 FASTNERS SPACED AT
6"O.C.,SIDE LAPS SECURE W/TEKS 1 FASTNERS AT 30"O.C.MAX
- INSTALL NEW MODIFIED BITUMEN SYSTEM PER PRODUCT APPROVAL
I
NOTE:ALL CONSTRUCTION MUST COMPLY WITH THE FBC 2020,THE 2020 FLORIDA PLUMBING
CODE,THE 2020 FLORIDA MECHANICAL, AND THE NEC(NFPA 70)2017 EDITION:
ALL ADDITIONS,REPAIRS,AND ALTERATIONS MUST COMPLY WITH THE FBC 20 FOR
EXISTING BUILDINGS.
THIS IS AN ALTERATION LEVEL 1 AND MUST COMPLY WITH THE FBC 2020 FOR
EXISTING BUILDINGS CHAPTER 6 AND 7
NOTES:
-THE CONTRACTOR,SUBCONTRACTOR,SUPPLIER,ECT.SHALL VERIFY ALL DIMENSIONS,
CONDITIONS AT JOB SITE,PLANS,SPECIFICATIONS,ECT.
-STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE
ENGINEER AS CONSTRUCTION PROGRESSES.
-ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED
DIME
NSIONS.
-ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE FBC 2020.
STRUCTURAL NOTES
1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-16.
2) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF
HARDWARE IS NOT PERMITED.
3) UNLESS OTHERWISE NOTED,THE INSTALLATION OF SPECIFIED HARDWARE SHALL
CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICIES.
PAUL WELCH INC.
Mechanical Electrical Civil Engineering
1984 S.W. Biltmore St Suite #114
Port Saint Lucie, FL.34984 -
(772) 785-9888 pwelchinc@aol.com
Paul Welch, P.E. Fla Reg No. 29945
SEF ; 3 -ZQ12a
i
.'
,�
�i 9
.i
s _ 1 ..
:y - �. ..
p. �
t:
160 / 20' / EXP 0
ZONE SQ. Ff. Pos Neg
1, 1'g 10 10.0 -39.2
2 10 10.0 -51.7
3 10 1 10.0 1 -70.4
BUILDINGS h �60 ft.
:Parapet height< 3 ft.
ROOF BONE T= INTERIOR.
ROOF ZONE 'I = FIELD
R00F ZONE 2 = PERIMETER
ROOF ZONE 3 = CORNER DO Sohn
777 �<
• `.'a-u^.�a:.v+[".ww.Y+..aaiva•:`.wien:�.aawr,wo4nim.aniti'ay.:4tr_wa.cii..,�yl. i..iic'.t_1N«d.Ti:`iMM.W+mea:' aye-/p��.y
01 T
q,4
k.
fl. h
)T=cave.he ght
PAUL ,WELCH INC.
JOB: Mechanical Electrical Civil Engineering
RE-ROOF 1984 S.W. Biltmore St suite#114
787 NE PR,WA VISTA BLVD. ' - - Port Saint Lucie, FL 34984
PORT'S7*. LUCIE, FLORIDA (772) 785-9888 pweichinc@aoi.com
S E P 1 3 2021 Paul Welch, FE, Fla Reg Mo.29945
Building Department Product Approval Submittal Affidavit
Permit# — +Building Address:SEE PLAN Contractor:TBD
Opening Schedule:Swing doors,Overhead Doors,Sliding Doors, Fixed Glass,Windows&Skylights
Product Model# Manufacturer Attachment Method Building Product Design
Type,Size,Spacing,Embedment&Stiffener etc. iPressure
Design Pressure
FOR ZONES 1,11 AND 2 USE SYSTEM B(6)(SEE PAGE 19 OF
ZONE 1,11,2=
NOA#20- MODIFIED NOA#20-0723.28) 1:1.33ftsq FASTNER DENSITY
Roof 0723.28 BITUMEN CERTAINTEED FOR ZONE 3 ENHANCE FASTNERSTO 1:0.66ftsq FASTNER SEE PLAN 52.5
DENSITY ZONE 3=-105
Hurricane Panels N/A
I have reviewed the above product approval information and approve it.
Name: Paul Welch P.E. Certification Number: 29945 1 I
JOB.-
RE-ROOF Ca
767)vrPRimA YIS7'A BL vD.
F
PORrST. LUCID", FLORIDA
'0
PAUL WELCH INC.
Mechanical Eleotrical Civil Engineering
1984 S.W Biltmore St. Suite#114
Port Saint Lucie, FL 34984
SE'P (772)785-9888 pwelchinc@aot.com
3- 2021,
Paul Welch,PE Re Reg No. 29945
(4Ia1)
3 10 � 10 10 3 10
CN7 seta
(60)
v �' CM
(120)
r
Sketch Area Legend
Sub Area Description Area Fin.Area Perimeter
BAS BASE AREA 4200 4200 316
CN2 CANOPY 240 0 144
Special Features and Yard Items
Type Qty Units Year Bit
ASP2 LOW 1 12500 1970
CEMENT CURB 1 126 19,73
Current Year Values
Current Values Breakdown Current Year Exemption Value Breakdown
Building: $242,100
Land: $117,300
Just/Market $359,400
Ag Credit: $0
Save Our Homes or 10% $0
Cap:
Assessed: $359,400
Exemption(s): $0
Taxable: $359,400
Current Year Special Assessment Breakdown
Start Year AssessCode Units Description Amount
2010 9003 2.44 River Park I Street Lights $64.42
This does not necessarily represent the total Special Assessements that could be charged against this property.The total amount charged for spiecial assessments is reflected on the most
current tax statement and mt'ormation is available with the SLC Tax Collectoes Office G.
I
i
Historical Values
Year Just/Market Assessed Exemptions Taxable
2020 $359,400 $359,400 $0 1359,400
2019 $362,100 $362,100 $0 $362,100
2018 $361,100 $361,100 $0 $361,100
I
I
Permits
Number Issue Date Description Amount Fee
C1006-0244 Jul 12,2010 Roof $o $0