HomeMy WebLinkAboutNotice of Acceptance (2) MIAMI BADE MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525 99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
CertainTeed LLC.
20 Moores Road
Malvern,PA 19355
SCOPE: .
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County.and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use )f such-product or material within their jurisdiction. RER reserves the right to revoke this
acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Modified Bitumen Roof Systems over Steel Decks.
LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and$ollowing
statement: "Miami=Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
-materials,use,andior manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
.INSPECTION:A copy of this entire NOA shall be provided to the user,by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#20-0110.10 and consists of pages 1 through 49.
The submitted documentation was reviewed by Alex Tigera.
I
NOA No.:20-0723.28
MIAMMWEcoutQ . Expiration Date:01/02/23
Approval Date:09/17/20
i Pagel of 49
FAVE COPY
I
Membrane Type:. SBS Modified
Deck Type 2I: Steel,Insulated
Deck Description: 18-22 ga.,Type B,Grade 33 steel deck is secured at 5 ft.o.c.spans with 5/8"paddle welds
with weld washers or with e T ks 4 fasteners spaced 6 o.c.Side laps are secured with Teks 1
fasteners at 30"o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table:
System Type B(6): Base layer of insulation mechanically fastened,top layer adhered with approved asphalt.
All General and System Limitations apply.
i
One or more layers of any of the following insulations. . i
• i'
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft' '
ACFoam-II,ACFoam-III,FlintBoard ISO,F1intBoard ISO Cold;ENRGY 3,Multi-Max FA-3,H-Shield,'
FlintBoardH ISO -
Minimum 1.5"thick 1,2,6,7,12,20 1:1.33 ft2
Note: Base layer shall be mechanically attached with fasteners and density described."Insulation panels listed
are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall tie
increased maintaining.the same fastener density(See Roofing Application Standard RAS 117 for fastening
details).
Too Insulation Laver 'Insulation Fasteners Fastener
able 3 Density/ft'
FescoBoard
Minimum%11 thick N/A N/A
Stuctodek High Density Fiberboard Roof Insulation
Minimum%2"thick N/A N/A
Note: Top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20
40 lbs/160 ft'. Please refer to Roofing Application Standard RAS 117 for insulation attachment.Composite
insulation boards used as a.top layer shall be installed with the polyisocyanurate face down.
Base Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
Flintlastic Base.20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet,
Flintglas Ply 4 or Flintglas Prernium Ply 6 adhered to the insulated substrate with approved
mopping asphalt applied within the EVT range and at a rate of 20401bs./sq.
Ply Sheet:, One ply of All Weather/Empire Base Sheet,.Glasbase Base Sheet,Flexiglas Base Sheet,
(Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or
one or more plies of Flintglas Ply 4 or Flintglas.Premium Ply 6 adhered to-base sheet with
approved mopping asphalt applied within the EVT range and at,a rate of 20-40 lbs./sq.or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base;sheet or
Flintlastic Ultra Poly SMS Base Sheet torch applied to base sheet..
Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic FR-P,Flintlastic Premium.
FR-P;Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
MIAM4QauE�ov�rr NOA No.:120-0723.28
Expiration Date:01/02/23
Approval Date:09/17/20
Page 19 of 49
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Category: Modified
Material: APP,SBS
Deck Type: Steel
Maximum Design Pressure: -172.5 psL
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product '
Product Dimensions Specification Description'
All Weather/Empir-Base 39 3/8"x 65'10'; ASTM D 4601, Asphalt coated,fiberglass reinforced
Sheet Roll weight:701bs. Type II base sheet.
(2 squares)
Flexiglas Base Sheet 39 3/8"x 98'9";Roll ASTM D 4601, Modified Bitumen coated fiberglass
weight:901bs. Type II base sheet.
(3 squares)
Flintlastic Base 20 39 3/8"x 49'6";Roll ASTM D 6163, Modified Bitumen coated fiberglass
weight:90 lbs. Grade S,Type I base sheet.
(1.5 squares)
Flintglas Ply 4 . 39 3/8"x 164'7";Roll ASTM D 2178, Fiberglass,asphalt impregnated ply
weight:38 lbs. Type IV sheet.
(5 squares) UL Type G1
Flintglas Premium Ply 6 39 3/8"x 1647';Roll ASTM D 2178, Fiberglass,asphalt impregnated ply
weight:401bs. Type VI sheet..
(5 squares) UL Type G1
Flintlastic STA 39 3/8"x 32'10";Roll ASTM D 6222,Grade Smooth surfaced APP MI odified
weight:871bs. S,Type I Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for
torch application.
Flintlastic GTA 39 3/8"x 32' 10";Roll ASTM D 6222,Grade Granule surfaced APP Modified
weight: 1051bs. G,Type I Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for
torch application.
Flintlastic GTA-FR 39 3/8"x 32' 10';Roll ASTM D 6222,Grade Granule surfaced APP Modified
weight: 105 lbs. G,Type I Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for
torch application.
Flintlastic GMS 39 3/8"x 32'10';Roll ASTM D 6164,Grade Granule surfaced SBS Modified
weight:941bs. G,Type I Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for mop
application.
Flintlastic FR-P 39 3/8"x 32' 10';Roll ASTM D 6164,Grade Fire resistant,granule surfaced SBS
weight: 101 lbs. G,Type I Modified Bitumen Membrane with
(1 square) non-woven polyester mat
reinforcement for mop i pplication.
MIAMI•DADECOUNTY
NOA No.:20-0723.28
Expiration Date:01/02/23
Approval Date:09/17/20
Page 2 of 49
i
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY-APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Flintlastic Premium FR-P 39 3/8"x 32' 10";Roll ASTM.D 6164,Grade Fire resistant,granule surfaced SBS
weight: 101 lbs. G,Type II Modified Bitumen Membrane with
(1 square) non-woven polyester mat
reinforcement for mop application.
Flintlastic FR Dual Cap 39 3/8"x 32' 10';Roll ASTM D 6162,Grade Granule surfaced SBS modified
weight: 103 lbs. G,Type II bitumen membrane with a nonwoven
(1 square) polyester/fiberglass composite mat
reinforcement for use in cold or mop
applications.
Flintlastic Cap 30 39 3/8"x 32' 10';Roll ASTM D6163,Grade Granule surfaced SBS Modified
weight: 86 lbs. G,Type I Bitumen membrane with fiberglass
(1 square) mat reinforcement for mop
applications.
Flintlastic FR Cap 30 39 3/8"x 32' 10';Roll ASTM D 6163,Grade Fire resistant,granule surfaced SBS
weight: 86 lbs. G,Type I Modified Bitumen membrane with
(I square) fiberglass mat reinforcement for mop
applications.
Flintlastic FR Cap 30 T 39 3/8"x 32'10';Roll ASTM D 6163,Grade Granule surfaced SBS Modified
weight: 1001bs. G,Type I Bitumen membrane with fiberglass
(1 square) mat reinforcement for torch
application.
Flintlastic Base 20 T 39 3/8"x 33';Roll ASTM D 6163,Grade Modified Bitumen,coated fiberglass
Weight:81 lbs. S,Type I base sheet for torch application.
(1 square)
Flintlastic Ultra Poly SMS 39 3/8"x 32' 10";Roll ASTM D 6164,Grade Smooth surfaced SBS Modified
Base Sheet weight:901bs. S,Type I Bitumen Membrane with non-woven
(1 square) polyester mat reinforcement for mop
applications.
Glasbase Base Sheet 39 3/8"x 98'9";Roll ASTM D 4601, Asphalt coated,fiberglass base sheet.
weight:75 lbs. Type II
(3 squares) UL Type G2
Flintlastic Poly SMS Base 39 3/8"x 64'3";Roll ASTM D 4601, Modified Bitumen coated polyester
Sheet weight:90 lbs. Grade S,Type H • base sheet.
(2 squares) UL Type G2
Yosemite Venting Base Sheet 39 3/8"x 32'10";Roll ASTM D 3909 Mineral Surfaced fiberglass
weight: 85 lbs. ASTM D 4897, reinforced buffer sheet.
(1 square) Type II,UL G3
Flintlastic APP Base T 39 3/8"x 65'4";Roll ASTM D6509 Modified Bitumen coated fiberglass
weight: 1001bs. base sheet.
(2 squares)
NOA No.:20-0723.28
Mivr�wuwecourI Expiration Date:01/02/23
) Approval Date:09/17/20
Page 3 of 49
i
I
I
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By.APPLICANT:
TABLE 1 " 1
Test' Product
Product Dimensions Specification Description
Flintlastic Ultra Glass SA . 39 3/8"x 33'11';Roll ASTM D1970 Self-adhering,fiberglass reinforced,
weight: 73 lbs. SBS modified bitumen Base/ply.. '
�(1 square)• sheet. .
Black DiamondTM Base Sheet 36"x 687';Roll ASTM D 1970 Self-adhering fiberglass'reinforced
weight: 78 lbs. ASTM D4601 Type I .modified bitumen base sheet
1 ,
(2 squares)
FlintBond Brush 5 gallon pails ASTM'D3019 Cold applied,SBS polymer modified
asphalt adhesive.
• 4
' I
. I
i
' I
I
.j
NOA No.:20-0723.28
` MiaM® Expiration`Date:01/02/23
Approval Date:09/17/20
Page 4 of 49
• 1
' I
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description Manufacturer
(With Current NOA)
F1intBoard ISO Polyisocyanurate foam insulation CertainTeed LLC.
FlintBoard ISO Cold Polyisocyanurate.foam insulation CertainTeed LLC.
FlintBoardH ISO Polyisocyanurate foam insulation CertainTeed LLC.
FlintBoardH ISO WF Polyisocyanurate foam insulation CertainTeed LLC.
FlintBoardH ISO NB Polyisocyanurate foam insulation CertainTeed LLC.
FlintBoardH ISO Cold Polyisocyanurate foam insulation CertainTeed LLC.
Structodek High Dcnsity Fiberboard Roof Wood fiber insulation board Blue Ridge Fiberboard,Inc.
Insulation
FescoBoard Expanded perlite and fiber insulation Johns Manville Corp.
EnergyGuard Perlite Roof Insulation Perlite insulation board GAF
Insulfoam EPS Type IX expanded polystyrene Insulfoam,a Div.of Carlisle Const.
Insulation Materials
DensDeck Water resistant gypsum board Georgia-Pacific Gypsum LLC
DensDeck Prime Water resistant gypsum board Georgia-Pacific Gypsum LLC
H-Shield Polyisocyanurate foam insulation Hunter Panels,LLC
H-Shield WF Polyisocyanurate foam insulation Hunter Panels,LLC
H-Shield NB Polyisocyanurate foam insulation Hunter Panels,,LLC
ENRGY 3 Polyisocyanurate foam insulation Johns Manville Corp.
ENRGY 3 25 PSI Polyisocyanurate foam insulation Johns Manville,Corp.
Multi-Max FA-3 Polyisocyanurate roof insulation RMax Operating,LLC
ACFoam-H Polyisocyanurate foam insulation Atlas Roofing Corp.
ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp.
ISO 95+GL Polyisocyanurate Insulation Firestone Building Products
Company,LLC
SECUROCK Gypsum-Fiber Roof Board Gypsum insulation United States Gypsum Corp.
I
i
i
NOA No�:20-0723.28
e�1AMMAn;Courrrr Expiration Date:01/02/23
Approval Date:09/17/20
Page 5 of 49
I
APPROVED FASTENERWADHESIVEs:
TABLE 3
i
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1. Dekfast DF-#12-PH3 Insulation fastener various SFS Group USA,Inc.
2. Dekfast DF-#14-PH3 Insulation fastener various SFS Group'USA,Inc..
3. Dekfast PLT-H-2-7/8 Galvalume AZ50 steel plate. 2 7/8"x 3 %4" SFS'Group,USA,Inc.
4. Dekfast PLT-R-3 Galvalume AZ50 stress plate 3"x.018" SFS Group'USA,Inc:
5. OMG 3"Galvalume Steel Galvalume stress plate 3"round . OMG,Inc.
Plate
6. #12&andard Roofgrip Insulation fastener for wood and various OMG,Inc.
steel. -
7. #14 Roofgrip Insulation fastener for wood and various OMG,Inc.
steel.
8. 3 in.Ribbed Galvalume Plate Galvalume stress plate. 3"round OMG,Inc.
9. AccuTrac Plate Galvalume stress plate., 3"square OMG,Inc.
10. 3 in.Round Metal Plate Galvalume AZ50.steelplate 3"round OMG,Inc.
11. Flat Bottom Metal Plate Aluminized stress plate 3"square OMG;Inc.
. 12. Trufast#14 HD Fastener Insulation fastener for wood and various Altenloh,Brinck&
steel decks Co.U-S.,Inc.
13. Trufast 3"Metal Insulation Galvalume AZ50 steel plate 3"round Altenloh,Brinck&
Plate Co.U.S.,Inc.
14. Trufast 2.4"Barbed Metal Galvalume AZ50 steel plate 2.4"round Altenloh,Brinck&
Seam Plate Co.U.S.,Inc.
15. Trufast#12 DP Fastener Coated,carbon steel screw various Altenloh,Brinck&
Co.U.S.,Inc.
16. Dekfast DF-#15-PH3 Coated,carbon steel fastener various SFS Group:USA,Inc.
17. Trufast#15 EHD Fastener Coated,carbon steel screw various Altenloh,Brinck&
Co.U.S.,Inc.
18. Dekfast PLT-P-R-3 Polypropylene round stress 3"round SFS Group;USA,Inc.
plate.
i
19. FlintFast#12 Coated,carbon steel screw various CertainTeed LLC.
20. FlintFast#14 Insulation fastener for wood and various CertainTeed LLC.
steel decks
21. FlintFast 3"Insulation Plate Galvalume AZ50 steel plate 3"round CeitainTeed LLC.
22. OMG Heavy Duty Insulation fastener for use in various `OMG,Inc.
wood,steel or concrete decks
23. Trufast#21 SHD Fastener Coated,carbon steel screw various Altenloh,Brinck&
Co.U.S.,Inc.
24. Trufast 2"Barbed Metal Seam Galvalume steel stress plate 2"round Altenloh,Brinck&
Plate Co.U.S.,Inc.
- I
NOA No.:20-0723.28
MlAM1G1lpBCouN7Y Expiration Date:01/02/23 APPROVED1
Approval Date:09/17/20
age 6 of 49
{
i
I
i
APPROVED FASTENERS/ADHESIVES:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
25. Trufast 2.4"Scoop Seam Plate Galvalume steel stress plate 2.47;round. Altenloh,Brinck&
Co.U.S.,Inc.
26. Trufast 2-3/4"Barbed Metal Galvalume steel stress plate 2.75"round Altenloh,Brinck&
Seam Plate(EHD) Co.U.S.,Inc.
27. F1intFast#15 EHD Coated,carbon steel screw various CertainTeed LLC.
28. FlintFast 2.4"Barbed Seam Galvalume steel stress plate 2.4"round CertainTeed LLC.
Plate '
29. F1intFast 2"Barbed Seam Galvalume steel stress plate 2"round CertainTeed LLC.
Plate
30. Millennium One Step Polyurethane two component, 1.5 liters H.B.Fuller Company
Foamable Adhesive low rise insulation adhesive
31. Millennium One Step Green Polyurethane two component 1.5 liters H.B.Fuller Company
Foamable Adhesive high rise insulation adhesive
32. Millennium PG-1 Low Polyurethane two component 1.5 liters H.B.Fuller Company
Viscosity Insulation Adhesive low rise insulation adhesive
33. 1 ICP Adhesive CR-20 Polyurethane two component Two kits(A= ICP Adhesives&
low rise insulation adhesive 401b and B= Sealanis,Inc.
351b cylinders)
34. Pliodeck Insulation Adhesive Polyurethane one component Ashland,Inc.
low VOC adhesive system
35. Insta Stik Quik Set Insulation Polyurethane one component It is supplied The Dow Chemical
moisture curing adhesive in pressurized Company
cylinders with
a net weight of
23 lbs.,with a
total unit
weight of 30 i
lbs.
i
36. OMG OlyBond 500 Adhesive Spray polyurethane foam 10 gal.bag-in- OMG,Inc.
insulation adhesive box set and 1.5
liters SpotShot
cartridge
37. OMG OlyBond 500 Green Spray polyurethane foam 10 gal.bag-in- OMG,Inc.
Adhesive insulation adhesive box set and 1.5
liters SpotShot
cartridge
NOA No.:20-0723.28
� ;YE�Dj Expiration Date:01/02/23
Approval Date:09/17/20
Page 7 of 49
i
I
I
APPROVED SURFACING/COATING OPTIONS:
TABLE 4
Chosen components must be applied according to manufacturer's application instructions.Any coating,listed
below,used as a surfacing,must be listed within a current NOA.
System Manufacturer Application
Number
1. Generic Gravel applied at 400 lbs/sq.,adhered with flood coat of asphalt at 60
lbs/sq.
2. Generic Slag applied at 300 lbs/sq.,adhered with flood coat of asphalt at 60
lbs/sq. i
3. Karnak Corp. Karnak(#97 AF)Fibrated Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
4. CertainTeed LLC. F1intCoat A-150 applied at an application rate of 1.5 gal/sq.
5. Gardner Asphalt Corp. APOC#212 Fibered Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq..
6. Gardner Asphalt Corp. APOC#400 Sunbrite applied at an application rate of 3 g'al./sq.
i
I
NOA No!:20-0723.28
141AWCAD, Expiration Date:01/02/23
Approval Date:09/17/20
,Page 8 of 49
I
EVIDENCE SUBMITTED:
Test Aeency/Identifier Name Report Date
Factory Mutual Research Corp. FM 4470 3Y8A1.AM '09/30/96
FM 4470 OD3A3.AM iO4/04/97
FM 4470 2DOAO.AM 12/23/98
FM 4470 3024311 11/01/06
FM 4470 1D7A4.AM 111/09/98
FM 4470 3028410 102/19/07
FM 4470 3031350 ;09/27/07
FM 4470 3036182 W/31/09
FM 4470 3039046 '06/15/10
FM 4470 3039848 ;12/02/11
FM 4470 3046104 08/13/13
FM 4470 3048520 09/19/13
Underwriters Laboratories,Inc. UL 790 R11656 .10/25/12
United States Testvtg Company ASTM D5147 97-457-R2 12/02/87
ASTM D5147 97457-4 06/03/88
Momentum Technologies,Inc. ASTM D6164 AX31G8F 06/05/09
TrinityjERD TAS 117 3515.07.03 -07/22/03
TAS 114(H) Letter 04/05/06
TAS 117(B) 3503.10.06 '10/10/06
TAS 117(B) 06490.04.07-R1 06/27/07
FM 4470/TAS 114 3521.07.04-R1 10/26/07
FM 4470/TAS 114 3533.01.06-R1 .10/26/07
TAS 117(B)/ASTM D6862 C8500SC.11.07 11/30/07
FM 4470/TAS 114 C8370.08.08 08/19/08
TAS 114/TAS 117 C30310.12.09 12/17/09
TAS 117/TAS 114 C30560.06.10 06/10/10
TAS 117 B C35500.02.11 02/09/11
TAS 114 3513.08.02-R1 '03/17/11
FM 4470(K)/TAS 114(J) 03515.07.03-1-R1 ,06/27/12
ASTM D1876/TAS 114(H)/TAS 117 C42110.08.12 ;08/13/12
(B)
ASTM D1970 C40050.09.12-2 09/28/12
ASTM D5147/D4798 C31410.10.10-R1 ;11/01/12
ASTM D5147/D4798 C31410.01.11-1-R1 11/01/12
ASTM D4798 C31410.01.11-2A-RI 02/21/13
ASTM D4798 C31410.12.13 12/05/13
ASTM D6222 C40050.12.13-R1 12/31/13
ASTM D2178 C47250.03.14 -03/26/14
ASTM D1876/TAS 114(H)/FM 4474 C47320.03.14 03/26/14
ASTM D1876/TAS 114(H)/FM 4474 C45620.03.14 03/27/14
FM 4474/TAS 114(J) C46760.06.14 '06/19/14
ASTM D1876 C35460.05.11-R1 05/20/15
ASTM D4601 CTR-SC8740.04.15-R2 04/21/15
FM 4474/TAS 114(J),' CTR-SC8995.10.15 10/14/15
NOA No.:20-0723.28
MlAMJAPPRO EDI- Y
,,,� Expiration Date:01/02/23
Approval Date:09/17/20
{Page 9 of 49
I
1
EVIDENCE SUBMITTED: f
Test A2encv/Identifier Name Report I Date
FM 4474/TAS 114(J) CTR-SC9175.09.16-2 1 09/06/16
FM 4470(K)/UL 1897/TAS 114(J) CTR-SC11590.08.16-R1 09/06/16
ASTM D6163 CTR-SC 11 145.09.16-5A 09/19/16
ASTM D6222 CTR-SC11145.09.16-7A 09/19/16
ASTM D4601-04(2912),Type II CTR SC11145.09.16-3A 09/19/16•
PRI Construction Materials ASTM D6163 CTC-056-02-01 ; 08/25/10
Technologies LLC ASTM D6163 CTC-066-02-01 08/09/11
ASTM D6222 CTC-071-02-01 08/08/11
ASTM D6164/D4798 CTC-093-02-01 08/09/11
ASTM D4601 CTC-126-02-01 03/12/12
ASTM D2178 CTC-123-02-01 03/13/12
ASTM D4601 CTC-127-02-01 03/13/12
ASTM D6509 CTC-116-02-01 04/04/12
ASTM D6163 CTC-128-02-01 06/11/12
ASTM D6163 CTC-129-02-01 06/11/12
ASTM D6164 CTC-132-02-01 06/11/12
ASTM D6164 CTC-161-02-01 05/09/11
ASTM D6162 CTC-183-02-01 110/02/13
ASTM D6164 CTC-190-02-01 12/02/13
ASTM D1970 CTC-199-02-01 01/22/14
ASTM D 6163 CTC-319-02-01 08/22/17
ASTM D1970 CTC-320-02-01 08/28/17
DECK STRESS ANALYSIS CALCULATIONS/REPORTS
Enginee-/Agency Identifier Assemblies Date
Factory Mutual Research Corp. RoofNav Listings B(2),C(5),C(10),C(12) '01/01/13,
Robert Nieminen,P.E. Signed/Sealed Calculations 13(1),13(5)through 13(8),C(3), 12/15/16
C(4),C(6)through C(9),C(I 1),
D(1)through D(7)
NOA No.:20-0723.28
Mi 1AAue�DL Expiration Date:01/02/23
Approval Date:09/17/20
Page 10 of 49
I
APPROVED ASSEMBLIES:
Membrane Type: APP Modified
Deck Type 2I: Steel,Insulated
Deck Description: - 22 ga.,Type B,Yield Strength 46 ksi,steel deck is secured at 6 ft.o.c.spans with Tek/5
fasteners spaced 6"o.c. Side-laps are secured with Tek/1 fasteners at 18"O.C.
This Tested Assembly has been analyzed for allowable'deck stress. See Evidence
Submitted Table.
System Type B(1): Base layer of insulation mechanically fastened,top layer adhered with approved Jsphalt.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Laver Insulation Fasteners fastener
able 3 Density/ft2
ACFoam-II,ACFoam_-IIi,F1intBoard ISO,FlintBoard ISO Cold,H-Shield;FlintBoardH ISO
Minimum 1.5"thick 15,19 1:1.45 ftz
Note: Base layer shall be mechanically attached with fasteners and density described., Insulation panels listed
are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall]be
increased maintaining the same fastener density(See Roofing Application Standard RAS 117 for fastening
details).
Top Insulation Laver Insulation Fasteners Fastener
able 3 Densi /fe
AC Foam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,FlintBoardn ISO
Minimum 1.5"thick N/A N/A
Note: Top layer of insulation shall be adhered with Millennium One'Step Foamable Adhesive,Millennium One '
Step Green Foamabie Adhesive or Millennium PG-1 Low Viscosity Insulation Adhesive in 0.75 inch ribbons
spaced 11 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment:Composite
insulation boards used as a top layer shall be installed with the polyisocyanurate face down.
Base Sheet: Oneply of Black Diamond Base Sheet or Flintlastic Ultra"Glass SA,self-adheredjto the
insulated substrate.
Ply Sheet: One or more plies of Flintlastic APP•Base T or Flintlastic STA,torch adhered to base sheet.
(Optional) j
Membrane: One ply of Flintlastic GTA,or Flintlastic GTA-FR,torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table'4. .
(Optional)
Maximum Design 45,psf(See General Limitation#7.)
Pressure:
NOA No.:20-0723A
'nE Expiration Date:01/02/23
Approval Date:09/17/20
Page 11 of 49
Membrane Type: SBS Modified
Deck Type 2I: SteeI,Insulated
Deck Description: 18-22 ga.,Type B,Grade 33 steel deck is secured at 6 ft.o.c.spans with ICH Traxx/5
fasteners spaced 6"o.c. Side laps are secured with three ICH Traxx/1 fasteners spaced 24"
O.C.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type B(2)-. Base layer of insulation mechanically fastened,top layer adhered with approved asphalt.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft'
ACFoam-II,ACFoam-III,F1intBoard ISO,FlintBoard ISO Cold,ENRGY 3,ISO 95+GL,H-Shield,
FlintBoardH ISO
Minimum 2.0"thick 1,2,6,7,15,12,19,20 1JA5 fe
Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed
are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density(See Roofing Application Standard RAS 117 for fastening
details).
_Ton Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft?
SECUROCK Gypsum-Fiber Roof Board
Minimum 114"thick N/A N/A
I
Note: Top layer of insulation shall be adhered with Insta Stik Quik Set Insulation Adhesive,OMG OlyBond 500
Adhesive,OMG OlyBond 500 Green Adhesive,ICP Adhesive CR-20,Millennium One Step Foamable Adhesive,
Millennium One Step Green Foamable Adhesive or Millennium PG-1 Low Viscosity Insulation Adhesive in 0.75
inch ribbons spaced 12 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face
down.
` Base Sheet: One ply of Flintlastic Ultra Glass SA,self-adhered to insulated substrate.
Membrane: One ply of Flintlastic Cap 30,Flintlastic FR Cap 30,Flintlastic FR Dual Cap,Flintlastic FR P,
Flintlastic GMS,or Flintlastic Premium FR-P adhered to base sheet with approved mopping
asphalt applied in full coverage at a rate of 20-25 lb/sq.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf(See General Limitation#7)
Pressure:
i
C
NOA No.:20-0723.28
Muaat�naoecOuarry Expiration Date:-0723.28
Approval Date:09/17/20
Page 12 of 49
fy
Membrane Type: APP Modified
Deck Type 2I: Steel,Insulated
Deck Description: 18-22 ga.steel
System Type B(3): Base layer of insulation mechanically fastened,optional top layer adhered with appr'ved
asphalt.
.All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Laver Insulation Fasteners F istener
Table 3 Density/ft2
ACFoam-II,ACFoam-III,F1intBoard ISO;FlintBoard ISO Cold;H-Shield,FlintBoardn ISO'
Minimum 1.5"thick 1,2,6,7,12,20 1:2 ft2
Minimum 2"thick 1,2,6,7,'12,20 1r'3.2 ft2
ENRGY 3,ENRGY 3 25 PSI
Minimum 1.4"thick 1,2,6,7,12,20 1:2 ft2
Minimum 2"thick 1,2,6,7,12,20 1:3.2 ft2
FescoBoard
Minimum 3/"thick 1,2,6,•7 12 20 1i:2 ft2
Structodek High Density Fiberboard Roof Insulation 1
Minimum'/2"thick 1,2,6,7,12,20 1 12 ft2
DensDeck,DensDeck Prime
Minimum%"thick 1,2,6,7,12,20. 1-2 ft2
Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed
are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall be
increased maintaining the same,fastener density(See.Roofing Application Standard RAS 117 for fastening
details).
Top Insulation Laver(Optional) Insulation Fasteners Fastener-
able 31 Density/ft2
Any of the insulations listed for'Base Layer,above.
Minimum See Base Layer, N/A N/A
Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a
rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down.
I
ruArnaae couKrr NOA No.:210-0723.28
PROVE Expiration Date•01/02/23'
Approval Date.•09/17/20
Page 13 of 49
i
I
i
Base Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet,
Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the insulated substrate with approved
mopping asphalt applied within the EVT range and at a rate of 20-40.
V
Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
(Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or,
one or more plies of Flintglas Ply 4 or Flintlglas Premium Ply 6 adhered to base sheet with
approved mopping asphalt applied within the EVT range and at a rate of 20-401bs./sq.or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic
STA or Flintlastic APP Base T torch adhered torch adhered to base sheet.
Membrane: Flintlastic GTA,or Flintlastic GTA-FR torch adhered to base or ply sheet.
Surfacing: . Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -45 psf.(See General Limitation#9)
Pressure:
i
I
I
i
,I
i
NOA No.:20-0723.28
MIAMFQAO+COUNTY11111 Expiration Date:01/02/23
Approval Date:09/17/20
Page 14 of 49
I
Membrane Type: SBS Modified j
Deck Type 2I: Steel,Insulated
Deck Description: 18-22 ga.steel
System Type B(4): Base layer of insulation mechanically fastened,optional top layer adhered with approved
asphalt.
All General and System Limitations apply.
One or more layers of any of the following insulations.
' I
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Densi /ft2
i
ACFoam-II,ACFoam-III,FlintBoard ISO,F1intBoard ISO Cold,H-Shield,FlintBoardn ISO
Minimum 1.5"thick 1,2,6,7,12,20 1:2 ftz
Minimum 2"thick 1,2,6,7,12,20' 1:3.2 ftz
ENRGY 3,ENRGY 3 25 PSI
Minimum 1:4"thick 1,2,6,7,.12,20 1:2 ftz
Minimum 2"thick 1,2,6,7,12,20 1 3.2 ftz
FescoBoard
Minimum%11 thick 1,2,6,7,12,20 1:2 ftz
Structodek High Density Fiberboard Roof Insulation
Minimum%"z thick 1,2,6,7,12,20 1:2 ftz
DensDeck,DensDeck Prime
Minimum'/a"thick 1,2,6,7,12,20 1:2 ftz
i
Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed
are minimum sizes and dimensions;'if larger panels are used the number of fasteners per board shall be
increased maintah.ing the same fastener density(See Roofing Application Standard RAS 117 for fastening
details).
Top Insulation Laver(Optional) Insulation Fasteners Fastener
Table 3 Density/fe
i
Any of the insulations listed for Base Layer,above.
Minimum See Base Layer• N/A N/A
Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a
rate of 2040 lbs/100 W. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down.
I
. I
NOA No.:20-0723.28
Expiration Date:01/02/23
Approval Date:09/17/20
Page 15 of 49
I
Base Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet,
Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the insulated substrate with approved
mopping asphalt applied within the EVT range and at a rate of 20-40.
Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
(Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or
one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with
approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base sheet or
one ply of Flintlastic Ultra Poly SMS Base Sheet torch applied to base sheet.
Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic Flintlastic Premium FR-P,
Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq.or Flintlastic FR Cap 30
T torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -45 psf.(See General Limitation#9)
Pressure:
• I
i
I
I
i
f
1
NOA No.:'20-0723.28
APPROVED_I -A'MIAMNDADE courrTY Expiration Date:01/02/23
Approval Date:09/17/20
Page 16 of 49
I
Membrane Type: APP Modified
I
Deck Type 2I: Steel,Insulated I
Deck Description: 18-22 ga.,Type B,Grade 33 steel deck is secured at 5 ft:o.c.spans with 5/8"paddle welds
with weld washers or with Teks 4 fasteners spaced 6"o.c.Side laps are secured with Teks 1
fasteners at 30"o.c
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type B(5): Base layer of insulation mechanically fastened,top layer adhered with approved asphalt.
All General and System Limitations apply.
iI One or more layers of any of the following insulations. 1
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ff
ACFoam-11,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,ENRGY 3,Multi-Max FA-3,H-Shield,
F1intBoardu ISO
Minimum 1.5"thick 1,2,6,7,12,20 1:1.33 ftz
Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed
are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density(See Roofing Application Standard RAS 117 for fastening
details). r
Tou Insulation Laver Insulation Fasteners Fastener
able 3 Density/fF
FescoBoard
Minimum 3/"thick N/A !N/A
Structodek High Density Fiberboard Roof Insulation
Minimum%"thick N/A N/A
Note: Top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20-
40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment.Composite
insulation boards used as a top layer shall be installed with the polyisocyanurate face down.
Base Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet,
Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the insulated substrate with approved
mopping asphalt applied within the EVT range and at a rate of 20401bs./sq.
Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
(Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or
one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a
full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base
sheet or Flintlastic STA or Flintlastic APP Base T torch adhered to base sheet.
Membrane: One ply of Flintlastic GTA,or Flintlastic GTA-FR torch adhered to base or ply sheet.
NOA No.:20-0723.28
MIAMMWECO= Expiration Date:01/02/23
Approval Date:09/17/20
Page 17 of 49
i
I
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
i
Maximum Design -52.5 psf.(For FescoBoard)(See General Limitation#7)
Pressure: -67.5 psf.(For Structodek High,Density Fiberboard Roof Insulation)(See General Limitation
#7)
i
I
i
{
i
I
I
I
I
1
I
I
1
I
NOA No.:20-0723.28
MIAMMECExpiration Date:01/02/23
Approval Date.'09/17/20
Page 18 of 49
I
mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq.or Flintlastic
FR Cap 30 T torch adhered to base or ply sheet. i
I
Surfacing: Any of the approved surfacing/coating options listed in Table 4'
(Optional) `
Maximum Design -52.5 psf.(For FescoBoard)(See General Limitation#7
) �
Pressure: -67.5 psf.(For Structodek High Density Fiberboard Roof Insulation)
(See General Limitation#7)
I
I
i
i
NOA No.:120-0723.28
CITA Lwe C4.7.1 Expiration Date:01/02/23
APPROVED Approval Date:09/17/20
Page 20 of 49
I
I
Membrane Type: APP Modified
Deck Type 2I: Steel,Insulated
Deck Description: 22 ga.,Type B,Yield Strength 46 ksi,steel deck is secured at 6 ft.o.c.spans with i ek/5
fasteners spaced 6"o.c. Side laps are secured with Tek/1 fasteners at 18"o.c. ,
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type B(7): Base layer of insulation mechanically fastened,top layer adhered with approved adhesive.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Density/fe
ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,FlintBoardH ISO
Minimum 1.5"thick 15,19 1:1.45 ff
Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density(See Roofing Application Standard RAS 117 for fastening
details).
Top Insulation Laver Insulation Fasteners Fastener
able 3 Density/ft'
SECUROCK Gypsum-Fiber Roof Board
Minimum 1/4"thick N/A 'N/A
Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive,Millennium One
Step Green Foamable Adhesive, Millennium PG-1 Low Viscosity Insulation Adhesive, Insta-Stik'Quik Set
Insulation Adhesive,OMG OlyBond 500 Adhesive or OMG OlyBond 500 Green Adhesive in 3/4"-1"wide beads
spaced 12 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T,torch adhered to the insulated'substrate.
Ply Sheet: One ply of Flintlastic STA or Flintlastic APP Base T,torch adhered to base sheet.
(Optional)
Membrane: One ply of Flintlastic GTA,or Flintlastic GTA-FR,torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
Maximum Design -75 psf(See General Limitation#7:)
Pressure:
NOA No.:20-0723.28
Miat� oecouttnr Expiration Date:01/02/23
Approval Date:09/17/20
Page 21 of 49
i
I
I
Membrane Type: SBS Modified.
Deck Type 2I: Steel Decks,Insulated
Deck Description: 22 ga.,Type B,Yield Strength 46 ksi,steel deck is secured at 6 ft.o.c.spans with Tek/5
fasteners spaced 6"o.c. Side laps are secured with Tek/1 fasteners at 24"o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type B(8): Base layer of insulation mechanically fastened,top layer adhered with approved adhesive.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft2
ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,FlintBoardH ISO
Minimum 1.5"thick 15,19 with 13,21 1:1.6 ft2
Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions;if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density(See Roofing Application Standard RAS 117 for fastening
details).
Top Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft'
SECUROCK Gypsum-Fiber Roof Board
Minimum 1/4"thick N/A N/A
Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive,Millennium One
Step Green Foamable Adhesive, Millennium PG-1 Low Viscosity Insulation Adhesive, Insta Stik ;Quik Set
Insulation Adhesive,OMG OlyBond 500 Adhesive or OMG OlyBond 500 Green Adhesive in 3/4"—1"wide beads
spaced 12 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Flintlastic Poly SMS Base,Flintlastic Ultra Poly SMS Base or Flintlastic Base 20
adhered to the insulated substrate with FlintBond Brush at a rate of 1.0-1.5 gal/sq.
Ply Sheet: One ply of Flintlastic-Poly SMS Base,Flintlastic Ultra Poly SMS Base or Flintlastic Base 20
(Optional) adhered to base sheet with Flintbond Brush at a rate of 1.0-1.5 gal/sq.
Membrane: One ply of Flintlastic FR Cap 30,Flintlastic FR-P,Flintlastic Premium FR-P or Flintlastic FR
Dual Cap adhered to base or ply sheet with FlintBond Brush at a rate of 1.0-1.5 gal/sq.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -75 psf(See General Limitation#7.)
Pressure:
I
NOA No.:20-0723.28
M� wAo Expiration Date:01/02/23
Approval Date:09/17/20
Page 22 of 49
I
I
i
Membrane Type: APP Modified
Deck Type 21: Steel Decks,Insulated
Deck Description: 18-22 ga.steel.
System Type C(1): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
I
Base Insulation Laver(Optional) Insulation Fasteners Fastener
Table 3 Density/fe
ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,ENRGY 3,ENRGY 3 25 PSI,H-Shield,
FlintBoardH ISO
Minimum 1.5"thick N/A N/A
Any Approved Perlite Insulation Listed in Table 2
Minimum 3/"thick N/A i N/A
Any Approved High Density Wood Fiberboard Listed in Table 2
Minimum''/z"thick N/A N/A
DensDeck,DensDeck Prime
Minimum%"thick N/A N/A
Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density.
Top Insulation Laver Insulation Fasteners Fastener
able 3 Density/W
Any Approved High Density Wood Fiberboard Listed in Table 2
Minimum'/z"thick 1,2,6,7,12,20 1:2 ftz
Any Approved Perlite Insulation Listed in Table 2
Minimum 3/<"thick 1,2,6,.7,12,20 1:2 ft2
DensDeck,DensDeck Prime
Minimum'/"thick 1,2,6,7,12,20 1:2 W
Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The
insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners
shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal
resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet,
Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the insulated substrate with approved
mopping asphalt applied within the EVT range and at a rate of 20-401bs./sq.
Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
(Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or
one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with
approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one
NOA No.:20-0723.28
Mart Expiration Date:01/02/23
Approval Date:09/17/20
Page 23 of 49
i
I
•
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic
STA or Flintlastic APP Base T torch adhered.
Membrane: Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet.
i
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design 45 psf.(See General Limitation#9)
Pressure:
i
I
I
i
i
I
M�a�f�aoE�otnvn NOA No.:20-0723.28
Expiration Date:01/02/23
Approval Date:09/17/20
Page 24 of 49
I
i
i
t i
Membrane Type: SBS Modified r
Deck Type 2I: Steel Decks,Insulated
Deck Description: 18-22 ga.steel.
System Type C(2): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Laver(Optional) Insulation Fasteners Fastener
Table 3 Density/W
ACFoam-II,ACFoam-III,FlintBoard ISO,F1intBoard ISO Cold,ENRGY 3,ENRGY 3 25 PSI,H-Shield,
FlintBoardn ISO
Minimum 1.5"thick N/A N/A
Any Approved Perlite Insulation Listed in Table 2
Minimum'/"thick N/A N/A
Any Approved High Density Wood Fiberboard Listed in Table 2
Minimum'/"thick N/A N/A
DensDeck,DensDeck Prime
Minimum'/"thick N/A N/A
Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density.
Top Insulation Laver Insulation Fasteners Fastener
able 3 Density/W
Any Approved High Density Wood Fiberboard Listed in Table 2
Minimum'/2"thick 1,2,6,7,12,20 1:2 ft-
Any Approved Perlite Insulation Listed in Table 2
Minimum'/"thick 1,2,6,7,12,20 1c2 ft2
DensDeck,DensDeck Prime
Minimum 1/"thick 1,2,6,7,12,20 1:2 ft'
Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The
insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners
shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal
resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment.
i
NAMWQA=E COUNTY
NOA No.:20-0723.28
Expiration Date'01/02/23
Approval Date:09/17/20
Page 25 of 49
I
I
i
I
Base Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet,
Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the insulated substrate with approved
mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
I
Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
(Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or
one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with
approved mopping asphalt applied within the EVT range and at a rate of 20-401bs.%sq.or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base sheet or
Flintlastic Ultra Poly SMS Base Sheet torch applied to base sheet. i
Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic FR-P,Flintlastic Premium
FR-P,Flintlastic Cap 30 or Flintlastic FR Cap 30, adhered to ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq.or Flintlastic
FR Cap 30 T torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4
(Optional)
Maximum Design -45 psf.(See General Limitation#9)
Pressure:
i
li
NOA No.:20-0723.28
JAPPM�AhtN�1 ROV ED I 7Y Expiration Date 01/02/23
Approval Date:09/17/20
Page 26 of 49
I
i
I
I
I
Membrane Type: SBS/APP Modified
Deck Type 2I: Steel,Insulated
Deck Description: Min.22 ga.,Type B,Yield Strength 50.6 ksi,steel deck is secured at 6 ft.o.c spans with 5/8"
diameter puddle welds spaced 6"o.c.Side laps are secured with Teks 1 fasteners at 118"O.C.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(3): All layers of insulation simultaneously attached.
Al1.General and System Limitations apply.
One or more layer.of any of the following insulations.
Base Insulation Laver(Optional) Insulation Fasteners Fastener
able 3 Density/fe
ACFoam-11,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold
Minimum 1.5"thick N/A - i N/A
Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density.
Top Insulation Laver Insulation Fasteners Fastener
able 3 Density/fe
ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold
Minimum 1.5"thick 12 with 13 or 20 with 21 1 1.78 W
Note: Top insulation layer shall be mechanically attached using the fastener density listed above.The insulation
panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners shall be
increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal resistance in
compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements.
Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA,self-adhered to the
insulated substrate.
Ply Sheet: One ply of Flintlastic Ultra Poly SMS Base Sheet,Flintlastic Base 20 T,Flintlastic'APP Base
(Optional) T or Flintlastic STA torch adhered to base sheet.
Membrane: Flintlastic FR Cap 30 T,Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply
sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -67.5 psf(See General Limitation V.)
Pressure:
NOA No::20-0723.28
rnwtwesoe.Dorm Expiration Date:01/02/23
�' Approval Date:09/17/20
Page 27 of 49
I
Membrane Type: APP Modified
Deck Type 2I: Steel,Insulated
Deck Description: 22 ga.,Type B,Yield Strength 46 ksi,steel deck is secured at 6 ft.o.c.spans with Tek/5
fasteners spaced 6"o.c. Side laps are secured with Tek/1 fasteners at 18"o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(4): All layers of insulation simultaneously attached.
i
All General and System Limitations apply.
One or more layers of any of the following insulations.
I
Base Insulation Layer Insulation Fasteners Fastener
Table 3 Density/ft'
ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,FlintBoardH ISO
Minimum 1.5"thick N/A N/A
Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density.
Top Insulation Laver Insulation Fasteners Fastener
able 3 Density/ft'
ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,F1intBoardu ISO
Minimum 1.5"th'-ck 15,19 1:1.45 ft-
Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The
insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners
shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal
resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA,self-adhered to the
insulated substrate.
Ply Sheet: One or more plies of Flintlastic APP Base T or Flintlastic STA,torch adhered to base sheet.
Membrane: One ply of Flintlastic GTA,or Flintlastic GTA-FR,torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -75 psf(See General Limitation#7.)
Pressure:
i
NOA No.:20-0723.28
ED M�a►awaoecov►rrr Expiration Date:01/02/23
__j APPROVED Approval Date:09/17/20
Page 28 of 49
I
I
I
Membrane Type: SBS/APP Modified
Deck Type 2I: Steel Decks,Insulated
Deck Description: 22 ga.,Type B,Grade 33,steel deck is secured 6 ft.o.c.spans with Teks 5 fastener's spaced 6"
o.c. Side laps are secured with Stitch Teks 1 fasteners spaced 24"o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table. 1
System Type C(5): Layer of insulation mechanically attached,optional thermal barrier loose laid.
All General and System Limitations apply.
I
Thermal Barrier: Min. '/4"thick DensDeck,SECUROCK Gypsum-Fiber Roof Board loose laid on deck.
(Optional)
One or more layers of any of the following insulations:
Insulation Laver Insulation Fasteners Fastener
Table 3 D'ensity/fe
ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,FlintBoardH ISO
Minimum 1.5"thick 15,16 with 18; 19,21 with 22 1:1.45 ft,
Note: Insulation layer shall be mechanically attached with fasteners and density described above. Insulation
panels listed are minimum sizes and dimensions;if larger panels are used the number of fasteners per•board
shall be increased maintaining the same fastener density(See Rooting Application Standard RAS 117 for
fastening details).
Base Sheet: One ply of Flintlastic Ultra Glass SA,self-adhered to the insulated substrate.
Membrane: One ply of Flintlastic FR Dual Cap,Flintlastic Cap 30,Flintlastic FR-P,Flintlastic GMS or
Flintlastic Premium FR-P adhered to base sheet with approved mopping asphalt applied in full
coverage at a rate of 20-25 lb/sq.or Flintlastic FR Cap 30 T torch adhered to base sheet.
Or
One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to base sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -75 psf See General Limitation#7.
Pressure:
i
i
I
i
=M1AAt*VMME§"
NOA No.:20-0723.28
Expiration Date:01/02i23
Approval Date:09/17/20
Page 29 of 49
' I
I
I
i
I
Membrane Type: APP Modified
Deck Type 2I: Steel,Insulated
Deck Description: 18-22 ga.,Type B,Grade 33,steel deck secured 6 ft.o.c.spans with puddle welds and
washers spaced 6"o.c. Side laps are secured with Teks 1 fasteners spaced 30"o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(6): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
i
Insulation Laver Insulation Fasteners Fastener
able 3 Density/fe
ACFoam-H,ACFoam-IH,FlintBoard ISO,FlintBoard ISO Cold,ENRGY 3,Multi-Max FA-3,H-Shield,
FlintBoardH ISO
Minimum 1.5"thick 2,5,9 1:1.33 ft2
Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The
insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners
shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117
for insulation attachment.
i
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to the
insulated substrate.
Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
(Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or
one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with
approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base sheet or
Flintlastic STA or Flintlastic APP Base T torch adhered to base sheet.
Membrane: One ply of Flintlastic GTA,or Flintlastic GTA-FR torch adhered to base or ply sheet'
i
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -82.5 psf(See General Limitation#7)
Pressure:
I
NOA No.:20-0723.28
M ;COU AM Expiration Date:01/02/23
Approval Date:09/17/20
Page 30 of 49
i
Membrane Type: SBS Modified j
Deck Type 2I: Steel,Insulated
Deck Description: 18-22 ga.,Type B,Grade 33,steel deck secured 6 ft.o.c.spans with puddle welds and
washers spaced 6"o.c. Side laps are secured with Teks 1 fasteners spaced 30"o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(7): All layers of insulation simultaneously attached.
All General and System Limitations apply.
1
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft'
ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,ENRGY 3,Multi-Max FA-3,H-Shield,
FlintBoardH ISO
Minimum 1.5"thick 2,5,9 1:.133 ftz
Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The
insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners
shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117
for insulation attachment.
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to the
insulated substrate.
Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
(Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or
one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with
approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base sheet or
Flintlastic Ultra Poly SMS Base Sheet torch applied to base sheet.
Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic FR-P,Flintlastic Premium
FR-P,Flintlastic Cap 30,Flintlastic FR Cap 30 or adhered to ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq.or Flintlastic
FR Cap 30 T torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf;with asphalt-applied cap membranes(See General Limitation#7)
Pressure: -82.5 psf;with torch-applied cap membranes(See General Limitation#7)
i
NOA No.:20-0723.28
Expiration Date.01/02/23
Approval Date-09/17/20
Page 31 of 49
I
I
Membrane Type: SBS/APP Modified
Deck Type 2I: Steel,Insulated
Deck Description: Min.22 ga.,Type B,Yield Strength 50.6,steel deck secured 6 ft.o.c.spans with 5%8"
diameter puddle welds spaced 6"o.c. Side laps are secured with Teks 1 fasteners spaced 18"
O.C.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
I
System Type C(8): All layers of insulation simultaneously attached.
I
All General and System Limitations apply.
One or more layers of any of the following insulations.
i
Base Insulation Laver(Optional) Insulation Fasteners Fastener
able 3 Density/ft'
SECUROCK Gypsum-Fiber Roof Board
.Minimum 0.5"thick N/A i N/A
Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density.
Top Insulation Laver Insulation Fasteners Fastener
able 3 De'nsity/ff
SECUROCK Gypsum-Fiber Roof Board
Minimum 0.5"thick 12 with 13 or 20 with 21 1.1.6 ft-
Note: Top insulation layer shall be mechanically attached using the fastener density listed above.The insulation
panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners shall be
increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal resistance in
compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements.
Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA,self-adhered to the
insulated substrate.
Ply Sheet: One ply of Flintlastic Ultra Poly SMS Base Sheet,Fhntlastic Base 20 T,Flintlastic APP Base
(Optional) T or Flintlastic STA torch adhered to base sheet.
Membrane: Flintlastic FR Cap 30 T,Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply
sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -82.5 psf(See General Limitation#7.)
Pressure:
rtiar�apnoecar�rr
NOA No.:20-0723.28
a Expiration Date:01/02/23
Approval Date:09/17/20
Page 32 of 49
i
Membrane Type: APP Modified
Deck Type 2I: Steel,Insulated
i
Deck Description: 22 ga.,Type B,Yield Strength 46 ksi,steel deck is secured at 6 ft.o.c.spans with Tek/5
fasteners spaced 6"o.c. Side laps are secured with Tek/l fasteners at 18"o.c. j
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
I
System Type C(9): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft'
ACFoam-II,ACF,)am-III,FlintBoard ISO,FlintBoard ISO Cold,H-Shield,FlintBoardH ISO
Minimum 1.5"thick N/A N/A
Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density.
Top Insulation Layer Insulation Fasteners Fastener
Table 3 Density/ft'
SECUROCK Gypsum-Fiber Roof Board j
Minimum 1/4"thick 15 with 13,19 with 21 1:1.45 ft2
Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The
insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners
shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal
resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T,torch adhered to the insulated substrate.
Ply Sheet: One ply of Flintlastic STA or Flintlastic APP Base T,torch adhered to base sheet.
(Optional)
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR,torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
Maximum Design -60 psf(See General Limitation V.)
Pressure:
I
MIAMWAOEGOt1N7Y
NOA No.:20-0723.28
Expiration Date:01/02/23
Approval Date:09/17/20
Page 33 of 49
I.
Membrane Type: SBS Modified
Deck Type 2I: Steel,Insulated
Deck Description: 18-22 ga.,Type B,Grade 80 steel deck is secured at 6 ft.o.c.spans with Traxx/5 screws and
3/4"diameter washers spaced 6"o.c. Side laps are secured with Traxx/1 screws spaced 12"
O.C.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(10): All layers of insulation simultaneously attached.
I
All General and System Limitations apply.
i
One or more layers of any of the following insulations.
Base Insulation Laver: Insulation Fasteners Fastener
Table 3 Density/ft2
H-Shield,FlintBoardn ISO,ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold
Minimum 1.5"thick N/A N/A
Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density.
Ton Insulation Laver: Insulation Fasteners Fastener
Table 3 Density/ft'
DensDeck Prime
Minimum%11 thick 12 with 13,20 with 21 1:1.33 ftz
Minimum'/z"thick 12 with 13,20 with 21 1:1 ft.
Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The
insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners
shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal
resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: Two or three plies of Glasbase Base Sheet,Flexiglas Base Sheet,Flintlastic Base 20,
Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet,Flintglas Ply 4 or
Flintglas Premium Ply 6 adhered to the insulated substrate with approved mopping asphalt
applied at a rate of 20 to 25 lbs./sq.
Ply Sheet: One ply of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with approved
mopping asphalt applied at a rate of 20 to 25 lbs./sq.
Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic FR-P,Flintlastic Premium
FR-P,Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered with approved mopping.asphalt
applied at a rate of 20 to 25 lbs./sq. i
MrAMFDADECoi7NiY NOA No.:20-0723.28
• Expiration Date:01/02/23
Approval Date 09/17/20
Page 34 of 49
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -112.5 psf(fastener density of 1:1.33 fe)(See General Limitation#7)
Pressure: -157.5 psf(fastener density of 1:1 if)(See General Limitation#7)
a
I
I
i .
I
}
I
G
I
I
i
I
I
I
NOA No.:20-0723.28
M�nttwwoecoutrnr Expiration Date 01/02/23
JAPPROVEDI_ Approval Date-., 09/17/20
Page 35 of 49
I
�I
Membrane Type: APP Modified
Deck Type 21: Steel,Insulated
1
Deck Description: 22 ga.,.Type F,Grade 80 steel deck is secured at 6 ft.o.c.spans with Tek/5 fasteners and 3/a"
washers per fixing point spaced 6"o.c. Side laps are secured with Tek/1 fasteners't 12"o.c.
This Tested Assembly has been analyzed for allowable deck stress. See E'videucc
Submitted Table.
System Type C(1'_): All layers of insulation simultaneously attached. 1
All General and System Limitations apply.
One or more layers of any of the following insulations.
i
Base Insulation Laver Insulation Fasteners Fastener
able 3 Density/ft'
ACFoam-H,ACFoam-III,FlintBoard ISO,FliutBoard ISO Cold,H-Shield,F1intBoardH ISO
Minimum 1.5"thick N/A N/A
Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density.
Top Insulation Laver Insulation Fasteners Fastener
Table 3 Density/fe
SECUROCK Gypsum-Fiber Roof Board
Minimum 1/4"thick 15 with 13,19 with 21 1:1 ft,
i
Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The
insulation panels li ted are minimum sizes and dimensions;if larger panels are used,the number of fasteners
shall be increased maintaining the-same fastener density.Insulation fasteners shall be tested for withdrawal
resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T,torch adhered to the insulated substrate.
Ply Sheet: One ply of Flintlastic STA or Flintlastic APP Base T,torch adhered to base sheet.
(Optional)
Membrane: One ply of Flintlastic GTA, or Flintlastic GTA-FR,torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
Maximum Design -120 psf(See General Limitation#7.)
Pressure:
i
ItI
l
NOA No.:20-0723.28
CDAUECOUNTY Expiration Date101/02/23
Approval Date:09/17/20
Page 36 of 49
i
Membrane Type: SBS Modified !
Deck Type 2I: Steel,Insulated
Deck Description: 18-20 ga.,Type B,Grade 80 steel deck secured at 6 ft.o.c.spans with Traxx/5 screws and%"
diameter washers spaced 6"o.c. Side laps are secured with Traxx/1 screws spaced]12"o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(12): All layers of insulation simultaneously attached.
I
All General and System Limitations apply.
I
One or more layers of any of the following insulations.
I
Base Insulation Laver: Insulation Fasteners Fastener
Table 3 Density/ftz
I
i
H-Shield,FlintBoardH ISO,ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold
Minimum 1.5"thick N/A N/A
Note: All layers shall be simultaneously fastened;see top layer below for fasteners and density.
Top Insulation Laer. Insulation Fasteners Fastener
Table 3 Density/W
SECUROCK Gypsum-Fiber Roof Board
Minimum%"thick 12 with 13,20 with 21 1:!1.33 ft-
Minimum%11 thick 12 with 13,20 with 21 1:1 ftz
Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The
insulation panels listed are minimum sizes and dimensions;if larger panels are used,the number of fasteners
shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal
resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: Two or three plies of Glasbase Base Sheet,Flexiglas Base Sheet,Flintlastic Base 20:
Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet,Flintglas Ply 4 or
Flintglas Premium Ply 6 adhered to the insulated substrate with approved mopping asphalt
applied at a rate of 20 to 25 lbs./sq.or Flintlastic Ultra Poly SMS Base Sheet torch applied to
the insulated substrate.
Ply Sheet: One ply of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet with approved
mopping asphalt applied at a rate of 20 to 25 lbs./sq.
Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic FR-P,Flintlastic Premium
FR-P,Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping
asphalt applied at a rate of 20 to 25 lbs./sq.
I
NOA No.:20-0723.28
JAPPMIAMFDADE COUN3Y .
R. Expiration Date:01/02/23
Approval Date:09/17/20
Page 37 of 49
Surfacing: Any of the approved surfacing/coating options listed in Table 4. +
(Optional) I
Maximum Design -157.5 psf(fastener density of 1:1.33 ft)(See General Limitation#7)
Pressure: -172.5 psf(fastener density of 1:1 ft)(See General Limitation#7)
1
I
I
I
I
i
I
i
I
I
I
I
I
I
I
i
NOA No.:20-0723.28
Mtnr�rwat�;�� Expiration Date:01/02/23
Approval Date:09/17/20
Page 38 of 49
Membrane Type: APP/SBS Modified
Deck Type 21: Steel,Insulated
Deck Description: 22 ga.,Type B,Yield Strength 49.3 ksi,steel deck secured at 6 ft.o.c.with Traxx/5I screws
spaced 6"o.c. Side laps are secured with Traxx/l screws spaced 24"o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table. j
System Type D(1): All layers of insulation and base sheet simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations. i
Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft,
ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold
I
Minimum 2.0"thick N/A ; N/A
I
Note: Insulation layer shall have preliminary attachment,prior to the installation of the base sheet at an
application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,and
four fasteners for any insulation board having no dimension greater than 5 ft. All layers of insulation and base
sheet shall be simultaneously fastened.See base sheet below for fasteners and density.
Base Sheet: One ply of Flintlastic Ultra Poly SMS Base Sheet mechanically attached as detailed in
Fastening below. Lap shall be heat welded.
i
Fastening#1: Trufast 415 EHD Fasteners or Trufast#21 SHD Fasteners with Trufast 2"Barbed Metal Seam
Plates,Trufast 2.4"Barbed Metal Seam Plates,Trufast 2.4"Scoop Seam Plates or Trufast 2-
3/4"Barbed Metal Seam Plates(EHD),FlintFast#15 EHD fasteners with FlintFast'2.4"
Barbed Seam Plates or FlintFast 2"Barbed Seam Plates spaced 12"o.c.in a 4"side lap. The
lap is heat welded closed encapsulating the fastener row.
*Steel deck is attached to structural supports with Traxx/5 screws(one screw per bearing
point).
(Maximum Design Pressure-52.5 psf,•See General Limitation#7.)
Fastening#2: Trufast#15 EHD Fasteners or Trufast#21 SHD Fasteners with Trufast 2.4"Scoop Seam
Plates or Trufast 2-3/4"Barbed Metal Seam Plates(EHD)or FlintFast#15 EHD fasteners
spaced 12"o.c. in a 4"side lap. The lap is heat welded closed encapsulating the fastener row.
*Steel deck is attached to structural supports with Traxx/5 screws(one screw per bearing
point).
(Maximum Design Pressure-67.5 psf,•See General Limitation#7.)
Fastening#3: Trufast#15 EHD Fasteners or Trufast#21 SHD Fasteners with Trufast 2.4"Scoop Seam
Plates or Trufast 2-3/4"Barbed Metal Seam Plates(EHD)or FlintFast#15 EHD fasteners
spaced 6"o.c.in a 4"side lap. The lap is heat welded closed encapsulating the fastener row.
*Steel deck is attached to structural supports with Traxxl5 screws with%"steel washers(one
screw/washer per bearing point).
(Maximum Design Pressure-112.5 psf,•See General Limitation#7.)
i
Miar��naoE cOUNSY NOA No.:20-0723.28
JAPPROVEDI__ Expiration Date:01/02/23
Approval Date:09/17/20
Page 39 of 49
Ply Sheet One ply of Flintlastic Ultra Poly SMS Base Sheet torch adhered to base sheet.
(Optional):
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR,torched-applied to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
• I
Maximum Design See Fastening Above.
Pressure:
i
I
I
I
i
i
t
NOA No.:20-0723.28
MIAMWAAPPROVED
TY Expiration Date:01/02/23
Approval Date:09/17/20
Plage 40 of 49
I
I
Membrane Type: APP Modified j
Deck Type 2I: Steel,Insulated
Deck Description: 18-22 ga.,(See Fastening Options Below)Type B,steel deck secured at 5 ft.o.c.spans with
Traxx/5 screws spaced 6"o.c. Side laps are secured with Traxx/1 screws spaced 26"o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type D(2): All layers of insulation and base sheet simultaneously attached.
All General and System Limitations apply. j
One or more layers of any of the following insulations.
I
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Densitv/ft2
ACFoam-H,ACFoam-III,FtintBoard ISO,FlintBoard ISO Cold,ENRGY 3,Multi Max FA-3,H-Shield,
F1intBoardu ISO or Any approved Polyisocyanurate Listed in Table 2
Minimum 1.5"thick N/A N/A
Top Insulation Laver(Optional) Insulation Fasteners Fastener
able 3 Density1W
Any Approved High Density Wood Fiberboard Listed in Table 2
Minimum%"thick N/A I N/A
I
Any Approved Perlite Insulation Listed in Table 2
Minimum'/4"thick NIA N/A
DensDeck,DensDeck Prime
Minimum%11 thick N/A N/A
Note: Top layer shall have preliminary attachment,prior to the installation of the base sheet at an application
rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,and four fasteners
for any insulation board having no dimension greater than 5 ft. All layers of insulation and base sheet,shall be
simultaneously fastened.See base sheet below for fasteners and density.
Base Sheet: One ply of Flexiglas Base Sheet,Glasbase Base Sheet*,Flintlastic Base 20,Flintlasltic Poly
SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet Base Sheet,Yosemite Venting Base
Sheet,or Flintlastic APP Base T**.mechanically attached as detailed in Fastening#1 below or
one ply of Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet Base
Sheet mechanically attached as detailed in Fastening#2 below.
*Not with use SFS Dekfast fastening components
**With use of SFS Dekfast fastening components
I
i
NOA No. 20-0723.28
rttArtwe►oecounmr Expiration Date:01/02/23
APPROVEDI Approval Date:09/17/20
Page 41 of 49
' j
Fastening#1: OMG#14 Roofgrip Fasteners and OMG 3"Round Metal Plates,Dekfast DF-#12-PH3 with
Dekfast PLT-H-2-7/8 plates,OMG#14 Roofgrip with 3 in.Ribbed Galvalume Plates,Flat
Bottom Plates,Trufast#14 HD Fastener with Trufast 3"Metal Insulation Plates or FlintFaat
#14 fasteners with F1intFast 3"Insulation Plates at a 4"side lap 6"o.c.and two rows
staggered in the center of the sheet,6"o.c.Min.Grade 33 steel deck. (Maximum Design
Pressure-67.S psf.;See General Limitation#7)
Fastening#2: OMG#14 Roofgrip Fasteners and OMG 3"Round Metal Plates,Dekfast DF-#12-PH3 with
Dekfast PLT-H-2-7/8 plates,OMG#14 Roofgrip with 3 in.Ribbed Galvalume Plates,Trufast
#14 HD Fasteners with Trufast 3"Metal Insulation Plates or F1intFast#14 fasteners with
F1intFast 3"Insulation Plates at a 4"side lap 12"o.c.and two rows staggered in the center of
the sheet, 12"o.c. 1
Min.Grade 80 steel deck. (Maximum Design Pressure-120 psf.;See General Limitation
#7)
Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
(Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or
one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq.or
one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base sheet
or Flintlastic STA or Flintlastic APP Base T torch adhered to base sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design See Fastening Above
Pressure:
i
i
I
I
I
NOA No.:20-0723.28
tgiattFoanEtourn r Expiration Date:01/02/23
g...O
Approval Date:09/17/20
Page 42 of 49
I
Membrane Type: SBS Modified
Deck Type 2I: Steel,Insulated
i
Deck Description: 18-22 ga.,(See Fastening Options Below)Type B,steel deck secured at 5 ft.o.c.spans with
Traxx/5 screws spaced 6"o.c. Side laps are secured with Traxx/I screws spaced 20"o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type D(3): All layers of insulation and base sheet simultaneously attached.
All General and S;stem Limitations apply.
One or more layers of any of the following insulations.
i
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft'
ACFoam-H,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,ENRGY 3,Multi Max FA-3,H-Shield,
F1intBoardH ISO or Any approved Polyisocyanurate Listed in Table 2
Minimum 1.5"thick N/A N/A
i
Ton Insulation Laver(Optional) Insulation Fasteners Fastener
Table 3 Density/ft'
Any Approved High Density Wood Fiberboard Listed in Table 2
Minimum%"thick N/A N/A
Any Approved Perlite Insulation Listed in Table 2
Minimum 3/a"thick N/A N/A
I
DensDeck,DensDeck Prime
Minimum'/a"thick N/A N/A
Note: Top layer shall have preliminary attachment,prior to the installation of the base sheet at an application
rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,and four fasteners
for any insulation board having no dimension greater than 5 ft. All layers of insulation and base sheet shall be
simultaneously fastened.See base sheet below for fasteners and density.
Base Sheet: One ply of Flexiglas Base Sheet,Glasbase Base Sheet*,Flintlastic Base 20,Flintlastic Poly
SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or Yosemite Venting Base Sheet
mechanically attached as detailed in Fastening#1 below or one ply of Flintlastic Poly SMS
Base Sheet or Flintlastic Ultra Poly SMS Base Sheet Base Sheet mechanically attached as
detailed in Fastening#2 below.
*Not with use SFS Dekfast fastening components
Fastening#1: OMG#14 Roofgrip Fasteners and OMG 3"Round Metal Plates,Dekfast DF412-PH3 with
Dekfast PLT-H-2-7/8 plates,OMG#14 Roofgrip with 3 in.Ribbed Galvalume Plates,
AccuTrac Flat Bottom Plates,Trufast#14 HD Fastener with Trufast 3"Metal Insulation Plates
or FlintFast#14 fasteners with F1intFast 3"Insulation Plates at a 4"side lap 6"o.c.and two
rows staggered in the center of the sheet,6"o.c.Min.Grade 33 steel deck. (Maximum
Design Pressure-67.5 psf.;See General Limitation#7)
Fastening#2: OMG#14 Roofgrip Fasteners and OMG 3"Round Metal Plates,Dekfast DF-#12-PH3 with
Dekfast PLT-H-2-7/8 plates,OMG#14 Roofgrip with 3 in.Ribbed Galvalume Plates,Trufast
MIAMFDADE CQl1N7Y
NOA No. 20-0723.28
Expiration Date:01/02/23
Approval Date:09/17/20
Page 43 of 49
1
414 HD Fastener with Trufast 3"Metal Insulation Plates,or Flintgaat#14 fastenersi with
FlintFaat 3"Insulation Plates at a 4"side lap 12"o.c.and two rows staggered in the'center of
the sheet, 12"o.c. f
Min.Grade 80 steel deck. (Maximum Design Pressure-120 psf.;See General Limitation
#7)
Ply Sheet: One ply of All Weather/Empire Base Sheet,Glasbase Base Sheet,Flexiglas Base Sheet,
(Optional) Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet or
one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-401lis./sq.or
one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to base sheet
or Flintlastic.Ultra Poly SMS Base Sheet torch applied to base sheet. +;
Membrane: One ply of Flintlastic GMS,Flintlastic FR Dual Cap,Flintlastic FR-P,Flintlastic Premium
FR-P,Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq.or Flintlastic
FR Cap 30 T torch adhered to base or ply sheet.
i
i
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design See Fastening Above
Pressure:
I
i
I
i
a
I
t
1
I
1
i
Muu�Ga�►oecouH7�r NOA No.:20-0723.28
P P R ) Expiration Date:01/02/23
Approval Date:09/17/20
Page 44 of 49
I
Membrane Type: APP/SBS Modified
Deck Type 2I: Steel,Insulated
i
Deck Description: 18-22 ga.,Type B,Grade 80,steel deck secured at 5 ft.o.c.spans with Traxx/5 screws spaced
6"o.c. Side laps are secured with Traxx/1 screws spaced 20"o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type D(4): ' All layers of insulation and base sheet simultaneously attached.
I
All General and System Limitations apply.
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
Table 3 D'ensity/ft'
ACFoam-II,ACFoam-III,FlintBoard ISO,FlintBoard ISO Cold,ENRGY 3,Multi Max FA-3,H-Shield,
FlintBoardu ISO or Any approved Polyisocyanurate Listed in Table 2
Minimum 1.5"thick N/A N/A
Note: Insulation layer shall have preliminary attachment,prior to the installation of the base sheet at an
application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,and
four fasteners for any insulation board having no dimension greater than 5 ft. All layers of insulation;and base
sheet shall be simultaneously fastened.See base sheet below for fasteners and density. 1
I
Base Sheet: One ply of Flintlastic Ultra Poly SMS Base Sheet Base Sheet mechanically attached as
detailed in Fastening below. Lap shall be heat welded.
Fastening#1: Trufast#15 EHD Fasteners with Trufast 2.4"Barbed Metal Seam Plates or FlintFast#15 EHD
fasteners with F1intFast 2.4"Barbed Seam Plates spaced 12"o.c.in a 4"side lap. The lap is
heat welded closed encapsulating the fastener row.
Membrane: One ply of Flintlastic GTA,Flintlastic GTA-FR or Flintlastic FR Cap 30 T torch adhered to
base sheet.
I
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -60 psf.(See General Limitation#7)
Pressure:
i
I
i
NOA No.:20-0723.28
,RAM; -1A 0lJ 91 a# Expiration Date:01/02/23
Approval Date:09/17/20
'Page 45 of 49
i
I
Membrane Type: SBS Modified
i
Deck Type 2I: Steel,Insulated
Deck Description: Min.22 ga.,Type B,Yield Strength 50.6 ksi,steel deck secured at 6 ft.o.c.spans with 5/8"
diameter puddle welds spaced 6"o.c. Side laps are secured with Teks 1 fasteners spaced 18"
O.C. I
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type D(5): All layers of insulation and base sheet simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft'
Any Approved Polyisocyanurate Listed in Table 2
Minimum 1.0"thick N/A N/A
Note: Insulation layer shall have preliminary attachment,prior to the installation of the base sheet at an
application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,and
four fasteners for any insulation board having no dimension greater than 5 ft. All layers of insulation"and base
sheet shall be simultaneously fastened.See base sheet below for fasteners and density.
Base Sheet: One ply of Glasbase Base Sheet,Flexiglas Base Sheet,Flintlastic Base 20,Yosemite Venting
Base,Flintlastic Poly SMS Base and Flintlastic Ultra Poly SMS Base,mechanically attached
as described below.
Fastening#1: Trufast#14 HD Fasteners with Trufast 3"Metal Insulation Plates,F1intFast#14 fasteners with
FlintFast 3"Insulation Plates spaced 6"o.c.at the 4"wide laps and 12"o.c.in three,equally
spaced staggered center rows.
Ply Sheet: One ply of Flintlastic Base 20,Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS
(Optional) Base Sheet applied in F1intBond Brush at a rate of 1—1.5 gal/sq to base sheet.
Membrane: One ply of Flintlastic Cap 30,Flintlastic FR Cap 30,Flintlastic FR Dual Cap,Flintlastic FR-
P,Flintlastic Premium FR-P or Flintlastic GMS applied in FlintBond Brush at a rate of I—4.5
gal/sq to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -75 psf.(See General Limitation#T)
Pressure:
i
I
IE
f
Mtartwauecourm NOA No.:20-0723.28
•+ + Expiration Date:01/02/23
Approval Date:09/17/20
i Page 46 of 49
I
f
Membrane Type: SBS Modified j
Deck Type 2I: Steel,Insulated ,
Deck Description: 18-22 ga.,Type B,Grade 80,steel deck secured at 5 ft.o.c.with Traxx/5 screws sp�ced 6"
o.c. Side laps are secured with Traxx/1 screws spaced 20"o.c. I
This Tested Assembly-has been analyzed for allowable deck stress. See Evidence
Submitted Table. j
System Type D(6,,: All layers of insulation and base sheet simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
1
Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft'
Any Approved Polyisocyanurate listed in Table 2
Minimum 1.5"thick N/A N/A
Note: Insulation layer shall have preliminary attachment,prior to the installation of the base sheet at an
application rate of two fasteners per board for insulation boards having no dimension greater than 4 it.,and
four fasteners for any insulation board having no dimension greater than 5 ft. All layers of insulation and base
sheet shall be simultaneously fastened.See base sheet below for fasteners and density.
Base Sheet: One ply of Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet Base
Sheet mechanically attached as detailed in Fastening below.
Fastening#1: OMG#14 Roofgrip Fasteners and OMG 3"Round Metal Plates,Dekfast DF-912-PH3 with
Dekfast PLT-H-2-7/8 plates,OMG#14 Roofgrip with 3 in.Ribbed Galvalume Plates,Trufast
#14 HD Fastener with Trufast 3"Metal Insulation Plates or FlintFast#14 fastener's with
F1intFast 3"Insulation Plates spaced 12-inch o.c.in the 4-inch wide lap and 12-inch o.c.in
two equally spaced staggered rows in the field.
Ply Sheet: One ply of Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base Sheet,torch adhered to
(Optional) base sheet.
Membrane: One ply of Flintlastic FR Cap 30 T,torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -112.5 psf.(See General Limitation 97)
Pressure:
j
I
NOA No.:20-0723.28
'MtAMHMME ff Y T Expiration Date:01/02/23
Approval Date:09/17/20
i Page 47 of 49
I
I
Membrane Type: APP/SBS Modified
Deck Type 2I: Steel,Insulated
Deck Description: Min.22 ga.,Type B,Grade 80,steel deck secured at 6 ft.o.c.with Traxx/5 screws with 3/4"
steel washers(two screws/washers per bearing point)spaced 6"o.c.. Steel side laps are
secured with Traxx/I fasteners spaced 24"o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type D(7): All layers of insulation and base sheet simultaneously attached.
i
All General and System Limitations apply. +
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
Table 3 D'ensity/ft2
ACFoam-II,ACFoam-III,FlintBoard ISO,F1intBoard ISO Cold
Minimum 2.0"thick N/A N/A
Note: Insulation layer shall have preliminary attachment,prior to the installation of the base sheet at an
application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,and
four fasteners for any insulation board having no dimension greater than 5 ft. All layers of insulation:and base
sheet shall be simultaneously fastened.See base sheet below for fasteners and density.
Base Sheet: One ply of Flintlastic Ultra Poly SMS Base Sheet Base Sheet mechanically attached as
detailed in Fastening below. Lap shall be heat welded.
Fastening#1: Trufast#15 EHD Fasteners or Trufast#21 SHD Fasteners with Trufast 2.4"Scoop Seam
Plates or Trufast 2-3/4"Barbed Metal Seam Plates(EHD)or FlintFast#15 EHD fasteners
spaced 6"o.c.in a 4"side lap. The lap is heat welded closed encapsulating the fastener row.
Ply Sheet One ply of Flintlastic Ultra Poly SMS Base Sheet torch-applied to base sheet.
(Optional):
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch-applied to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -165 psf.(See General Limitation#7.)
Pressure:
i
i
I
I
. i
NOA No.:20-0723.28
Expiration Date:01/02/23
E Pal
Approval Date:09/17/20
Page 48 of 49
i
STEEL DECK SYSTEM LIMITATIONS:
1. If mechanical attachment to the structural deck through the lightweight insulating concrete is propos i ed, a field
withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density.
All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing
Application Standard RAS 117,calculations shall be signed and sealed by a Florida registered Professional Engineer,
Registered Architect or Registered Roof Consultant,
2. For steel deck application where specific deck construction is not referenced: The deck shall be a minimum 22 gage
attached with 5/8"puddle welds with weld washers at every flute with maximum deck spans of 5 ft.o.c.
GENERAL LIMITATIONS:
I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate.of 2040 lbs./sq.or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment: When applied in approved asphalt,panel size
shall be 4'x 4'maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped.If no recovery board is used the base sheet shall be applied using spot mopping
with approved asphalt, 12"diameter circles,24"o.c.;or strip mopped 8"ribbons in three rows,one at each side lap
and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not
acceptable. A 6"break shall be placed every 12'in each ribbon to allow cross ventilation. Asphalt application of
either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. j
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf.,as
tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested,are below
275 Ibf.insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing,
prepared,signed and sealed by a Florida registered Professional Engineer,Registered Architect or Registered Roof
Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken
from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard
RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer,
Registered Architect or Registered Roof Consultant(When this limitation is specifically referred within this NOA,
General Limitation#9 will not be applicable.)
8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to
Roofing Application Standard RAS 11 I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e.field,
perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones(i.e.perimeters,extended comers and corners).(When this limitation is specifically
referred within this NOA,General Limitation#7 will not be applicable.) '
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
I
NOA No.:20-0723.28
rut►�tNoao; Expiration Date:01/02/23
Approval Date:09/17/20
Page 49 of 49
I