HomeMy WebLinkAboutNotice of Acceptance (2) MIAMI BADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525 99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy CertainTeed LLC. 20 Moores Road Malvern,PA 19355 SCOPE: . This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County.and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use )f such-product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roof Systems over Steel Decks. LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and$ollowing statement: "Miami=Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the -materials,use,andior manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. .INSPECTION:A copy of this entire NOA shall be provided to the user,by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#20-0110.10 and consists of pages 1 through 49. The submitted documentation was reviewed by Alex Tigera. I NOA No.:20-0723.28 MIAMMWEcoutQ . Expiration Date:01/02/23 Approval Date:09/17/20 i Pagel of 49 FAVE COPY I Membrane Type:. SBS Modified Deck Type 2I: Steel,Insulated Deck Description: 18-22 ga.,Type B,Grade 33 steel deck is secured at 5 ft.o.c.spans with 5/8"paddle welds with weld washers or with e T ks 4 fasteners spaced 6 o.c.Side laps are secured with Teks 1 fasteners at 30"o.c. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table: System Type B(6): Base layer of insulation mechanically fastened,top layer adhered with approved asphalt. All General and System Limitations apply. i One or more layers of any of the following insulations. . i • i' Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' ' ACFoam-II,ACFoam-III,FlintBoard ISO,F1intBoard ISO Cold;ENRGY 3,Multi-Max FA-3,H-Shield,' FlintBoardH ISO - Minimum 1.5"thick 1,2,6,7,12,20 1:1.33 ft2 Note: Base layer shall be mechanically attached with fasteners and density described."Insulation panels listed are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall tie increased maintaining.the same fastener density(See Roofing Application Standard RAS 117 for fastening details). Too Insulation Laver 'Insulation Fasteners Fastener able 3 Density/ft' FescoBoard Minimum%11 thick N/A N/A Stuctodek High Density Fiberboard Roof Insulation Minimum%2"thick N/A N/A Note: Top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20 40 lbs/160 ft'. Please refer to Roofing Application Standard RAS 117 for insulation attachment.Composite insulation boards used as a.top layer shall be installed with the polyisocyanurate face down. Base Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, Flintlastic Base.20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet, Flintglas Ply 4 or Flintglas Prernium Ply 6 adhered to the insulated substrate with approved mopping asphalt applied within the EVT range and at a rate of 20401bs./sq. Ply Sheet:, One ply of All Weather/Empire Base Sheet,.Glasbase Base Sheet,Flexiglas Base Sheet, (Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas.Premium Ply 6 adhered to-base sheet with approved mopping asphalt applied within the EVT range and at,a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base;sheet or Flintlastic Ultra Poly SMS Base Sheet torch applied to base sheet.. Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic FR-P,Flintlastic Premium. FR-P;Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved MIAM4QauE�ov�rr NOA No.:120-0723.28 Expiration Date:01/02/23 Approval Date:09/17/20 Page 19 of 49 ROOFING SYSTEM APPROVAL Category: Roofing Sub-Category: Modified Material: APP,SBS Deck Type: Steel Maximum Design Pressure: -172.5 psL TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product ' Product Dimensions Specification Description' All Weather/Empir-Base 39 3/8"x 65'10'; ASTM D 4601, Asphalt coated,fiberglass reinforced Sheet Roll weight:701bs. Type II base sheet. (2 squares) Flexiglas Base Sheet 39 3/8"x 98'9";Roll ASTM D 4601, Modified Bitumen coated fiberglass weight:901bs. Type II base sheet. (3 squares) Flintlastic Base 20 39 3/8"x 49'6";Roll ASTM D 6163, Modified Bitumen coated fiberglass weight:90 lbs. Grade S,Type I base sheet. (1.5 squares) Flintglas Ply 4 . 39 3/8"x 164'7";Roll ASTM D 2178, Fiberglass,asphalt impregnated ply weight:38 lbs. Type IV sheet. (5 squares) UL Type G1 Flintglas Premium Ply 6 39 3/8"x 1647';Roll ASTM D 2178, Fiberglass,asphalt impregnated ply weight:401bs. Type VI sheet.. (5 squares) UL Type G1 Flintlastic STA 39 3/8"x 32'10";Roll ASTM D 6222,Grade Smooth surfaced APP MI odified weight:871bs. S,Type I Bitumen membrane with non-woven (1 square) polyester mat reinforcement for torch application. Flintlastic GTA 39 3/8"x 32' 10";Roll ASTM D 6222,Grade Granule surfaced APP Modified weight: 1051bs. G,Type I Bitumen membrane with non-woven (1 square) polyester mat reinforcement for torch application. Flintlastic GTA-FR 39 3/8"x 32' 10';Roll ASTM D 6222,Grade Granule surfaced APP Modified weight: 105 lbs. G,Type I Bitumen membrane with non-woven (1 square) polyester mat reinforcement for torch application. Flintlastic GMS 39 3/8"x 32'10';Roll ASTM D 6164,Grade Granule surfaced SBS Modified weight:941bs. G,Type I Bitumen membrane with non-woven (1 square) polyester mat reinforcement for mop application. Flintlastic FR-P 39 3/8"x 32' 10';Roll ASTM D 6164,Grade Fire resistant,granule surfaced SBS weight: 101 lbs. G,Type I Modified Bitumen Membrane with (1 square) non-woven polyester mat reinforcement for mop i pplication. MIAMI•DADECOUNTY NOA No.:20-0723.28 Expiration Date:01/02/23 Approval Date:09/17/20 Page 2 of 49 i TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY-APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Flintlastic Premium FR-P 39 3/8"x 32' 10";Roll ASTM.D 6164,Grade Fire resistant,granule surfaced SBS weight: 101 lbs. G,Type II Modified Bitumen Membrane with (1 square) non-woven polyester mat reinforcement for mop application. Flintlastic FR Dual Cap 39 3/8"x 32' 10';Roll ASTM D 6162,Grade Granule surfaced SBS modified weight: 103 lbs. G,Type II bitumen membrane with a nonwoven (1 square) polyester/fiberglass composite mat reinforcement for use in cold or mop applications. Flintlastic Cap 30 39 3/8"x 32' 10';Roll ASTM D6163,Grade Granule surfaced SBS Modified weight: 86 lbs. G,Type I Bitumen membrane with fiberglass (1 square) mat reinforcement for mop applications. Flintlastic FR Cap 30 39 3/8"x 32' 10';Roll ASTM D 6163,Grade Fire resistant,granule surfaced SBS weight: 86 lbs. G,Type I Modified Bitumen membrane with (I square) fiberglass mat reinforcement for mop applications. Flintlastic FR Cap 30 T 39 3/8"x 32'10';Roll ASTM D 6163,Grade Granule surfaced SBS Modified weight: 1001bs. G,Type I Bitumen membrane with fiberglass (1 square) mat reinforcement for torch application. Flintlastic Base 20 T 39 3/8"x 33';Roll ASTM D 6163,Grade Modified Bitumen,coated fiberglass Weight:81 lbs. S,Type I base sheet for torch application. (1 square) Flintlastic Ultra Poly SMS 39 3/8"x 32' 10";Roll ASTM D 6164,Grade Smooth surfaced SBS Modified Base Sheet weight:901bs. S,Type I Bitumen Membrane with non-woven (1 square) polyester mat reinforcement for mop applications. Glasbase Base Sheet 39 3/8"x 98'9";Roll ASTM D 4601, Asphalt coated,fiberglass base sheet. weight:75 lbs. Type II (3 squares) UL Type G2 Flintlastic Poly SMS Base 39 3/8"x 64'3";Roll ASTM D 4601, Modified Bitumen coated polyester Sheet weight:90 lbs. Grade S,Type H • base sheet. (2 squares) UL Type G2 Yosemite Venting Base Sheet 39 3/8"x 32'10";Roll ASTM D 3909 Mineral Surfaced fiberglass weight: 85 lbs. ASTM D 4897, reinforced buffer sheet. (1 square) Type II,UL G3 Flintlastic APP Base T 39 3/8"x 65'4";Roll ASTM D6509 Modified Bitumen coated fiberglass weight: 1001bs. base sheet. (2 squares) NOA No.:20-0723.28 Mivr�wuwecourI Expiration Date:01/02/23 ) Approval Date:09/17/20 Page 3 of 49 i I I TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By.APPLICANT: TABLE 1 " 1 Test' Product Product Dimensions Specification Description Flintlastic Ultra Glass SA . 39 3/8"x 33'11';Roll ASTM D1970 Self-adhering,fiberglass reinforced, weight: 73 lbs. SBS modified bitumen Base/ply.. ' �(1 square)• sheet. . Black DiamondTM Base Sheet 36"x 687';Roll ASTM D 1970 Self-adhering fiberglass'reinforced weight: 78 lbs. ASTM D4601 Type I .modified bitumen base sheet 1 , (2 squares) FlintBond Brush 5 gallon pails ASTM'D3019 Cold applied,SBS polymer modified asphalt adhesive. • 4 ' I . I i ' I I .j NOA No.:20-0723.28 ` MiaM® Expiration`Date:01/02/23 Approval Date:09/17/20 Page 4 of 49 • 1 ' I APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) F1intBoard ISO Polyisocyanurate foam insulation CertainTeed LLC. FlintBoard ISO Cold Polyisocyanurate.foam insulation CertainTeed LLC. FlintBoardH ISO Polyisocyanurate foam insulation CertainTeed LLC. FlintBoardH ISO WF Polyisocyanurate foam insulation CertainTeed LLC. FlintBoardH ISO NB Polyisocyanurate foam insulation CertainTeed LLC. FlintBoardH ISO Cold Polyisocyanurate foam insulation CertainTeed LLC. Structodek High Dcnsity Fiberboard Roof Wood fiber insulation board Blue Ridge Fiberboard,Inc. Insulation FescoBoard Expanded perlite and fiber insulation Johns Manville Corp. EnergyGuard Perlite Roof Insulation Perlite insulation board GAF Insulfoam EPS Type IX expanded polystyrene Insulfoam,a Div.of Carlisle Const. Insulation Materials DensDeck Water resistant gypsum board Georgia-Pacific Gypsum LLC DensDeck Prime Water resistant gypsum board Georgia-Pacific Gypsum LLC H-Shield Polyisocyanurate foam insulation Hunter Panels,LLC H-Shield WF Polyisocyanurate foam insulation Hunter Panels,LLC H-Shield NB Polyisocyanurate foam insulation Hunter Panels,,LLC ENRGY 3 Polyisocyanurate foam insulation Johns Manville Corp. ENRGY 3 25 PSI Polyisocyanurate foam insulation Johns Manville,Corp. Multi-Max FA-3 Polyisocyanurate roof insulation RMax Operating,LLC ACFoam-H Polyisocyanurate foam insulation Atlas Roofing Corp. ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp. ISO 95+GL Polyisocyanurate Insulation Firestone Building Products Company,LLC SECUROCK Gypsum-Fiber Roof Board Gypsum insulation United States Gypsum Corp. I i i NOA No�:20-0723.28 e�1AMMAn;Courrrr Expiration Date:01/02/23 Approval Date:09/17/20 Page 5 of 49 I APPROVED FASTENERWADHESIVEs: TABLE 3 i Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Dekfast DF-#12-PH3 Insulation fastener various SFS Group USA,Inc. 2. Dekfast DF-#14-PH3 Insulation fastener various SFS Group'USA,Inc.. 3. Dekfast PLT-H-2-7/8 Galvalume AZ50 steel plate. 2 7/8"x 3 %4" SFS'Group,USA,Inc. 4. Dekfast PLT-R-3 Galvalume AZ50 stress plate 3"x.018" SFS Group'USA,Inc: 5. OMG 3"Galvalume Steel Galvalume stress plate 3"round . OMG,Inc. Plate 6. #12&andard Roofgrip Insulation fastener for wood and various OMG,Inc. steel. - 7. #14 Roofgrip Insulation fastener for wood and various OMG,Inc. steel. 8. 3 in.Ribbed Galvalume Plate Galvalume stress plate. 3"round OMG,Inc. 9. AccuTrac Plate Galvalume stress plate., 3"square OMG,Inc. 10. 3 in.Round Metal Plate Galvalume AZ50.steelplate 3"round OMG,Inc. 11. Flat Bottom Metal Plate Aluminized stress plate 3"square OMG;Inc. . 12. Trufast#14 HD Fastener Insulation fastener for wood and various Altenloh,Brinck& steel decks Co.U-S.,Inc. 13. Trufast 3"Metal Insulation Galvalume AZ50 steel plate 3"round Altenloh,Brinck& Plate Co.U.S.,Inc. 14. Trufast 2.4"Barbed Metal Galvalume AZ50 steel plate 2.4"round Altenloh,Brinck& Seam Plate Co.U.S.,Inc. 15. Trufast#12 DP Fastener Coated,carbon steel screw various Altenloh,Brinck& Co.U.S.,Inc. 16. Dekfast DF-#15-PH3 Coated,carbon steel fastener various SFS Group:USA,Inc. 17. Trufast#15 EHD Fastener Coated,carbon steel screw various Altenloh,Brinck& Co.U.S.,Inc. 18. Dekfast PLT-P-R-3 Polypropylene round stress 3"round SFS Group;USA,Inc. plate. i 19. FlintFast#12 Coated,carbon steel screw various CertainTeed LLC. 20. FlintFast#14 Insulation fastener for wood and various CertainTeed LLC. steel decks 21. FlintFast 3"Insulation Plate Galvalume AZ50 steel plate 3"round CeitainTeed LLC. 22. OMG Heavy Duty Insulation fastener for use in various `OMG,Inc. wood,steel or concrete decks 23. Trufast#21 SHD Fastener Coated,carbon steel screw various Altenloh,Brinck& Co.U.S.,Inc. 24. Trufast 2"Barbed Metal Seam Galvalume steel stress plate 2"round Altenloh,Brinck& Plate Co.U.S.,Inc. - I NOA No.:20-0723.28 MlAM1G1lpBCouN7Y Expiration Date:01/02/23 APPROVED1 Approval Date:09/17/20 age 6 of 49 { i I i APPROVED FASTENERS/ADHESIVES: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 25. Trufast 2.4"Scoop Seam Plate Galvalume steel stress plate 2.47;round. Altenloh,Brinck& Co.U.S.,Inc. 26. Trufast 2-3/4"Barbed Metal Galvalume steel stress plate 2.75"round Altenloh,Brinck& Seam Plate(EHD) Co.U.S.,Inc. 27. F1intFast#15 EHD Coated,carbon steel screw various CertainTeed LLC. 28. FlintFast 2.4"Barbed Seam Galvalume steel stress plate 2.4"round CertainTeed LLC. Plate ' 29. F1intFast 2"Barbed Seam Galvalume steel stress plate 2"round CertainTeed LLC. Plate 30. Millennium One Step Polyurethane two component, 1.5 liters H.B.Fuller Company Foamable Adhesive low rise insulation adhesive 31. Millennium One Step Green Polyurethane two component 1.5 liters H.B.Fuller Company Foamable Adhesive high rise insulation adhesive 32. Millennium PG-1 Low Polyurethane two component 1.5 liters H.B.Fuller Company Viscosity Insulation Adhesive low rise insulation adhesive 33. 1 ICP Adhesive CR-20 Polyurethane two component Two kits(A= ICP Adhesives& low rise insulation adhesive 401b and B= Sealanis,Inc. 351b cylinders) 34. Pliodeck Insulation Adhesive Polyurethane one component Ashland,Inc. low VOC adhesive system 35. Insta Stik Quik Set Insulation Polyurethane one component It is supplied The Dow Chemical moisture curing adhesive in pressurized Company cylinders with a net weight of 23 lbs.,with a total unit weight of 30 i lbs. i 36. OMG OlyBond 500 Adhesive Spray polyurethane foam 10 gal.bag-in- OMG,Inc. insulation adhesive box set and 1.5 liters SpotShot cartridge 37. OMG OlyBond 500 Green Spray polyurethane foam 10 gal.bag-in- OMG,Inc. Adhesive insulation adhesive box set and 1.5 liters SpotShot cartridge NOA No.:20-0723.28 � ;YE�Dj Expiration Date:01/02/23 Approval Date:09/17/20 Page 7 of 49 i I I APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions.Any coating,listed below,used as a surfacing,must be listed within a current NOA. System Manufacturer Application Number 1. Generic Gravel applied at 400 lbs/sq.,adhered with flood coat of asphalt at 60 lbs/sq. 2. Generic Slag applied at 300 lbs/sq.,adhered with flood coat of asphalt at 60 lbs/sq. i 3. Karnak Corp. Karnak(#97 AF)Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 4. CertainTeed LLC. F1intCoat A-150 applied at an application rate of 1.5 gal/sq. 5. Gardner Asphalt Corp. APOC#212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq.. 6. Gardner Asphalt Corp. APOC#400 Sunbrite applied at an application rate of 3 g'al./sq. i I NOA No!:20-0723.28 141AWCAD, Expiration Date:01/02/23 Approval Date:09/17/20 ,Page 8 of 49 I EVIDENCE SUBMITTED: Test Aeency/Identifier Name Report Date Factory Mutual Research Corp. FM 4470 3Y8A1.AM '09/30/96 FM 4470 OD3A3.AM iO4/04/97 FM 4470 2DOAO.AM 12/23/98 FM 4470 3024311 11/01/06 FM 4470 1D7A4.AM 111/09/98 FM 4470 3028410 102/19/07 FM 4470 3031350 ;09/27/07 FM 4470 3036182 W/31/09 FM 4470 3039046 '06/15/10 FM 4470 3039848 ;12/02/11 FM 4470 3046104 08/13/13 FM 4470 3048520 09/19/13 Underwriters Laboratories,Inc. UL 790 R11656 .10/25/12 United States Testvtg Company ASTM D5147 97-457-R2 12/02/87 ASTM D5147 97457-4 06/03/88 Momentum Technologies,Inc. ASTM D6164 AX31G8F 06/05/09 TrinityjERD TAS 117 3515.07.03 -07/22/03 TAS 114(H) Letter 04/05/06 TAS 117(B) 3503.10.06 '10/10/06 TAS 117(B) 06490.04.07-R1 06/27/07 FM 4470/TAS 114 3521.07.04-R1 10/26/07 FM 4470/TAS 114 3533.01.06-R1 .10/26/07 TAS 117(B)/ASTM D6862 C8500SC.11.07 11/30/07 FM 4470/TAS 114 C8370.08.08 08/19/08 TAS 114/TAS 117 C30310.12.09 12/17/09 TAS 117/TAS 114 C30560.06.10 06/10/10 TAS 117 B C35500.02.11 02/09/11 TAS 114 3513.08.02-R1 '03/17/11 FM 4470(K)/TAS 114(J) 03515.07.03-1-R1 ,06/27/12 ASTM D1876/TAS 114(H)/TAS 117 C42110.08.12 ;08/13/12 (B) ASTM D1970 C40050.09.12-2 09/28/12 ASTM D5147/D4798 C31410.10.10-R1 ;11/01/12 ASTM D5147/D4798 C31410.01.11-1-R1 11/01/12 ASTM D4798 C31410.01.11-2A-RI 02/21/13 ASTM D4798 C31410.12.13 12/05/13 ASTM D6222 C40050.12.13-R1 12/31/13 ASTM D2178 C47250.03.14 -03/26/14 ASTM D1876/TAS 114(H)/FM 4474 C47320.03.14 03/26/14 ASTM D1876/TAS 114(H)/FM 4474 C45620.03.14 03/27/14 FM 4474/TAS 114(J) C46760.06.14 '06/19/14 ASTM D1876 C35460.05.11-R1 05/20/15 ASTM D4601 CTR-SC8740.04.15-R2 04/21/15 FM 4474/TAS 114(J),' CTR-SC8995.10.15 10/14/15 NOA No.:20-0723.28 MlAMJAPPRO EDI- Y ,,,� Expiration Date:01/02/23 Approval Date:09/17/20 {Page 9 of 49 I 1 EVIDENCE SUBMITTED: f Test A2encv/Identifier Name Report I Date FM 4474/TAS 114(J) CTR-SC9175.09.16-2 1 09/06/16 FM 4470(K)/UL 1897/TAS 114(J) CTR-SC11590.08.16-R1 09/06/16 ASTM D6163 CTR-SC 11 145.09.16-5A 09/19/16 ASTM D6222 CTR-SC11145.09.16-7A 09/19/16 ASTM D4601-04(2912),Type II CTR SC11145.09.16-3A 09/19/16• PRI Construction Materials ASTM D6163 CTC-056-02-01 ; 08/25/10 Technologies LLC ASTM D6163 CTC-066-02-01 08/09/11 ASTM D6222 CTC-071-02-01 08/08/11 ASTM D6164/D4798 CTC-093-02-01 08/09/11 ASTM D4601 CTC-126-02-01 03/12/12 ASTM D2178 CTC-123-02-01 03/13/12 ASTM D4601 CTC-127-02-01 03/13/12 ASTM D6509 CTC-116-02-01 04/04/12 ASTM D6163 CTC-128-02-01 06/11/12 ASTM D6163 CTC-129-02-01 06/11/12 ASTM D6164 CTC-132-02-01 06/11/12 ASTM D6164 CTC-161-02-01 05/09/11 ASTM D6162 CTC-183-02-01 110/02/13 ASTM D6164 CTC-190-02-01 12/02/13 ASTM D1970 CTC-199-02-01 01/22/14 ASTM D 6163 CTC-319-02-01 08/22/17 ASTM D1970 CTC-320-02-01 08/28/17 DECK STRESS ANALYSIS CALCULATIONS/REPORTS Enginee-/Agency Identifier Assemblies Date Factory Mutual Research Corp. RoofNav Listings B(2),C(5),C(10),C(12) '01/01/13, Robert Nieminen,P.E. Signed/Sealed Calculations 13(1),13(5)through 13(8),C(3), 12/15/16 C(4),C(6)through C(9),C(I 1), D(1)through D(7) NOA No.:20-0723.28 Mi 1AAue�DL Expiration Date:01/02/23 Approval Date:09/17/20 Page 10 of 49 I APPROVED ASSEMBLIES: Membrane Type: APP Modified Deck Type 2I: Steel,Insulated Deck Description: - 22 ga.,Type B,Yield Strength 46 ksi,steel deck is secured at 6 ft.o.c.spans with Tek/5 fasteners spaced 6"o.c. Side-laps are secured with Tek/1 fasteners at 18"O.C. This Tested Assembly has been analyzed for allowable'deck stress. See Evidence Submitted Table. System Type B(1): Base layer of insulation mechanically fastened,top layer adhered with approved Jsphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners fastener able 3 Density/ft2 ACFoam-II,ACFoam_-IIi,F1intBoard ISO,FlintBoard ISO Cold,H-Shield;FlintBoardH ISO Minimum 1.5"thick 15,19 1:1.45 ftz Note: Base layer shall be mechanically attached with fasteners and density described., Insulation panels listed are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall]be increased maintaining the same fastener density(See Roofing Application Standard RAS 117 for fastening details). Top Insulation Laver Insulation Fasteners Fastener able 3 Densi /fe AC Foam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,FlintBoardn ISO Minimum 1.5"thick N/A N/A Note: Top layer of insulation shall be adhered with Millennium One'Step Foamable Adhesive,Millennium One ' Step Green Foamabie Adhesive or Millennium PG-1 Low Viscosity Insulation Adhesive in 0.75 inch ribbons spaced 11 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment:Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. Base Sheet: Oneply of Black Diamond Base Sheet or Flintlastic Ultra"Glass SA,self-adheredjto the insulated substrate. Ply Sheet: One or more plies of Flintlastic APP•Base T or Flintlastic STA,torch adhered to base sheet. (Optional) j Membrane: One ply of Flintlastic GTA,or Flintlastic GTA-FR,torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table'4. . (Optional) Maximum Design 45,psf(See General Limitation#7.) Pressure: NOA No.:20-0723A 'nE Expiration Date:01/02/23 Approval Date:09/17/20 Page 11 of 49 Membrane Type: SBS Modified Deck Type 2I: SteeI,Insulated Deck Description: 18-22 ga.,Type B,Grade 33 steel deck is secured at 6 ft.o.c.spans with ICH Traxx/5 fasteners spaced 6"o.c. Side laps are secured with three ICH Traxx/1 fasteners spaced 24" O.C. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type B(2)-. Base layer of insulation mechanically fastened,top layer adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' ACFoam-II,ACFoam-III,F1intBoard ISO,FlintBoard ISO Cold,ENRGY 3,ISO 95+GL,H-Shield, FlintBoardH ISO Minimum 2.0"thick 1,2,6,7,15,12,19,20 1JA5 fe Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density(See Roofing Application Standard RAS 117 for fastening details). _Ton Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft? SECUROCK Gypsum-Fiber Roof Board Minimum 114"thick N/A N/A I Note: Top layer of insulation shall be adhered with Insta Stik Quik Set Insulation Adhesive,OMG OlyBond 500 Adhesive,OMG OlyBond 500 Green Adhesive,ICP Adhesive CR-20,Millennium One Step Foamable Adhesive, Millennium One Step Green Foamable Adhesive or Millennium PG-1 Low Viscosity Insulation Adhesive in 0.75 inch ribbons spaced 12 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment.Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. ` Base Sheet: One ply of Flintlastic Ultra Glass SA,self-adhered to insulated substrate. Membrane: One ply of Flintlastic Cap 30,Flintlastic FR Cap 30,Flintlastic FR Dual Cap,Flintlastic FR P, Flintlastic GMS,or Flintlastic Premium FR-P adhered to base sheet with approved mopping asphalt applied in full coverage at a rate of 20-25 lb/sq. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf(See General Limitation#7) Pressure: i C NOA No.:20-0723.28 Muaat�naoecOuarry Expiration Date:-0723.28 Approval Date:09/17/20 Page 12 of 49 fy Membrane Type: APP Modified Deck Type 2I: Steel,Insulated Deck Description: 18-22 ga.steel System Type B(3): Base layer of insulation mechanically fastened,optional top layer adhered with appr'ved asphalt. .All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners F istener Table 3 Density/ft2 ACFoam-II,ACFoam-III,F1intBoard ISO;FlintBoard ISO Cold;H-Shield,FlintBoardn ISO' Minimum 1.5"thick 1,2,6,7,12,20 1:2 ft2 Minimum 2"thick 1,2,6,7,'12,20 1r'3.2 ft2 ENRGY 3,ENRGY 3 25 PSI Minimum 1.4"thick 1,2,6,7,12,20 1:2 ft2 Minimum 2"thick 1,2,6,7,12,20 1:3.2 ft2 FescoBoard Minimum 3/"thick 1,2,6,•7 12 20 1i:2 ft2 Structodek High Density Fiberboard Roof Insulation 1 Minimum'/2"thick 1,2,6,7,12,20 1 12 ft2 DensDeck,DensDeck Prime Minimum%"thick 1,2,6,7,12,20. 1-2 ft2 Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall be increased maintaining the same,fastener density(See.Roofing Application Standard RAS 117 for fastening details). Top Insulation Laver(Optional) Insulation Fasteners Fastener- able 31 Density/ft2 Any of the insulations listed for'Base Layer,above. Minimum See Base Layer, N/A N/A Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. I ruArnaae couKrr NOA No.:210-0723.28 PROVE Expiration Date•01/02/23' Approval Date.•09/17/20 Page 13 of 49 i I i Base Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet, Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the insulated substrate with approved mopping asphalt applied within the EVT range and at a rate of 20-40. V Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, (Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or, one or more plies of Flintglas Ply 4 or Flintlglas Premium Ply 6 adhered to base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-401bs./sq.or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic STA or Flintlastic APP Base T torch adhered torch adhered to base sheet. Membrane: Flintlastic GTA,or Flintlastic GTA-FR torch adhered to base or ply sheet. Surfacing: . Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -45 psf.(See General Limitation#9) Pressure: i I I i ,I i NOA No.:20-0723.28 MIAMFQAO+COUNTY11111 Expiration Date:01/02/23 Approval Date:09/17/20 Page 14 of 49 I Membrane Type: SBS Modified j Deck Type 2I: Steel,Insulated Deck Description: 18-22 ga.steel System Type B(4): Base layer of insulation mechanically fastened,optional top layer adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. ' I Base Insulation Laver Insulation Fasteners Fastener Table 3 Densi /ft2 i ACFoam-II,ACFoam-III,FlintBoard ISO,F1intBoard ISO Cold,H-Shield,FlintBoardn ISO Minimum 1.5"thick 1,2,6,7,12,20 1:2 ftz Minimum 2"thick 1,2,6,7,12,20' 1:3.2 ftz ENRGY 3,ENRGY 3 25 PSI Minimum 1:4"thick 1,2,6,7,.12,20 1:2 ftz Minimum 2"thick 1,2,6,7,12,20 1 3.2 ftz FescoBoard Minimum%11 thick 1,2,6,7,12,20 1:2 ftz Structodek High Density Fiberboard Roof Insulation Minimum%"z thick 1,2,6,7,12,20 1:2 ftz DensDeck,DensDeck Prime Minimum'/a"thick 1,2,6,7,12,20 1:2 ftz i Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed are minimum sizes and dimensions;'if larger panels are used the number of fasteners per board shall be increased maintah.ing the same fastener density(See Roofing Application Standard RAS 117 for fastening details). Top Insulation Laver(Optional) Insulation Fasteners Fastener Table 3 Density/fe i Any of the insulations listed for Base Layer,above. Minimum See Base Layer• N/A N/A Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 2040 lbs/100 W. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. I . I NOA No.:20-0723.28 Expiration Date:01/02/23 Approval Date:09/17/20 Page 15 of 49 I Base Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet, Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the insulated substrate with approved mopping asphalt applied within the EVT range and at a rate of 20-40. Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, (Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base sheet or one ply of Flintlastic Ultra Poly SMS Base Sheet torch applied to base sheet. Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic Flintlastic Premium FR-P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq.or Flintlastic FR Cap 30 T torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -45 psf.(See General Limitation#9) Pressure: • I i I I i f 1 NOA No.:'20-0723.28 APPROVED_I -A'MIAMNDADE courrTY Expiration Date:01/02/23 Approval Date:09/17/20 Page 16 of 49 I Membrane Type: APP Modified I Deck Type 2I: Steel,Insulated I Deck Description: 18-22 ga.,Type B,Grade 33 steel deck is secured at 5 ft:o.c.spans with 5/8"paddle welds with weld washers or with Teks 4 fasteners spaced 6"o.c.Side laps are secured with Teks 1 fasteners at 30"o.c This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type B(5): Base layer of insulation mechanically fastened,top layer adhered with approved asphalt. All General and System Limitations apply. iI One or more layers of any of the following insulations. 1 Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ff ACFoam-11,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,ENRGY 3,Multi-Max FA-3,H-Shield, F1intBoardu ISO Minimum 1.5"thick 1,2,6,7,12,20 1:1.33 ftz Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density(See Roofing Application Standard RAS 117 for fastening details). r Tou Insulation Laver Insulation Fasteners Fastener able 3 Density/fF FescoBoard Minimum 3/"thick N/A !N/A Structodek High Density Fiberboard Roof Insulation Minimum%"thick N/A N/A Note: Top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20- 40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment.Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. Base Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet, Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the insulated substrate with approved mopping asphalt applied within the EVT range and at a rate of 20401bs./sq. Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, (Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base sheet or Flintlastic STA or Flintlastic APP Base T torch adhered to base sheet. Membrane: One ply of Flintlastic GTA,or Flintlastic GTA-FR torch adhered to base or ply sheet. NOA No.:20-0723.28 MIAMMWECO= Expiration Date:01/02/23 Approval Date:09/17/20 Page 17 of 49 i I Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) i Maximum Design -52.5 psf.(For FescoBoard)(See General Limitation#7) Pressure: -67.5 psf.(For Structodek High,Density Fiberboard Roof Insulation)(See General Limitation #7) i I i { i I I I I 1 I I 1 I NOA No.:20-0723.28 MIAMMECExpiration Date:01/02/23 Approval Date.'09/17/20 Page 18 of 49 I mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq.or Flintlastic FR Cap 30 T torch adhered to base or ply sheet. i I Surfacing: Any of the approved surfacing/coating options listed in Table 4' (Optional) ` Maximum Design -52.5 psf.(For FescoBoard)(See General Limitation#7 ) � Pressure: -67.5 psf.(For Structodek High Density Fiberboard Roof Insulation) (See General Limitation#7) I I i i NOA No.:120-0723.28 CITA Lwe C4.7.1 Expiration Date:01/02/23 APPROVED Approval Date:09/17/20 Page 20 of 49 I I Membrane Type: APP Modified Deck Type 2I: Steel,Insulated Deck Description: 22 ga.,Type B,Yield Strength 46 ksi,steel deck is secured at 6 ft.o.c.spans with i ek/5 fasteners spaced 6"o.c. Side laps are secured with Tek/1 fasteners at 18"o.c. , This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type B(7): Base layer of insulation mechanically fastened,top layer adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/fe ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,FlintBoardH ISO Minimum 1.5"thick 15,19 1:1.45 ff Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density(See Roofing Application Standard RAS 117 for fastening details). Top Insulation Laver Insulation Fasteners Fastener able 3 Density/ft' SECUROCK Gypsum-Fiber Roof Board Minimum 1/4"thick N/A 'N/A Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive,Millennium One Step Green Foamable Adhesive, Millennium PG-1 Low Viscosity Insulation Adhesive, Insta-Stik'Quik Set Insulation Adhesive,OMG OlyBond 500 Adhesive or OMG OlyBond 500 Green Adhesive in 3/4"-1"wide beads spaced 12 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T,torch adhered to the insulated'substrate. Ply Sheet: One ply of Flintlastic STA or Flintlastic APP Base T,torch adhered to base sheet. (Optional) Membrane: One ply of Flintlastic GTA,or Flintlastic GTA-FR,torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. Maximum Design -75 psf(See General Limitation#7:) Pressure: NOA No.:20-0723.28 Miat� oecouttnr Expiration Date:01/02/23 Approval Date:09/17/20 Page 21 of 49 i I I Membrane Type: SBS Modified. Deck Type 2I: Steel Decks,Insulated Deck Description: 22 ga.,Type B,Yield Strength 46 ksi,steel deck is secured at 6 ft.o.c.spans with Tek/5 fasteners spaced 6"o.c. Side laps are secured with Tek/1 fasteners at 24"o.c. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type B(8): Base layer of insulation mechanically fastened,top layer adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations: Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,FlintBoardH ISO Minimum 1.5"thick 15,19 with 13,21 1:1.6 ft2 Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density(See Roofing Application Standard RAS 117 for fastening details). Top Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' SECUROCK Gypsum-Fiber Roof Board Minimum 1/4"thick N/A N/A Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive,Millennium One Step Green Foamable Adhesive, Millennium PG-1 Low Viscosity Insulation Adhesive, Insta Stik ;Quik Set Insulation Adhesive,OMG OlyBond 500 Adhesive or OMG OlyBond 500 Green Adhesive in 3/4"—1"wide beads spaced 12 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of Flintlastic Poly SMS Base,Flintlastic Ultra Poly SMS Base or Flintlastic Base 20 adhered to the insulated substrate with FlintBond Brush at a rate of 1.0-1.5 gal/sq. Ply Sheet: One ply of Flintlastic-Poly SMS Base,Flintlastic Ultra Poly SMS Base or Flintlastic Base 20 (Optional) adhered to base sheet with Flintbond Brush at a rate of 1.0-1.5 gal/sq. Membrane: One ply of Flintlastic FR Cap 30,Flintlastic FR-P,Flintlastic Premium FR-P or Flintlastic FR Dual Cap adhered to base or ply sheet with FlintBond Brush at a rate of 1.0-1.5 gal/sq. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -75 psf(See General Limitation#7.) Pressure: I NOA No.:20-0723.28 M� wAo Expiration Date:01/02/23 Approval Date:09/17/20 Page 22 of 49 I I i Membrane Type: APP Modified Deck Type 21: Steel Decks,Insulated Deck Description: 18-22 ga.steel. System Type C(1): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. I Base Insulation Laver(Optional) Insulation Fasteners Fastener Table 3 Density/fe ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,ENRGY 3,ENRGY 3 25 PSI,H-Shield, FlintBoardH ISO Minimum 1.5"thick N/A N/A Any Approved Perlite Insulation Listed in Table 2 Minimum 3/"thick N/A i N/A Any Approved High Density Wood Fiberboard Listed in Table 2 Minimum''/z"thick N/A N/A DensDeck,DensDeck Prime Minimum%"thick N/A N/A Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density. Top Insulation Laver Insulation Fasteners Fastener able 3 Density/W Any Approved High Density Wood Fiberboard Listed in Table 2 Minimum'/z"thick 1,2,6,7,12,20 1:2 ftz Any Approved Perlite Insulation Listed in Table 2 Minimum 3/<"thick 1,2,6,.7,12,20 1:2 ft2 DensDeck,DensDeck Prime Minimum'/"thick 1,2,6,7,12,20 1:2 W Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet, Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the insulated substrate with approved mopping asphalt applied within the EVT range and at a rate of 20-401bs./sq. Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, (Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one NOA No.:20-0723.28 Mart Expiration Date:01/02/23 Approval Date:09/17/20 Page 23 of 49 i I • ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Membrane: Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet. i Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design 45 psf.(See General Limitation#9) Pressure: i I I i i I M�a�f�aoE�otnvn NOA No.:20-0723.28 Expiration Date:01/02/23 Approval Date:09/17/20 Page 24 of 49 I i i t i Membrane Type: SBS Modified r Deck Type 2I: Steel Decks,Insulated Deck Description: 18-22 ga.steel. System Type C(2): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver(Optional) Insulation Fasteners Fastener Table 3 Density/W ACFoam-II,ACFoam-III,FlintBoard ISO,F1intBoard ISO Cold,ENRGY 3,ENRGY 3 25 PSI,H-Shield, FlintBoardn ISO Minimum 1.5"thick N/A N/A Any Approved Perlite Insulation Listed in Table 2 Minimum'/"thick N/A N/A Any Approved High Density Wood Fiberboard Listed in Table 2 Minimum'/"thick N/A N/A DensDeck,DensDeck Prime Minimum'/"thick N/A N/A Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density. Top Insulation Laver Insulation Fasteners Fastener able 3 Density/W Any Approved High Density Wood Fiberboard Listed in Table 2 Minimum'/2"thick 1,2,6,7,12,20 1:2 ft- Any Approved Perlite Insulation Listed in Table 2 Minimum'/"thick 1,2,6,7,12,20 1c2 ft2 DensDeck,DensDeck Prime Minimum 1/"thick 1,2,6,7,12,20 1:2 ft' Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment. i NAMWQA=E COUNTY NOA No.:20-0723.28 Expiration Date'01/02/23 Approval Date:09/17/20 Page 25 of 49 I I i I Base Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet, Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the insulated substrate with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. I Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, (Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-401bs.%sq.or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base sheet or Flintlastic Ultra Poly SMS Base Sheet torch applied to base sheet. i Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic FR-P,Flintlastic Premium FR-P,Flintlastic Cap 30 or Flintlastic FR Cap 30, adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq.or Flintlastic FR Cap 30 T torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4 (Optional) Maximum Design -45 psf.(See General Limitation#9) Pressure: i li NOA No.:20-0723.28 JAPPM�AhtN�1 ROV ED I 7Y Expiration Date 01/02/23 Approval Date:09/17/20 Page 26 of 49 I i I I I Membrane Type: SBS/APP Modified Deck Type 2I: Steel,Insulated Deck Description: Min.22 ga.,Type B,Yield Strength 50.6 ksi,steel deck is secured at 6 ft.o.c spans with 5/8" diameter puddle welds spaced 6"o.c.Side laps are secured with Teks 1 fasteners at 118"O.C. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type C(3): All layers of insulation simultaneously attached. Al1.General and System Limitations apply. One or more layer.of any of the following insulations. Base Insulation Laver(Optional) Insulation Fasteners Fastener able 3 Density/fe ACFoam-11,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold Minimum 1.5"thick N/A - i N/A Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density. Top Insulation Laver Insulation Fasteners Fastener able 3 Density/fe ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold Minimum 1.5"thick 12 with 13 or 20 with 21 1 1.78 W Note: Top insulation layer shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA,self-adhered to the insulated substrate. Ply Sheet: One ply of Flintlastic Ultra Poly SMS Base Sheet,Flintlastic Base 20 T,Flintlastic'APP Base (Optional) T or Flintlastic STA torch adhered to base sheet. Membrane: Flintlastic FR Cap 30 T,Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -67.5 psf(See General Limitation V.) Pressure: NOA No::20-0723.28 rnwtwesoe.Dorm Expiration Date:01/02/23 �' Approval Date:09/17/20 Page 27 of 49 I Membrane Type: APP Modified Deck Type 2I: Steel,Insulated Deck Description: 22 ga.,Type B,Yield Strength 46 ksi,steel deck is secured at 6 ft.o.c.spans with Tek/5 fasteners spaced 6"o.c. Side laps are secured with Tek/1 fasteners at 18"o.c. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type C(4): All layers of insulation simultaneously attached. i All General and System Limitations apply. One or more layers of any of the following insulations. I Base Insulation Layer Insulation Fasteners Fastener Table 3 Density/ft' ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,FlintBoardH ISO Minimum 1.5"thick N/A N/A Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density. Top Insulation Laver Insulation Fasteners Fastener able 3 Density/ft' ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,F1intBoardu ISO Minimum 1.5"th'-ck 15,19 1:1.45 ft- Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA,self-adhered to the insulated substrate. Ply Sheet: One or more plies of Flintlastic APP Base T or Flintlastic STA,torch adhered to base sheet. Membrane: One ply of Flintlastic GTA,or Flintlastic GTA-FR,torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -75 psf(See General Limitation#7.) Pressure: i NOA No.:20-0723.28 ED M�a►awaoecov►rrr Expiration Date:01/02/23 __j APPROVED Approval Date:09/17/20 Page 28 of 49 I I I Membrane Type: SBS/APP Modified Deck Type 2I: Steel Decks,Insulated Deck Description: 22 ga.,Type B,Grade 33,steel deck is secured 6 ft.o.c.spans with Teks 5 fastener's spaced 6" o.c. Side laps are secured with Stitch Teks 1 fasteners spaced 24"o.c. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. 1 System Type C(5): Layer of insulation mechanically attached,optional thermal barrier loose laid. All General and System Limitations apply. I Thermal Barrier: Min. '/4"thick DensDeck,SECUROCK Gypsum-Fiber Roof Board loose laid on deck. (Optional) One or more layers of any of the following insulations: Insulation Laver Insulation Fasteners Fastener Table 3 D'ensity/fe ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,FlintBoardH ISO Minimum 1.5"thick 15,16 with 18; 19,21 with 22 1:1.45 ft, Note: Insulation layer shall be mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions;if larger panels are used the number of fasteners per•board shall be increased maintaining the same fastener density(See Rooting Application Standard RAS 117 for fastening details). Base Sheet: One ply of Flintlastic Ultra Glass SA,self-adhered to the insulated substrate. Membrane: One ply of Flintlastic FR Dual Cap,Flintlastic Cap 30,Flintlastic FR-P,Flintlastic GMS or Flintlastic Premium FR-P adhered to base sheet with approved mopping asphalt applied in full coverage at a rate of 20-25 lb/sq.or Flintlastic FR Cap 30 T torch adhered to base sheet. Or One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to base sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -75 psf See General Limitation#7. Pressure: i i I i =M1AAt*VMME§" NOA No.:20-0723.28 Expiration Date:01/02i23 Approval Date:09/17/20 Page 29 of 49 ' I I I i I Membrane Type: APP Modified Deck Type 2I: Steel,Insulated Deck Description: 18-22 ga.,Type B,Grade 33,steel deck secured 6 ft.o.c.spans with puddle welds and washers spaced 6"o.c. Side laps are secured with Teks 1 fasteners spaced 30"o.c. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type C(6): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. i Insulation Laver Insulation Fasteners Fastener able 3 Density/fe ACFoam-H,ACFoam-IH,FlintBoard ISO,FlintBoard ISO Cold,ENRGY 3,Multi-Max FA-3,H-Shield, FlintBoardH ISO Minimum 1.5"thick 2,5,9 1:1.33 ft2 Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. i Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to the insulated substrate. Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, (Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base sheet or Flintlastic STA or Flintlastic APP Base T torch adhered to base sheet. Membrane: One ply of Flintlastic GTA,or Flintlastic GTA-FR torch adhered to base or ply sheet' i Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -82.5 psf(See General Limitation#7) Pressure: I NOA No.:20-0723.28 M ;COU AM Expiration Date:01/02/23 Approval Date:09/17/20 Page 30 of 49 i Membrane Type: SBS Modified j Deck Type 2I: Steel,Insulated Deck Description: 18-22 ga.,Type B,Grade 33,steel deck secured 6 ft.o.c.spans with puddle welds and washers spaced 6"o.c. Side laps are secured with Teks 1 fasteners spaced 30"o.c. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type C(7): All layers of insulation simultaneously attached. All General and System Limitations apply. 1 One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,ENRGY 3,Multi-Max FA-3,H-Shield, FlintBoardH ISO Minimum 1.5"thick 2,5,9 1:.133 ftz Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to the insulated substrate. Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, (Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base sheet or Flintlastic Ultra Poly SMS Base Sheet torch applied to base sheet. Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic FR-P,Flintlastic Premium FR-P,Flintlastic Cap 30,Flintlastic FR Cap 30 or adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq.or Flintlastic FR Cap 30 T torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf;with asphalt-applied cap membranes(See General Limitation#7) Pressure: -82.5 psf;with torch-applied cap membranes(See General Limitation#7) i NOA No.:20-0723.28 Expiration Date.01/02/23 Approval Date-09/17/20 Page 31 of 49 I I Membrane Type: SBS/APP Modified Deck Type 2I: Steel,Insulated Deck Description: Min.22 ga.,Type B,Yield Strength 50.6,steel deck secured 6 ft.o.c.spans with 5%8" diameter puddle welds spaced 6"o.c. Side laps are secured with Teks 1 fasteners spaced 18" O.C. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. I System Type C(8): All layers of insulation simultaneously attached. I All General and System Limitations apply. One or more layers of any of the following insulations. i Base Insulation Laver(Optional) Insulation Fasteners Fastener able 3 Density/ft' SECUROCK Gypsum-Fiber Roof Board .Minimum 0.5"thick N/A i N/A Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density. Top Insulation Laver Insulation Fasteners Fastener able 3 De'nsity/ff SECUROCK Gypsum-Fiber Roof Board Minimum 0.5"thick 12 with 13 or 20 with 21 1.1.6 ft- Note: Top insulation layer shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA,self-adhered to the insulated substrate. Ply Sheet: One ply of Flintlastic Ultra Poly SMS Base Sheet,Fhntlastic Base 20 T,Flintlastic APP Base (Optional) T or Flintlastic STA torch adhered to base sheet. Membrane: Flintlastic FR Cap 30 T,Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -82.5 psf(See General Limitation#7.) Pressure: rtiar�apnoecar�rr NOA No.:20-0723.28 a Expiration Date:01/02/23 Approval Date:09/17/20 Page 32 of 49 i Membrane Type: APP Modified Deck Type 2I: Steel,Insulated i Deck Description: 22 ga.,Type B,Yield Strength 46 ksi,steel deck is secured at 6 ft.o.c.spans with Tek/5 fasteners spaced 6"o.c. Side laps are secured with Tek/l fasteners at 18"o.c. j This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. I System Type C(9): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' ACFoam-II,ACF,)am-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,FlintBoardH ISO Minimum 1.5"thick N/A N/A Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density. Top Insulation Layer Insulation Fasteners Fastener Table 3 Density/ft' SECUROCK Gypsum-Fiber Roof Board j Minimum 1/4"thick 15 with 13,19 with 21 1:1.45 ft2 Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T,torch adhered to the insulated substrate. Ply Sheet: One ply of Flintlastic STA or Flintlastic APP Base T,torch adhered to base sheet. (Optional) Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR,torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. Maximum Design -60 psf(See General Limitation V.) Pressure: I MIAMWAOEGOt1N7Y NOA No.:20-0723.28 Expiration Date:01/02/23 Approval Date:09/17/20 Page 33 of 49 I. Membrane Type: SBS Modified Deck Type 2I: Steel,Insulated Deck Description: 18-22 ga.,Type B,Grade 80 steel deck is secured at 6 ft.o.c.spans with Traxx/5 screws and 3/4"diameter washers spaced 6"o.c. Side laps are secured with Traxx/1 screws spaced 12" O.C. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type C(10): All layers of insulation simultaneously attached. I All General and System Limitations apply. i One or more layers of any of the following insulations. Base Insulation Laver: Insulation Fasteners Fastener Table 3 Density/ft2 H-Shield,FlintBoardn ISO,ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold Minimum 1.5"thick N/A N/A Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density. Ton Insulation Laver: Insulation Fasteners Fastener Table 3 Density/ft' DensDeck Prime Minimum%11 thick 12 with 13,20 with 21 1:1.33 ftz Minimum'/z"thick 12 with 13,20 with 21 1:1 ft. Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Two or three plies of Glasbase Base Sheet,Flexiglas Base Sheet,Flintlastic Base 20, Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet,Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the insulated substrate with approved mopping asphalt applied at a rate of 20 to 25 lbs./sq. Ply Sheet: One ply of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with approved mopping asphalt applied at a rate of 20 to 25 lbs./sq. Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic FR-P,Flintlastic Premium FR-P,Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered with approved mopping.asphalt applied at a rate of 20 to 25 lbs./sq. i MrAMFDADECoi7NiY NOA No.:20-0723.28 • Expiration Date:01/02/23 Approval Date 09/17/20 Page 34 of 49 Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -112.5 psf(fastener density of 1:1.33 fe)(See General Limitation#7) Pressure: -157.5 psf(fastener density of 1:1 if)(See General Limitation#7) a I I i . I } I G I I i I I I NOA No.:20-0723.28 M�nttwwoecoutrnr Expiration Date 01/02/23 JAPPROVEDI_ Approval Date-., 09/17/20 Page 35 of 49 I �I Membrane Type: APP Modified Deck Type 21: Steel,Insulated 1 Deck Description: 22 ga.,.Type F,Grade 80 steel deck is secured at 6 ft.o.c.spans with Tek/5 fasteners and 3/a" washers per fixing point spaced 6"o.c. Side laps are secured with Tek/1 fasteners't 12"o.c. This Tested Assembly has been analyzed for allowable deck stress. See E'videucc Submitted Table. System Type C(1'_): All layers of insulation simultaneously attached. 1 All General and System Limitations apply. One or more layers of any of the following insulations. i Base Insulation Laver Insulation Fasteners Fastener able 3 Density/ft' ACFoam-H,ACFoam-III,FlintBoard ISO,FliutBoard ISO Cold,H-Shield,F1intBoardH ISO Minimum 1.5"thick N/A N/A Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density. Top Insulation Laver Insulation Fasteners Fastener Table 3 Density/fe SECUROCK Gypsum-Fiber Roof Board Minimum 1/4"thick 15 with 13,19 with 21 1:1 ft, i Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation panels li ted are minimum sizes and dimensions;if larger panels are used,the number of fasteners shall be increased maintaining the-same fastener density.Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T,torch adhered to the insulated substrate. Ply Sheet: One ply of Flintlastic STA or Flintlastic APP Base T,torch adhered to base sheet. (Optional) Membrane: One ply of Flintlastic GTA, or Flintlastic GTA-FR,torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. Maximum Design -120 psf(See General Limitation#7.) Pressure: i ItI l NOA No.:20-0723.28 CDAUECOUNTY Expiration Date101/02/23 Approval Date:09/17/20 Page 36 of 49 i Membrane Type: SBS Modified ! Deck Type 2I: Steel,Insulated Deck Description: 18-20 ga.,Type B,Grade 80 steel deck secured at 6 ft.o.c.spans with Traxx/5 screws and%" diameter washers spaced 6"o.c. Side laps are secured with Traxx/1 screws spaced]12"o.c. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type C(12): All layers of insulation simultaneously attached. I All General and System Limitations apply. I One or more layers of any of the following insulations. I Base Insulation Laver: Insulation Fasteners Fastener Table 3 Density/ftz I i H-Shield,FlintBoardH ISO,ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold Minimum 1.5"thick N/A N/A Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density. Top Insulation Laer. Insulation Fasteners Fastener Table 3 Density/W SECUROCK Gypsum-Fiber Roof Board Minimum%"thick 12 with 13,20 with 21 1:!1.33 ft- Minimum%11 thick 12 with 13,20 with 21 1:1 ftz Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Two or three plies of Glasbase Base Sheet,Flexiglas Base Sheet,Flintlastic Base 20: Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet,Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the insulated substrate with approved mopping asphalt applied at a rate of 20 to 25 lbs./sq.or Flintlastic Ultra Poly SMS Base Sheet torch applied to the insulated substrate. Ply Sheet: One ply of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with approved mopping asphalt applied at a rate of 20 to 25 lbs./sq. Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic FR-P,Flintlastic Premium FR-P,Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping asphalt applied at a rate of 20 to 25 lbs./sq. I NOA No.:20-0723.28 JAPPMIAMFDADE COUN3Y . R. Expiration Date:01/02/23 Approval Date:09/17/20 Page 37 of 49 Surfacing: Any of the approved surfacing/coating options listed in Table 4. + (Optional) I Maximum Design -157.5 psf(fastener density of 1:1.33 ft)(See General Limitation#7) Pressure: -172.5 psf(fastener density of 1:1 ft)(See General Limitation#7) 1 I I I I i I i I I I I I I I i NOA No.:20-0723.28 Mtnr�rwat�;�� Expiration Date:01/02/23 Approval Date:09/17/20 Page 38 of 49 Membrane Type: APP/SBS Modified Deck Type 21: Steel,Insulated Deck Description: 22 ga.,Type B,Yield Strength 49.3 ksi,steel deck secured at 6 ft.o.c.with Traxx/5I screws spaced 6"o.c. Side laps are secured with Traxx/l screws spaced 24"o.c. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. j System Type D(1): All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. i Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft, ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold I Minimum 2.0"thick N/A ; N/A I Note: Insulation layer shall have preliminary attachment,prior to the installation of the base sheet at an application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,and four fasteners for any insulation board having no dimension greater than 5 ft. All layers of insulation and base sheet shall be simultaneously fastened.See base sheet below for fasteners and density. Base Sheet: One ply of Flintlastic Ultra Poly SMS Base Sheet mechanically attached as detailed in Fastening below. Lap shall be heat welded. i Fastening#1: Trufast 415 EHD Fasteners or Trufast#21 SHD Fasteners with Trufast 2"Barbed Metal Seam Plates,Trufast 2.4"Barbed Metal Seam Plates,Trufast 2.4"Scoop Seam Plates or Trufast 2- 3/4"Barbed Metal Seam Plates(EHD),FlintFast#15 EHD fasteners with FlintFast'2.4" Barbed Seam Plates or FlintFast 2"Barbed Seam Plates spaced 12"o.c.in a 4"side lap. The lap is heat welded closed encapsulating the fastener row. *Steel deck is attached to structural supports with Traxx/5 screws(one screw per bearing point). (Maximum Design Pressure-52.5 psf,•See General Limitation#7.) Fastening#2: Trufast#15 EHD Fasteners or Trufast#21 SHD Fasteners with Trufast 2.4"Scoop Seam Plates or Trufast 2-3/4"Barbed Metal Seam Plates(EHD)or FlintFast#15 EHD fasteners spaced 12"o.c. in a 4"side lap. The lap is heat welded closed encapsulating the fastener row. *Steel deck is attached to structural supports with Traxx/5 screws(one screw per bearing point). (Maximum Design Pressure-67.5 psf,•See General Limitation#7.) Fastening#3: Trufast#15 EHD Fasteners or Trufast#21 SHD Fasteners with Trufast 2.4"Scoop Seam Plates or Trufast 2-3/4"Barbed Metal Seam Plates(EHD)or FlintFast#15 EHD fasteners spaced 6"o.c.in a 4"side lap. The lap is heat welded closed encapsulating the fastener row. *Steel deck is attached to structural supports with Traxxl5 screws with%"steel washers(one screw/washer per bearing point). (Maximum Design Pressure-112.5 psf,•See General Limitation#7.) i Miar��naoE cOUNSY NOA No.:20-0723.28 JAPPROVEDI__ Expiration Date:01/02/23 Approval Date:09/17/20 Page 39 of 49 Ply Sheet One ply of Flintlastic Ultra Poly SMS Base Sheet torch adhered to base sheet. (Optional): Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR,torched-applied to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) • I Maximum Design See Fastening Above. Pressure: i I I I i i t NOA No.:20-0723.28 MIAMWAAPPROVED TY Expiration Date:01/02/23 Approval Date:09/17/20 Plage 40 of 49 I I Membrane Type: APP Modified j Deck Type 2I: Steel,Insulated Deck Description: 18-22 ga.,(See Fastening Options Below)Type B,steel deck secured at 5 ft.o.c.spans with Traxx/5 screws spaced 6"o.c. Side laps are secured with Traxx/1 screws spaced 26"o.c. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type D(2): All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. j One or more layers of any of the following insulations. I Base Insulation Laver Insulation Fasteners Fastener Table 3 Densitv/ft2 ACFoam-H,ACFoam-III,FtintBoard ISO,FlintBoard ISO Cold,ENRGY 3,Multi Max FA-3,H-Shield, F1intBoardu ISO or Any approved Polyisocyanurate Listed in Table 2 Minimum 1.5"thick N/A N/A Top Insulation Laver(Optional) Insulation Fasteners Fastener able 3 Density1W Any Approved High Density Wood Fiberboard Listed in Table 2 Minimum%"thick N/A I N/A I Any Approved Perlite Insulation Listed in Table 2 Minimum'/4"thick NIA N/A DensDeck,DensDeck Prime Minimum%11 thick N/A N/A Note: Top layer shall have preliminary attachment,prior to the installation of the base sheet at an application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,and four fasteners for any insulation board having no dimension greater than 5 ft. All layers of insulation and base sheet,shall be simultaneously fastened.See base sheet below for fasteners and density. Base Sheet: One ply of Flexiglas Base Sheet,Glasbase Base Sheet*,Flintlastic Base 20,Flintlasltic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet Base Sheet,Yosemite Venting Base Sheet,or Flintlastic APP Base T**.mechanically attached as detailed in Fastening#1 below or one ply of Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet Base Sheet mechanically attached as detailed in Fastening#2 below. *Not with use SFS Dekfast fastening components **With use of SFS Dekfast fastening components I i NOA No. 20-0723.28 rttArtwe►oecounmr Expiration Date:01/02/23 APPROVEDI Approval Date:09/17/20 Page 41 of 49 ' j Fastening#1: OMG#14 Roofgrip Fasteners and OMG 3"Round Metal Plates,Dekfast DF-#12-PH3 with Dekfast PLT-H-2-7/8 plates,OMG#14 Roofgrip with 3 in.Ribbed Galvalume Plates,Flat Bottom Plates,Trufast#14 HD Fastener with Trufast 3"Metal Insulation Plates or FlintFaat #14 fasteners with F1intFast 3"Insulation Plates at a 4"side lap 6"o.c.and two rows staggered in the center of the sheet,6"o.c.Min.Grade 33 steel deck. (Maximum Design Pressure-67.S psf.;See General Limitation#7) Fastening#2: OMG#14 Roofgrip Fasteners and OMG 3"Round Metal Plates,Dekfast DF-#12-PH3 with Dekfast PLT-H-2-7/8 plates,OMG#14 Roofgrip with 3 in.Ribbed Galvalume Plates,Trufast #14 HD Fasteners with Trufast 3"Metal Insulation Plates or F1intFast#14 fasteners with F1intFast 3"Insulation Plates at a 4"side lap 12"o.c.and two rows staggered in the center of the sheet, 12"o.c. 1 Min.Grade 80 steel deck. (Maximum Design Pressure-120 psf.;See General Limitation #7) Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, (Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq.or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base sheet or Flintlastic STA or Flintlastic APP Base T torch adhered to base sheet. Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design See Fastening Above Pressure: i i I I I NOA No.:20-0723.28 tgiattFoanEtourn r Expiration Date:01/02/23 g...O Approval Date:09/17/20 Page 42 of 49 I Membrane Type: SBS Modified Deck Type 2I: Steel,Insulated i Deck Description: 18-22 ga.,(See Fastening Options Below)Type B,steel deck secured at 5 ft.o.c.spans with Traxx/5 screws spaced 6"o.c. Side laps are secured with Traxx/I screws spaced 20"o.c. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type D(3): All layers of insulation and base sheet simultaneously attached. All General and S;stem Limitations apply. One or more layers of any of the following insulations. i Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' ACFoam-H,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,ENRGY 3,Multi Max FA-3,H-Shield, F1intBoardH ISO or Any approved Polyisocyanurate Listed in Table 2 Minimum 1.5"thick N/A N/A i Ton Insulation Laver(Optional) Insulation Fasteners Fastener Table 3 Density/ft' Any Approved High Density Wood Fiberboard Listed in Table 2 Minimum%"thick N/A N/A Any Approved Perlite Insulation Listed in Table 2 Minimum 3/a"thick N/A N/A I DensDeck,DensDeck Prime Minimum'/a"thick N/A N/A Note: Top layer shall have preliminary attachment,prior to the installation of the base sheet at an application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,and four fasteners for any insulation board having no dimension greater than 5 ft. All layers of insulation and base sheet shall be simultaneously fastened.See base sheet below for fasteners and density. Base Sheet: One ply of Flexiglas Base Sheet,Glasbase Base Sheet*,Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or Yosemite Venting Base Sheet mechanically attached as detailed in Fastening#1 below or one ply of Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet Base Sheet mechanically attached as detailed in Fastening#2 below. *Not with use SFS Dekfast fastening components Fastening#1: OMG#14 Roofgrip Fasteners and OMG 3"Round Metal Plates,Dekfast DF412-PH3 with Dekfast PLT-H-2-7/8 plates,OMG#14 Roofgrip with 3 in.Ribbed Galvalume Plates, AccuTrac Flat Bottom Plates,Trufast#14 HD Fastener with Trufast 3"Metal Insulation Plates or FlintFast#14 fasteners with F1intFast 3"Insulation Plates at a 4"side lap 6"o.c.and two rows staggered in the center of the sheet,6"o.c.Min.Grade 33 steel deck. (Maximum Design Pressure-67.5 psf.;See General Limitation#7) Fastening#2: OMG#14 Roofgrip Fasteners and OMG 3"Round Metal Plates,Dekfast DF-#12-PH3 with Dekfast PLT-H-2-7/8 plates,OMG#14 Roofgrip with 3 in.Ribbed Galvalume Plates,Trufast MIAMFDADE CQl1N7Y NOA No. 20-0723.28 Expiration Date:01/02/23 Approval Date:09/17/20 Page 43 of 49 1 414 HD Fastener with Trufast 3"Metal Insulation Plates,or Flintgaat#14 fastenersi with FlintFaat 3"Insulation Plates at a 4"side lap 12"o.c.and two rows staggered in the'center of the sheet, 12"o.c. f Min.Grade 80 steel deck. (Maximum Design Pressure-120 psf.;See General Limitation #7) Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet, (Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401lis./sq.or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base sheet or Flintlastic.Ultra Poly SMS Base Sheet torch applied to base sheet. +; Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic FR-P,Flintlastic Premium FR-P,Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq.or Flintlastic FR Cap 30 T torch adhered to base or ply sheet. i i Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design See Fastening Above Pressure: I i I i a I t 1 I 1 i Muu�Ga�►oecouH7�r NOA No.:20-0723.28 P P R ) Expiration Date:01/02/23 Approval Date:09/17/20 Page 44 of 49 I Membrane Type: APP/SBS Modified Deck Type 2I: Steel,Insulated i Deck Description: 18-22 ga.,Type B,Grade 80,steel deck secured at 5 ft.o.c.spans with Traxx/5 screws spaced 6"o.c. Side laps are secured with Traxx/1 screws spaced 20"o.c. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type D(4): ' All layers of insulation and base sheet simultaneously attached. I All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener Table 3 D'ensity/ft' ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,ENRGY 3,Multi Max FA-3,H-Shield, FlintBoardu ISO or Any approved Polyisocyanurate Listed in Table 2 Minimum 1.5"thick N/A N/A Note: Insulation layer shall have preliminary attachment,prior to the installation of the base sheet at an application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,and four fasteners for any insulation board having no dimension greater than 5 ft. All layers of insulation;and base sheet shall be simultaneously fastened.See base sheet below for fasteners and density. 1 I Base Sheet: One ply of Flintlastic Ultra Poly SMS Base Sheet Base Sheet mechanically attached as detailed in Fastening below. Lap shall be heat welded. Fastening#1: Trufast#15 EHD Fasteners with Trufast 2.4"Barbed Metal Seam Plates or FlintFast#15 EHD fasteners with F1intFast 2.4"Barbed Seam Plates spaced 12"o.c.in a 4"side lap. The lap is heat welded closed encapsulating the fastener row. Membrane: One ply of Flintlastic GTA,Flintlastic GTA-FR or Flintlastic FR Cap 30 T torch adhered to base sheet. I Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -60 psf.(See General Limitation#7) Pressure: i I i NOA No.:20-0723.28 ,RAM; -1A 0lJ 91 a# Expiration Date:01/02/23 Approval Date:09/17/20 'Page 45 of 49 i I Membrane Type: SBS Modified i Deck Type 2I: Steel,Insulated Deck Description: Min.22 ga.,Type B,Yield Strength 50.6 ksi,steel deck secured at 6 ft.o.c.spans with 5/8" diameter puddle welds spaced 6"o.c. Side laps are secured with Teks 1 fasteners spaced 18" O.C. I This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type D(5): All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' Any Approved Polyisocyanurate Listed in Table 2 Minimum 1.0"thick N/A N/A Note: Insulation layer shall have preliminary attachment,prior to the installation of the base sheet at an application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,and four fasteners for any insulation board having no dimension greater than 5 ft. All layers of insulation"and base sheet shall be simultaneously fastened.See base sheet below for fasteners and density. Base Sheet: One ply of Glasbase Base Sheet,Flexiglas Base Sheet,Flintlastic Base 20,Yosemite Venting Base,Flintlastic Poly SMS Base and Flintlastic Ultra Poly SMS Base,mechanically attached as described below. Fastening#1: Trufast#14 HD Fasteners with Trufast 3"Metal Insulation Plates,F1intFast#14 fasteners with FlintFast 3"Insulation Plates spaced 6"o.c.at the 4"wide laps and 12"o.c.in three,equally spaced staggered center rows. Ply Sheet: One ply of Flintlastic Base 20,Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS (Optional) Base Sheet applied in F1intBond Brush at a rate of 1—1.5 gal/sq to base sheet. Membrane: One ply of Flintlastic Cap 30,Flintlastic FR Cap 30,Flintlastic FR Dual Cap,Flintlastic FR- P,Flintlastic Premium FR-P or Flintlastic GMS applied in FlintBond Brush at a rate of I—4.5 gal/sq to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -75 psf.(See General Limitation#T) Pressure: i I IE f Mtartwauecourm NOA No.:20-0723.28 •+ + Expiration Date:01/02/23 Approval Date:09/17/20 i Page 46 of 49 I f Membrane Type: SBS Modified j Deck Type 2I: Steel,Insulated , Deck Description: 18-22 ga.,Type B,Grade 80,steel deck secured at 5 ft.o.c.with Traxx/5 screws sp�ced 6" o.c. Side laps are secured with Traxx/1 screws spaced 20"o.c. I This Tested Assembly-has been analyzed for allowable deck stress. See Evidence Submitted Table. j System Type D(6,,: All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. 1 Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' Any Approved Polyisocyanurate listed in Table 2 Minimum 1.5"thick N/A N/A Note: Insulation layer shall have preliminary attachment,prior to the installation of the base sheet at an application rate of two fasteners per board for insulation boards having no dimension greater than 4 it.,and four fasteners for any insulation board having no dimension greater than 5 ft. All layers of insulation and base sheet shall be simultaneously fastened.See base sheet below for fasteners and density. Base Sheet: One ply of Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet Base Sheet mechanically attached as detailed in Fastening below. Fastening#1: OMG#14 Roofgrip Fasteners and OMG 3"Round Metal Plates,Dekfast DF-912-PH3 with Dekfast PLT-H-2-7/8 plates,OMG#14 Roofgrip with 3 in.Ribbed Galvalume Plates,Trufast #14 HD Fastener with Trufast 3"Metal Insulation Plates or FlintFast#14 fastener's with F1intFast 3"Insulation Plates spaced 12-inch o.c.in the 4-inch wide lap and 12-inch o.c.in two equally spaced staggered rows in the field. Ply Sheet: One ply of Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base Sheet,torch adhered to (Optional) base sheet. Membrane: One ply of Flintlastic FR Cap 30 T,torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -112.5 psf.(See General Limitation 97) Pressure: j I NOA No.:20-0723.28 'MtAMHMME ff Y T Expiration Date:01/02/23 Approval Date:09/17/20 i Page 47 of 49 I I Membrane Type: APP/SBS Modified Deck Type 2I: Steel,Insulated Deck Description: Min.22 ga.,Type B,Grade 80,steel deck secured at 6 ft.o.c.with Traxx/5 screws with 3/4" steel washers(two screws/washers per bearing point)spaced 6"o.c.. Steel side laps are secured with Traxx/I fasteners spaced 24"o.c. This Tested Assembly has been analyzed for allowable deck stress. See Evidence Submitted Table. System Type D(7): All layers of insulation and base sheet simultaneously attached. i All General and System Limitations apply. + One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener Table 3 D'ensity/ft2 ACFoam-II,ACFoam-III,FlintBoard ISO,F1intBoard ISO Cold Minimum 2.0"thick N/A N/A Note: Insulation layer shall have preliminary attachment,prior to the installation of the base sheet at an application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,and four fasteners for any insulation board having no dimension greater than 5 ft. All layers of insulation:and base sheet shall be simultaneously fastened.See base sheet below for fasteners and density. Base Sheet: One ply of Flintlastic Ultra Poly SMS Base Sheet Base Sheet mechanically attached as detailed in Fastening below. Lap shall be heat welded. Fastening#1: Trufast#15 EHD Fasteners or Trufast#21 SHD Fasteners with Trufast 2.4"Scoop Seam Plates or Trufast 2-3/4"Barbed Metal Seam Plates(EHD)or FlintFast#15 EHD fasteners spaced 6"o.c.in a 4"side lap. The lap is heat welded closed encapsulating the fastener row. Ply Sheet One ply of Flintlastic Ultra Poly SMS Base Sheet torch-applied to base sheet. (Optional): Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch-applied to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -165 psf.(See General Limitation#7.) Pressure: i i I I . i NOA No.:20-0723.28 Expiration Date:01/02/23 E Pal Approval Date:09/17/20 Page 48 of 49 i STEEL DECK SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is propos i ed, a field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117,calculations shall be signed and sealed by a Florida registered Professional Engineer, Registered Architect or Registered Roof Consultant, 2. For steel deck application where specific deck construction is not referenced: The deck shall be a minimum 22 gage attached with 5/8"puddle welds with weld washers at every flute with maximum deck spans of 5 ft.o.c. GENERAL LIMITATIONS: I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate.of 2040 lbs./sq.or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment: When applied in approved asphalt,panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped.If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12"diameter circles,24"o.c.;or strip mopped 8"ribbons in three rows,one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6"break shall be placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. j 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested,are below 275 Ibf.insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing, prepared,signed and sealed by a Florida registered Professional Engineer,Registered Architect or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect or Registered Roof Consultant(When this limitation is specifically referred within this NOA, General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to Roofing Application Standard RAS 11 I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e.field, perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended comers and corners).(When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) ' 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE I NOA No.:20-0723.28 rut►�tNoao; Expiration Date:01/02/23 Approval Date:09/17/20 Page 49 of 49 I