Loading...
HomeMy WebLinkAboutGrande Roofing info Sheet.pdf(1)L, LL:1L0-2 WAR- - P L L Lc` ' o ti � ST. LUCE ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D 1,2,3,4,5,6.7' Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1, Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form Roof1nfoFeb21 Rev Feb 18, 2021 ST.� L.IJCIE - Master Permit No. ❑ Low Slope VASphaltic Shingles rd New roof O Repair Low Slope Roof Area (SF) Section A (General Information) ROOF CATEGORY O echa . Ily Fastened Tile Metal Pan Shingles 0 Prescriptive BUR-RAS 150 ROOF ROOF TYPE. 0 Maintenance Process No. 0 Mortar/Adhesive Set Tiles DWood Shingles/Shakes Reroofing . ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) 174O$3 ❑ Recovering Total (SF) &93 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST-O'LUCIE Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Matg(rial: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding M terial: Top Insulation Layer: Top Insulation Size and Thic/ing : Top Insulation Fastener/BoMaterial: Base Sheet(s) & No. of Base Sheet Fastener/9 Ply Sheet(s)' & No Ply Sheet Faste Top Ply: s): ing Material: /of Ply(s): /Bonding Material: Top Ply Vastener/Bonding Material: Surfacing: Fastener Spacing for An or/Base Sheet Attachment: Zone 1'• -" oc ap, # Rows_ @ 000 Zone 1: " oc Lap, # Rows @ "oo Zone 2: " c @ Lap, # Rows @ " oc Zone 3: oc @ Lap, # Rows- @ "ac Numb of Fasteners Per Insulation Board: Zo 1': Zone 1: Zone 2: Zone 3: lustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc.. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. STz LIUC I E 0 Section D (Steep Slope Roof System) Roof System Manufacturer: ;,Fr -�rar�e Notice of Acceptance Number: FL - Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculptions): .Zone 1:— 4 � Zone 2e:Zone 2n:Zone 2r:`1 Zone 3eZone 3r: s f2$ Deck Type: Type Underiayment: bW4tawS-5 t=iS Roof Slope: 12 Insulation: VV Fire Barrier: f Ridge Venti lion? Fastener Type & Spacing: D Adhesive Type: ed _ Type Cap Sheet: N X Mean Roof Height: - Roof Covering:Ifw"- 6--V Type & Sipe Drip Edge: