Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Window system Detail
GENERAL NOTES: SS-3520 IMPACT -RESISTANT STOREFRONT WINDOW SYSTEM GENERAL NOTES: 1. THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FBC, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 2. SHUTTERS ARE NOT REQUIRED PER FBC REQUIREMENTS, WHEN USED IN WIND-BORNE DEBRIS REGIONS. 3. GLAZING: SEE GLAZING DETAILS ON SHEET 6 & GLAZING TYPES ON SHEET 8. 4. DESIGN PRESSURES: A) NEGATIVE DESIGN LOADS BASED ON STRUCTURAL & CYCLE TESTING AND GLASS PER ASTM E1300. B) POSITIVE DESIGN LOADS BASED ON WATER INFILTRATION, STRUCTURAL & CYCLE TESTING AND GLASS PER ASTM E 1300. C) DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN, ASD. 5. THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33-1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD. 6. INSTALLATION SCREWS & FRAME CORNERS TO BE SEALED WITH NARROW JOINT SEALANT. 7. DISSIMILAR MATERIALS THAT COME INTO CONTACT, INCLUDING PRODUCT FRAMING, ANCHORAGE AND OPENING SUBSTRATES, SHALL BE COATED OR PROTECTED TO PREVENT CORROSIVE REACTIONS AS REQUIRED BY THE FLORIDA BUILDING CODE. 8. REFERENCES: ELCO ULTRACON & CRETEFLEX NOA'S, ITW TAPCON NOA ANCHOR NOTES: 1. FOR CONCRETE/CMU SUBSTRATE APPLICATIONS IN MIAMI-DADE COUNTY, USE ONLY MIAMI-DADE COUNTY APPROVED ELCO ANCHORS. SEE TABLE 1 ON THIS SHEET FOR EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS. 2. FOR SUBSTRATE APPLICATIONS SEE TABLE 1 ON THIS SHEET. 3. WOOD BUCKS DEPICTED AS 1X ARE LESS THAN 1-1/2" THICK. PROPERLY SECURED, 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE OR CMU. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD & TO BE REVIEWED BY THE BUILDING OFFICIAL. 4. SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. WOOD BUCKS, BY OTHERS, MUST BE SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY THE WINDOW. 5. METAL SUBSTRATE TO MEET MIN. STRENGTH AND THICKNESS REQUIREMENTS PER THE FBC AND TO BE REVIEWED BY THE AUTHORITY HAVING JURISDICTION. INSTRUCTIONS: 1. DETERMINE THE BUILDING'S REQUIRED DESIGN PRESSURE USING THE ASCE 7 STANDARD. THE PRODUCT'S DESIGN PRESSURE MUST MEET OR EXCEED THIS VALUE. 2. DETERMINE THE ANCHOR TYPE FROM TABLE 1, SHEET 1. 3. DETERMINE THE GLASS DESIGN PRESSURE FROM TABLE 2. 4. MID -PANEL ANCHOR QUANTITIES ARE GIVEN IN TABLES 7 & 8 AND HAVE BEEN CALCULATED FOR THE PRODUCT'S MAXIMUM DP. 5. IF THE STOREFRONT WINDOW IS ATTACHED TO ANOTHER WINDOW THROUGH A COMMON MULLION: A) DETERMINE THE MULLION DESIGN PRESSURE FROM TABLE 9. B) DETERMINE THE MAXIMUM DESIGN PRESSURE DUE TO MULLION CLUSTER ANCHORAGE FROM TABLES 3 OR 4 BASED ON YOUR SHIM SPACE, ANCHOR TYPE AND THE QUANTITY OF ANCHORS. 6. IF THE JAMBS ARE ANCHORED TO THE SUBSTRATE: A) THE SPACING IS GIVEN IN TABLES 5 & 6 AND HAVE BEEN CALCULATED FOR THE PRODUCT'S MAXIMUM DP. IF THE JAMBS ARE ANCHORLESS: A) DETERMINE THE MAXIMUM DESIGN PRESSURE DUE TO CLUSTER ANCHORAGE FROM TABLES 3 OR 4 BASED ON YOUR SHIM SPACE, ANCHOR TYPE AND THE QUANTITY OF ANCHORS. B) DETERMINE THE JAMB DESIGN PRESSURE FROM TABLE 9. 7. THE LOWEST DESIGN PRESSURE FROM ALL TABLES REFERENCED ABOVE, SHALL BE USED FOR THE ENTIRE ASSEMBLY. 8. IF COMBINED WITH A COMPATIBLE STOREFRONT ENTRANCE DOOR, THE LESSER DESIGN PRESSURE OF THE DOOR OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. FLORIDA PRODUCT APPROVAL # 26048 TABLE 1: IMPACT RATING RATED FOR LARGE & SMALL MISSILE IMPACT RESISTANCE Min. Edge Min. Min. O.C. Group Anchor Substrate I Distance Embedment Distance P.T. Southern Pine (SG=0.55) 1" 1-3/8" T. Aluminum, 6063-T5" #14 Steel or (0.125" min. thickness) 3/8" 1/8" 5/8" A 410 SS SMS (G5) Steel, A36* (0.125" min. thickness) 3/8" 1/8" 5/8" Steel Stud, A653 (0.045" min. thickness) 3/8" .045" 5/8" Concrete (min. 2.85 ksi) 2-1/2" 1-3/81, 3" Grout -Filled CMU, 1/4" Elco Ultracon (ASTM C-90) 2-1/2" 1-3/4" 4" Ungrouted CMU, (ASTM C-90) 2 1/2 1 1/4" 6" Concrete (min. 3.00 ksi) 2-112 1-3/4" 3" Concrete B 1/4" DeWalt (min. 3.00 ksi) 2-112" 1-3/8" 4" Ultracon+ Grout -Filled CMU, (ASTM C-90) 2-1/2" 1-3/4" 4" Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" 3" 1/4" Elco 410 S.S. Ungrouted CMU, CreteFlex (ASTM C-90) 2 1/2" 1 1/4" 6" Ungrouted CMU, 5/16" Elco Ultracon (ASTM C-90) 3 1/8" 1-1/4" U. 1/4" Elco 410 Concrete S.S. CreteFlex (min. 3.35 ksi) 2-1/2 1-3/4" 3" Concrete C (min. 3.52 ksi) 3-1/8" 2" 3" 5/16" Elco Ultracon Grout -Filled CMU, (ASTM C-90) 2 1/2 2 1/4" 5" Concrete 3/8" Large Diameter (min. 3 ksi) 3" 1-1/2" 4" D ITW Tapcon Ungrouted CMU, (ASTM C-90) 3" 1-1/2" 6" THIS SYSTEM HAS BEEN TESTED TO MEET THE 400 FT -LB KINETIC ENERGY IMPACT LOADING REQUIREMENTS OF ANSI Z97.1. CONTENTS: * MIN. OF 3 THREADS BEYOND THE METAL SUBSTRATE. METAL SUBSTRATE TO MEET MIN. STRENGTH AND THICKNESS REQUIREMENTS PER CURRENT FLORIDA BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING JURISDICTION. "UNGROUTED CMU" VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. ALL ANCHOR HEAD TYPES ARE ALLOWED GENERAL NOTES, INSTRUCTIONS ...................................... 1 ANCHOR TYPES, TABLE 1.....................................................1 ELEVATIONS......................................................................... 2, 3 5" HORIZ. SECTIONS, .... .................... ..................... ............. 4 7" HORIZ. SECTIONS.............................................................. 5 VERT. SECTIONS....................................................................6 INSERTS...................................................................................7 GLASS DP, TABLE 2 & GLAZING TYPES...............................8 MULLION ANCHOR CLUSTER DP - 1/4" SHIM, TABLE 3......9 MULLION ANCHOR CLUSTER DP - 1/2" SHIM, TABLE 4......10 JAMB ANCHOR SPACING - 1/4" SHIM, TABLE 5. .................. 11 JAMB ANCHOR SPACING - 1/2" SHIM, TABLE 6...................12 MID -PANEL ANCHOR QUANTIY - 1/4" SHIM, TABLE 7.........13 MID -PANEL ANCHOR QUANTIY - 1/2" SHIM, TABLE 8.........14 VERTICAL MULLION DP, TABLE 9.........................................15 EXTRUSION PROFILES.......................................................... 16 CORNER DETAILS.................................................................. 16 PARTS LIST, TABLE 10...........................................................16 ct b .'.4 , = z Rio 0 0 0w Z Of = ¢~o _jC ® OQ,Twc Z S c w` �cc) ¢� 0 w o _I � 2i>� z�� zo J } � Qom O c� J COz o=W W0L) w z L�> a-z L) ZYU o U) boo Op, =xsza U) Lu U X O _j LL In Cpcn 0KLu c>�!a �;o (� '0 U O Q N a� z 0 CD r J 0 0 Q Q uogdussa(j ADS U) 0 0 iz U) W �e T i1 0 LL i0 Un Vz Q 06 L U) LU G 0 'z J 0 75 U) U) 0 >Z_ z Iy ILL w 11 0 U) N 0 O i 11-41 LL C) N L0 M U) O,v IZI TLYN/V No. 5705 put ?3 9/22/20 «� STAVE OF r} . \ A. LYNN MILLER, P.E. P.E.# 58705 0 'N^ V M i U) MAX. O.C. DISTANCES REINFORCED & REINFORCED 5" MULLION UNREINF. 5" MULLION UNREINFORCED 7" HD MULLION 24" 14-3/8" 24" MAX. END DISTANCES REINFORCED & REINFORCED 5" MULLION UNREINF. 5" MULLION UNREINFORCED 7" HD MULLION 24" 12-7/8" 24" 180" MAX. A S FRAME 4 5 HEIGHT i SEE O.C. SPACING ON TABLES 5 & 6 6" MAX. SEE TABLES 7 SEE TABLES &8FOR 3&4FOR MID -PANEL CLUSTER ANCHOR ANCHOR QUANTITY QUANTITIES SEE TABLES 7 SEE TABLES SEE TABLES & 8 FOR 3 & 4 FOR & 8 FOR MID -PANEL CLUSTER MID -PANEL ANCHOR ANCHOR ANCHOR QUANTITY QUANTITIES QUANTITY 7 SEE STOREFRONT DOOR APPROVALFOR SPECIFICATIONS I I I I I I I I A REINFORCEMENT SEE TABLE 9 B T / 4 5 / B 1/4" NUT & BOLT, SEE SHEETS 4 & 5 / 6 4 MULTIPLE HORIZONTAL MULLIONS ALLOWED, 60" MAX. LENGTH / D 4 i r I ATTACHED COMPATIBLE STOREFRONT DOOR & TRANSOM, SEE SEPARATE APPROVALFOR SPECIFICATIONS ------------- _L_� -�I --I---------- - ------------ - iI U--lu ------ II --I I �--3-1/2" MAX. �J�_L) -- � ) I I SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE & 8 FOR 3 & 4 FOR & 8 FOR 3 & 4 FOR & 8 FOR STOREFRONT MID -PANEL CLUSTER MID -PANEL CLUSTER MID -PANEL DOOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR APPROVALFOR QUANTITY QUANTITIES QUANTITY QUANTITIES QUANTITY SPECIFICATIONS TYP. ELEVATION OF STOREFRONT WINDOW SYSTEM WITH EXAMPLES OF HORIZONTAL MULLION & STOREFRONT DOOR NOTES: 1. IF COMBINED WITH A COMPATIBLE STOREFRONT ENTRANCE DOOR, THE LESSER DESIGN PRESSURE VALUE OF THE DOOR OR THE WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. SEE TABLES FOR MAXIMUM ALLOWED SIZES. 3. SEE SHEET 8 FOR DAYLIGHT OPENING (DLO) FORMULAS. 180" MAX. FRAME HEIGF (DOOR MAY LIMIT MAX HEIGHT, SEE SEPARATE APPROVAL Cam'` ocEN$F rt� * : No. 58705 4'1'9/22/20 STATE OF 4/1 �pT F40RID , ONAL I \ A. LYNN MILLER, P.E. P.E.# 58705 SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES SEE TABLES 7 USE HALF THE & 8 FOR 3 & 4 FOR & 8 FOR 3 & 4 FOR & 8 FOR 3 & 4 FOR & 8 FOR 3 & 4 FOR & 8 FOR CLUSTER ANCHOR MID -PANEL CLUSTER MID -PANEL CLUSTER MID -PANEL CLUSTER MID -PANEL CLUSTER MID -PANEL QUANTITY SHOWN IN ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR TABLES 3 & 4 QUANTITY QUANTITIES QUANTITY QUANTITIES QUANTITY QUANTITIES QUANTITY QUANTITIES QUANTITY _76 I IIMIM 11 IF, 1 11 l� 1 �_L_ MAX. O.C. DISTANCES 24" MAX. REINFORCED UNREINF. REINFORCED & 5" MULLION 5" MULLION UNREINFORCED A 7" HD MULLION 24" 14-3/8" 24" REINFORCEMENT SEE TABLE 9 24" MAX. O.C. 1 MAX. END DISTANCES A S 4 5 REINFORCED UNREINF. REINFORCED & UNREINFORCED g 5" MULLION 5" MULLION 7" HD MULLION 24" 12-7/8" 24" II i � II IIII i� � �� IIII x II II A B T 4 5 OLT IF REINFORCEMENT IS REQUIRED, SEE SHEETS 4 & 5 �1/4" NUT & BOLT, SEE SHEETS 4 & 5 / REINFORCEMENT SEE TABLE 9 L---------------I 7 P 7 / / ATTACHED PTAC LOUVER, SEE SEPARATE APPROVALFORti SPECIFICATIONS Q 7 A S / H --- 6 -- ATTACHED 07 WINDOW, SEE SEPARATE APPROVAL FOR SPECIFICATIONS / O -- 6" MAX. L SEE O.C. SPACING M ON TABLES 5 & 6 7 -- -- ------------ - - - -----gB _I�___ KNEEWALL- OTHERS I u I I I I I J L — J L---- J L -- --------� 1 -- i L -------- I J --_j L--------J I f 6� USE HALF THE SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES 3 & 4 FOR CLUSTER ANCHOR & 8 FOR 3 & 4 FOR & 8 FOR 3 & 4 FOR & 8 FOR 3 & 4 FOR & 8 FOR CLUSTER ANCHOR QUANTITY SHOWN INMID-PANEL CLUSTER MID -PANEL CLUSTER MID -PANEL CLUSTER MID -PANEL QUANTITIES (SPLIT TABLES 3 & 4 ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR BETWEEN ADJOINING QUANTITY QUANTITIES QUANTITY QUANTITIES QUANTITY QUANTITIES QUANTITY WINDOWS) TYP. ELEVATION OF ANCHORLESS JAMB NOTES: 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. SEE TABLES FOR MAXIMUM ALLOWED SIZES. 3. AWNING WINDOW INSERT SHOWN BUT MAY BE ANY APPROVED PGT, CGI OR WINDOOR WINDOW WITH A FLANGED FRAME. 4. SEE SHEET 8 FOR DAYLIGHT OPENING (DLO) FORMULAS. 5. MULTIPLE INSERTS WITHIN THE SAME STOREFRONT WINDOW ALLOWED. TYP. ELEVATION OF STOREFRONT WINDOW SYSTEM WITH EXAMPLES OF WINDOW INSERT, PTAC INSERT & KNEEWALL SEE TABLES 7 & 8 FOR MID -PANEL ANCHOR QUANTITY 13-1/2" MAX. 1 6" MAX Q Aa y uoi}du�saa na y SEE O.C. SPACING ON TABLES 5 & 6 N O M U) O a}oa Q Q _j d J a H LL MDJa ' d: W C� U Vlo (n 6" MAX. y d 0 (n °o , W �- w ON Now Quo (n �MG Oil �M Q u'=M� U) Cfl ® O��cc Z�Qrn 0 0 w � O O O J c) y) M 00 >z aaaUS � U w v ZYCD cD �cn�� N m Z Z �lo� �N z�rn �0o� Z O a/as5 }�Lo O0w� 2 O QUv x°6za LL O 0M (Dcow� ¢ CV m z LL o LL Q W 0 LLI CCU) W M �L� o �a w W O U) Ofo U a F z aR�l ssaa saua5 YNNtij�l'% �10ENSF r� * : No. 58705 — 4'1'9/22/20 � STATE OF _ij ,pT FCORIOP �� , ONAL I I���� A. LYNN MILLER, P.E. P.E.# 58705 EMBEDMENT EDGE DISTANCE TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1. SHEET 1. CONCRETE/CMU PER ANCHOR REQUIREMENT, 2X WOOD BUCK OR WOOD FRAMING EXTERIOR 1/2" MAX. SHIM EMBEDMENT a4° EDGE DISTANCE' a 1 d � TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE e TABLE 1, SHEET 1. CONCRETE/CMU PER ANCHOR a REQUIREMENT 1/2" MAX. SHIM INSTALLATION NOTES: DETAIL Al INTO MASONRY OR WOOD REQUIRED AT EACH ANCHOR LOCATION, MIN. 3" LENGTH REINFORCEMENT 10 (IF REQUIRED) 8 1 DAYLIGHT OPENING WIDTH 40 OPTIONAL LAW IG GLASS 1X WOOD BUCKSTRIP, SEE NOTE 2. THIS SHEET. DETAIL A2 THRU 1X WOOD INTO MASONRY EXTERIOR SEE BACKBEDDING DETAILS, SHEET 6 42 FOR ANCHORLESS JAMBS, MUST BE CONTINUOUS FOR THE FULL HEIGHT OF THE JAMB. INSTALLATION SE BY OTHERS I" MOVEMENT AT GREATEST DP. 1 DETAIL B MULLION 3 FRAME WIDTH 1. USE ONLY SUBSTRATE APPROPRIATE ANCHORS, FOLLOW EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS PER TABLE 1, SHEET 1. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. ALL ANCHOR HEAD TYPES ARE ALLOWED. 2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY BE INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. MAXIMUM SHIM THICKNESS TO BE AS REQUIRED BY TABLES 3-8. SEE �k&© SHEET 2 TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, 7� SEE TABLE 1, SHEET 1. EXTERIOR 41 DETAIL A4 INTO METAL 1 1/2" MAX. SHIM DETAIL A3 ANCHORLESS JAMB 1/4" NUT & BOLT IF REINFORCEMENT IS REQUIRED, ?4" MAX. FROM EACH END AND 24" MAX O.C. IFORCEMENT, QUIRED 1/4" NUT & BOLT, 24" MAX. FROM TOP OF FRAME, REQUIRED FOR TRANSOM HEIGHTS OVER 22-1/4" (SEE SEPARATE APPROVAL) EXTERIOR APPROVED MULLION, ALUMINUM OR STEEL FRAMING. SEE TABLE 1, SHEET 1. EDGE yD IST. 1-3/8" 1 1/4" NUT & BOLT, 24" MAX. FROM EACH END AND 24" MAX O.C. (SEE SEPARATE APPROVAL) I II II II I I I I I I I I II II I II I I I III�I I —_------- 1 L -------------- f�� ATTACHED COMPATIBLE STOREFRONT DOOR, SEE SEPARATE ' v APPROVAL FOR V 1 0 uj SPECIFICATIONS ni d W ATTACHED COMPATIBLE STOREFRONT DOOR TRANSOM, SEE SEPARATE APPROVAL FOR SPECIFICATIONS I ii II I I _ � L----L--L- --- �� i`GE ` * No. J/ �0. STAI .!�CO S A. LYNN P P.EJ i NSF • ���� �' ,8705 r 2/20 E OF ((/� �N 41LLER, P.E. 58705 EMBEDMENT DETAIL S1 DETAIL T DETAIL S4 INTO MASONRY MULLION INTO METAL 11 OR WOOD OPTIONAL 14 OPTIONAL 13 REQUIRED AT EACH Oo EDGE 5 ANCHOR LOCATION, REINFORCEMENT SEE A & EDGE DISTANCE MIN. 3" LENGTH (IF REQUIRED) 10 SHEET 2 DISTANCE TYP. ANCHOR TYPE, $ EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. TYP. ANCHOR TYPE, EMBEDMENT AND DAYLIGHT OPENING WIDTH EDGE DISTANCE PER 40 OPTIONAL APPROVED MULLION, SUBSTRATE, SEE LAMI IG GLASS ALUMINUM OR STEEL FRAMING. TABLE 1, SHEET 1. 40 SEE TABLE 1, SHEET 1. CONCRETE/CMU PER ANCHOR REQUIREMENT, 2X WOOD BUCK OR WOOD FRAMING SEE BACKBEDDING EXTERIOR EXTERIOR 11 DETAILS, SHEET 6 42 3 � 41 1/2" MAX. SHIM 1/2" MAX. SHIM � FRAME WIDTH EMBEDMENT 1X WOOD BUCKSTRIP, SEE NOTE 2, THIS SHEET. - DETAIL S2 THRU 1X WOOD INTO MASONRY EDGE a DIST+ANC, 11 rip E a a TYP. ANCHOR TYPE, ° EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE °` e TABLE 1, SHEET 1. Qa CONCRETE/CMU PER ANCHOR ° a REQUIREMENT EXTERIOR d 1/2" MAX. SHIM FOR ANCHORLESS JAMBS, MUST BE CONTINUOUS FOR THE FULL HEIGHT OF THE JAMB. INSTALLATION SE BY OTHERS MOVEMENT AT GREATEST DP. DETAIL S3 ANCHnRI ESS INSTALLATION NOTES: l4" NUT &BOLT IF 1. USE ONLY SUBSTRATE APPROPRIATE o U) Z aays 'EINFORCEMENT IS ANCHORS, FOLLOW EMBEDMENT, EDGE � w j ;EQUIRED, DISTANCE AND SUBSTRATE REQUIREMENTS b ci w z 0 >� 4" MAX. FROM EACH PER TABLE 1, SHEET 1. ANY INSTALLATION J v c, Q z rn N z Z ND AND 24"MAX O.C. OPTION SHOWN MAY BE USED ON ANY SIDE > z�� o c ~ OO N U O as S OF THE WINDOW. ALL ANCHOR HEAD TYPES z ❑ p F- ARE ALLOWED. N ,O uwi a N a0M _�cnww Q E LL. ^OI N INFORCEMENT 2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK m z u- o-1 o 0 0 M REQUIRED) ARE TO BE CONSIDERED 1X INSTALLATIONS. o C v 0 z w w c = O 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY ¢ w — c> � 0- w _ BE INSTALLED DIRECTLY TO SUBSTRATE. W o > � WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" a z a }il asaQ sauas THICK OR GREATER. I AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO + I PROPERLY TRANSFER LOADS TO THE �� �YNN,y��%,� STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF .`,�\�.0�1� \ �ICENF THE ENGINEER OR ARCHITECT OF RECORD. 1 QC�• C�� MAXIMUM SHIM THICKNESS TO BE AS No. 58705 REQUIRED BY TABLES 3-8. Z * ; - -_ 912212�� ` 0. STATE OF ((/ �40RIDP. �-N 10NAL A. LYNN MILLER, P.E. P.E.# 58705 DETAIL F1 THRU 1X WOOD CONCRETE/CMU PER INTO MASONRY ANCHOR REQUIREMENT 1X WOOD BUCKSTRIP, SEE EDGE NOTE 2, THIS SHEET. DISTANCE w v w B 1/2" MAX. DAYLIGHT OPENING HEIGHT I 30 FRAME HEIGHT 42 SEE BACKBEDDING DETAILS, THIS SHEET 41 31 _' E 40) X--� 7 OPTIONAL LAM I IG GLASS DETAIL F2 INTO WOOD 2X WOOD BUCKSTRIP OR FRAMING, SEE ANCHOR NOTE 3, SHEET 1 EMBEDMENT \ L 1/2" MAX. r7 EXTERIOR l� TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. 2 60" MAX. HORIZ. MULLION LENGTH DETAIL G HORIZ. MULLION TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. U REQUIRED AT EACH ANCHOR LOCATION, MIN. 3" LENGTH 1/2" MAX. SHIM oe e P °o EMBEDMENT p o ° p o° CONCRETE/CMU PER EDGE _ ANCHOR REQUIREMENT DISTANCE DETAIL H INTO MASONRY DETAIL F3 INTO MASONRY CONCRETE/CMU PER ANCHOR _ EDGE _ EDGE REQUIREMENT DISTANCE DISTANCE EMBEDMENT °oa EMBEDMENT v 1/2" 1 /� MAX. MA) EXTERIOR a TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1. SHEET 1. INSTALLATION NOTES: 1. USE ONLY SUBSTRATE APPROPRIATE ANCHORS, FOLLOW EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS PER TABLE 1, SHEET 1. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. ALL ANCHOR HEAD TYPES ARE ALLOWED. 2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY BE INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. MAXIMUM SHIM THICKNESS TO BE AS REQUIRED BY TABLES 3-8. Glass Types 1 9/16" Lami.: 1/4" HS, .090" PVB, 1/4" HS 2 9/16" Lami.: 1/4" HS, .090" SG, 1/4" HS 3 1-1/4" Lami. IG: 1/4" HS, .090" PVB, 1/4" HS, 7/16" Airspace, 1/4" Temp. 4 1-1/4" Lami. IG: 1/4" HS, .090" SG, 1/4" HS, 7/16" Airspace, 1/4" Temp. 1) PVB & SG INTERLAYERS BY KURARAY AMERICA, INC. 2) GLAZING FOR ALL GLASS TYPES MEETS ASTM E1300 FOR ALL APPROVED SIZES. TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. GLAZING DETAILS APPLY BACKBEDDING ALONG ENTIRE PERIMETER 42 FOR ALL GLASS TYPES 3/4" GLASS 41 EXTERIOR BITE SEE GLAZING NOTE BELOW APPLY BACKBEDDING ALONG ENTIRE PERIMETER 42 FOR ALL GLASS TYPES 3/4" GLASS 41 EXTERIOR BITE SEE GLAZING NOTE BELOW APPROVED MULLION, ALUMINUM OR STEEL FRAMING. SEE TABLE 1, SHEET 1. GLAZING NOTE: FOR GLASS TYPES 1 & 3: APPLY BACKBEDDING ALONG ENTIRE PERIMETER FOR GLASS TYPES 2 & 4: APPLY BACKBEDDING ALONG 20" FROM EACH CORNER EDGE _ DISTANCE TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. ` # No. 449- STA1 40 A. LYNN P REJ I l I I I / / �N/V ,s705 2/20 E OF ((/� 1ILLER, P.E. 58705 DETAIL J PTACINSERT REMOVE GLAZING LEG AS REQUIRED FOR PTAC LOUVER INSTALLATION a DETAIL K PTACINSERT DETAIL L PTACINSERT 2 40) X--� 7 I� '\ REFER TO PTAC LOUVER APPROVAL FOR LOUVER INSTALLATION REQUIREMENTS I I. I 2 PTAC LOUVER, REFER TO SEPARATE APPROVAL FOR "ALLATION REQUIREMENTS -------------------- _7I _ T l ------------------------ _-r_____------------------------------------------- - REMOVE GLAZING LEG AS REQUIRED FOR PTAC LOUVER INSTALLATION PTAC LOUVER & WINDOW INSERT NOTES: 1. REFER TO SEPARATE WINDOW APPROVAL FOR ALL WINDOW INSERT REQUIREMENTS AND INSTALLATION. 2. AWNING WINDOW INSERT SHOWN BUT MAY BE ANY APPROVED PGT, CGI OR WINDOOR WINDOW WITH A FLANGED FRAME. 3. REFER TO PTAC LOUVER APPROVAL FOR ALL PTAC LOUVER REQUIREMENTS AND INSTALLATION. 4. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. INSTALLATION NOTES: 1. USE ONLY SUBSTRATE APPROPRIATE ANCHORS, FOLLOW EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS PER TABLE 1, SHEET 1. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. ALL ANCHOR HEAD TYPES ARE ALLOWED. 2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY BE INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS AAX. SHIM DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE v1ENT ENGINEER OR ARCHITECT OF RECORD. MAXIMUM SHIM THICKNESS TO BE AS REQUIRED BY TABLES 3-8, SHEETS 5-10. 1.000" EXTERIOR DETAIL M ID PTACINSERT 1.000" SEE ©& SHEET 2 EDGE DISTANCE EMBEDMENT 1/2" MAX. j DETAIL N SHIM WINDOW INSERT EXTERIOR E ,\ LL_t ---� PGT, CGI OR WINDOOR FLANGED WINDOW (AWNING ' SHOWN), REFER TO SEPARATE APPROVAL FOR INSTALLATION REQUIREMENTS Lij' 40) \--( 7 2 (F PGT, CGI OR WINDOOR FLANGED WINDOW (AWNING 1 OR 11 SHOWN), REFER TO SEPARATE APPROVAL FOR INSTALLATION REQUIREMENTS 40 JL Irk----------� DETAIL P WINDOW INSERT f------ 51i i Ii -- REMOVE GLAZING LEG @ WINDOW INSERT a 2 DETAIL O WINDOW INSERT DETAIL Q WINDOW INSERT ,\1IIl i DICE ` * No. 91, STAI .!�40 S A. LYNN P REJ i NSF • ���� �' ,8705 2/20 E OF ((/� RI'D �N 1ILLER, P.E. 58705 TARI F 9- Max. DP due to Glass Limitations, psf Centerline Width Frame Height Glass Types 1 & 3 Glass Types 2 & 4 24" 48„ +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 54" +70/-80 +90/-120 60" +70/-80 +90/-120 70" +70/-80 +90/-120 72" +70/-80 +90/-120 84" +70/-80 +90/-120 90" +70/-80 +90/-120 92" +70/-80 +90/-120 96" +70/-80 +90/-120 102" +90/-120 108" +90/-120 120" +90/-120 132" +90/-100 144" +90/-100 168" +60/-60.7 180" +60/-60 24" 60„ +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 54" +70/-80 +90/-120 60" +70/-80 +90/-120 70" +70/-80 +90/-120 72" +70/-80 +90/-120 84" +90/-119.5 90" +90/-115.2 92" +90/-114 96" +90/-111.7 102" +90/-100 108" +90/-100 120" +90/-100 132" +70/-70 144" +70/-70 24" 72„ +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 54" +70/-80 +90/-120 60" +70/-80 +90/-120 70" +90/-120 72" +90/-120 84" +90/-100 90" +90/-100 92" +90/-100 96" +90/-100 102" +70/-70 108" +69.3/-69.3 120" +66/-66 Max. DP due to Glass Limitations, psf Centerline Width Frame Height Glass Types 1 & 3 Glass Types 2 & 4 24" 78" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 54" +70/-80 +90/-120 60" +68.6/-78.5 +90/-120 70" +90/-119.4 72" +90/-118.9 84" +90/-100 90" +90/-100 92" +90/-100 96" +70/-70 102" +69/-69 108" +66.8/-66.8 24" 84„ +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 54" +69.2/-79.1 +90/-120 60" +90/-119.5 70" +90/-100 72" +90/-100 84" +90/-100 90" +70/-70 92" +70/-70 96" +70/-70 102" +67.3/-67.3 24" 90" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 54" +90/-120 60" +90/-115.2 70" +90/-100 72" +90/-100 84" +70/-70 90" +70/-70 92" +70/-70 96" +69.6/-69.6 24" 97-3/4" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 54" +90/-117.9 60" +90/-100 70" +90/-100 72" +89/-99 84" +69.4/-69.4 24" 102" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +90/-120 54" +90/-116.1 60" +90/-100 70" +88.1 /-97.9 72" +70/-70 84" +67.3/-67.3 Max. DP due to Glass Limitations, psf Centerline Width Frame Height Glass Types 1 & 3 Glass Types 2 & 4 24" 108" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +90/-120 54" +90/-100 60" +90/-100 70" +70/-70 72" +69.3/-69.3 24" 114" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +90/-120 48" +90/-120 54" +90/-100 60" +90/-100 70" +68.6/-68.6 72" +67.5/-67.5 24" 120" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +90/-120 48" +90/-120 54" +90/-100 60" +90/-100 70" +67.1 /-67.1 72" +66/-66 24" 126" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +90/-120 48" +90/-100 54" +90/-100 60" +70/-70 24" 132" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +90/-120 42" +90/-120 48" +90/-100 54" +90/-100 60" +70/-70 24" 138" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +90/-120 42" +90/-100 48" +90/-100 54" +65.6/-65.6 60" +70/-70 24" 144" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +90/-120 42" +90/-100 48" +90/-100 54" +70/-70 60" +70/-70 24" 168" +60/-75 30" +60/-75 36" +60/-75 42" +60/-67.9 48" +60/-60.7 24" 180" +60/-75 30" +60/-75 36" +60/-75 42" +60/-67.3 48" +60/-60 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. CENTERLINE _ CENTERLINE WIDTH WIDTH 7 DLO WIDTH DLO HEIGHT FRAME HEIGHT / 1" ---� DLO WIDTH DLO /HEIGHT 1 DLO WIDTH DLO /HEIGHT / FRAME WIDTH FRAME WIDTH — 1 — 9/16" LAMINATED GLASS STACK 090" PVB INTERLAYER 1/4" HEAT - STRENGTHENED GLASS GLASS TYPE 1 9/16" LAMINATED i GLASS STACK 090" SG INTERLAYER 1/4" H EAT - STRENGTHENED GLASS GLASS TYPE 2 FRAME HEIGHT CENTERLINE HEIGHT FRAME HEIGHT CENTERLINE HEIGHT DLO (DAYLIGHT OPENING) FORMULAS: FRAME WIDTH - 4" = DLO WIDTH FRAME HEIGHT - 4" = DLO HEIGHT CENTERLINE WIDTH - 3" = DLO WIDTH CENTERLINE HEIGHT - 3" = DLO HEIGHT CENTERLINE WIDTH - 1-1/2" = GLASS WIDTH CENTERLINE HEIGHT - 1-1/2" = GLASS HEIGHT FRAME WIDTH - 2-1/2" = GLASS WIDTH FRAME HEIGHT - 2-1/2" = GLASS HEIGHT 1-1/4" NOM. I.G. 9/16" LAMINATED GLASS STACK GLASS STACK .090" PVB INTERLAYER 1/4" HEAT- I STRENGTHENED GLASS�]-7/16" AIRSPACE EXTERIOR 36-39 1/4" TEMPERED GLASS a GLASS TYPE 3 _ 1-1/4" NOM. I.G. 9/16" LAMINATED _ GLASS STACK i GLASS STACK 090" SG INTERLAYER 1/4" HEAT - STRENGTHENED GLASS 7/16" AIRSPACE EXTERIOR 36-39 1/4" TEMPERED GLASS a�07GLASS TYPE 4 Glass Types 1 9116" Lami.: 114" HS, .0910" PVB, 114" HIS 2 9116" Lami.: 114" HS, .090" SG, 1/4" HIS 3 1-114" Lauri- IG: 114" HS, .090" PVB, 114" HS, 7116" Airspace, 1/4" Temp. 4 1-14' Lami. IG: 114" HS, .090" SG, V4" HIS, 7/16" Airspace, 114" Ternp. 1) PVB & SG INTERLAYERS BY KURARAY AMERICA, INC. 2) GLAZING FOR ALL GLASS TYPES MEETS ASTM E1300 FOR ALL APPROVED SIZES. \\1IIli �� L ` * No.: �ta STAI 40 A. LYNN I P.EJ 11111y` ,870s 2I20 z E OF TILLER, P.E. 58705 TABLE 3: Mullion Anchor Cluster DP at Head/Sill, (+/- pst Shim Thickness: 1/4" Average Centerline Width Frame Height Group "A" Anchor Quantity Group "B" Anchor Quantity Group "C" Anchor Quantity Group "D" Anchor Quantity 4 6 4 6 4 6 4 6 24" 48„ 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 72" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 90" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 120.0 1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 102" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 132" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 144" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 168" 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 180" 75.0 1 75.0 75.0 1 75.0 75.0 75.0 75.0 75.0 24" 60" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 120.0 120.0 120.0 1 120.0 120.0 120.0 120.0 120.0 72" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 90" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 102" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 132" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 144" 120.0 120.0 120.0 120.0 120.0 1 120.0 120.0 120.0 24" 72„ 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 118.5 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 114.3 120.0 120.0 120.0 120.0 120.0 70" 120.0 120.0 111.2 120.0 120.0 120.0 120.0 120.0 72" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 90" 120.0 120.0 111.1 1 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 96" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 102" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 108" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 24" 78" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 104.6 120.0 120.0 120.0 120.0 120.0 60" 118.1 120.0 100.0 120.0 120.0 120.0 120.0 120.0 70" 113.0 120.0 95.7 120.0 120.0 120.0 120.0 120.0 72" 112.5 120.0 95.2 120.0 120.0 120.0 120.0 120.0 84" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 90" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 92" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 96" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 102" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 108" 111.8 120.0 1 94.7 1 120.0 120.0 1 120.0 120.0 120.0 Mullion Anchor Cluster DP at Head/Sill, (+/- pst Shim Thickness: 1/4" Average Centerline Width Frame Height "A" A�chor;Quantity Group "B" Anchor Quantity Group "C" Anchor Quantity Group "D" Anchor Quantity 4 8 4 6 8 4 1 6 8 1 4 6 24" 84" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 108.8 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 118.1 120.0 120.0 100.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 110.5 120.0 120.0 93.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 105.0 120.0 120.0 88.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 99.2 120.0 120.0 84.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 72" 98.4 120.0 120.0 83.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 90" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 126.0 120.0 92" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 102" 1 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 24" 90" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 1 120.0 36" 120.0 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 117.4 120.0 120.0 99.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 107.4 120.0 120.0 90.9 120.0 120.0 120.0 120.0 120.01 120.0 120.0 54" 100.0 120.0 120.0 84.7 1 120.01 120.0 120.0 120.0 120.0 120.0 120.0 60" 94.5 120.0 120.0 80.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 88.4 120.0 120.0 74.8 112.2 120.0 112.2 120.0 120.0 120.0 120.0 72" 87.5 120.0 120.0 74.1 111.1 120.0 111.1 120.0 120.0 120.0 120.0 84" 84.4 120.0 120.0 71.4 107.1 120.0 107.1 120.0 120.0 120.0 120.0 90" 84.0 120.0 120.0 71.1 106.7 120.0 106.7 120.0 120.0 120.0 120.0 92" 84.0 1 120.0 120.0 71.1 106.7 120.0 106.7 120.0 120.0 120.0 120.0 96" 84.0 1 120.01 120.0 71.1 106.7 120.0 106.7 120.0 120.0 120.0 120.0 24" 97-3/4 1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 116.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 118.5 120.0 120.0 100.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 105.5 120.0 120.0 89.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 96.1 120.0 120.0 81.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 89.0 120.0 120.0 75.4 113.1 120.0 113.1 120.0 120.0 120.0 120.0 60" 83.7 120.0 120.0 70.8 106.3 120.0 106.3 120.0 120.0 120.0 120.0 70" 77.4 116.2 120.0 65.6 98.3 120.0 98.3 120.0 120.0 120.0 120.0 72" 76.5 114.8 120.0 64.8 97.2 120.0 97.2 120.0 120.0 120.0 120.0 84" 72.6 1 109.0 120.0 61.5 92.2 1 120.0 92.2 120.0 120.0 120.0 120.0 24" 102 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 110.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 112.5 120.0 120.0 95.2 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 100.0 120.0 120.0 84.7 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 90.9 120.0 120.0 76.9 115.4 120.0 115.4 120.0 120.0 120.0 120.0 54" 84.0 120.0 120.0 71.1 106.7 120.0 106.7 120.0 120.01 120.0 120.0 60" 78.7 118.1 120.0 66.7 100.0 120.0 100.0 120.0 120.0 120.0 120.0 70" 72.5 108.8 120.0 61.4 92.1 120.0 92.1 120.0 120.0 120.0 120.0 72" 71.6 107.4 120.0 60.6 90.9 120.0 90.9 120.0 120.0 120.0 120.0 84" 67.5 101.2 120.0 57.1 85.7 114.3 85.7 1 120.0 120.0 120.0 1 120.0 24" 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 103.2 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 105.0 120.0 120.0 88.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 93.1 120.0 120.0 78.8 118.2 120.0 118.2 120.0 120.0 120.0 120.0 48" 84.4 120.0 120.0 71.4 107.1 120.0 107.1 120.0 120.0 120.0 120.0 54" 77.8 116.7 120.0 65.8 98.8 120.0 98.8 120.0 120.0 120.0 120.0 60" 72.7 109.0 120.0 61.5 92.3 120.0 92.3 120.0 120.0 120.0 120.0 70" 66.6 99.9 120.0 56.4 84.5 112.7 84.5 120.0 120.0 120.0 120.0 72" 65.6 1 98.4 120.01 55.6 83.3 111.1 83.3 120.0 120.0 120.0 120.0 24" 114" 120.0 120.0 120.0 117.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 114.5 120.0 120.0 97.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 98.4 120.0 120.0 83.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 87.1 120.0 120.0 73.7 110.6 120.0 110.6 120.0 120.0 120.0 120.0 48" 78.7 118.1 120.0 66.7 100.0 120.01 100.0 120.0 120.0 120.0 120.0 54" 72.4 108.6 120.0 61.3 92.0 120.0 92.0 120.0 120.0 120.0 120.0 60" 67.5 101.2 120.0 57.1 85.7 114.3 85.7 120.0 120.0 120.0 120.0 70" 61.5 92.3 120.0 52.1 78.1 104.21 78.1 117.2 120.01 120.0 120.0 72" 60.6 90.9 120.0 51.3 76.9 102.61 76.9 115.4 120.01 120.0 120.0 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. FOR SIZES NOT SHOWN, ROUNDUP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. FOR ANCHORLESS JAMBS USE ONLY HALF OF THE ANCHORS SPECIFIED IN TABLE 3, AND: AVERAGE CENTERLINE CENTERLINE = WIDTH 1 WIDTH FOR INTERIOR MULLION CLUSTERS USE THE QUANTITY OF ANCHORS SPECIFIED IN TABLE 3, AND: AVERAGE CENTERLINE+CENTERLINE CENTERLINE = WIDTH 1 WIDTH 2 WIDTH 2 m Q FRAME w HEIGHT Of O 2 U Z Q 3" _ SEE TABLE 1, SHEET 1 FORi ANCHOR MIN. O.C. SPACING, 4" MAX. CENTERLINE WIDTH 1 SILL SHOWN, HEAD SIMILAR Mullion Anchor Cluster DP at Head/Sill, (+/- pst Shim Thickness: 1/4" Average Centerline Width Frame Height Group "A" Anchor Quantity Group "B" Anchor Quantity Group "C" Anchor Quantity Group "D" Anchor Quantity 4 6 8 4 6 8 4 6 1 8 4 6 24" 120" 120.0 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 108.0 120.0 120.0 91.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 92.6 120.0 120.0 78.4 117.6 120.0 117.6 120.0 120.0 120.0 120.0 42" 81.8 120.0 120.0 69.3 103.9 120.0 103.9 120.0 120.0 120.0 120.0 48" 73.8 110.7 120.0 62.5 93.8 120.0 93.8 120.0 120.0 120.0 120.0 54" 67.7 101.6 120.0 57.3 86.0 114.7 86.0 120.0 120.0 120.0 120.0 60" 63.0 94.5 120.0 53.3 80.0 106.7 80.0 120.0 120.0 120.0 120.0 70" 57.2 85.8 114.3 48.4 72.6 96.8 72.6 108.9 120.0 120.0 120.0 72" 56.2 84.4 112.5 47.6 71.4 95.2 71.4 107.1 120.0 120.0 120.0 24" 126" 120.0 120.0 120.0 105.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 102.2 120.0 120.0 86.5 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 87.5 120.0 120.0 74.1 111.1 120.0 111.1 120.0 120.0 120.0 120.0 42" 77.1 115.7 120.0 65.3 98.0 120.0 98.0 120.0 120.0 120.0 120.0 48" 69.5 104.2 120.0 58.8 88.2 117.6 88.2 120.0 120.0 120.0 120.0 54" 63.6 95.5 120.0 53.9 80.8 107.7 80.8 120.0 120.0 120.0 120.0 60" 59.1 88.6 118.1 50.0 75.0 100.0 75.0 112.5 120.0 120.0 120.0 24" 132" 118.1 120.0 120.0 100.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 96.9 120.0 120.0 82.1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 82.9 120.0 120.0 70.2 105.3 120.0 105.3 120.0 120.0 120.0 120.0 42" 73.0 109.5 120.0 61.8 92.7 120.0 92.7 120.0 120.0 120.0 120.0 48" 65.6 98.4 120.0 55.6 83.3 111.1 83.3 120.0 120.0 120.0 120.0 54" 60.0 90.0 120.0 50.8 76.2 101.6 76.2 114.3 120.0 120.0 120.0 60" 55.6 83.4 111.2 47.1 70.6 94.1 70.6 105.9 120.0 120.0 120.0 24" 138" 112.5 120.0 120.0 95.2 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 92.2 120.0 120.0 78.0 117.1 120.0 117.1 120.0 120.0 120.0 120.0 36" 78.7 118.1 120.0 66.7 100.0 120.0 100.0 120.0 120.0 120.0 120.0 42" 69.2 103.8 120.0 58.6 87.9 117.2 87.9 120.0 120.0 120.0 120.0 48" 62.2 93.3 120.0 52.6 78.9 105.3 78.9 118.4 120.0 120.0 120.0 54" 56.8 85.1 113.5 48.0 72.1 96.1 72.1 108.1 120.0 120.0 120.0 60" 52.5 78.7 105.0 44.4 66.7 88.9 66.7 100.0 120.0 120.0 120.0 24" 144" 107.4 120.0 120.0 90.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 87.9 120.0 120.0 74.4 111.6 120.0 111.6 120.0 120.0 120.0 120.0 36" 75.0 112.5 120.0 63.5 95.2 120.0 95.2 120.0 120.0 120.0 120.0 42" 65.9 98.8 120.0 55.7 83.6 111.5 83.6 120.0 120.0 120.0 120.0 48" 59.1 88.6 118.1 50.0 75.0 100.0 75.0 112.5 120.0 120.0 120.0 54" 53.8 80.8 107.7 45.6 68.4 91.2 68.4 102.6 120.0 120.0 120.0 60" 49.7 74.6 99.5 42.1 63.2 84.2 63.2 94.7 120.0 116.4 120.0 24" 168" 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 30" 74.1 1 75.0 75.0 62.7 75.0 75.0 75.0 75.0 75.0 75.0 75.0 36" 63.0 75.0 75.0 53.3 75.0 75.0 75.0 75.0 75.0 75.0 75.0 42" 55.1 75.0 75.0 46.6 70.0 75.0 70.0 75.0 75.0 75.0 75.0 48" 49.2 73.8 75.0 41.7 62.5 75.0 62.5 75.0 75.0 75.0 75.0 24" 180" 75.0 75.0 75.0 71.4 75.0 75.0 75.0 75.0 75.0 75.0 75.0 30" 68.7 75.0 75.0 58.2 75.0 75.0 1 75.0 75.0 75.0 75.0 75.0 36. 58.3 75.0 75.0 49.4 74.1 75.0 74.1 75.0 75.0 75.0 75.0 42" 50.9 75.0 75.0 43.1 64.7 75.0 64.7 75.0 75.0 75.0 75.0 48" 45.4 1 68.1 75.0 38.5 57.7 75.0 57.7 75.0 1 75.0 1 75.0 75.0 CENTERLINE WIDTH 2 T' SEE TABLE 1, SHEET 1 FOR ANCHOR MIN. O.C. SPACING, 4" MAX. \\1,NIIJIIIII// ���•\�cj�V LYNN, * : No. 58705 _ (/ 7/LL/2.0 ] pSTATE OF t ;gy'• ' T,(� F(0R10P � 0NAL \`\\\ A. LYNN MILLER, P.E. P.E.# 58705 TABLE 4 Mullion Anchor Cluster DP at Head/Sill, (+/- psfl Shim Thickness: 1/2" Average Centerline Width Frame Height Group "A" Anchor Quantity Group "B" Anchor Quantity Group "C.' Group "D" Anchor Quantity Anchor Quantity 4 6 4 6 4 6 4 6 24" 48„ 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 72" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 90" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 102" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 132" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 144" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 168" 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 180" 75.0 75.0 75.0 1 75.0 75.0 1 75.0 75.0 1 75.0 24" 60„ 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 120.0 120.0 120.0 1 120.0 120.0 120.0 70" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 72" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 90" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 102" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 132" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 1"" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 24" 72„ 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 1 120.0 120.0 1 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 118.5 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 114.3 120.0 120.0 120.0 120.0 120.0 70" 120.0 120.0 111.2 120.0 120.0 120.0 120.0 120.0 72" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 111.1 120.0 120.0 1 120.0 120.0 120.0 90" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 96" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 102" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 108" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 24" 78" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 104.6 120.0 120.0 120.0 120.0 120.0 60" 118.1 120.0 100.0 120.0 120.0 120.0 120.0 120.0 70" 113.0 120.0 1 95.7 120.0 120.0 1 120.0 120.0 120.0 72" 112.5 120.0 95.2 120.0 120.0 120.0 120.0 120.0 84" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 90" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 92" 111.8 120.0 94.7 120.0 120.0 120.0 1 120.0 120.0 96" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 102" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 108" 111.8 1 120.0 1 94.7 1 120.0 1 120.0 1 120.0 120.0 120.0 Mullion Anchor Cluster DP at Head/Sill, (+/- psfl Shim Thickness: 1/2" Average Centerline Width FrameFAnchor Height Group "A" Quantity Group "B" Anchor Quantity Group "C" Anchor Quantity Group "D" Anchor Quantity 6 8 4 6 8 4 6 8 4 6 24" M„ 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.01 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 108.8 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 118.1 120.0 120.0 100.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 110.5 120.0 120.0 93.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 105.0 120.0 120.0 88.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 99.2 120.0 120.0 84.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 72" 98.4 120.0 120.0 83.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 M.. 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.01 120.0 120.0 90" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 102" 96.4 120.0 120.0 81.6 120.01 120.01 120.0 120.0 120.0 120.0 120.0 24" 90" 1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 117.4 120.0 120.0 99.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 107.4 120.0 120.0 90.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 100.0 120.0 120.01 84.7 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 94.5 120.0 120.0 80.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 88.4 120.0 120.0 74.8 112.2 120.0 112.2 120.0 120.0 120.0 120.0 72" 87.5 120.0 120.0 74.1 111.1 120.0 111A 120.0 120.0 120.0 120.0 MI. 84.4 120.0 120.0 71.4 107.1 120.0 107.1 120.0 120.0 120.0 120.0 90" 84.0 120.0 120.0 71.1 106.7 120.0 106.7 120.0 120.0 120.0 120.0 92" 84.0 1 120.0 120.0 71.1 106.7 120.0 106.7 120.01 120.0 120.0 120.0 96" 84.0 1 120.0 1120.0 71.1 106.7 120.0 106.7 120.0 120.0 120.0 120.0 24" 97-3/4" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 116.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 118.5 120.0 120.0 100.3 120.0 120.0 120.0 120.0 120.01 120.0 120.0 42" 105.5 120.0 120.0 89.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 96.1 120.0 120.0 81.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54„ 89.0 120.0 120.0 75.4 113.1 120.0 113.1 120.0 120.0 120.0 120.0 60" 83.7 120.0 120.0 70.8 106.3 120.0 106.3 120.0 120.0 120.0- 120.0 70" 77.4 116.2 120.0 65.6 98.3 120.0 98.3 120.0 120.0 120.0 120.0 72" 76.5 114.8 120.0 64.8 97.2 120.0 97.2 120.0 120.0 120.0 120.0 84" 72.6 109.0 120.0 61.5 92.2 120.0 92.2 120.0 120.01 120.0 120.0 24" 102 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 110.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 112.5 120.0 120.0 95.2 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 100.0 120.0 120.0 84.7 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 90.9 120.0 120.0 76.9 115.4 120.0 115.4 120.0 120.0 120.0 120.0 54" 84.0 120.0 120.0 71.1 106.7 120.0 106.7 120.0 120.0 120.0 120.0 60" 78.7 118.1 120.0 66.7 100.0 120.0 100.0 120.0 120.01 120.0 120.0 70" 72.5 108.8 120.0 61.4 92.1 120.0 92.1 120.0 120.0 120.0 120.0 72" 71.6 107.4 120.0 60.6 90.9 120.0 90.9 120.0 120.0 120.0 120.0 84" 67.5 101.2 120.0 57.1 85.7 114.3 85.7 120.0 120.0 120.0 120.0 24" 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 103.2 120.01 120.0 120.0 1120.0 120.0 120.0 120.0 36" 105.0 120.0 120.0 88.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 93.1 120.0 120.0 78.8 118.2 120.0 118.2 120.0 120.01 120.0 120.0 48" 84.4 120.0 120.0 71.4 107.1 120.0 107.1 120.0 120.0 120.0 120.0 54" 77.8 116.7 120.0 65.8 98.8 120.0 98.8 120.0 120.0 120.0 120.0 60'. 1 72.7 109.0 120.0 61.5 92.3 120.0 92.3 120.0 120.0 120.0 120.0 70" 66.6 99.9 120.0 56.4 84.5 112.7 84.5 120.0 120.0 120.0 120.0 72" 65.6 98.4 120.0 55.6 83.3 111.1 83.3 120.0 120.0 120.0 120.0 24" 114" 120.0 120.0 120.0 117.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 114.5 120.0 120.0 97.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 98.4 120.0 120.0 83.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 87.1 120.0 120.0 73.7 110.6 120.0 110.6 120.0 120.0 120.0 120.0 48" 78.7 118.1 120.0 66.7 100.0 120.0 100.0 120.0 120.0 120.0 120.0 54" 72.4 108.6 1120.01 61.3 92.0 120.0 92.0 120.0 120.0 120.0 120.0 60" 67.5 101.2 1120.01 57.1 1 85.7 114.3 85.7 120.0 120.0 120.0 120.0 70" 61.5 92.3 120.0 52.1 78.1 104.2 78.1 117.2 120.0 120.0 120.0 72" 60.6 90.9 120.0 51.3 76.9 102.E 76.9 115.4 120.0 120.0 120.0 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. FOR ANCHORLESS JAMBS USE ONLY HALF OF THE ANCHORS SPECIFIED IN TABLE 3, AND: AVERAGE CENTERLINE CENTERLINE = WIDTH 1 WIDTH m Q FOR INTERIOR MULLION CLUSTERS FRAME w USE THE QUANTITY OF ANCHORS HEIGHT � SPECIFIED IN TABLE 3, AND: p AVERAGE CENTERLINE+CENTERLINE z CENTERLINE = WIDTH 1 WIDTH 2 Q WIDTH 2 3" SEE TABLE 1, SHEET 1 FOP ANCHOR MIN. O.C. SPACING, 4" MAX CENTERLINE CE f WIDTH 1 CENTEF WIDTI SILL SHOWN, HEAD SIMILAR I rt _ 3" rt SEE TABLE 1, SHEET FOR ANCHOR MIN. O CPA(JNr'� d" KAAX Mullion Anchor Cluster DP at Head/Sill, (+/- pst Shim Thickness: 1/2" Average Centerline Width Frame Height Group "A" Anchor Quantit y Group "B" Anchor Quantity y Group "C" Anchor Quantity � Group "D" Anchor Quantit y 4 1 6 1 8 1 4 1 6 1 8 4 6 1 8 4 6 24" 120" 1200. 1200. 1200. 111.1 1200. 1200. 1200. 1200. 1200. 1200. 120.0 30" 108.0 1200. 1200. 91.4 1200. 1200. 1200. 1200. 1200. 1200. 120.0 36" 92.6 1200. 1200. 78.4 117.6 1200. 117.6 1200. 1200. 1200. 120.0 42" 81.8 1200. 1200. 69.3 103.9 1200. 103.9 1200. 1200. 1200. 1200. 48" 73.8 110.7 1200. 62.5 93.8 1200. 93.8 1200. 1200. 1200. 120.0 54" 67.7 101.6 1200. 57.3 86.0 114.7 86.0 1200. 1200. 1200. 1200. 60" 63.0 94.5 1200. 53.3 80.0 106.7 80.0 1200. 1200. 1200. 120.0 70" 572 85.8 114.3 48.4 72.6 96.8 72.6 108.9 1200. 1200. 120.0 72" 562 1 84.4 112.5 47.6 71.4 1 952 71.4 107.1 1120-01 1200. 120.0 24" 126' 1200. 1200. 1200. 105.3 1200. 1200. 1200. 1200. 1200. 1200. 120.0 30" 1022 120.0 120.0 86.5 1200. 1200. 1200. 1200. 1200. 120.0 120.0 36" 87.5 1200. 1200. 74.1 111.1 1200. 111.1 1200. 1200. 1200. 1200. 42" 77.1 115.7 1200. 65.3 98.0 1200. 98.0 1200. 1200. 1200. 1200. 48" 69.5 1042 1200. 58.8 882 117.6 882 1200. 1200. 1200. 120.0 54" 63.6 95.5 1200. 53.9 80.8 107.7 80.8 1200. 1200. 1200. 120.0 60" 59.1 88.6 118.1 50.0 75.0 100.0 75.0 112.5 1200.. 1200. 1200. 24" 132" 118.1 1200. 1200. 100.0 1200. 1200. 1200. 1200. 1200. 1200. 120.0 30" 96.9 120.0 120.0 82.1 1200. 1200. 120.0 1200. 1200. 120.0 120.0 36" 82.9 1200. 1200. 702 105.3 1200. 105.3 120.0 1200. 120.0 1200. 42" 73.0 109.5 1200. 61.8 92.7 1200. 92.7 1200. 1200. 1200. 1200. 48" 65.6 98.4 1200. 55.6 83.3 111.1 83.3 1200. 120.0 120.0 120.0 54" 60.0 90.0 1200. 50.8 762 101.6 762 114.3 120.0 1200. 1200. 60" 55.6 83.4 1112 47.1 70.6 94.1 70.6 105.9 120.0 1200. 1200. 24" 138' 112.5 1200. 1200. 952 1200. 1200. 1200. 1200. 1200. 1200. 120.0 30" 92.2 120.0 120.0 78.0 117.1 1200. 117A 120.0 1200. 1200. 120.0 36" 78.7 118.1 1200. 66.7 100.0 1200. 100.0 1200. 1200. 1200. 120.0 42" 69.2 103.8 1200. 58.6 87.9 1172 87.9 1200. 1200. 1200. 1200. 48" 62.2 93.3 120.0 52.6 78.9 105.3 78.9 118.4 120.0 120.0 120.0 54" 56.8 85.1 113.5 48.0 72.1 96.1 72.1 108.1 120.0 120.0 120.0 60" 52.5 78.7 105.0 44.4 66.7 88.9 66.7 100.0 1200. 1200. 120.0 24" 144" 107.4 120.0 1200. 90.9 1200. 1200. 1200. 120.0 1200. 120.0 120.0 30" 87.9 120.0 120.0 74.4 111.6 1200. 111.6 120.0 1200. 120.0 120.0 36" 75.0 112.5 1200. 63.5 95.2 120.0 952 120.0 1200. 1200. 120.0 42" 65.9 98.8 1200. 55.7 83.6 111.5 83.6 1200. 1200. 1200. 120.0 48" 59.1 88.6 118.1 50.0 75.0 100.0 75.0 112.5 120.0 120.0 120.0 54" 53.8 80.8 107.7 45.6 68.4 912 68.4 102.6 120.0 1200. 120.0 60" 49.7 1 74.6 99.5 42.1 632 842 632 94.7 1200. 116.4 120.0 24" 168" 68.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 30" 55.5 75.0 75.0 62.7 75.0 75.0 75.0 75.0 75.0 75.0 75.0 36" 47.2 70.8 75.0 53.3 75.0 75.0 75.0 75.0 75.0 75.0 75.0 42" 41.3 61.9 75.0 46.6 70.0 75.0 70.0 75.0 75.0 75.0 75.0 48" 36.9 55.3 73.7 41.7 62.5 75.0 62.5 75.0 75.0 75.0 75.0 24" 180" 63.2 75.0 75.0 71.4 75.0 75.0 75.0 75.0 75.0 1 75.0 75.0 30" 51.5 75.0 75.0 58.2 75.0 75.0 75.0 75.0 75.0 75.0 75.0 36" 43.7 65.5 75.0 49.4 74.1 75.0 74.1 75.0 75.0 75.0 75.0 42" 38.1 572 75.0 43.1 64.7 75.0 64.7 75.0 75.0 75.0 75.0 48" 34.0 1 51.0 68.0 38.5 57.7 75.0 57.7 75.0 75.0 75.0 1 75.0 \\,r4ti11i1r1//// LYNN���'�. r� 4 � * : No. 58745 22)(12On _� 441 0. STATE OF ((/ '/Irrrrll+►'�� A. LYNN MILLER, P.E. P.E.# 58705 TABLE 5: Jamb Anchor Spacing Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 48 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" 54" 18" 18" 18" 18" 60" 18" 18" 18" 18" 70" 18" 18" 18" 18" 72" 18" 18" 18" 18" 84" 18" 18" 18" 18" 90" 18" 18" 18" 18" 92" 18" 18" 18" 18" 96" 18" 18" 18" 18" 102" 18" 18" 18" 18" 108" 18" 18" 18" 18" 120" 18" 18" 18" 18" 132" 18" 18" 18" 18" 144" 18" 18" 18" 18" 168" 18" 18" 18" 18" 180" 18" 18" 18" 18" 24" 60 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" 54" 18" 18" 18" 18" 60" 18" 18" 18" 18" 70" 18" 18" 18" 18" 72" 18" 18" 18" 18" 84" 18" 18" 18" 18" 90.. 18" 18" 18" 18" 92" 18" 18" 18" 18" 96" 18" 18" 18" 18" 102" 18" 18" 18" 1 18" 108" 18" 18" 18" 18" 120" 18" 18" 18" 18" 132" 18" 18" 18" 18" 144" 18" 18" 18" 18" 24" 72 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" 54" 18" 15" 18" 18" 60" 18" 15" 18" 18" 70" 18" 15" 18" 18" 72" 18" 15" 18" 18" 84" 18" 15" 18" 18" 90.. 18" 15" 18" 18" 92" 18" 1 15" 18" 18" 15"18" 102" 18" 15" 18" J18"96" 108" 18" 15" 18" 120" 18" 15" 18" Jamb Anchor Spacing Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 78" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 16-1/2" 18" 18" 54" 18" 16-1/2" 18" 18" 60" 16-112" 16-1/2" 18" 18" 70" 16-1/2" 13-3/16" 18" 18" 72" 16-1/2" 13-3/16" 18" 18" 84" 16-1/2" 13-3/16" 18" 18" 90" 16-1/2" 13-3/16" 18" 18" 92" 16-1/2" 13-3/16" 18" 18" 96" 16-1/2" 13-3/16" 18" 18" 102" 16-1/2" 13-3/16" 18" 18" 108" 16-1/2" 13-3/16" 18" 18" 24" EA„ 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" 54" 18" 14-3/8" 18" 18" 60" 18" 14-3/8" 18" 18" 70" 18" 14-3/8" 18" 18" 72" 18" 14-3/8" 18" 18" 84" 18" 14-3/8" 18" 18" 90.. 18" 14-3/8" 18" 18" 92" 18" 14-3/8" 18" 18" 96" 18" 14-3/8" 18" 18" 102" 18" 14-3/8" 18" 18" 24" 90" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 15-5/8" 18" 18" 54" 18" 15-5/8" 18" 18" 60" 15-5/8" 15-5/8" 18" 18" 70" 15-5/8" 13" 18" 18" 72" 15-5/8" 13" 18" 18" 84" 15-5/8" 13" 18" 18" 90.. 15-5/8" 13" 18" 18" 92" 15-5/8" 13" 18" 18" 96" 15-5/8" 13" 18" 18" 24" 97-3/4" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 17-1/8" 18" 18" 48" 18" 17-1/8" 18" 18" 54" 17-1/8" 14-5/16" 18" 18" 60" 17-1/8" 14-5/16" 18" 18" 70" 14-5/16" 12-1/4" 18" 18" 72" 14-5/16" 12-1/4" 18" 18" 84" 14-5/16" 12-1/4" 17-1/8" 18" 24" 102" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 15" 18" 18" 54" 18" 15" 181, 18" 60" 15" 12-7/8" 18" 1 18' 70" 15" 12-7/8" 18" 18" 72" 15" 12-7/8" 18" 18'. 84" 12-7/8" 11-1/4" 18" 18' Jamb Anchor Spacing Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 108" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 16" 18" 18" 48" 18" 16" 18" 18" 54" 16" 13-11/16" 18" 18" 60" 16" 13-11/16" 18" 18" 70" 13-11/16" 12" 18" 18" 72" 13-11/16" 12" 18" 18" 24" 114" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 17" 18" 18" 48" 17" 14-9/16" 18" 18" A" 17" 14-9/16" 18" 18" 60" 14-9/16" 12-314" 18" 18" 70" 14-9/16" 11-5/16" 17" 18" 72" 14-9/16" 11-5/16" 17" 18" 24" 120" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 15-7/16" 18" 18" 54" 15-7/16" 13-1/2" 18" 18" 60" 15-7/16" 13-1/2" 18" 18" 70" 13-1/2" 12" 18" 18" 72" 13-1/2" 10-13/16" 18" 18" 24" 126" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 16-5/16" 18" 18" 48" 18" 14-1/4" 18" 18" 54" 16-5/16" 14-114" 18" 18" 60" 14-1/4" 12-11/16" 18" 18" 24" 132" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 17-1/8" 18" 18" 48" 17-1/8" 15" 1 18" 18" 54" 15" 135/16" 18" 18" 60" 15" 12" 18" 18" 24" 138" 18" 18" 18" 181. 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 15-3/4" 18" 18" 48" 18" 14" 18" 18" 54" 15-3/4" 14" 18" 18" 60" 14" 12-5/8" 18" 18" 24" 144" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 16-1/2" 18" 18" 48" 16-1/2" 14-11/16" 18" 18" 54" 16-1/2" 13-3/16" 18" 18" 60" 14-11/16" 12" 18" 18" 24" 168" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 1 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" 24" 180" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 1 18" 48" 181. 18" 18" 1 18" Q Z Aar FRAME WIDTH Cn O LL]N L0 6" MAX. C/3 Q / w OPTIONAL LU SEE TABLE 5, HORIZONTAL W THIS SHEET MULLION —I O co FRAME uogduosaQ nay HEIGHT S2 00 / (N O CD CD C/) � 0 � aO U) J Q W U) a 3 J_ LaL xe < 5 W Ln R3 I c� U •.a � z Q co o ui (n 2 U) UU LIJ o w'IN ow 'r Q � 00 o �Ma 0i0 �U)M U. = cM O �/) LL fh > O w� O J a (J � Q p (.5 Q r o Z }aa4S O > W U v z Y (7 cp �w� CgC6 N z z _ rn Zorn N 0 O ainsS L owW = aUv x°6Za- L0 LL O Oco c9rnw0 ¢ LL W W � Co0_j }U-jU_ U M.I WULLj OZwW � W LL M Q~ Z U H a w O 0 ow �20 U I— R �- L) (n a o Z al}il ssaQ sauas 6" MAX. _ CENTERLINE WIDTH f FRAME WIDTH - 1" 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. LYNN4��'�. r� * : No. 58705 � 9/22/2�_� STATE OF ((/� �(ORIOP. '��rrltll+►'�� A. LYNN MILLER, P.E. P.E.# 58705 TABLE 6 Jamb Anchor Spacing Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 48 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" 54" 18" 18" 18" 18" 60" 18" 18" 18" 18" 70" 18" 18" 18" 18" 72" 18" 18" 18" 18" 84" 18" 18" 18" 18" 90" 18" 18" 18" 18" 92" 18" 18" 18" 18" 96" 18" 18" 18" 18" 102" 18" 18" 18" 18" 108" 18" 18" 18" 18" 120" 18" 18" 18" 18" 132" 18" 18" 18" 18" 1 "1, 18" 18" 18" 18" 168" 18" 18" 18" 18" 180" 18" 18" 18" 18" 24" 60 18" 18" 18" 18" 30" 18" 1 18" 18" 18" 36" 18" 18" 18" 18" 42" 16" 18" 18" 18" 48" 16" 18" 18" 18" 54" 16" 18" 18" 18" 60" 16" 18" 18" 18" 70" 16" 18" 18" 18" 72" 16" 18" 18" 18" 84" 16" 18" 18" 18" 90" 16" 18" 18" 18" 92" 16" 18" 18" 18" 96" 16" 18" 18" 18" 102" 16" 18" 1 18" 18" 108" 16" 18" 18" 18" 120" 16" 18" 18" 18" 132" 16" 18" 18" 18" 1 "1, 16" 18" 18" 18" 24" 72„ 18" 18" 18" 18" 30" 18" 1 18" 18" 18" 36" 18" 18" 18" 18" 42" 15" 18" 18" 18" 48" 15" 18" 18" 18" 54" 15" 15" 18" 18" 60" 15" 15" 18" 18" 70" 15" 15" 18" 18" 72" 15" 15" 18" 18" 84" 15" 15" 18" 18" 901, 15" 15" 18" 18" 92" 15" 15" 18" 18" 96" 15" 15" 18" 181, 102" 1 15" 1 15" 18" 18" 108" 15" 15" 18" 18" 120" 15" 15" 18" 18" Jamb Anchor Spacing Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 78" 18" 18" 18" 18" 30" 18" 18" 18" 18° 36" 16-1 /2" 18" 18" 18" 42" 16-1 /2" 18" 18" 18" 48" 16-1 /2" 16-1 /2" 18" 18" 54" 13-3/16" 16-1/2" 18" 18 60" 13-3/16" 16-1/2" 18" 18" 70" 13-3/16" 13-3/16" 18" 18" 72" 13-3/16" 13-3/16" 18" 18" 84" 13-3/16" 13-3/16" 18" 18" 90" 13-3/16" 13-3/16" 18" 18" 92" 13-3/16" 13-3/16" 18" 18" 96" 13-3/16" 13-3/16" 18" 18" 102" 13-3/16" 13-3/16" 18" 18" 108" 13-3/16" 13-3/16" 18" 18" 24" 84„ 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 14-3/8" 18" 18" 18" 54" 14-3/8" 14-3/8" 18" 18" 60" 12" 14-3/8" 18" 18" 70" 12" 14-3/8" 18" 18" 72" 12" 14-3/8" 18" 18" 84" 12" 14-3/8" 18" 18" 90" 12" 14-3/8" 18" 18" 92" 12" 14-3/8" 18" 18" 96" 12" 14-3/8" 18" 18" 102" 12" 14-3/8" 18" 18" 24" 90" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 15-5/8" 18" 18" 18" 48" 15-5/8" 15-5/8" 18" 18" 54" 13" 15-5/8" 18" 18" 60" 13" 15-5/8" 18" 18" 70" 11-1 /8" 13" 18" 18" 72" 11-1 /8" 13" 18" 18" 84" 11-1 /8" 13" 18" 18" 90" 11-1 /8" 13" 1 18" 18" 92" 11-1 /8" 13" 18" 18" 96" 11-1 /8" 13" 18" 18" 24" 97.75" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 17-1 /8" 18" 18" 18" 42" 14-5/16" 17-1/8" 18" 18" 48" 14-5/16" 17-1/8" 18" 18" 54" 12-1/4" 14-5/16" 18" 18" 60" 12-1/4" 14-5/16" 18" 18" 70" 10-3/4" 12-1 /4" 18" 18" 72" 10-3/4" 12-1 /4" 18" 18" 84 10-3/4" 12-1/4" 17-1/8" 18" 24" 102" 18" 1 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 15" 18" 18" 18" 48" 12-7/8" 15" 18" 18" 54" 12-7/8" 15" 18" 18" 60" 11-1 /4" 12-7/8" 18" 18" 70" 11-1 /4" 12-7/8" 18" 18" 72" 11-1 /4" 12-7/8" 18" 18" 84" 10" 11-1 /4" 18" 18" Jamb Anchor Spacing Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 108" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 16" 18" 18" 18" 42" 16" 16" 18" 18" 48" 13-11 / 16" 16" 18" 18" 54" 12" 13-11 / 16" 18" 18" 60" 12" 13-11 / 16" 18" 18" 70" 10-11/16" 12" 18" 18" 72" 10-11/16" 12" 18" 18" 24" 114" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 17" 18" 18" 18" 42" 14-9/16" 17" 18" 18" 48" 12-3/4" 14-9/16" 18" 18" 54" 12-3/4" 14-9/16" 18" 18" 60" 11-5/16" 12-3/4" 18" 18" 70" 10-3/16" 11-5/16" 17" 18" 72" 10-3/16" 11-5/16" 17" 18" 24" 120" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 15-7/16" 18" 18" 18" 48" 13-1/2" 15-7/16" 18" 18" 54" 12" 13-1/2" 18" 18" 60" 10-13/16" 13-1/2" 18" 18" 70" 9-13/16" 12" 18" 18" 72" 9-13/16" 10-13/16" 18" 18" 24" 126" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 16-5/16" 18" 18" 18" 42" 14-1/4" 16-5/16" 18" 18" 48" 12-11/16" 14-1/4" 18" 18" 54" 11-3/8" 14-1/4" 18" 18" 60" 11-3/8" 12-11 / 16" 18" 18" 24" 132" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 17-1/8" 18" 18" 18" 42" 15" 17-1/8" 18" 18" 48" 13-5/16" 15" 18" 18" 54" 12" 13-5/16"' 18" 18" 60" 10-15/ 16" 12" 18" 18" 24" 138" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 15-3/4" 18" 18" 18" 42" 14" 15-3/4" 18" 18" 48" 12-5/8" 14" 18" 18" 54" 11-7/16" 14" 18" 18" 60" 10-1/2" 12-5/8" 18" 18" 24" 144" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 16-1/2" 18" 18" 18" 42" 14-11/16" 16-1/2" 18" 18' 48" 13-3/16" 14-11/16" 18" 18" 54" 12" 13-3/16" 18" 18" 60" 1 V 12" 18" 18" 24" 168" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" 24" 180" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 1 18" 18" 18" 42" 18" 1 18" 18" 18" 48" 18" 1 18" 18" 18" 6" MAX. 1 SEE TABLE 6, THIS SHEET f 6" MAX. CENTERLINE WIDTH f FRAME WIDTH - i' 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. 610 LYN/V , f % 0 ENSF r� * : No. 58705 _ yt C/ 9/22/20 STATE OF �pT FCORIOP , ONAI- I \ A. LYNN MILLER, P.E. P.E.# 58705 TABLE 7: Mid -Panel Anchor Quantity Shim Thickness = 1/4'1 Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 48„ 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 4 3 3 72" 4 4 3 3 84" 5 5 4 4 901, 5 6 4 4 92" 5 6 5 5 96" 5 6 5 5 102" 6 7 5 5 108" 6 7 6 1 6 120" 7 8 6 6 132" 8 9 7 7 144" 9 10 8 8 168" 7 8 5 5 180" 7 8 6 6 24" 60„ 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 4 3 3 72 4 5 3 3 84" 5 6 4 4 901, 6 6 4 4 92" 6 7 5 5 96" 6 1 7 5 5 102" 7 8 5 5 108" 7 8 6 6 120" 8 9 6 6 132" 9 11 7 7 144" 10 12 8 8 24" 72„ 1 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 84" 5 6 4 4 901, 6 7 5 4 92" 6 7 5 5 96" 7 8 1 5 5 102" 7 8 1 6 5 108" 8 9 6 6 120" 9 11 7 6 Mid -Panel Anchor Quantity Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D. Anchors Centerline Width Frame Height 24" 78" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 84" 5 6 4 4 901, 6 7 5 4 92" 6 7 5 5 96" 7 8 5 5 102" 7 9 6 5 108" 8 9 6 6 24" 84„ 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 A" 3 3 2 2 60 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 84" 5 6 4 4 901, 6 7 5 4 92" 6 7 5 5 96" 7 8 6 5 102" 1 8 9 6 5 24" 901, 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 84" 5 6 4 4 901, 6 7 5 4 92" 6 8 5 5 96" 7 8 6 5 24" 97-3/4" 1 1 1 1 1 30" 1 1 1 1 36" 1 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 84" 5 6 4 4 24" 102" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 84' 5 6 4 4 Mid -Panel Anchor Quantity Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 108" 1 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 1 2 70" 4 5 3 3 72" 4 5 3 3 24" 114" 1 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 24" 120" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 24" 126" 1 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 24" 132" 1 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 A" 3 3 2 2 60" 3 3 2 2 24" 138" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 24" 1 "1, 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 24" 168" 1 1 1 1 30" 1 1 1 1 36" 1 1 1 1 42" 1 1 1 1 48" 2 1 1 1 24" 180" 1 1 1 1 30" 1 1 1 1 36" 1 1 1 1 1 42" 1 1 1 1 48" 2 1 1 1 m Q rn U) w J 0 2 U z Q L nCI.IT 1- ITCI']I 1- _ uCIV 1 CRLIIVC _ WIDTH _ uCIV 1 CRLIIVC _ WIDTH EQ. EQ. EQ. EQ. EQ. EQ. SEE TABLE 3 OR 4 MID -PANEL MID -PANEL ANCHORS, SEE ANCHORS, SEE TABLE 7, THIS TABLE 7, THIS SHEET SHEET CORNER ANCHORS FOR SILL SHOWN, HEAD ANCHORLESS JAMB CONDITION, SIMILAR, ANCHOR SEE SHEET 3 & QUANTITY MAY VARY TABLES 3 OR 4. PER TABLE, THIS SHEET. 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. 3. MID -PANEL ANCHORS TO BE EQUALLY SPACED, +/- 1/2". 'C Q Z Aar{ U) O 11J Lo N Q O m w ULIJ Lu � O FRAME J U HEIGHT O Q z 0 U � U0,0. �saa nay Q Q Y ao N O o U) o �o J CORNER z ' Q ANCHOR, W U) d SEE SHEET 2 7) J 70 Q O umo,( W LO •� i= z C M V o U) CL 0 E 0, W o W 'ON a� Q 2 U) 9Ma 01,0 U)U)M CO = M O U) _ ® 0 o LL 1 LL >Z_ _ � O >Lu OJ'O C7cQM Q CIO U M = T__ o aaaUS 0 o > U) Lu L CU v � o W 2 H N z z _ rn zoo' N0E- O }^ �oww = ¢Oa =06za Z ti LL O 0 Ocnwm ¢ w w N z" 70_jLL 0 J M Li Li0( 0?ww m O QWz U~a w Q wow ��O U U) Of 0 - U a — z a7l1 Jsaa saua5 \\1lllill!!/�7` LYNNtij�l'% * : No. 58705 - U 9I22120 ]z STATE OF �pT F40RIOP ONAV- A. LYNN MILLER, P.E. P.E.# 58705 TABLE 8: Mid -Panel Anchor Quantity Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 48„ 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 4 3 3 72" 5 4 3 3 84" 6 5 4 4 901, 6 6 4 4 92" 7 6 5 5 96" 7 6 5 5 102" 8 7 5 5 108" 8 7 6 6 120" 9 8 6 6 132" 10 9 7 7 144" 11 10 8 8 168" 9 8 5 5 180" 9 8 6 6 24" 60" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 4 3 3 72 5 5 3 3 84" 7 6 4 4 901, 7 6 4 4 92" 8 7 5 5 96" 8 1 7 5 5 102" 9 8 5 5 108" 9 8 6 6 120" 11 9 6 6 132" 12 11 7 7 144" 13 12 8 8 24" 72„ 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 84" 7 6 4 4 90" 8 7 5 4 92" 8 7 1 5 5 96" 9 8 1 5 5 102" 9 8 1 6 5 108" 10 9 6 6 120" 12 11 7 6 Mid -Panel Anchor Quantity Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D. Anchors Centerline Width Frame Height 24" 78" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 84" 7 6 4 4 90" 8 7 5 4 92" 8 7 5 5 96" 9 8 5 5 102" 10 9 6 5 108"' 11 9 6 6 24" 84„ 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 84" 7 6 4 4 90" 8 7 5 4 92" 8 7 5 5 96" 9 8 6 5 102" 10 9 6 5 24" 90" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 84" 7 6 4 4 90" 8 7 5 4 92" 8 8 5 5 96 9 8 6 5 24" 97-3/4" 1 1 1 1 30 1 1 1 1 36" 2 2 1 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 84' 7 6 4 4 24" 102" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 84" 7 1 6 4 4 Mid -Panel Anchor Quantity Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 108" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 1 2 2 70" 5 5 3 3 72" 5 5 3 3 24" 114" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 24" 120" 1 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 24" 126" 1 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 24" 132" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 24" 138" 1 1 1 1 30" 1 1 1 1 36" 2 1 2 1 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 24" 1,44" 1 1 1 1 30" 1 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 24" 144" 1 1 1 1 30" 1 1 1 1 36" 1 1 1 1 42" 2 1 1 1 48" 2 2 1 1 24" 144" 1 1 1 1 1 1 30" 1 1 1 1 36" 1 1 1 1 42" 2 1 1 1 48" 2 2 1 1 m Q U Cn w J o' 0 S U z Q L nClJTCI']I 1- ITCI']I 1- _ VCIV I CRLIIVC WIDTH - 1 CRLIIVC _ WIDTH r — EQ. EQ. EQ. EQ. EQ. EQ. SEE TABLE 3 OR 4 MID -PANEL MID -PANEL ANCHORS, SEE ANCHORS, SEE TABLE 8, THIS TABLE 8, THIS SHEET SHEET CORNER ANCHORS FOR SILL SHOWN, HEAD ANCHORLESS JAMB CONDITION, SIMILAR, ANCHOR SEE SHEET 3 & QUANTITY MAY VARY TABLES 3 OR 4. PER TABLE, THIS SHEET. 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. 3. MID -PANEL ANCHORS TO BE EQUALLY SPACED, +/- 1/2". 'C Q Z nay U) O W N IN LO Q O m W ULij Lu � O FRAME J U HEIGHT O 00 z 0 uoi}duuuaa na y Q 0 _ Q Y ao N O O U) � o 0 � J CORNER z ' Q ANCHOR, W U d SEE SHEET 2 J 70 Q O umo,( '- d y W LO • = z II) CM V o U)0 0 W o W 'ON a� L Quo U)DMa O � U) CO U. = M O '^ ® 0 6O LL ILL Z =rn 0 ��W^ O J 0 (� r, Q O U M = o Z /aaUS 0 Lu o v F- 6 0 H N z Z _ cliC)zEE°' N00t * p a,°us } ^ 0 W W = Q0N =xsZo Z) O ILL O 0M OcnIm 2 W W N z" >_0_j3: 2LL 0 J M W U U 0? W W m O Q�z U�H0 W Q W O W O U F Of o > U o z a� Ilusaa saua5 LYNNtij�l'% L�CENSF r� * : No. 58705 - 4'1'9/22/20 pT STATE OF ��1, 0NAL 1 \ ` A. LYNN MILLER, P.E. P.E.# 58705 TARI F Q Mullion DP, psf Average Centerline Width Frame Height 5" Unreinforced Mullion 5" Reinforced Mullion 7" Unreinforced HD Mullion 7" Reinforced HD Mullion 24" 48„ +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +70/-80 +90/-120 +70/-70 +60/-75 60" +70/-80 +90/-120 +70/-70 +60/-75 70" +70/-80 +90/-120 +70/-70 +60/-75 72" +70/-80 +90/-120 +70/-70 +60/-75 84" +70/-80 +90/-120 +70/-70 +60/-75 90" +70/-80 +90/-120 +70/-70 +601-75 92" +70/-80 +90/-120 +70/-70 +60/-75 96" +70/-80 +90/-120 +70/-70 +60/-75 102" +90/-120 +70/-70 +60/-75 108" +90/-120 +70/-70 +60/-75 120" +90/-120 +70/-70 +60/-75 132" +90/-100 +70/-70 +60/-75 144" +90/-100 +70/-70 +60/-75 1 88" +60/-75 180" +60/-75 24" 60 +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +70/-80 +90/-120 +70/-70 +60/-75 60" +70/-80 +90/-120 +70/-70 +60/-75 70" +70/-80 +90/-120 +70/-70 +60/-75 72" +70/-80 +90/-120 +70/-70 +60/-75 84" +90/-120 +70/-70 +60/-75 90" +90/-120 +70/-70 +60/-75 92" +90/-120 +70/-70 +60/-75 96" +90/-120 +70/-70 +60/-75 102" +90/-100 +70/-70 +60/-75 108" +90/-100 +70/-70 +60/-75 120" +90/-100 +70/-70 +60/-75 132" +70/-70 +60/-75 144" +70/-70 +60/-75 24" 72„ +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +70/-80 +90/-120 +70/-70 +60/-75 60" +70/-80 +90/-120 +70/-70 +60/-75 70" +90/-120 +70/-70 +60/-75 72" +90/-120 +70/-70 +60/-75 84" +90/-100 +70/-70 +60/-75 90" +90/-100 +70/-70 +60/-75 92" +90/-100 +70/-70 +60/-75 96" +90/-100 +70/-70 +60/-75 102" +70/-70 +6UT75 108" +70/-70 +60/-75 120" +70/-70 +60/-75 Mullion DP, psf Average Centerline Width Frame Height 5" Unreinforced Mullion 5" Reinforced Mullion 7" Unreinforced HD Mullion 7" Reinforced HD Mullion 24" 78" +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +70/-80 +90/-120 +70/-70 +60/-75 60" +70/-80 +90/-120 +70/-70 +60/-75 70" +90/-120 +70/-70 +60/-75 72" +90/-120 +70/-70 +60/-75 84" +90/-100 +70/-70 +60/-75 90" +90/-100 +70/-70 +60/-75 92" +90/-100 +70/-70 +60/-75 96" +70/-70 +60/-75 102" +70/-70 +60/-75 108" +70/-70 +60/-75 24" 84„ +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +70/-80 +90/-120 +70/-70 +60/-75 60" +90/-120 +70/-70 +60/-75 70" +90/-100 +70/-70 +60/-75 72" +90/-100 +70/-70 +60/-75 84" +90/-100 +70/-70 +60/-75 90" +70/-70 +60/-75 92" +70/-70 +60/-75 96" +70/-70 +60/-75 102" +70/-70 +60/-75 24" 90" +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +90/-120 +70/-70 +60/-75 60" +90/-120 +70/-70 +60/-75 70" +90/-100 +70/-70 +60/-75 72" +90/-100 +70/-70 +60/-75 84" +70/-70 +60/-75 90" +70/-70 +60/-75 92" +70/-70 +60/-75 96" +70/-70 +60/-75 24" 97-3/4" +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +90/-120 +70/-70 +60/-75 60" +90/-100 +70/-70 +60/-75 70" +90/-100 +70/-70 +60/-75 72" +90/-100 +70/-70 +60/-75 84" +70/-70 +60/-75 24" 102" +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/- 55 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +68.3/-78.1 +90/-120 +70/-70 +60/-75 48" +90/-120 +70/-70 +60/-75 54" +90/-120 +70/-70 +60/-75 60" +90/-100 +70/-70 +60/-75 70" +90/-100 +70/-70 +60/- 55 72" F +70/-70 84" +70/-70 +60/-75 Mullion DP, psf Average Centerline Width Frame Height 5" Unreinforced Mullion 5" Reinforced Mullion 7" Unreinforced HD Mullion 7" Reinforced HD Mullion 24" 108" +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +65.6/-74.9 +90/-120 +70/-70 +60/-75 42" +57.1/-65.3 +90/-120 +70/-70 +60/-75 48" +90/-120 +70/-70 +60/-75 54" +90/-100 +70/-70 +60/-75 60" +90/-100 +70/-70 +60/-75 70" +70/-70 +60/-75 72" +70/-70 +60/-75 24" 114" +70/-80 +90/-120 +70/-70 +60/-75 30" +65.8/-75.2 +90/-120 +70/-70 +60/-75 36" +55.5/-63.4 +90/-120 +70/-70 +60/-75 42" +90/-120 +70/-70 +60/-75 48" +90/-120 +70/-70 +60/-75 54" +90/-100 +70/-70 +60/-75 60" +90/-100 +70/-70 +60/-75 70" +70/-70 +60/-75 72" +70/-70 +60/-75 24" 120" +69.7/-79.6 +90/-120 +70/-70 +60/-75 30" +56.2/-64.3 +90/-120 +70/-70 +60/-75 36" +47.4/-54.2 +90/-120 +70/-70 +60/-75 42" +90/-120 +70/-70 +60/-75 48" +90/-120 +70/-70 +60/-75 54" +90/-100 +70/-70 +60/-75 60" +90/-100 +70/-70 +60/-75 70" +70/-70 +60/-75 72" +70/-70 +60/-75 24" 126" +60.1/-68.7 +90/-120 +70/-70 +60/-75 30" +48.5/-55.4 +90/-120 +70/-70 +60/-75 36" +40.8/-46.6 +90/-120 +70/-70 +60/-75 42" +90/-116.1 +70/-70 +60/-75 48" +90/-100 +70/-70 +60/-75 54" +84/-93.4 +70/-70 +60/-75 60" +70/-70 +60/-75 24" 132" +52.2/-59.6 +90/-120 +70/-70 +60/-75 30" +42.1/-48.1 +90/-120 +70/-70 +60/-75 36" +90/-116.1 +70/-70 +60/-75 42" +90/-100.6 +70/-70 +60/-75 48" +80.5/-89.4 +70/-70 +60/-75 54" +72.6/-80.6 +70/-70 +60/-75 60" +70/-70 +60/-73.4 24" 138" +45.6/-52.1 +90/-120 +70/-70 +60/-75 30" +36.7/42 +90/-120 +70/-70 +60/-75 36" +90/-101.3 +70/-70 +60/-75 42" +79.2/-88 +70/-70 +60/-75 48" +70.1/-77.9 +70/-70 +60/-75 54" +70/-70 +60/-75 60" +70/-70 +60/-69.3 24" 144" +40.1/-45.8 +90/-120 +70/-70 +60/-75 30" +32.3/-36.9 +90/-105.9 +70/-70 +60/-75 36" +80.3/-89.2 +70/-70 +60/-75 42" +69.5/-77.2 +70/-70 +60/-75 48" +61.5/-68.3 +70/-70 +60/-75 54" +70/-70 +60/-71.1 60" +70/-70 +60/-65.7 24" 168" +60/-75 30" +60/-75 36" +60/-75 42" +60/-72.8 48" +60/-65 24' 180" +60/-75 30" +60/-75 36" +60/-75 42" +60/-67.3 48" +60/-60 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT). THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. FOR SIZES NOT SHOWN, ROUNDUP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. AVERAGE CENTERLINE + CENTERLINE CENTERLINE = WIDTH 1 WIDTH 2 WIDTH 2 FRAME HEIGHT rt CENTERLINE CENTERLINE WIDTH 1 '1 WIDTH 2 REINFORCEMENT PART # 10, IF REQUIRED, SEE TABLE 9 INTERIOR MULLIONS OPTIONAL HORIZONTF MULLION AVERAGE CENTERLINE CENTERLINE = WIDTH 1 WIDTH 2 CENTERLINECENTERLINE L1Ni� WIDTH WIDTH 2 FRAME HEIGHT REINFORCEMENT PART # 10, IF REQUIRED, SEE TABLE 9 ANCHORLESS JAMB/MULLION \\1,NII �L 1KN . or-E ` * No.: �Q STAI O S A. LYNN P P. E.f 1111,/` CNN NSF '•l`��i ,870s 2/20 z E OF 1ILLER, P.E. 58705 ASSEMBLY DETAILS ALL DETAILS SHOWN FROM THE EXTERIOR U HORI, EXTERIOR 5.000" 2.000" .094" 10 JAMB/MULLION 4.596" .094" 1.385" O4HORIZONTAL POCKET FILLER 3.878" .062" 1.000" 07 9/16" LAMI GLASS STOP 5.000" 2.000" .094" 02 HEAD/SILL/HORIZONTAL 4.192" - 094" .454" OFLAT FILLER PLATE (USED WITH NON-REINF. MULLION) 3.193" �{ .062" 1.000" 01-1/4" IG GLASS STOP' 7.000" 4.596" .094" 1.385" ( VERTICAL POCKET FILLER 4.192" - � .454" .094" O6 FLAT FILLER PLATE (USED WITH REINFORCED MULLION) 5.000" - 094" 1.250" ODOOR TRANSOM ADAPTER F- - 313" 500" .094" 4.500" 2.000" 10 STEEL REINFORCEMENT 11 HD JAMB/MULLION TABLE 10: Item# Part# T Description Material 1 CGIC-206 Jamb/Mullion 6063-T6 Alum. 2 CGIC-201 Head/Sill/Horizontal 6063-T6 Alum. 3 CGIC-207 Vertical Pocket Filler 6063-T6 Alum. 4 CGIC-202 Horizontal Pocket Filler 6063-T6 Alum. 5 CGIC-203 Flat Filler Plate (used with non-reinf. mullion) 6063-T6 Alum. 6 CGIC-003 Flat Filler Plate (used with reinforced mullion) 6063-T6 Alum. 7 CGIC-204 9/16" Lami Glass Stop 6063-T6 Alum. 8 CGIC-205 1-1/4" IG Glass Stop 6063-T6 Alum. 9 CGIC-212 Door Transom Adapter 6063-T6 Alum. 10 CGIC-209 Steel Reinforcement A36 Steel 11 CGIC-208 HD Jamb/Mullion 6063-T6 Alum. 13 CGIC-214 HD Jamb Cover 6063-T6 Alum. 14 CGIC-213 HD Mullion Coker 6063-T6 Alum. 30 1652 Setting Block 3/16" x 7/16" x 4", Duro = 85 +/-5 EPDM 31 1704 IG Setting Block 3/16" x 1-3/32" x 4", Duro = 85 +/-5 EPDM 36 Thermo -plastic Spacer System varies 37 Foam Spacer System varies 38 Metal Reinforced Foam Spacer System varies 39 Metal Spacer System varies 40 CGIC-006 Glass Stop Gasket (@ beading, duro. = 65 +/-5) EPDM 41 CGIC-007 Spacer Gasket (@ glazing leg, duro. = 80 +/-5) Santoprene 42 Silicone Backbedding: Dow 791, 983, 995, GE7700 50 CGIC-010 Frame Assembly Screw (#12 x 1-1/2" Hex Washer) Stainless Steel 2.078" r� y Ctj •� � z T ya_ - o 0, o w zX°° .062" - 0'` ¢moo = M C 13 HD JAMB COVER ® 000E� O o � >z_ Q OLu J ' CC) 01- 2.078" CD � z Y U J � Z H Z N 3.000" J } ^ O ' W W =x>s0a Q0v > E23:20 m0U- }O-1U- .062" - Lwvui pzww Q � Z U a wc)> H2O 14 HD MULLION COVER a - z Mi uoi40u3Saa na y Y 00 U N O o T- U) T- 0 aC:) U) J Q W U Q J d LL �e Q O umoj(j N W M W � oN W DMa �CD LL. O O 0 CD Z p aaauS 07 >z n Z z * X p a-TS 7a LLI o M m Q U) * : No. 58705 44-9 %22/20 441 STATE OF ((/ �(ORIOP. ��1111111I11� A. LYNN MILLER, P.E. P.E.# 58705