HomeMy WebLinkAboutAPPROVED PV Plans Stamped V2-Zapata, Alejandro(1)PV-1FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO.SHEET:REVISIONSJOB NO:F100991DESIGNED BY:G.D.CLIENT:ALEJANDRO ZAPATA5413 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 204-1583SYSTEM:SYSTEM SIZE (DC): 36 X 350 = 12.600 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X LONGI SOLAR:LR4-60HPB-350MOPTIMIZERS: 36 X SOLAREDGE P401INVERTER: SOLAREDGE SE10000H-US [SI1]DATE:8/24/2021THIS PROJECT COMPLIES WITH THE FOLLOWING:2020 7TH EDITION FLORIDA BUILDING CODE: BUILDING2020 7TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL2020 7TH EDITION FLORIDA BUILDING CODE: MECHANICAL2020 7TH EDITION FLORIDA BUILDING CODE: PLUMBING2020 7TH EDITION FLORIDA BUILDING CODE: FUEL GAS2020 7TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION 2020 7TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING 2020 7TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY2017 NATIONAL ELECTRIC CODE (NEC)AS ADOPTED BY ST. LUCIE COUNTYSITE LOCATIONCODES:VICINITY MAP:TABLE OF CONTENTS:CONSTRUCTION NOTES:PHOTOVOLTAIC SYSTEMPV-1SITE LOCATIONPV-2SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-2BSTRUCTURAL CALCULATIONSPV-3MOUNTING DETAILSPV-4THREE LINE DIAGRAMPV-5CONDUCTOR CALCULATIONSPV-6EQUIPMENT & SERVICE LISTPV-7LABELSPV-7ASITE PLACARDPV-8OPTIMIZER CHARTPV-9SAFETY PLANPV-10SAFETY PLANAPPENDIXMANUFACTURER SPECIFICATION SHEETSCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS ANDARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENTPOSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY AREMOUNTED.MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION INACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PERSECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANYEXCAVATION TAKING PLACEPHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROMDC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A).SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITHREQUIREMENTS OF ART. 690 OF THE 2020 NECTHE EXISTING MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFERUTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEMSOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDSINSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITATTACHED TO THE ROOF USING CONDUIT MOUNT.SITE LOCATION MSPINVJBUMACSITE PLANSCALE: 0.0047151TOTAL ROOF AREA RIDGE SETBACK CALCS:TOTAL ROOF AREA: 2358 SQ FTSINGLE MODULE AREA: 18.05 SQ FTTOTAL NUMBER OF MODULES: 36TOTAL AREA OF MODULES: 649.80 SQ FTROOF COVERAGE: 27.56%FIRE SPRINKLERS : NOPV-2FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO.SHEET:REVISIONSJOB NO:F100991DESIGNED BY:G.D.CLIENT:ALEJANDRO ZAPATA5413 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 204-1583SYSTEM:SYSTEM SIZE (DC): 36 X 350 = 12.600 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X LONGI SOLAR:LR4-60HPB-350MOPTIMIZERS: 36 X SOLAREDGE P401INVERTER: SOLAREDGE SE10000H-US [SI1]DATE:8/24/2021THIS SYSTEM DESIGNED WITH:WIND SPEED: 152WIND EXPOSURE: CROOF AREA: 2358 SQ FTSITE PLANLEGEND:OBSTRUCTIONPIPE VENTMODULESCONDUITSETBACKMSP AC JBACDISCONNECTMSPJUNCTIONBOXINVINVERTERPMPRODUCTIONMETERROOF LINEPROPERTY LINEDRIVEWAYHICKORY DRIVE(E) MAIN SERVICE PANEL(N) 36 LONGI SOLAR: LR4-60HPB-350M(E) UTILITY METER(N) JUNCTION BOX(E) SHED(N) SOLAREDGE SE10000H-US [SI1]INVERTER WITH RAPID SHUTDOWN(N) UTILITY DISCONNECT EATON DG222NRB81'-1"142'-4"52'-9"12'-5"142'-4"44'-8"11'-7"54'-5"14'-1" 15'-11" 81'-1" MSPINVJBUMAC PV-2AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO.SHEET:REVISIONSJOB NO:F100991DESIGNED BY:G.D.CLIENT:ALEJANDRO ZAPATA5413 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 204-1583SYSTEM:SYSTEM SIZE (DC): 36 X 350 = 12.600 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X LONGI SOLAR:LR4-60HPB-350MOPTIMIZERS: 36 X SOLAREDGE P401INVERTER: SOLAREDGE SE10000H-US [SI1]DATE:8/24/2021ROOF PLANSCALE: 0.0121631MODIFIED SETBACKS PROPOSED AT RIDGE:TOTAL ARRAY AREA = 649.8 SFTOTAL ROOF AREA = 2358 SFTOTAL ARRAY AREA AS A % TO ROOF AREA = 27.56%27.56% < 33%NOTES:1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES3.JUNCTION BOX IS MOUNTED TO THE RAIL.ROOF AREA: 2358 SQ FTTHIS SYSTEM DESIGNED WITH:WIND SPEED: 152WIND EXPOSURE: CROOF PLAN WITH MODULES LAYOUTLEGEND:OBSTRUCTIONPIPE VENTMODULESCONDUITSETBACKMSP AC JBACDISCONNECTMSPJUNCTIONBOXINVINVERTERPMPRODUCTIONMETERFIRE ACCESSPATHWAYS(E) MAIN SERVICE PANEL(N) 36 LONGI SOLAR: LR4-60HPB-350M(N) SOLAREDGE SE10000H-US [SI1]INVERTER(N) JUNCTION BOX(E) UTILITY METERROOF LINEFIRE ACCESSPATHWAYS(N) AC DISCONNECT EATON DG222NRB3'-0" 3'-0"3'-0"By Yuri at 6:29:30 AM, 9/24/2021 ROOF AREA STATEMENTROOFMODULE QUANTITYROOF PITCHARRAY PITCHAZIMUTHROOF AREAARRAY AREA13016°16°90°955 SQ FT541.5 SQ FT2616°16°270°909 SQ FT108.3 SQ FTPV-2BFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO.SHEET:REVISIONSJOB NO:F100991DESIGNED BY:G.D.CLIENT:ALEJANDRO ZAPATA5413 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 204-1583SYSTEM:SYSTEM SIZE (DC): 36 X 350 = 12.600 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X LONGI SOLAR:LR4-60HPB-350MOPTIMIZERS: 36 X SOLAREDGE P401INVERTER: SOLAREDGE SE10000H-US [SI1]DATE:8/24/2021ROOF DETAILS:TOTAL ROOF AREA: 2358 SQ FTARRAY COVERAGE: 27.56%SYSTEM DISTRIBUTED WEIGHT: 2.31 LBSS-5!: PROTEA POINT-LOAD: 23.08 LBSROOF DETAILSBy Yuri at 6:29:35 AM, 9/24/2021 PROTEABRACKETPROTEABRACKET(E) TRAPEZOIDAL METALROOF PROFILE1" SELF TAPPING SCREWFACTORY APPLIEDEPDM WITH STICKY ADHESIVE(E) TRAPEZOIDAL METALROOF PROFILE(N) LONGI SOLAR:LR4-60HPB-350MUNIRAC SM LIGHT RAIL SOLAR MOUNTRACKING SYSTEMGROUNDING END/MIDCLAMP2X4 TRUSS @ 24" O.C.UNIRAC SM LIGHT RAIL RACKING SYSTEM(N) LONGI SOLAR: LR4-60HPB-350M2X4 TRUSS @ 24" O.C.ROOF ATTACHMENT'ATTACHMENT DETAILScale: NTSSOLAR PV ARRAY SECTION VIEWScale: NTSPARTIAL ROOF FRAMING PLANScale: NTSPV-3FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO.SHEET:REVISIONSJOB NO:F100991DESIGNED BY:G.D.CLIENT:ALEJANDRO ZAPATA5413 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 204-1583SYSTEM:SYSTEM SIZE (DC): 36 X 350 = 12.600 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X LONGI SOLAR:LR4-60HPB-350MOPTIMIZERS: 36 X SOLAREDGE P401INVERTER: SOLAREDGE SE10000H-US [SI1]DATE:8/24/2021MOUNTING DETAILS2By Yuri at 6:29:40 AM, 9/24/2021 JUNCTIONBOXSOLAREDGE P401 POWER OPTIMIZERSSTRING-12 - #10 AWG, PV WIRE1 - #6 AWG IN FREE AIR OR#8 AWG MUST BE IN EMT CONDUITSTRING-3SOLAREDGE P401POWER OPTIMIZERS4 - #10 AWG, PV WIRE1 - #6 AWG IN FREE AIR OR#8 AWG MUST BE IN EMTCONDUIT16 LONGI SOLAR: LR4-60HPB-350M10 LONGI SOLAR: LR4-60HPB-350MSTRING-210 LONGI SOLAR: LR4-60HPB-350M2 - #10 AWG, PV WIRESOLAREDGE P401POWER OPTIMIZERS6 - #10 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" ORLARGER EMT CONDUITUM(E) 150A / 2PMAIN BREAKER(TOP FED)(E) 150A RATEDMAIN SERVICE PANEL1PH, 120/240V 60HZ(E) UTILITYMETER(N) LINESIDE TAP VIA ULLISTED CONNECTORS1 - #6 GEC, BARE COPPERFREE AIR BONDEDEXISTING UFER TIE INTO UTILITYOVERHEADFEED(N) 60A FUSEDAC DISCONNECTEATON DG222NRB2 - 60 AMP FUSES3 - #8 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMT CONDUITA TAPBOX MAY BE USED IN LIEU OF PERFORMING THE LINESIDETAP IN THE MAIN SERVICE PANEL. THIS IS DEPENDENT UPON SITECONDITIONS.3 - #6 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMT CONDUIT(N) SOLAREDGESE10000H-US [SI1]INVERTERACDCRAPIDSHUTDOWNSWITCHCONNECT TO EXISTING UFERNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONSBACKFEED FUSE SIZINGMAX. CONTINUOUS OUTPUT 42.00A @ 240V42.00X1.25=53AMPS60A FUSES - OKPV-4FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO.SHEET:REVISIONSJOB NO:F100991DESIGNED BY:G.D.CLIENT:ALEJANDRO ZAPATA5413 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 204-1583SYSTEM:SYSTEM SIZE (DC): 36 X 350 = 12.600 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X LONGI SOLAR:LR4-60HPB-350MOPTIMIZERS: 36 X SOLAREDGE P401INVERTER: SOLAREDGE SE10000H-US [SI1]DATE:8/24/2021THREE LINE DIAGRAM PV-5FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO.SHEET:REVISIONSJOB NO:F100991DESIGNED BY:G.D.CLIENT:ALEJANDRO ZAPATA5413 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 204-1583SYSTEM:SYSTEM SIZE (DC): 36 X 350 = 12.600 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X LONGI SOLAR:LR4-60HPB-350MOPTIMIZERS: 36 X SOLAREDGE P401INVERTER: SOLAREDGE SE10000H-US [SI1]DATE:8/24/2021CONDUCTOR CALCULATIONS1DCMODULETOOPTIMIZERROOF / FREE-AIR210401140.0017.442DCOPTIMIZERTOJUNCTION BOXROOF / FREE-AIR210401140.0018.753DCJUNCTION BOXTOINVERTEREXTERIOR WALL6104010.832.0018.754ACINVERTERTOAC DISCONNECTEXTERIOR WALL38551155.0052.505ACAC DISCONNECTTOPOIEXTERIOR WALL36751175.0052.50WIRE SCHEDULERACEWAY#EQUIPMENTWIRE LOCATIONCONDUCTORQTY.AWGWIRESIZESTARTINGALLOWABLEAMPACITY @ 90°C310.15(B)(16)TEMPERATURECORRECTIONFACTOR310.15(B)(2)(a)ADJUSTMENTFACTOR FORMORE THAN 3CONDUCTORS310.15(B)(3)(a)ADJUSTEDCONDUCTORAMPACITY@ 90°CMAXIMUMCURRENTAPPLIED TOCONDUCTORSIN RACEWAY MATERIAL LIST:PV-6FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO.SHEET:REVISIONSJOB NO:F100991DESIGNED BY:G.D.CLIENT:ALEJANDRO ZAPATA5413 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 204-1583SYSTEM:SYSTEM SIZE (DC): 36 X 350 = 12.600 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X LONGI SOLAR:LR4-60HPB-350MOPTIMIZERS: 36 X SOLAREDGE P401INVERTER: SOLAREDGE SE10000H-US [SI1]DATE:8/24/2021QTY.PARTPART #DESCRIPTION36MODULES114-350LONGI SOLAR: LR4-60HPB-350M36OPTIMIZERS130-401SOLAREDGE P401 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON1JUNCTION BOX480-276600VDC NEMA 3R UL LISTED JUNCTION BOX2CONNECTORS240-300STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE)2CONNECTORS240-301STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE)1INVERTER120-101SOLAREDGE SE10000H-US [SI1] 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN1AC DISCONNECT323-06160A RATED 240VAC NEMA 3R UL LISTED1FUSES330-06060A FUSE 1 PH 240VAC1FUSE REDUCER330-510100A-60A FUSE REDUCER65ROOF ATTACHMENT 1240-401S-5!: PROTEA17RAIL 1211-100UNIRAC SM LIGHT RAIL 168 INCH (TOTAL 236 FEET NEEDED)36RAIL HARDWARE 1261-517BND T-BOLT AND NUT SS38MODULE CLAMPS 1221-101SM MIDCLAMP PRO DRK38MODULE CLAMPS 1221-202SM ENDCLAMP PRO W/ END CLAMP13SPLICE 1261-600BND SPLICE BAR PRO SERIES MILL38MLPE MOUNT 1261-510MICRO MNT BND TBOLT SS10ACCESSORIES 1211-202E-BOSS CONDUIT MOUNT COMP KIT20ACCESSORIES 1211-200E-BOSS RAIL TRAY7ACCESSORIES 1211-206E-BOSS BRIDGE TRAY11ACCESSORIES 1211-207E-BOSS BRIDGE CLIPS34GROUNDING LUG 1260-300BURNDY GROUND WEEB-LUG62L-FOOT 1241-100UNIRAC L-FOOT SERRATED W/T-BOLT CLEAR (KIT)BREAKER SIZES:SERVICE LIST:NONEEQUIPMENT & SERVICE LIST 1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINEWORK.C.ARIAL FONT.3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED INTHE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENTWITH POP-RIVETS OR SCREWSNOTES:PV-7FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO.SHEET:REVISIONSJOB NO:F100991DESIGNED BY:G.D.CLIENT:ALEJANDRO ZAPATA5413 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 204-1583SYSTEM:SYSTEM SIZE (DC): 36 X 350 = 12.600 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X LONGI SOLAR:LR4-60HPB-350MOPTIMIZERS: 36 X SOLAREDGE P401INVERTER: SOLAREDGE SE10000H-US [SI1]DATE:8/24/2021LABELSM690.13(B)MAIN PHOTOVOLTAICSYSTEM DISCONNECTAC NEC 690.13(B)INVERTERDCSOLAR PV DC CIRCUITEVERY 10' ON CONDUIT AND ENCLOSURES706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANEL!WARNINGSINGLE 120-VOLT SUPPLYDO NOT CONNECTMULTIWIRE BRANCH CIRCUITSNEC 710.15(C) & 692.9 (C)NEC 690.15 (B) & NEC 690.33(D)(2)DO NOT DISCONNECTUNDER LOADNEC 705.12(D) & NEC 690.59!CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDNEC 705.12(D) & NEC 690.59NEC 705.12(C) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGPOWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE.!WARNINGARC FLASH AND SHOCK HAZARDAPPROPRIATE PPE REQUIRED24 INCH3480 VAC42 INCH12 INCH1 INCHFLASH HAZARD BOUNDARYCAL/CM^2 FLASH HAZARD AT 18 INCHESSHOCK HAZARD WHEN COVER IS REMOVEDLIMITED APPROACHRESTRICTED APPROACH - 500 V CLASS 00 GLOVESPROHIBITED APPROACH - 500 V CLASS 00 GLOVESLOCATION:5413 HICKORY DRIVE,FORT PIERCE, FL 34982PHOTOVOLTAICAC DISCONNECTPHOTOVOLTAIC AC DISCONNECTRATED AC OUTPUT CURRENT:NOMINAL OPERATING AC VOLTAGE:42.00A240V!WARNINGTHIS EQUIPMENT FED BYMULTIPLE SOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEED AMPACITY OF BUSBARNEC 690.54NEC 705.12(B)(3)(3)NEC 706.15(C) AND NEC 110.16PM NEC 705.12(D) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENTNEC 690.31(E)PHOTOVOLTAIC POWER SOURCEEVERY 10' ON CONDUIT AND ENCLOSURESNEC 690.31(O)(2)NEC 690.31(D)(2) NEC 690.13(B)PHOTOVOLTAICDC DISCONNECT706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHT NEC 690.53MAXIMUM DC VOLTAGEOF PV SYSTEMARRAYJ/BNEC 690.31(G)(3) & (4)706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEM690.56(C)(3)MAXIMUM VOLTAGEMAXIMUM CIRCUIT CURRENTMAX DC-DC CONVERTEROUTPUT CURRENTVAA2748015 MSPINVJBUMAC JUNCTION BOX36 PV MODULEHICKORY DRIVEAC DISCONNECTMAIN SERVICE PANELINVERTER EQUIPPEDWITH RAPID SHUTDOWNUTILITY METERCAUTION:MULTIPLE SOURCES OF POWER LOCATED AS SHOWN.DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES6X8" TYP - NEC 705.10PV-7AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO.SHEET:REVISIONSJOB NO:F100991DESIGNED BY:G.D.CLIENT:ALEJANDRO ZAPATA5413 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 204-1583SYSTEM:SYSTEM SIZE (DC): 36 X 350 = 12.600 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X LONGI SOLAR:LR4-60HPB-350MOPTIMIZERS: 36 X SOLAREDGE P401INVERTER: SOLAREDGE SE10000H-US [SI1]DATE:8/24/20211.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C.AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.NOTES:SITE PLACARD 123456789101-1011-2021-3031-4041-5051-60123456789101-1011-2021-3031-4041-5051-60HICKORY DRIVE PV-8FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO.SHEET:REVISIONSJOB NO:F100991DESIGNED BY:G.D.CLIENT:ALEJANDRO ZAPATA5413 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 204-1583SYSTEM:SYSTEM SIZE (DC): 36 X 350 = 12.600 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X LONGI SOLAR:LR4-60HPB-350MOPTIMIZERS: 36 X SOLAREDGE P401INVERTER: SOLAREDGE SE10000H-US [SI1]DATE:8/24/2021SOLAREDGE OPTIMIZER CHARTOPTIMIZER CHART HICKORY DRIVE SAFETY PLANMARK UP KEYINSTRUCTIONS:1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2.SAFETY PLAN MUST BE MARKED BEFORE JOBSTARTS AS PART OF THE PRE-PLAN3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE& MAKE NOTES ON THE JHA SHEETIN CASE OF EMERGENCYNEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINICNAME: _______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATIONNAME: _______________________________________________ADDRESS: ___________________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THESAFETY PLAN AND SIGN INDICATING THAT THEY AREAWARE OF THE HAZARDS ON-SITE AND THE PLAN FORWORKING SAFELY. NAME SIGNATURE__________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEPGRADE OR GROUND LEVELOBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2OPV-9FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO.SHEET:REVISIONSJOB NO:F100991DESIGNED BY:G.D.CLIENT:ALEJANDRO ZAPATA5413 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 204-1583SYSTEM:SYSTEM SIZE (DC): 36 X 350 = 12.600 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X LONGI SOLAR:LR4-60HPB-350MOPTIMIZERS: 36 X SOLAREDGE P401INVERTER: SOLAREDGE SE10000H-US [SI1]DATE:8/24/2021SAFETY PLAN JOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder Access·Ladders must be inspected before each use.·Extension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.·Extension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.·A-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).·Additional notes:Mobile Equipment·Only Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.·Type(s) of mobile equipment (Type/Make/Model):·Qualified operator(s):Material Handling and Storage·Materials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall Protection·A site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.·First-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.·FPCP (name and title):·FPU and LPD (name and title):Electrical Safety·The Electrical Qualified Person (EQP) is required onsite toperform electrical work.·All electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.·Service drops and overhead electrical hazards will be indentifiedand protected from contact, as neccessary.·EQP (name and tile):Public Protection·The safety of the Client and Public must be maintained at alltimes.·The Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.·Company, Client and Public property shall be protected fromfalling objects.·Pets (including dogs) shall be secured by their owners prior towork start.·The Client should not leave pets, family members, or others incharge or care of Employees, Contractors, or TemporaryWorkers.·Crew leader responsible for communication with the client:·Client and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety Briefing·All employees onsite shall be made aware of the specific hazardsof this project and review this HJA during a pre-job briefing, andtheir signature indicates awareness of site conditions and theplan to eliminate any hazards identified prior to and during theproject.·Crew leader (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):Airborne Contaminants:·Asbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)·Asbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.·If yes, list specific tasks and protection in place:Weather and Environment·The site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)·The site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, by checkingat the ground and on any elevated work surface (ex, rooftop)prior to work start, at midday and prior to solar panel staging on aroof.·Elevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.·Forecasted weather maximum temp (degrees f):Heat Related Illness Prevention·Employees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.·Shade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.·New employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.·Employees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.·Cool Vests are encouraged for all employees at all times duringperiods of high heat.·Identify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?·If offsite replenish is necessary, where will you go to replenishwater (location/address):·Who will replenish the drinking water (name):Restroom facilities·Employees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.·Restroom facilities will be (circle one): Onsite - Offsite·If Offsite, add location name and address:Incident Reporting Procedure·Contact your Site SupervisorName:Phone:·Contact your ManagerName:Phone:·Contact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:PV-10FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO.SHEET:REVISIONSJOB NO:F100991DESIGNED BY:G.D.CLIENT:ALEJANDRO ZAPATA5413 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 204-1583SYSTEM:SYSTEM SIZE (DC): 36 X 350 = 12.600 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X LONGI SOLAR:LR4-60HPB-350MOPTIMIZERS: 36 X SOLAREDGE P401INVERTER: SOLAREDGE SE10000H-US [SI1]DATE:8/24/2021SAFETY PLAN POWER OPTIMIZER solaredge.comPV power optimization at the module-level6SHFLÀFDOO\GHVLJQHGWRZRUNZLWK6RODU(GJHLQYHUWHUV8SWRPRUHHQHUJ\)OH[LEOHV\VWHPGHVLJQIRUPD[LPXPVSDFHXWLOL]DWLRQ)DVWLQVWDOODWLRQZLWKDVLQJOHEROW1H[WJHQHUDWLRQPDLQWHQDQFHZLWKPRGXOHOHYHOPRQLWRULQJ0HHWV1(&UHTXLUHPHQWVIRUDUFIDXOWSURWHFWLRQ $)&, DQG3KRWRYROWDLF5DSLG6KXWGRZQ6\VWHP 39566 0RGXOHOHYHOYROWDJHVKXWGRZQIRULQVWDOOHUDQGÀUHÀJKWHUVDIHW\6XSHULRUHIÀFLHQF\  0LWLJDWHVDOOW\SHVRIPRGXOHPLVPDWFKORVVHVIURPPDQXIDFWXULQJWROHUDQFHWRSDUWLDOVKDGLQJPower Optimizer For North America3333325YEARWARRANTYŒ6RODU(GJH7HFKQRORJLHV/WG$OOULJKWVUHVHUYHG62/$5('*(WKH6RODU(GJHORJR237,0,=('%<62/$5('*(DUHWUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI6RODU(GJH7HFKQRORJLHV,QF$OORWKHUWUDGHPDUNVPHQWLRQHGKHUHLQDUHWUDGHPDUNVRIWKHLUUHVSHFWLYHRZQHUV'DWH'61$6XEMHFWWRFKDQJHZLWKRXWQRWLFH  )RUGHWDLOHGᐎULQJVL]LQJLQIRUPDWLRQUHIHUWRKWWSZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVᐎULQJBVL]LQJBQDSGI  ,WLVQRWDOORZHGWRPL[33ZLWK333LQRQHᐎULQJ  ,IWKHLQYHUWHUVUDWHG$&SRZHU•PD[LPXPQRPLQDOSRZHUSHUᐎULQJWKHQWKHPD[LPXPSRZHUSHUᐎULQJZLOOEHDEOHWRUHDFKXSWRWKHLQYHUWHUVPD[LPXPLQSXW'&SRZHU5HIHUWRKWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHSRZHURSWLPL]HUVLQJOHᐎULQJGHVLJQDSSOLFDWLRQQRWHSGI  )RU9JULGLWLVDOORZHGWRLQᐎDOOXSWR:SHUᐎULQJZKHQWKHPD[LPXPSRZHUGL੔HUHQFHEHWZHHQHDFKᐎULQJLV:  )RU9JULGLWLVDOORZHGWRLQᐎDOOXSWR:SHUᐎULQJZKHQWKHPD[LPXPSRZHUGL੔HUHQFHEHWZHHQHDFKᐎULQJLV:Power OptimizerFor North America33333Optimizer model(typical module compatibility)P370(for higher-power 60 and 72-cell modules)P400 (for 72 & 96-cell modules)P401(for high power 60 and 72 cell modules)P485 (for high-voltage modules)P505 (for higher current modules)INPUT5DWHG,QSXW'&3RZHU      :$EVROXWH0D[LPXP,QSXW9ROWDJH 9RFDWORZHᐎWHPSHUDWXUH    (2)(2)9GF03372SHUDWLQJ5DQJH      9GF0D[LPXP6KRUW&LUFXLW&XUUHQW ,VF       $GF0D[LPXP(੕FLHQF\%:HLJKWHG(੕FLHQF\%2YHUYROWDJH&DWHJRU\IIOUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)0D[LPXP2XWSXW&XUUHQW $GF0D[LPXP2XWSXW9ROWDJH  9GFOUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)6DIHW\2XWSXW9ROWDJHSHU3RZHU2SWLPL]HU ” 9GFSTANDARD COMPLIANCE3KRWRYROWDLF5DSLG6KXWGRZQ6\ᐎHP 1(&  1(&  1(& (0&)&&3DUW&ODVV%,(&,(&6DIHW\,(& FODVV,,VDIHW\ 8/0DWHULDO8/9895HVLᐎDQW5R+6YesINSTALLATION SPECIFICATIONS 0D[LPXP$OORZHG6\ᐎHP9ROWDJH  9GF&RPSDWLEOHLQYHUWHUV $OO6RODU(GJH6LQJOH3KDVHDQG7KUHH3KDVHLQYHUWHUV'LPHQVLRQV :[/[+ [[[[[[[[[[[[[[[[[[[[mm LQ:HLJKW LQFOXGLQJFDEOHV      JUOE,QSXW&RQQHFWRU 0&  6LQJOHRUGXDO0&   0&  ,QSXW:LUH/HQJWK        PIW2XWSXW:LUH7\SH&RQQHFWRU 'RXEOH,QVXODWHG0&2XWSXW:LUH/HQJWK PIW2SHUDWLQJ7HPSHUDWXUH5DQJH  WRWR Ü&Ü)3URWHFWLRQ5DWLQJ,31(0$35HODWLYH+XPLGLW\%  5DWHGSRZHURIWKHPRGXOHDW67&ZLOOQRWH[FHHGWKHRSWLPL]HU´5DWHG,QSXW'&3RZHUµ0RGXOHVZLWKXSWRSRZHUWROHUDQFHDUHDOORZHG  1(&UHTXLUHVPD[LQSXWYROWDJHEHQRWPRUHWKDQ9  )RURWKHUFRQQHFWRUW\SHVSOHDVHFRQWDFW6RODU(GJH  )RUGXDOYHUVLRQIRUSDUDOOHOFRQQHFWLRQRIWZRPRGXOHVXVH310'050,QWKHFDVHRIDQRGGQXPEHURI39PRGXOHVLQRQHᐎULQJLQᐎDOOLQJRQH3GXDOYHUVLRQSRZHURSWLPL]HUFRQQHFWHGWRRQH39PRGXOH:KHQFRQQHFWLQJDVLQJOHPRGXOHVHDOWKHXQXVHGLQSXWFRQQHFWRUVZLWKWKHVXSSOLHGSDLURIVHDOV  )RUDPELHQWWHPSHUDWXUHDERYHƒ&ƒ)SRZHUGHUDWLQJLVDSSOLHG5HIHUWR3RZHU2SWLPL]HUV7HPSHUDWXUH'H5DWLQJ7HFKQLFDO1RWHIRUPRUHGHWDLOVPV System Design Using a SolarEdge Inverter(6)(7)Single Phase HD-WaveSingle phaseThree Phase for 208V gridThree Phase for 277/480V grid0LQLPXP6WULQJ/HQJWK 3RZHU2SWLPL]HUV 333   3360D[LPXP6WULQJ/HQJWK 3RZHU2SWLPL]HUV   0D[LPXP1RPLQDO3RZHUSHU6WULQJ   ZLWK6(866(86   (9)  :3DUDOOHO6WULQJVRI'L੔HUHQW/HQJWKVRU2ULHQWDWLRQVYes INVERTERS solaredge.comOptimized installation with HD-Wave technology6SHFLÀFDOO\GHVLJQHGWRZRUNZLWKSRZHURSWLPL]HUV%XLOWLQPRGXOHOHYHOPRQLWRULQJ2XWGRRUDQGLQGRRULQVWDOODWLRQ2SWLRQDO5HYHQXHJUDGHGDWD$16,&&ODVV DFFXUDF\ 5HFRUGEUHDNLQJH඼FLHQF\)L[HGYROWDJHLQYHUWHUIRUORQJHUVWULQJV,QWHJUDWHGDUFIDXOWSURWHFWLRQDQGUDSLGVKXWGRZQIRU1(&DQGSHUDUWLFOHDQG([WUHPHO\VPDOO8/6$FHUWLÀHGIRU&38&5XOHJULGFRPSOLDQFHSingle Phase Inverter with HD-Wave Technologyfor North America6(+866(+866(+866(+866(+866(+866(+8612-25YEARWARRANTYSE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-USOUTPUT Rated AC Power Output 30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V7600 1000011400 @ 240V10000 @ 208VVAMaximum AC Power Output 30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V7600 1000011400 @ 240V10000 @ 208VVAAC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)9999999VacAC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-9-9--9VacAC Frequency (Nominal)59.3 - 60 - 60.5(1)HzMaximum Continuous Output Current @240V12.5 16 21 25 32 42 47.5 AMaximum Continuous Output Current @208V-16-24- -48.5AGFDI Threshold1AUtility Monitoring, Islanding Protection, &RXQWU\&RQÀJXUDEOH7KUHVKROGVYesINPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 WMaximum DC Power @208V - 5100 - 7750 - - 15500 WTransformer-less, Ungrounded YesMaximum Input Voltage480 VdcNominal DC Input Voltage 380 400 VdcMaximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 AdcMaximum Input Current @208V(2)-9-13.5--27AdcMax. Input Short Circuit Current45 AdcReverse-Polarity ProtectionYesGround-Fault Isolation Detection 600k Sensitivity0D[LPXP,QYHUWHU(੕FLHQF\99 99.2 %&(&:HLJKWHG(੕FLHQF\9999 @ 240V98.5 @ 208V%Nighttime Power Consumption< 2.5 WADDITIONAL FEATURESSupported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional)Revenue Grade Data, ANSI C12.20 Optional(3)Rapid Shutdown - NEC 2014 and 2017 690.12Automatic Rapid Shutdown upon AC Grid DisconnectSTANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI)EmissionsFCC Part 15 Class BINSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWGDC Input Conduit Size / # of Strings / AWG Range0D[LPXPᐎULQJV$:* 0D[LPXPᐎULQJV$:*Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185in / mmWeight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6OENJNoise < 25 <50 dBACoolingNatural ConvectionOperating Temperature Range -13 to +140 / -25 to +60(4) Ü)Ü&RSWLRQ (5)Ü)Ü&Protection Rating NEMA 4X (Inverter with Safety Switch)(1) For other regional settings please contact SolarEdge support (2)$KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVᐎDWHG (3) Revenue grade inverter P/N: SExxxxH-US000NNC2(4) For power de-rating information refer to: KWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI(5) -40 version P/N: SExxxxH-US000NNU4 SE3000H-USSE3800H-USSE5000H-USSE6000H-USSE7600H-USSE10000H-USSE11400H-USOUTPUTRated AC Power Output30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V76001000011400 @ 240V10000 @ 208VVAMaximum AC Power Output 30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V76001000011400 @ 240V10000 @ 208VVAAC Output Voltage Min.-Nom.-Max.(211 - 240 - 264)9999999VacAC Output Voltage Min.-Nom.-Max.(183 - 208 - 229)-9-9--9VacAC Frequency (Nominal)59.3 - 60 - 60.5(1)HzMaximum Continuous Output Current @240V12.5162125324247.5AMaximum Continuous Output Current @208V-16-24--48.5AGFDI Threshold1AUtility Monitoring, Islanding Protection,&RXQWU\&RQÀJXUDEOH7KUHVKROGVYesINPUTMaximum DC Power @240V4650590077509300118001550017650WMaximum DC Power @208V-5100-7750--15500WTransformer-less, Ungrounded YesMaximum Input Voltage480VdcNominal DC Input Voltage380400VdcMaximum Input Current @240V(2)8.510.513.516.5202730.5AdcMaximum Input Current @208V(2)-9-13.5--27AdcMax. Input Short Circuit Current45AdcReverse-Polarity ProtectionYesGround-Fault Isolation Detection600k Sensitivity0D[LPXP,QYHUWHU(੕FLHQF\9999.2%&(&:HLJKWHG(੕FLHQF\9999 @ 240V98.5 @ 208V%Nighttime Power Consumption< 2.5WADDITIONAL FEATURESSupported Communication InterfacesRS485, Ethernet, ZigBee (optional), Cellular (optional)Revenue Grade Data, ANSI C12.20Optional(3)Rapid Shutdown - NEC 2014 and2017 690.12Automatic Rapid Shutdown upon AC Grid DisconnectSTANDARD COMPLIANCESafetyUL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07Grid Connection StandardsIEEE1547, Rule 21, Rule 14 (HI)EmissionsFCC Part 15 Class BINSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range1" Maximum / 14-6 AWG1" Maximum /14-4 AWGDC Input Conduit Size / # of Strings / AWG Range0D[LPXPᐎULQJV$:*0D[LPXPᐎULQJV$:*Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 17421.3 x 14.6 x 7.3 / 540 x 370 x 185in / mmWeight with Safety Switch22 / 1025.1 / 11.426.2 / 11.938.8 / 17.6OENJNoise < 25<50dBACoolingNatural ConvectionOperating Temperature Range -13 to +140 / -25 to +60(4) Ü)Ü&RSWLRQ (5)Ü)Ü&Protection Rating NEMA 4X (Inverter with Safety Switch)(1) For other regional settings please contact SolarEdge support(2)$KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVᐎDWHG(3) Revenue grade inverter P/N: SExxxxH-US000NNC2(4) For power de-rating information refer to:KWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI(5) -40 version P/N: SExxxxH-US000NNU4Single Phase Inverterwith HD-Wave Technology for North America6(+866(+866(+866(+866(+866(+866(+86Œ6RODU(GJH7HFKQRORJLHV,QF$OOULJKWVUHVHUYHG62/$5('*(WKH6RODU(GJHORJR237,0,=('%<62/$5('*(DUHWUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI6RODU(GJH7HFKQRORJLHV,QF$OORWKHUWUDGHPDUNVPHQWLRQHGKHUHLQDUHWUDGHPDUNVRIWKHLUUHVSHFWLYHRZQHUV'DWH9(1*1$06XEMHFWWRFKDQJHZLWKRXWQRWLFH pe.eaton.com Eaton general duty cartridgefuse safety switchDG222NRBUPC:782113144221Dimensions:Height:14.37 IN●Length:7.35 IN●Width:8.4 IN●Weight:10 LBNotes:Maximum hp ratings apply only when dualelement fuses are used. 3-Phase hp rating shown isa grounded B phase rating, UL listed.Warranties: Eaton Selling Policy 25-000, one (1) year fromthe date of installation of the Product oreighteen (18) months from the date of shipmentof the Product, whichever occurs first.●Specifications:Type:General duty, cartridge fused●Amperage Rating:60A●Enclosure:NEMA 3R●Enclosure Material:Painted galvanized steel●Fuse Class Provision:Class H fuses●Fuse Configuration:Fusible with neutral●Number Of Poles:Two-pole●Number Of Wires:Three-wire●Product Category:General duty safety switch●Voltage Rating:240V●Supporting documents:Eatons Volume 2-Commercial Distribution●Eaton Specification Sheet - DG222NRB●Certifications: UL Listed●Product compliance:No Data______________________________________________________________________© 2016 Eaton. All rights reserved. 888-825-3432 | www.S-5.com | • 34% lighter - saves on shipping• Stronger L-Foot™ • Load-tested for engineered application• Corrosion-resistant materials• Adjustable - Fits rib profiles up to 3"• Peel-and-Stick prevents accidental shifting during installation• Fully pre-assembled• 25-year warranty*Features and BenefitsNOW AVAILABLE IN ALUMINUMThe right way to attach solar PV to trapezoidal roof profiles! ProteaBracket™ ™ProteaBracket™ A versatile bracket for mounting solar PV to trapezoidal roof profilesProteaBracket™ is now made in aluminum. Still the most versatile trapezoidal metal roof attachment solution on the market, the S-5! ProteaBracket just got better! The bracket features an adjustable attachment base and module attachment options to accommodate different roof profile dimensions and mounting options. Our pre-applied EPDM gasket with peel and stick adhesive makes installation a snap, ensuring accurate and secure placement the first time.With no messy sealants, faster installation, and a weather-proof fit, ProteaBracket offers you the most versatile solar attachment solution available. ProteaBracket* can be used for rail mounting or “direct-attach” with S-5! PVKIT™ *When ProteaBracket is used in conjunction with the S-5! PVKIT, an additional nut is required during installation.*See www.S-5.com for details.S-5!® Warning! Please use this product responsibly!Products are protected by multiple U.S. and foreign patents. For published data regarding holding strength, bolt torque, patents, and trademarks, visit the S-5! website at www.S-5.com.Copyright 2019, Metal Roof Innovations, Ltd. S-5! products are patent protected. S-5! aggressively protects its patents, trademarks, and copyrights. Version 07089.No surface preparation needed. (1) Wipe away excess oil and debris. (2) Peel off adhesive release paper. (3) Align and mount bracket directly onto crown of panel. (4) Secure ProteaBracket through pre-punched holes, using piercing-point S-5! screws.INSTALLATION: Distributed byProteaBracket™ is the perfect solar attachment solution for most trapezoidal rib, exposed-fastened metal roof profiles! ProteaBracket™ProteaBracket™ is compatible with common metal roofing materials and comes with a pre-applied EPDM gasket on the base.For design assistance, ask your distributor, or visit www.S-5.com for the independent lab test data that can be used for load-critical designs and applications. Also, please visit our website for more information including metallurgical compatibilities and specifications. Multiple Attachment Options:Side Mount RailBottom Mount Railw/ S-5! PVKIT™ (rail-less)S-5!® holding strength is unmatched in the industry.ProteaBracket™ and the S-5! PVKIT™ 2.0 mounted on a trapezoidal roof profileProteaBracket™ is still available in stainless steel.Note: All four pre-punched holes must be used to achieve tested strength. Fasteners are provided.ProteaBracket fits profiles up to 3 inches2.95"4.03" SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install, but best-in-class aesthetics make it the most attractive on any block!NOW FEATURING FLASHKIT PROThe Complete Roof Attachment SolutionNOW WITH UNIVERSAL MIDCLAMPSAccommodates 30mm-51mm module frames One tool, one-person installs are here!REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End CapsTHE PROFESSIONALS’ CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION EXPERIENCE • CURB APPEAL • COMPLETE SOLUTION • UNIRAC SUPPORT SOLARMOUNTOPTIONAL FRONT TRIMNew & Improved: THE PROFESSIONALS’ CHOICEWith Superior AestheticsCONCEALED UNIVERSAL CLAMPSW WITH UNIVERSAL MIDCLAMPIWITHTHUUNINEVESRSRSALALALMMIDICLCLAMP25 YEAR FULL-SYSTEM WARRANTYFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORTENGINEERINGEXCELLENCEUNMATCHEDEXPERIENCEPERMITDOCUMENTATIONDESIGNTOOLSCERTIFIEDQUALITYBANKABLEWARRANTYBETTER DESIGNS TRUST THE INDUSTRY’S BEST DESIGN TOOLStart the design process for every project in our U-Builder on-line design tool. It’s a great way to save time and money.BETTER SYSTEMSONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and dark finishes to optimize your design financials and aesthetics.BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOBTrust Unirac to help you minimize both system and labor costs from the time the job is quoted to the time your teams get off the roof. Faster installs. Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAMProfessional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we’ve got you covered. Visit Unirac.com/solarmount for more information.UNIVERSAL SELF STANDING MIDCLAMPSU-BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEYVisit design.unirac.comBANKABLE WARRANTYDon’t leave your project to chance, Unirac has the ƛQDQFLDOVWUHQJWKWREDFNRXUSURGXFWVDQGUHGXFH\RXUULVNHave peace of mind knowing you are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year OLPLWHGSURGXFWZDUUDQW\DQGD\HDUOLPLWHGƛQLVKZDUUDQW\TECHNICAL SUPPORTUnirac’s technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly VLPSOLƛHV\RXUSHUPLWWLQJDQGSURMHFWSODQQLQJSURFHVVCERTIFIED QUALITY PROVIDERUnirac is the only PV mounting vendor with ISO FHUWLƛFDWLRQVIRUDQG2+6$618001:2007, which means we deliver the highest standards IRUƛWIRUPDQGIXQFWLRQ7KHVHFHUWLƛFDWLRQVGHPRQVWUDWHRXUH[FHOOHQFHDQGFRPPLWPHQWWRƛUVWFODVVEXVLQHVVSUDFWLFHVUL2703BONDING & GROUNDINGMECHANICAL LOADINGSYSTEM FIRE CLASSIFICATIONLISTEDSOLARMOUNTCONCEALED UNIVERSAL ENDCLAMPSEND CAPS INCLUDED WITH EVERY ENDCLAMPENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAINFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702PUB2018AUG31 – PRINTED UPDATE DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 1 Certificate of Compliance Certificate: 70131735 Master Contract: 266909 Project: 80082031 Date Issued: 2021-06-02 Issued To: Unirac 1411 Broadway NE Albuquerque, New Mexico, 87102 United States Attention: Klaus Nicolaedis The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Michael Hoffnagle Michael Hoffnagle PRODUCTS CLASS - C531302 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems CLASS - C531382 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems -Certified to US Standards Models: SM - SOLARMOUNT Flush-to-Roof is an extruded aluminum rail PV racking system that is installed parallel to the roof in landscape or portrait orientations. ULA - Unirac Large Array is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. Solarmount Certificate: 70131735 Project: 80082031 Master Contract: 266909 Date Issued: 2021-06-02 DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 2 The system listed is designed to provide bonding/grounding, and mechanical stability for photovoltaic modules. The system is secured to the roof with the L-Foot components through the roofing material to building structure. Modules are secured to the racking system with stainless steel or aluminum mid clamps and Aluminum end clamps. The modules are bonded to the racking system with the stainless-steel bonding mid clamps with piercing points. The system is grounded with 10 AWG copper wire to bonding/grounding lugs. Fire ratings of Class A with Type 1, 2, 3, 10, 19, 22 or 25 for steep slope. Tested at 5” interstitial gap which allows installation at any stand-off height. The grounding of the system is intended to comply with the latest edition of the National Electrical Code, to include NEC 250 & 690. Local codes compliance is required, in addition to national codes. All grounding/bonding connections are to be torqued in accordance with the Installation Manual and the settings used during the certification testing for the current edition of the project report. The system may employ optimizers/micro-inverters and used for grounding when installed per installation instructions. UL 2703 Mechanical Load ratings: Downward Design Load (lb/ft²) 113.5 Upward Design Load (lb/ft²) 50.7 Down-Slope Load (lb/ft²) 16.13 Test Loads: Downward Load (lb/ft²) 170.20 Upward Load (lb/ft²) 76.07 Down-Slope Load (lb/ft²) 24.2 Unirac Large Array ULA is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. ULA aluminum components merge with SM rails and installer-supplied steel pipe. The SM rail system is secured to the horizontal Pipe using the Rail Bracket components. The Rear and Front cap secures the horizontal Pipe to the vertical Pipe. The Front cap is also used to secure the Cross brace. A Slider is attached to the vertical Pipe to secure the Cross brace. The SM rails, caps, slider, rail brackets, and cross braces materials are 6105-T5 aluminum extrusion. Fasteners materials are 304 stainless steel. Horizontal and vertical pipe materials meet the minimum requirements of ASTM A53 for galvanized steel pipe in 2” and 3” diameter. The mechanical load ratings from the SM test data will be applied to the ULA model. Fire Testing is not applicable due to being a ground mount system. APPENDIX HTechnicalData SheetsUnitsinplfin²SECTION MODULUS (X-AXIS)in³SECTION MODULUS (Y-AXIS)in³MOMENT OF INERTIA (X-AXIS) in4MOMENT OF INERTIA (Y-AXIS)in4RADIUS OF GYRATION (X-AXIS)inRADIUS OF GYRATION (Y-AXIS)in0.564 0.865 1.170.15 0.363 0.8980.067 0.113 0.2211.271CROSS SECTION AREA0.409 0.625 1.059BEAM HEIGHT1.70 2.57 3.00APPROX WEIGHT0.491 0.7280.254 0.269 0.5020.13 0.467 1.450.026 0.045 0.267PropertiesSOLARMOUNT LightSOLARMOUNT Rail Profile 2SOLARMOUNT HDPAGE H3TÜV Rheinland PTL, LLC, 1107 W. Fairmont Drive, Building A, Tempe, Arizona 85282, Tel (480) 966-1700, Fax (775) 314-6458 January 20, 2021 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87102 Attn.: Unirac - Engineering Department Re: Engineering Certification for the Unirac U-Builder 2.0 SOLARMOUNT Flush Rail PZSE, Inc. - Structural Engineers has reviewed the Unirac SOLARMOUNT rails, proprietary mounting system constructed from modular parts which is intended for rooftop installation of solar photovoltaic (PV) panels; and has reviewed the U-builder Online tool. This U-Builder software includes analysis for the SOLARMOUNT LIGHT rail, SOLARMOUNT STANDARD rail, and SOLARMOUNT HEAVY DUTY rail with Standard and Pro Series hardware. All information, data and analysis contained within are based on, and comply with the following codes and typical specifications: 1. 2020 Florida Building Code, by Florida Building Commission 2. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-16 3. 2018 International Building Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 4. 2018 International Residential Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 5. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES. 6. 2015 Aluminum Design Manual, by The Aluminum Association, 2015 Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 - 100 (psf) Basic Wind Speed = 85 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment Spacing: Per U-builder Engineering report. Cantilever: Maximum cantilever length is L/3, where “L” is the span noted in the U-Builder online tool. Clearance: 2” to 10” clear from top of roof to top of PV panel. Tolerance(s): 1.0” tolerance for any specified dimension in this report is allowed for installation. Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. Landscape - PV Panel long dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the short side. 1478 Stone Point Drive, Suite 190, Roseville, CA 95661T 916.961.3960 F 916.961.3965 W www.pzse.comExperience | Integrity | Empowerment Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE 7-16 Component and Cladding design. Notes: 1) U-builder Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems only and do not include roof capacity check. 2) Risk Category II per ASCE 7-16. 3) Topographic factor, kzt is 1.0. 4) Array Edge Factor ƳE = 1.5 5) Average parapet height is 0.0 ft. 6) Wind speeds are LRFD values. 7) Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U-Builder design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U-builder software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether the U-Builder Software is applicable to the project, and • Understand and determine the appropriate values for all input parameters of the U-Builder software. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush, when installed according to the U-Builder engineering report and the manufacture specifications, is in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. – Structural Engineers Roseville, CA 1478 Stone Point Drive, Suite 190, Roseville, CA 95661T 916.961.3960 F 916.961.3965 W www.pzse.comExperience | Integrity | EmpowermentEXP. 02/28/2023ZACHERPAULK.ENSECILARIDAOLFNOISSEFORP LENGINEERSTATE OFNo. 73522THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY PAULK. ZACHER, PE ON 01/20/2021 USING A SHA-1 AUTHENTICATION CODE.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNEDAND SEALED AND THE SHA-1 AUTHENTICATION CODE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.01/20/2021DIGITAL SIGNATURE