Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED Poly Tu Plus - Non HVHZ (1) (2)(1)
8/10/2021 Florida Building Code Online rtia.r.— `n „ U t Business & Professional Regulation in . t BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search E Innffa J"gProduct Approval dpr USER, Pubb, User Iy�ruv,J MCnu > Product or ApnhCatiOn Search > 6gR4cj tlnn Llst > Application Detall • FL # FL5259-R33 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email Jill W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1330 Ext242 malpert@polyglass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative TECH REP Address/Phone/Email Jill West Newport Center Drive Deerfield Beach, FL 33442 (866)802-8017 uspolyglasstechnical@polyglass.com Quality Assurance Representative QA REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888)410-1375 uspolyglasstechnical@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/23/2023 Validated By Sohn W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FI 5259 R33 CQI 2021 O1 COI NIEMINEN.pdf Referenced Standard and Year (of Standard) StandaYear ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM 06163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2015 https:/lfioridabuilding.orglprfpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2fegOlip[oQ53LIfLDSdir7nKfKN%a2bQ%3d%3d 1/2 8/10/2021 Florida Building Code Online Equivalence of Product Standards Certili By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FM 4474 2011 FRSA/TRI, Sixth Edition 2018 TAS 103 2020 UL 1897 2015 Method 1 Option D 04/07/2021 04/12/2021 04/14/2021 06/08/2021 FL # Model, Number or Name Description 5259.1 Polyglass Roof Underlayments Polyglass roof underlayments for use in FBC HVHZ jurisdictions. (HVHZ) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER Section 5 for Limits of Use. 5259.2 Polyglass Roof Underlayments non-HVHZ) () Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-622.5 Other: 1.) The design pressure in this application relates to one particular underlayment system for use in tile roof systems. Refer to ER Section 5.8.3 for other systems and associated maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. Installation Instructions FL5259 R33 11 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259- R33 (HVHZ),pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259- R33 (HVHZ)_pdf Created by Independent Third Party: Yes Polyglass roof underlayments, for use in FBC non-HVHZ jurisdictions. Installation Instructions FL5259 R33 1t 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL52S9- R33 (NON-HVHZ)lp[if Verified By: Robert Nleminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FLS259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259- R33 (NON-HVHZ),pdf Created by independent Third Party: Yes Contact Us :. 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. �Cc irk ht 2007-2013 state of Florida.:: Privacy Statement :: Accessibility, Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.2i5(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaels provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card Safe https:llfloridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2fegOliploQ53LIfLDSdir7nKfKN%2bQ%3d%3d 2/2 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 00 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT 7N RFPOF Polyglass USA, Inc. Evaluation Report P32060.02,09-1129 1111 West Newport Center Drive FL5259-R33 (NON-HVHZ) Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009 (954) 233-1330 Revision 29: 04/07/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 711 Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments, for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOI etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 18. Prepared by: '��y �� T3f�s�tia7 s= �A 31ta-f9T17~�te s CO =Y ' Robert J.M. Nieminen P.E. fi'••' �- �' Florida Registration No. 59I66, Florida C?CA ANE1983 •-'4`.�' , The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04107/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©20I9 NEMO ETC, LLC NNEMOJetc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 7t1 Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.3.1 Wind resistance UL 1897 2015 1507.1.1 / R905.1.1 Material standard ASTM D226 2009 1507.1.1, 1507.2.4, 1507,2.9.2 / Material standard ASTM D1970 2015 R905.1.1, R905.2.8.2 1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 1507.11.2 / R905.11.2 Material standard ASTM D6163 2015 1507.11.2 / R905.11.2 Material standard ASTM D6164 2011 1507.11.2 / R905.11.2 Material standard ASTM 06222 2011 1507.11.2 / 11905.11.2 Material standard ASTM D6509 2015 TAS 110 Accelerated Weathering ASTM D4798 2011 En ity Examination Reference Date Entity Examination Reference Date ERD (TST 6049) Wind Uplift 11757.04.01-1-RI 4/255/2001 ERD (TST 6049) FRSA/TRI (tile slippage) PLYG-SCI3040.12.16 12/27/2016 ERD (TST 6049) Wind Uplift 11757.08.01-1 8/13/20DI FRO (TST 6049) FRSA/TRI (tile slippagel PLYG-SC17115.08.17 8/8/2017 FRO (TST 6049) Wind Uplift 11776.06.02 1/16/2003 ERD (TST 60491 FRSA/TRI PLYG-SC13035.08.17 10/31/2017 ERD (TST 6049) Wind Uplift P1740.01.07 1/4/2o07 FM (TST 18671 Wind Uplift FM 3004091 1/12/2000 ERD (TST 6049) Wind Uplift P1738.02.07-R2 2/5/2007 NEMO (TST 6049) ASTM D1970 4-PLYG-18-004.03.18 3/29/2018 FRO (TST 6049) Wind Uplift P9260.03.68 3/21/2008 NEMO (TST 6049) ASTM 01623, TAS 103 454CP-18-001.07.18-R1 7/23/2018 ERD (TST 6049) Wind Uplift P30540.11.09-R1 11/23/2009 NEMO (TST 6049) Wind Uplift 4L-PLYG-18-003.01.19 1/11/2019 ERD (TST 6049) ASTM 01623, TAS 103 P11030.11.09.1 11/30/2009 NEMD (TST 6049) ASTM D6163 45-PLYG-18-DO2.01.19-A 1/24/2019 ERD (TST 6049) TAS 117(8), TAS 114(C) P11030.11.09-1 11/30/2009 NEMO (TST 6049) ASTM 06222 4S-PLYG-18-002.05.19-C 5/20/2019 FRO (TST 6049) ASTM D4977 PI1030.11.09-3 11/30/2009 NEMO (TST 6049) FRSA/TRI 45-PLYG-18-004.10.19-G 10/8/2019 ERD (TST 6049) ASTM D1970 P33360.06.10 6/Z5/I010 NEMO (TST 6049) FRSA/TRI 45-PLYG-18.004,10.19-1 10/8/2019 ERD (TST 6049) FRSA/TRI P33370.03.11 3/2/20I1 NEMO (TST 6049) FRSA/TRI 45-PLYG-18-004.10.19-L 10/9/2019 ERD (TST 6049) ASTM D1623. TAS 103 P33370.04.11 4/26/2D11 NEMO (TST 6049) FR5A/TRI 4S-PLYG-18-004.12.19-F 12/18/2019 FRO (TST 6049) ASTM D1970, D4798 P37300.10.11 10/1912011 NEMO (TST 6049) FRSA/TRI 4j-PLYG-19-55UDL-02.A 1/2/2020 ERD (TST 6049) FR5A/TRI P40390.08.12-1 8/6/2012 NEMO (TST 6049) ASTM D6222 45-PLYG-18-002.12.19-K-141 1/7/2020 ERD (TST 6049) ASTM D1623, TAS 103 P40390.08.12-2 8/7/2012 NEMO (TST 6049) ASTM D1970, D4798 45-PLYG-18-004.0120.1-11 1/14/Z020 ERD (TST 6049) ASTM D1623, TA5 103 C41420.09.12-3 9/11/2012 NEMD (TST 6049) ASTM 131970, D4798 45-PLYG-18-004.01.20A 1/14/2020 ERD {TST 6049) ASTM D6509 P37590.03.13-1-R1 Z/5/2013 NEMD (TST 6049) FRSA/TRI (tile slippage) 4S-PLYG-18-004.D1.20.A 1/16/2020 ERD (TST 6049) TAS 114(l) P39680.03.13 3/4/2013 NEMO (TST 6049) ASTM D6164 4S-PLYG-18-004.01.20.8 1/16/2020 ERD {TST 6049) ASTM D6164 P37590.03.13-3A 3/6/2013 NENIO (TST 6049) FRSA/TRI PLYG-SC15855.05.20.A 5/29/2020 ERD ITST 6049) ASTM D6164 P37590.07.13-1 7/2/2013 NEMO (TST 6049) FRSA/TRI 4J-PLYG-20-55UDL-01 7/6/2020 ERD (T5T 6049) Wind Uplift P41630.08.13 8/6/2013 MEMO (TST 6049) ASTM D6222 4q-PLYG-19.55MB6-05.A 7/23/2020 ERD (TST 6049) ASTM D4601 P45940.09.13 9/4/2013 NEMO {TST 60491 ASTM D4798, D1623 41-PLYG-I9-SSUDL-05.A 9/10/2020 ERD ITST 6049) ASTM D4601 P45940.09.13 9/4/1013 NEMD {T5T 6049) ASTM D1970 4i-PLYG-20-5SUDL-05.A 9/30/2020 ERD (TST 6049) ASTM 01970 (adhesion) P45370.09A3 9/19/2013 NEMO (TST 60491 FRSA/TRI 4j-PLYG-20-SSUD1_-05.0 9/30/2020 FRO (TST 60491 Wind Uplift P11751.05.03-R3 11/26/2013 NEMO (TST 6049) FRSA/TRI 4i-PLYG-20-S5UDL-11.A 10/21/2020 FRO (TST 60491 Wind Uplift P11781.11M.111 11/26/2013 NEMO (TST 60491 ASTM 01970, D4798 45-PLYG•18-004.12.19.D 1012712020 ERD (TST 604% ASTM D1623, TAS 103 P45270.05.14 5/12/2014 NEMO (TST 6049) FRSA/TRI 4j-PLYG.19-55UDL-01.A 11/18/2020 ERD (TST 6049) ASTM D1623, TAS 103 6020.09,14-5 9/g/2014 NEMO (TST 6D49) ASTM D3623, TAS 103 4p-lCP-20-5SLAP-01.A 12/15/2020 ERD (TST 6D49) ASTM D1623, TAS 103 6020.09.14-6 9/8/2014 NFMO (TST 6049) ASTM 04798, 01623 4j-PLYG-20-SSUDlA1A 03/02/2021 ERD (TST 6049) ASTM D1623 P46520.10.14 10/3/2014 NEMO (TST 6049) ASTM D1623, TAS 103 4p-ICP-20-55UDL-03.A 03/04/2021 FRO (TST 6049) FRSA/TRI P44360.10.14-RI 10/7/2014 NEMO (TST 6049) ASTM D1623, TAS 103 41-PLYG-20-55UDL-07.A 04/07/2021 NEMO ETC, LLC. Evaluation Report P12000.02.09-R29 Certificate of Authorization #32455 71m EDITION (2020) FSC NON-HVHZ EVALUATION FL$259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 2 of 18 Entity Examination Reference Date knOy Examination ERD (TST 60491 A5TM 01970, 04798 P43290.10.14 10/17/2014 Polyglass USA P/L Affidavit ERD (TST 6049} FRSA/TRi PLYG-SC7550.03.15 3/24/2015 Polyglass USA Materials Affidavit ERD (TST 604% ASTM D1623 P40390.04.15 4/3/2015 Polyglass USA Materials Affidavit ERD (TST 6049) Wind Up4ft PLYG-SC6905.05.16-1 5/17/2016 PRI(TST5876) UL1897 ERD (TST 6049) ASTM D1970, 04798 PLYG-SC10130.06.I6-1 6/27/2016 PRI (TST5879) UL1897 ERD(TST 60491 ASTM D1623,TAS103 PLYG-SC10130.06.16-2 6/27/2016 PRI(TST5878) UL1891 ERD (TST 6049i FRSA/TRi PLYG-SCI0130.06.16.3 6/27/2016 UL (QUA96251 Quality Control ERD (TST 6049) ASTM D1970, D4798 PLYG-SC8080.07.16 7/16/2016 UL (QUA9625) Quality Control ERD (TST 6D49) UL1897 PLYG-SC12025.10.16 10/12/2016 UL (QUA9625) Quality Control MEMO I etc Reference Date Mule -Hide Cross Ltg 03/01/2008 Pnlystick Compound 08/18/2011 Pnlystick Compound 01/13/2021 70ST0058-1 01/13/2021 70ST0058-6 02/17/2C21 708T0058.7 02/25/2021 Service Confirmation (FL) 09/13/2018 Service Confirmation (TX) 11/07/2019 Florida B05 Current Product Material Standard Plant(s) Description Elastobase ASTM D6163 FL Fiberglass -reinforced, SBS modified bitumen base sheet Elastobase P ASTM D6164 FL Polyester -reinforced, SBS modified bitumen base sheet Elastoflex S6 G ASTM D6164 FL, PA Polyester -reinforced, SBS modified bitumen cap sheet FRSA/TRI 09-18 Elastoflex S6 G FR ASTM D6164 FL Polyester -reinforced, SB5 modified bitumen cap sheet FRSA/TRI 09-18 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt FRSA/TRI 09-18 waterproofing membrane, fiberglass reinforced, with a polyester fabric surface Muie-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet FRSA/TR109-18 Mule -Hide SA -ARP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet (FR) FRSA/TRI 09-18 Polyflex G ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for FRSA/TRI 09-18 use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition beneath mechanically fastened or adhered tile roof systems Polyflex G FR ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for FRSA/TRI 09-18 use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition beneath mechanically fastened tile roof systems Polyflex SA P ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI 09-18 Polyflex SA P FR ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI09-18 Polyglass Base ASTM D6509 FL Fiberglass -reinforced, APP modified bitumen base sheet Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass -reinforced, asphaltic base sheet 1. PRODUCT 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 NEW ETC, I.I.C. Evaluation Report P12060.02,09-R29 Certificate of Authorlration#32455 7"' EDITION (2020) F8C NON-HVH7 EVALUATION FL5259-1133 (NON-HVHZ) Polyglass Roof Underlaynnents Revision 29: 04/07/2021 Page 3 of 18 M 4.15 4.16 4.17 4.18 4.19 4.20 4.21 ONEMOletc. .D Product Material Standard Plant(s) Description Polystick IR-Xe ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface Polystick MTS Plus ASTM D1970 FL, NV, Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 PA, TX membrane, glass fiber reinforced, surfaced with polyolefinic film surface Polystick MU-X ASTM D19701 FL, NV, PA Nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface Polystick TU Max ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane with a 190 g/ml polyester fabric surface Polystick TU P FRSA/TRI 09-18 FL, PA, TX Nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface Polystick TU Plus ASTM D1970 FL, PA, TX Nominal 80-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane, glass fiber reinforced, with a polyester fabric surface Polystick XFR ASTM D1970 NV, TX Nominal 80-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane, glass fiber reinforced, surfaced with a textured film surface S. LimITATIONS: 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Referto FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. if not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. Polystick MU-X has been found through comparative testing to hove a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should he established as to slip resistance. NEMO ETC, LLC. Evaluation Report P1.2060.02.09-R29 Certificate of Authorization #32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 4 of 1S NNEMOletC. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FBC Section: 1507.2 1S07.3 1507.4 and 1507.5 1507.7 1S0L8 and 1507,9 Asphalt Clay and Concrete Tile Slate or Slate- Underlayment Shingles Mechanical Attach Adhesive -Set Metal Type Shingles Wood Yes Yes Yes Yes Yes Yes Elastobase (Alternate to (as Base Sheet, (as Base Sheet, (Alternate to (Alternate to (Alternate to D226, Type III See 5.8.3) See 5.8.3) 13226, Type II) 13226, Type Ili D226, Type II) Yes Yes Yes Yes Yes Yes Elastobase P (Alternate to (as Base Sheet, (as Base Sheet, (Alternate to (Alternate to (Alternate to D226, Type II) See 5.8.3) See 5.8.3) D226, Type Ili 0226, Type II) D226, Type II) Yes Yes Polyglass Base No (as Base Sheet, (as Base Sheet, No No No See 5.8.31 See 5.8.31 Yes Yes Polyglass G2 Base No (as Base Sheet, (as Base Sheet, No No No See 5.8.3) See 5A3) Elastoflex 56 G No Yes Yes No No No (See 5.6.1) Elastoflex 56 G FIR No Yes No No No No Yes HydraGuard Dual Pro Yes No No Yes Yes Ooint strips, 1507.1.1.3 / R905.1.1.3] Yes HydraGuard Tile Pro Yes Yes (See Yes Yes Yes (joint strips, 1507.1.1.3 5./ R9053.1.3j Mule -Hide SA-APP Cap Sheet No Yes Yes No No No (See 5.6.1) Mule -Hide SA-APP Cap Sheet (FR) No Yes Yes No No No;see 5.6.1) Polyflex G No Yes Yes No No No (See 5.6.1) Polyflex G FR No Yes No No No No Polyflex SA P No Yes Yes No No No (See 5.6.1) Polyflex 5A P FIR No Yes Yes No No No (See 5.6.11 Yes Polystick IR-Xe Yes No No No Yes Uolntstrips, 1507.1.1.3 / R905.1.1-3) Yes Polystick MTS Plus Yes Yes No Yes Yes (joint strips, 1507.1.1.3 / R905.1.1.31 Yes Polystick MU-X Yes No No Yes Yes gointstrips, 1507.1.1.3 / R905.1.1.3) Yes Polystick TU Max No Yes (seYes Yes No 6ointsirips, 1507.1.1.3 / R905.1.1.31 Yes Polystick TU P No Yes Yes No No (joint strips,1507.1.1.3 Y (See 5.6.1) / 11905.1.1.3) Yes Polystick TU Plus Yes Yes {seYe 6.1) Yes Yes (joint strips,1507.1a.3 / R905.1.1.3) Yes Polystick XFR Yes Yes No Yes Yes (Joint strips, 1507.1.1.3 / R905.1.1.3) NEMO ETC, U.C. Evaluation Report P32060.02.09-11129 Certificate of Authorization #32455 7r" EDITION (2020) FBC NON•HVHZ EVALUATION FL5259-R33 (NON-HVHZ} Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 5 of 18 ONEMOjetc. 5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations. TABLE 1A: ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS Underlayment Adhesive Florida Product Approval Polystick TU Max, Polystick TU P or Polystick TU Plus DAP Foam "Touch 'n Seal StarmBond Roof Tile Adhesive" FL14506 Polystick TU P DAP Foam "Touch 'n Seal FL21374 StormBond 2 Roof Tile Adhesive" HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick Dupont "Tile Bond— Roof Tile FL22525 TU Plus Adhesive" Elastoflex 56 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA- ICP Adhesives and Sealants APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, "Polyset® AH-160" FL6332 Polystick TU P or Polystick TU Plus Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA- ICP Adhesives and Sealants APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, "Polyset' RTA-1" FL6276 Polystick TU P or Polystick TU Plus 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Material(s) HydraGuard Dual Pro, (Optional) ASTM plywood, OSB, Southern Yellow Pine or Huber Engineered HydraGuard Tile Pro, Polystick IR- Deck 1 D41 Woods "ZIP System" Panels Xe, Polystick MTS Pius, Polystick sheathing ASTM D41 structural concrete MU-X, Polystick TU Max, self- ASTM C1289 Type II Class 1 polyisocyan u rate, ASTM Polystick TU P, Polystick TU Plus, adhering Insulation (Optional) ASTM C1289 Type V polyisocyanurate-composite, DensDeck Polystick XFR, Mule -Hide SA-APP D41 or WB-3004 Prime or SECUROCK Gypsum -Fiber Roof Board Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P or Base Sheet N/A ASTM D226, Type II felt, Elastobase, Elastobase P or Mule - Polyflex SA P FR Hide Nail Base Deck ASTM D41 structural concrete Insulation (Optional) ASTM DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board Elastoflex S6 G or Elastoflex S6 G hat asphalt Q41 FR ASTM Q226, Type II felt, Elastobase, Elastobase P, Mule - Base Sheet N/A Hide Nail Base or Polyglass G2 Base Deck ASTM D41 structural concrete Insulation (Optional) ASTM DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board torch- Polyflex G or Polyflex G FR applied D41 Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass Base Sheet NIA G2 Base or Polyglass Base I Refer to Tile Manufocturet's at Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, U.C. Evaluation Report P12D60.02.09-R29 certificate ofAuthorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 6 of 18 4" IkTNEMO I etc. 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached base sheets - not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition, Appendix A, Table 1 (for Two - Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure = -52.5 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all OSB joints Base Ply: Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #2 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #3 Maximum Design Pressure = -97.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x lY." ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure = -105 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-RI9 Certificate of Authorization #32455 7TM' EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 7 of 19 ONEW10letc. #5 Maximum Design Pressure = -135 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Joints: Min, 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #6 Maximum Design Pressure = -165 psf: Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09, 15/32 Category to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x I%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.. #7 Maximum Design Pressure = -202.5 psf: Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09, 15/32 Category to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 at 0.5 gal/square Base Ply: Polystick MTS Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1X" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.. #8 Maximum Design Pressure = -255 psf: Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09, 15/32 Category to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 at 0.5 gal/square. Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.. #9 Maximum Design Pressure = -315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self adhered. #10 Maximum Design Pressure = -622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #11 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of -45 psf. 5.9.3.2 Mechanically -Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 Or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. NEMO ETC, LLC. Evaluation Report P12060.02.09-R29 Certificate of Authorization #31455 71" EDITION (20201 FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 8 of 18 ONEMOletc. #12 Maximum Design Pressure = -30.0 psf*: Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #13 Maximum Design Pressure = -37.5 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly-fiim top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o,c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #14 Maximum Design Pressure = -37.5 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #15 Maximum Design Pressure = -45 sf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: One (1) layer ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #16 Maximum Design Pressure = -45 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c, at the 2-inch wide side laps and 9-inch o.c, at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt. #17 Maximum Design Pressure = -45 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #18 Maximum Design Pressure = -45.D psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathingto meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. NEMO ETC, LLC. Evaluation Report P12060.02.09-R29 Certificate ofAutharizotion #32455 7"' EDITION (2020) FOC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 9 of 18 NNEMOJetc. #18 Maximum Design Pressure = -45.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/9" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #20 Maximum Design Pressure = -45.0 psf: Deck: APA rated, 7/16 CAT, 0.419 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c, at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #21 Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #22 Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FIR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #23 Maximum Desien Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #24 Maximum Design Pressure = -60 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: 11 ga. x 1.25-inch long x 3/S-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #25 Maximum Design Pressure = -60 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. NEMO ETC, LLC, Evaluation Report P12060.02.09-R29 Cerrifkare of Aurhorizotion #32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 10 of 18 NNEM01 etc. #26 Maximum Design Pressure =-60.0�sf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P or Polystick TU Plus, self -adhered. #27 Maximum Design Pressure = -60.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #28 Maximum Design Pressure = -60.0 psf: Deck: APA rated, 7/1.6 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #29 Maximum Design Pressure = -67.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch-opplied underiayment) Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #30 Maximum Design Pressure = -67.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180" into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c, at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Primer: (Optional) PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P or Polystick TU Plus, self -adhered. #31 Maximum Design Pressure = -67.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. NENIO ETC, I.LC, Evaluation Report P12060.02.09-R29 Certificateof Authorization#32455 71" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 {NON-HVHZI Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 11 of 18 4" IT NEMO I etc. #32 Maximum Design Pressure = -67.5 sf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width direction of the sheet - Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #33 Maximum Design Pressure = -75 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied Underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, 01MG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #34 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #35 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with CMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c, at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex Sfi G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #36 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c, at three (3) equally spaced staggered center rows. Underlayment: Elastoflex Sfi G, applied in full mopping of hot asphalt. #37 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. 438 Maximum Design Pressure = -90.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. NENIO ETC, I.I.C. Evaluation Report P12060.02.09-R29 Certificate of Authorization #32455 7"' EDITION (2020) FBC NON-HVHZ EVALUATION FL5259•R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 22 of 18 NNEM01eft. #39 Maximum Design Pressure = -90.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #40 Maximum Design Pressure = -90.0 psf: Deck: APA rated, 7/16 CAT, 0,418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #41 Maximum Design Pressure = -97.5 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 44rich wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P or Polystick TU Plus, self -adhered. #42 Maximum Design Pressure = -97.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c, at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #43 Maximum Design Pressure = -97.5 psf: Deck: APA rated, 19/32 CAT, 0,578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #44 Maximum Design Pressure = -97.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #45 Maximum Design Pressure = -105 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. NEMO ETC, LLC. Evaluation Report P12060.02.09-1129 Certificate of Authorization A32455 7t" EDITION 120ZO) FBC NON-HVHZ EVALUATION FL5259-R33 INON-HVHZI Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 13 of 18 ONEMOletc. 446 Maximum Design Pressure = -105.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #47 Maximum Design Pressure = -105.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #48 Maximum Design Pressure = -105.0 psf: Deck; APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #49 Maximum Design Pressure = -112.5 psf; Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga, x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin taps Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin -caps Base Ply: Polystick MTS Plus, self -adhered Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex 5A P FR, PolystickTU Max, Polystick TU P or Polystick TU Plus, self -adhered. #50 Maximum Design Pressure = -120 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or CMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. 451 Maximum Design Pressure = -120 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. NEMO ETC, LLC. Evaluation Report P12060.02.09-R29 certificate afAuthorization #32455 71" EDITION (20201 FBC NON•HVH7 EVALUATION FL5259•R33 (NON-HVH2) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 14 of 18 ONEMOletc. #52 Maximum Design Pressure = -127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide 5A-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #53 Maximum Design Pressure = -127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, 056 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt. #54 Maximum Design Pressure = -127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Installation Type Maximum Exposure (days) Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base Mechanically attached 30 Polystick IR-Xe or Polystick MU-X Mechanically attached 90 HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR Any type (per Table 1) ISO Elastoflex 56 G, Elastoflex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR Adhesive -set tile roof system ISO Mechanically attached UNLIMITED NEMO ETC, LLC. Evaluation Report P12060.02.09-RZ9 Cerrificare of Authorization x32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 15 of 18 ONEMOJetc. 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Staging Slope Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) Prohibited without battens HydraGuard Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS Plus Flat 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat or Lugged 6-tile stack (4 over 2) 7:12 Polystick TU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polystick XFR Flat or Lugged Prohibited without battens Prohibited without battens 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase, Elastobase P or Mule -Hide Nail Base: 6.31 Non -Tile Applications: Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Applications: 6.3.2.1 Elastobase (poly -film top), Elastobase P (poly -film top) and Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the 'TWO-PLY SYSTEM" from FRSA/TRI Florida Nigh Wind Concrete and Cloy Roof Tile Installotion Manual, Sixth Edition, followed by Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered or Polyflex G or Polyflex G FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for attachment requirements. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R29 Certificate OfAuthorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-1133 (NON-HVHZ) Polyglass Roof Underlayments Revision 29. 04/07/2021 Page 16 of 28 OMEMO I etc. 6.3.2.2 Elastobase (sanded -top) and Elastobase P (sanded-top)e are limited to use as a mechanically attached base sheet in the "TWO- PLY SYSTEM" from FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition, followed by Elastoflex S6 G, Elastoflex 56 G FR or an FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), asphalt -applied or Polyflex G or Polyflex G FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. • When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by asphalt -applied Elastoflex S6 G, Elastoflex S6 G FR or FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1 or Section 5.8.3.2 herein for attachment requirements. • When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by torch -applied Polyflex G or Polyflex G FR, refer to Section 5.8.3.2 herein for attachment requirements. 6.4 6,4.1 6.4.2 6.4.3 HydraGuard Dual Pro, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick IR-Xe, Polystick MTS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR: General: All seal -lap seams (selvage laps) must be firmly rolled with a in accordance with Polyglass requirements to ensure full contact and adhesion. For HydraGuard Dual Pro and HydraGuard Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of Overlap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro Non -Tile Applications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt, Elastobase, Elastobase P or Mule -Hide Nail Base, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. Tile Applications excludes HydraGuard Dual Pro Polystick IR-Xe and Polli,stick MU-X : Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 6.4.4 Multi -Ply Underlayment Systems: Polystick MTS Plus or Polystick XFR followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R29 Certificate oJAuthorization #32455 7m EDITION (2020) FBC NON-HVHZ EVALUATION F15259-1133 {NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 17 of 19 NNEMO I etc. 6.5 Elastoflex S6 G or Elastoflex S6 G FR: 6.5.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8.2 and 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 6.6 Polyflex G or Po"ex G FR: 6.6.1 Shall be installed in compliance with requirements as an alternate to the "Heat Applied Cap Sheet" in the "Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 18. MANUFAcTuRING PLANTS: Contact the named CiA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. QUALITY19. UL LLC — QUA9625; (414) 248-6409; Karen.buchmann@ul.com - END OF EVALUATION REPORT - NEMO ETC, I.I.C. Evaluation Report P12060.02.09-11129 Certificate ofAuthorixation #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZi Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 18 of 18