• FL #
FL5259-R33
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email Jill W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1330 Ext242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative TECH REP
Address/Phone/Email Jill West Newport Center Drive
Deerfield Beach, FL 33442
(866)802-8017
uspolyglasstechnical@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/23/2023
Validated By Sohn W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FI 5259 R33 CQI 2021 O1 COI NIEMINEN.pdf
Referenced Standard and Year (of Standard) StandaYear
ASTM D1970 2015
ASTM D226 2009
ASTM D4798 2011
ASTM 06163 2015
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2015
https:/lfioridabuilding.orglprfpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2fegOlip[oQ53LIfLDSdir7nKfKN%a2bQ%3d%3d 1/2
8/10/2021
Florida Building Code Online
Equivalence of Product Standards
Certili By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
FM 4474
2011
FRSA/TRI, Sixth Edition
2018
TAS 103
2020
UL 1897
2015
Method 1 Option D
04/07/2021
04/12/2021
04/14/2021
06/08/2021
FL # Model, Number or Name Description
5259.1 Polyglass Roof Underlayments Polyglass roof underlayments for use in FBC HVHZ jurisdictions.
(HVHZ)
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER Section 5 for Limits of Use.
5259.2 Polyglass Roof Underlayments
non-HVHZ) ()
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-622.5
Other: 1.) The design pressure in this application
relates to one particular underlayment system for
use in tile roof systems. Refer to ER Section 5.8.3
for other systems and associated maximum design
pressures. 2.) Refer to ER Section 5 for other limits
of use.
Installation Instructions
FL5259 R33 11 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 (HVHZ),pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 (HVHZ)_pdf
Created by Independent Third Party: Yes
Polyglass roof underlayments, for use in FBC non-HVHZ jurisdictions.
Installation Instructions
FL5259 R33 1t 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL52S9-
R33 (NON-HVHZ)lp[if
Verified By: Robert Nleminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FLS259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 (NON-HVHZ),pdf
Created by independent Third Party: Yes
Contact Us :. 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. �Cc irk ht 2007-2013 state of Florida.:: Privacy Statement :: Accessibility, Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.2i5(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaels
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Credit Card
Safe
https:llfloridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2fegOliploQ53LIfLDSdir7nKfKN%2bQ%3d%3d 2/2
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
00 Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
7N RFPOF
Polyglass USA, Inc. Evaluation Report P32060.02,09-1129
1111 West Newport Center Drive FL5259-R33 (NON-HVHZ)
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954) 233-1330 Revision 29: 04/07/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 711 Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments, for use in FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and
FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our
Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the
Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative
to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOI etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 18.
Prepared by:
'��y
��
T3f�s�tia7
s= �A 31ta-f9T17~�te s
CO =Y
'
Robert J.M. Nieminen P.E.
fi'••' �- �'
Florida Registration No. 59I66, Florida C?CA ANE1983
•-'4`.�' , The facsimile seal appearing was authorized by Robert Nieminen, P.E. on
04107/2021. This does not serve as an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
©20I9 NEMO ETC, LLC
NNEMOJetc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 7t1 Edition (2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
Section
Property
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2015
1507.1.1 / R905.1.1
Material standard
ASTM D226
2009
1507.1.1,
1507.2.4, 1507,2.9.2 /
Material standard
ASTM D1970
2015
R905.1.1,
R905.2.8.2
1507.3.3 / R905.3.3
Material standard
FRSA/TRI,
Sixth Edition
2018
1507.11.2 / R905.11.2
Material standard
ASTM D6163
2015
1507.11.2 / R905.11.2
Material standard
ASTM D6164
2011
1507.11.2 / R905.11.2
Material standard
ASTM 06222
2011
1507.11.2 / 11905.11.2
Material standard
ASTM D6509
2015
TAS 110
Accelerated Weathering
ASTM D4798
2011
En ity
Examination
Reference Date
Entity
Examination
Reference
Date
ERD (TST 6049)
Wind Uplift
11757.04.01-1-RI 4/255/2001
ERD (TST 6049)
FRSA/TRI (tile slippage)
PLYG-SCI3040.12.16
12/27/2016
ERD (TST 6049)
Wind Uplift
11757.08.01-1 8/13/20DI
FRO (TST 6049)
FRSA/TRI (tile slippagel
PLYG-SC17115.08.17
8/8/2017
FRO (TST 6049)
Wind Uplift
11776.06.02 1/16/2003
ERD (TST 60491
FRSA/TRI
PLYG-SC13035.08.17
10/31/2017
ERD (TST 6049)
Wind Uplift
P1740.01.07 1/4/2o07
FM (TST 18671
Wind Uplift
FM 3004091
1/12/2000
ERD (TST 6049)
Wind Uplift
P1738.02.07-R2 2/5/2007
NEMO (TST 6049)
ASTM D1970
4-PLYG-18-004.03.18
3/29/2018
FRO (TST 6049)
Wind Uplift
P9260.03.68 3/21/2008
NEMO (TST 6049)
ASTM 01623, TAS 103
454CP-18-001.07.18-R1
7/23/2018
ERD (TST 6049)
Wind Uplift
P30540.11.09-R1 11/23/2009
NEMO (TST 6049)
Wind Uplift
4L-PLYG-18-003.01.19
1/11/2019
ERD (TST 6049)
ASTM 01623, TAS 103
P11030.11.09.1 11/30/2009
NEMD (TST 6049)
ASTM D6163
45-PLYG-18-DO2.01.19-A
1/24/2019
ERD (TST 6049)
TAS 117(8), TAS 114(C)
P11030.11.09-1 11/30/2009
NEMO (TST 6049)
ASTM 06222
4S-PLYG-18-002.05.19-C
5/20/2019
FRO (TST 6049)
ASTM D4977
PI1030.11.09-3 11/30/2009
NEMO (TST 6049)
FRSA/TRI
45-PLYG-18-004.10.19-G
10/8/2019
ERD (TST 6049)
ASTM D1970
P33360.06.10 6/Z5/I010
NEMO (TST 6049)
FRSA/TRI
45-PLYG-18.004,10.19-1
10/8/2019
ERD (TST 6049)
FRSA/TRI
P33370.03.11 3/2/20I1
NEMO (TST 6049)
FRSA/TRI
45-PLYG-18-004.10.19-L
10/9/2019
ERD (TST 6049)
ASTM D1623. TAS 103
P33370.04.11 4/26/2D11
NEMO (TST 6049)
FR5A/TRI
4S-PLYG-18-004.12.19-F
12/18/2019
FRO (TST 6049)
ASTM D1970, D4798
P37300.10.11 10/1912011
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-19-55UDL-02.A
1/2/2020
ERD (TST 6049)
FR5A/TRI
P40390.08.12-1 8/6/2012
NEMO (TST 6049)
ASTM D6222
45-PLYG-18-002.12.19-K-141
1/7/2020
ERD (TST 6049)
ASTM D1623, TAS 103
P40390.08.12-2 8/7/2012
NEMO (TST 6049)
ASTM D1970, D4798
45-PLYG-18-004.0120.1-11
1/14/Z020
ERD (TST 6049)
ASTM D1623, TA5 103
C41420.09.12-3 9/11/2012
NEMD (TST 6049)
ASTM 131970, D4798
45-PLYG-18-004.01.20A
1/14/2020
ERD {TST 6049)
ASTM D6509
P37590.03.13-1-R1 Z/5/2013
NEMD (TST 6049)
FRSA/TRI (tile slippage)
4S-PLYG-18-004.D1.20.A
1/16/2020
ERD (TST 6049)
TAS 114(l)
P39680.03.13 3/4/2013
NEMO (TST 6049)
ASTM D6164
4S-PLYG-18-004.01.20.8
1/16/2020
ERD {TST 6049)
ASTM D6164
P37590.03.13-3A 3/6/2013
NENIO (TST 6049)
FRSA/TRI
PLYG-SC15855.05.20.A
5/29/2020
ERD ITST 6049)
ASTM D6164
P37590.07.13-1 7/2/2013
NEMO (TST 6049)
FRSA/TRI
4J-PLYG-20-55UDL-01
7/6/2020
ERD (T5T 6049)
Wind Uplift
P41630.08.13 8/6/2013
MEMO (TST 6049)
ASTM D6222
4q-PLYG-19.55MB6-05.A
7/23/2020
ERD (TST 6049)
ASTM D4601
P45940.09.13 9/4/2013
NEMO {TST 60491
ASTM D4798, D1623
41-PLYG-I9-SSUDL-05.A
9/10/2020
ERD ITST 6049)
ASTM D4601
P45940.09.13 9/4/1013
NEMD {T5T 6049)
ASTM D1970
4i-PLYG-20-5SUDL-05.A
9/30/2020
ERD (TST 6049)
ASTM 01970 (adhesion)
P45370.09A3 9/19/2013
NEMO (TST 60491
FRSA/TRI
4j-PLYG-20-SSUD1_-05.0
9/30/2020
FRO (TST 60491
Wind Uplift
P11751.05.03-R3 11/26/2013
NEMO (TST 6049)
FRSA/TRI
4i-PLYG-20-S5UDL-11.A
10/21/2020
FRO (TST 60491
Wind Uplift
P11781.11M.111 11/26/2013
NEMO (TST 60491
ASTM 01970, D4798
45-PLYG•18-004.12.19.D
1012712020
ERD (TST 604%
ASTM D1623, TAS 103
P45270.05.14 5/12/2014
NEMO (TST 6049)
FRSA/TRI
4j-PLYG.19-55UDL-01.A
11/18/2020
ERD (TST 6049)
ASTM D1623, TAS 103
6020.09,14-5 9/g/2014
NEMO (TST 6D49)
ASTM D3623, TAS 103
4p-lCP-20-5SLAP-01.A
12/15/2020
ERD (TST 6D49)
ASTM D1623, TAS 103
6020.09.14-6 9/8/2014
NFMO (TST 6049)
ASTM 04798, 01623
4j-PLYG-20-SSUDlA1A
03/02/2021
ERD (TST 6049)
ASTM D1623
P46520.10.14 10/3/2014
NEMO (TST 6049)
ASTM D1623, TAS 103
4p-ICP-20-55UDL-03.A
03/04/2021
FRO (TST 6049)
FRSA/TRI
P44360.10.14-RI 10/7/2014
NEMO (TST 6049)
ASTM D1623, TAS 103
41-PLYG-20-55UDL-07.A
04/07/2021
NEMO ETC, LLC.
Evaluation Report P12000.02.09-R29
Certificate of Authorization #32455
71m EDITION (2020) FSC NON-HVHZ EVALUATION
FL$259-R33
(NON-HVHZ)
Polyglass Roof Underlayments
Revision 29:
04/07/2021
Page 2 of 18
Entity
Examination
Reference
Date
knOy
Examination
ERD (TST 60491
A5TM 01970, 04798
P43290.10.14
10/17/2014
Polyglass USA
P/L Affidavit
ERD (TST 6049}
FRSA/TRi
PLYG-SC7550.03.15
3/24/2015
Polyglass USA
Materials Affidavit
ERD (TST 604%
ASTM D1623
P40390.04.15
4/3/2015
Polyglass USA
Materials Affidavit
ERD (TST 6049)
Wind Up4ft
PLYG-SC6905.05.16-1
5/17/2016
PRI(TST5876)
UL1897
ERD (TST 6049)
ASTM D1970, 04798
PLYG-SC10130.06.I6-1
6/27/2016
PRI (TST5879)
UL1897
ERD(TST 60491
ASTM D1623,TAS103
PLYG-SC10130.06.16-2
6/27/2016
PRI(TST5878)
UL1891
ERD (TST 6049i
FRSA/TRi
PLYG-SCI0130.06.16.3
6/27/2016
UL (QUA96251
Quality Control
ERD (TST 6049)
ASTM D1970, D4798
PLYG-SC8080.07.16
7/16/2016
UL (QUA9625)
Quality Control
ERD (TST 6D49)
UL1897
PLYG-SC12025.10.16
10/12/2016
UL (QUA9625)
Quality Control
MEMO I etc
Reference
Date
Mule -Hide Cross Ltg
03/01/2008
Pnlystick Compound
08/18/2011
Pnlystick Compound
01/13/2021
70ST0058-1
01/13/2021
70ST0058-6
02/17/2C21
708T0058.7
02/25/2021
Service Confirmation (FL)
09/13/2018
Service Confirmation (TX)
11/07/2019
Florida B05
Current
Product
Material Standard
Plant(s)
Description
Elastobase
ASTM D6163
FL
Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen base sheet
Elastoflex S6 G
ASTM D6164
FL, PA
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
Elastoflex S6 G FR
ASTM D6164
FL
Polyester -reinforced, SB5 modified bitumen cap sheet
FRSA/TRI 09-18
HydraGuard Dual Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
HydraGuard Tile Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
FRSA/TRI 09-18
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
Muie-Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TR109-18
Mule -Hide SA -ARP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
(FR)
FRSA/TRI 09-18
Polyflex G
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI 09-18
use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened or adhered tile
roof systems
Polyflex G FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI 09-18
use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened tile roof systems
Polyflex SA P
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI 09-18
Polyflex SA P FR
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI09-18
Polyglass Base
ASTM D6509
FL
Fiberglass -reinforced, APP modified bitumen base sheet
Polyglass G2 Base Sheet
ASTM D4601
AL
Fiberglass -reinforced, asphaltic base sheet
1.
PRODUCT
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
NEW ETC, I.I.C. Evaluation Report P12060.02,09-R29
Certificate of Authorlration#32455 7"' EDITION (2020) F8C NON-HVH7 EVALUATION FL5259-1133 (NON-HVHZ)
Polyglass Roof Underlaynnents Revision 29: 04/07/2021
Page 3 of 18
M
4.15
4.16
4.17
4.18
4.19
4.20
4.21
ONEMOletc.
.D
Product
Material Standard
Plant(s)
Description
Polystick IR-Xe
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate
surface
Polystick MTS Plus
ASTM D1970
FL, NV,
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
PA, TX
membrane, glass fiber reinforced, surfaced with
polyolefinic film surface
Polystick MU-X
ASTM D19701
FL, NV, PA
Nominal 54-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polypropylene film surface
Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane with a 190 g/ml polyester fabric surface
Polystick TU P
FRSA/TRI 09-18
FL, PA, TX
Nominal 130-mil thick rubberized asphalt waterproofing
membrane, glass-fiber/polyester reinforced, with a
granular surface
Polystick TU Plus
ASTM D1970
FL, PA, TX
Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane, glass fiber reinforced, with a polyester fabric
surface
Polystick XFR
ASTM D1970
NV, TX
Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane, glass fiber reinforced, surfaced with a
textured film surface
S. LimITATIONS:
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for
any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with
FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations
regarding roof assembly fire classification. Referto FBC 2603 for requirements and limitations concerning the use of foam plastic
insulation.
5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. if not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
Polystick MU-X has been found through comparative testing to hove a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard
laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should he established as to slip resistance.
NEMO ETC, LLC. Evaluation Report P1.2060.02.09-R29
Certificate of Authorization #32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 4 of 1S
NNEMOletC.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBC Section: 1507.2 1S07.3 1507.4 and 1507.5 1507.7 1S0L8 and 1507,9
Asphalt Clay and Concrete Tile Slate or Slate-
Underlayment Shingles Mechanical Attach Adhesive -Set Metal Type Shingles Wood
Yes Yes Yes Yes Yes Yes
Elastobase (Alternate to (as Base Sheet, (as Base Sheet, (Alternate to (Alternate to (Alternate to
D226, Type III See 5.8.3) See 5.8.3) 13226, Type II) 13226, Type Ili D226, Type II)
Yes Yes Yes Yes Yes Yes
Elastobase P (Alternate to (as Base Sheet, (as Base Sheet, (Alternate to (Alternate to (Alternate to
D226, Type II) See 5.8.3) See 5.8.3) D226, Type Ili 0226, Type II) D226, Type II)
Yes Yes
Polyglass Base No (as Base Sheet, (as Base Sheet, No No No
See 5.8.31 See 5.8.31
Yes Yes
Polyglass G2 Base No (as Base Sheet, (as Base Sheet, No No No
See 5.8.3) See 5A3)
Elastoflex 56 G No Yes Yes No No No
(See 5.6.1)
Elastoflex 56 G FIR No Yes No No No No
Yes
HydraGuard Dual Pro Yes No No Yes Yes Ooint strips, 1507.1.1.3
/ R905.1.1.3]
Yes
HydraGuard Tile Pro Yes Yes (See Yes
Yes Yes (joint strips, 1507.1.1.3
5./ R9053.1.3j
Mule -Hide SA-APP Cap Sheet No Yes Yes No No No
(See 5.6.1)
Mule -Hide SA-APP Cap Sheet (FR) No Yes Yes No No No;see 5.6.1)
Polyflex G No Yes Yes No No No
(See 5.6.1)
Polyflex G FR No Yes No No No No
Polyflex SA P No Yes Yes No No No
(See 5.6.1)
Polyflex 5A P FIR No Yes Yes No No No
(See 5.6.11
Yes
Polystick IR-Xe Yes No No No Yes Uolntstrips, 1507.1.1.3
/ R905.1.1-3)
Yes
Polystick MTS Plus Yes Yes No Yes Yes (joint strips, 1507.1.1.3
/ R905.1.1.31
Yes
Polystick MU-X Yes No No Yes Yes gointstrips, 1507.1.1.3
/ R905.1.1.3)
Yes
Polystick TU Max No Yes (seYes Yes No 6ointsirips, 1507.1.1.3
/ R905.1.1.31
Yes
Polystick TU P No Yes Yes No No (joint strips,1507.1.1.3
Y (See 5.6.1) / 11905.1.1.3)
Yes
Polystick TU Plus Yes Yes {seYe 6.1) Yes Yes (joint strips,1507.1a.3
/ R905.1.1.3)
Yes
Polystick XFR Yes Yes No Yes Yes (Joint strips, 1507.1.1.3
/ R905.1.1.3)
NEMO ETC, U.C. Evaluation Report P32060.02.09-11129
Certificate of Authorization #32455 7r" EDITION (2020) FBC NON•HVHZ EVALUATION FL5259-R33 (NON-HVHZ}
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 5 of 18
ONEMOjetc.
5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations.
TABLE 1A: ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS
Underlayment
Adhesive
Florida Product Approval
Polystick TU Max, Polystick TU P or Polystick TU Plus
DAP Foam "Touch 'n Seal
StarmBond Roof Tile Adhesive"
FL14506
Polystick TU P
DAP Foam "Touch 'n Seal
FL21374
StormBond 2 Roof Tile Adhesive"
HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick
Dupont "Tile Bond— Roof Tile
FL22525
TU Plus
Adhesive"
Elastoflex 56 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-
ICP Adhesives and Sealants
APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max,
"Polyset® AH-160"
FL6332
Polystick TU P or Polystick TU Plus
Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-
ICP Adhesives and Sealants
APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max,
"Polyset' RTA-1"
FL6276
Polystick TU P or Polystick TU Plus
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed
to meet wind loads for project)
Underlayment
Application
Type
Primer
Material(s)
HydraGuard Dual Pro,
(Optional) ASTM
plywood, OSB, Southern Yellow Pine or Huber Engineered
HydraGuard Tile Pro, Polystick IR-
Deck 1
D41
Woods "ZIP System" Panels
Xe, Polystick MTS Pius, Polystick
sheathing
ASTM D41
structural concrete
MU-X, Polystick TU Max,
self-
ASTM C1289 Type II Class 1 polyisocyan u rate, ASTM
Polystick TU P, Polystick TU Plus,
adhering
Insulation
(Optional) ASTM
C1289 Type V polyisocyanurate-composite, DensDeck
Polystick XFR, Mule -Hide SA-APP
D41 or WB-3004
Prime or SECUROCK Gypsum -Fiber Roof Board
Cap Sheet, Mule -Hide SA-APP
Cap Sheet (FR), Polyflex SA P or
Base Sheet
N/A
ASTM D226, Type II felt, Elastobase, Elastobase P or Mule -
Polyflex SA P FR
Hide Nail Base
Deck
ASTM D41
structural concrete
Insulation
(Optional) ASTM
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Elastoflex S6 G or Elastoflex S6 G
hat asphalt
Q41
FR
ASTM Q226, Type II felt, Elastobase, Elastobase P, Mule -
Base Sheet
N/A
Hide Nail Base or Polyglass G2 Base
Deck
ASTM D41
structural concrete
Insulation
(Optional) ASTM
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
torch-
Polyflex G or Polyflex G FR
applied
D41
Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass
Base Sheet
NIA
G2 Base or Polyglass Base
I Refer to Tile Manufocturet's at Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, U.C. Evaluation Report P12D60.02.09-R29
certificate ofAuthorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 6 of 18
4"
IkTNEMO I etc.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the
manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less than FBC
1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but —
for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition, Appendix A, Table 1 (for Two -
Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing
for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1
margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -52.5 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all OSB joints
Base Ply: Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#2 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#3 Maximum Design Pressure = -97.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x lY." ring shank
nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank
nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-RI9
Certificate of Authorization #32455 7TM' EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 7 of 19
ONEW10letc.
#5 Maximum Design Pressure = -135 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Joints: Min, 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#6 Maximum Design Pressure = -165 psf:
Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09, 15/32 Category to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: None
Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x I%"
ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c..
#7 Maximum Design Pressure = -202.5 psf:
Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09, 15/32 Category to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) PG100 at 0.5 gal/square
Base Ply: Polystick MTS Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1X" ring shank nails
through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%"
ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c..
#8 Maximum Design Pressure = -255 psf:
Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09, 15/32 Category to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: PG100 at 0.5 gal/square.
Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%"
ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c..
#9 Maximum Design Pressure = -315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR,
Polystick TU Max, Polystick TU P or Polystick TU Plus, self adhered.
#10 Maximum Design Pressure = -622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#11 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of -45 psf.
5.9.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design
pressure determined in accordance with FBC 1609 Or FBC Residential Chapter 3. Elevated pressure zones shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing
Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM
Loss Prevention Data Sheet 1-29 (February 2020) for enhancements.
NEMO ETC, LLC. Evaluation Report P12060.02.09-R29
Certificate of Authorization #31455 71" EDITION (20201 FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 8 of 18
ONEMOletc.
#12 Maximum Design Pressure = -30.0 psf*:
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#13 Maximum Design Pressure = -37.5 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly-fiim top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o,c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#14 Maximum Design Pressure = -37.5 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#15 Maximum Design Pressure = -45 sf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: One (1) layer ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#16 Maximum Design Pressure = -45 psf*:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Two (2) layers ASTM D226, Type II felt
Fasteners:
11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
9-inch o.c, at the 2-inch wide side laps and 9-inch o.c, at two (2) equally spaced staggered center rows.
Base Ply:
(Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment:
Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt.
#17 Maximum Design Pressure = -45 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment:
Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design
Pressure = -45.D psf:
Deck:
APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathingto meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing:
6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply:
(Optional) Polystick MTS Plus, self -adhered.
Underlayment:
Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NEMO ETC, LLC. Evaluation Report P12060.02.09-R29
Certificate ofAutharizotion #32455 7"' EDITION (2020) FOC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 9 of 18
NNEMOJetc.
#18 Maximum Design Pressure = -45.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/9" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#20 Maximum Design Pressure = -45.0 psf:
Deck: APA rated, 7/16 CAT, 0.419 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c, at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#21 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FIR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#23 Maximum Desien Pressure = -52.5 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex Original Cap Nails
Spacing:
6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment:
Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#24 Maximum Design Pressure = -60 psf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
11 ga. x 1.25-inch long x 3/S-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment:
Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#25 Maximum Design Pressure = -60 psf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing:
12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment:
Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, LLC, Evaluation Report P12060.02.09-R29
Cerrifkare of Aurhorizotion #32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 10 of 18
NNEM01 etc.
#26 Maximum Design Pressure =-60.0�sf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#27 Maximum Design Pressure = -60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#28 Maximum Design Pressure = -60.0 psf:
Deck:
APA rated, 7/1.6 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase or Polyglass Base
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment:
Polyflex G, torch -applied.
#29 Maximum Design Pressure = -67.5 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet:
Polyglass G2 Base or Polyglass Base (requires use of torch-opplied underiayment)
Fasteners:
12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment:
Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#30 Maximum Design Pressure = -67.5 psf:
Deck:
APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180" into the holes of the plate, parallel to
the width direction of the sheet.
Spacing:
12-inch o.c, at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer:
(Optional) PG100 or ASTM D41 primer applied to stress plates.
Base Ply:
(Optional) Polystick MTS Plus, self -adhered.
Underlayment:
Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#31 Maximum Design Pressure = -67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
NENIO ETC, I.LC, Evaluation Report P12060.02.09-R29
Certificateof Authorization#32455 71" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 {NON-HVHZI
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 11 of 18
4"
IT
NEMO I etc.
#32 Maximum Design Pressure = -67.5 sf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width direction of the sheet -
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#33 Maximum Design Pressure = -75 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied Underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, 01MG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#34 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#35 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with CMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c, at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex Sfi G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#36 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c, at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex Sfi G, applied in full mopping of hot asphalt.
#37 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
438 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NENIO ETC, I.I.C. Evaluation Report P12060.02.09-R29
Certificate of Authorization #32455 7"' EDITION (2020) FBC NON-HVHZ EVALUATION FL5259•R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 22 of 18
NNEM01eft.
#39 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#40 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0,418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#41 Maximum Design Pressure = -97.5 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 44rich wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#42 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c, at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#43 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0,578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#44 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#45 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, LLC. Evaluation Report P12060.02.09-1129
Certificate of Authorization A32455 7t" EDITION 120ZO) FBC NON-HVHZ EVALUATION FL5259-R33 INON-HVHZI
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 13 of 18
ONEMOletc.
446 Maximum Design Pressure = -105.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction,
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#47 Maximum Design Pressure = -105.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#48 Maximum Design Pressure = -105.0 psf:
Deck; APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#49 Maximum Design Pressure = -112.5 psf;
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
11 ga, x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin taps
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer:
PG100 or ASTM D41 primer at all tin -caps
Base Ply:
Polystick MTS Plus, self -adhered
Underlayment:
Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex 5A P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#50 Maximum Design Pressure = -120 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
OMG #12 Standard Roofgrip or CMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment:
Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
451 Maximum Design Pressure = -120 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface)
Fasteners:
Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment:
Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETC, LLC. Evaluation Report P12060.02.09-R29
certificate afAuthorization #32455 71" EDITION (20201 FBC NON•HVH7 EVALUATION FL5259•R33 (NON-HVH2)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 14 of 18
ONEMOletc.
#52 Maximum Design Pressure = -127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide 5A-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#53 Maximum Design Pressure = -127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, 056 sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction,
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt.
#54 Maximum Design Pressure = -127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Prepared Roof Cover
Installation Type
Maximum
Exposure (days)
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base
Mechanically attached
30
Polystick IR-Xe or Polystick MU-X
Mechanically attached
90
HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU Max, Polystick
TU P, Polystick TU Plus or Polystick XFR
Any type (per Table 1)
ISO
Elastoflex 56 G, Elastoflex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap
Sheet (FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR
Adhesive -set tile roof system
ISO
Mechanically attached
UNLIMITED
NEMO ETC, LLC. Evaluation Report P12060.02.09-RZ9
Cerrificare of Authorization x32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 15 of 18
ONEMOJetc.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Staging Slope
Elastoflex S6 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
Prohibited without battens
HydraGuard Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS Plus
Flat
6-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
Polystick TU P
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polystick XFR
Flat or Lugged
Prohibited without battens
Prohibited without battens
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.31 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type
II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the
manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick
MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap
Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G
FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table
1.
6.3.2 Tile Applications:
6.3.2.1 Elastobase (poly -film top), Elastobase P (poly -film top) and Mule -Hide Nail Base are limited to use as a mechanically attached
base sheet in the 'TWO-PLY SYSTEM" from FRSA/TRI Florida Nigh Wind Concrete and Cloy Roof Tile Installotion Manual, Sixth
Edition, followed by Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex
SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered or Polyflex G or Polyflex G FR, torch -applied. Tile
roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for
attachment requirements.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R29
Certificate OfAuthorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-1133 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29. 04/07/2021
Page 16 of 28
OMEMO I etc.
6.3.2.2 Elastobase (sanded -top) and Elastobase P (sanded-top)e are limited to use as a mechanically attached base sheet in the "TWO-
PLY SYSTEM" from FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition, followed by
Elastoflex S6 G, Elastoflex 56 G FR or an FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), asphalt -applied or Polyflex
G or Polyflex G FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1.
• When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by asphalt -applied Elastoflex S6 G, Elastoflex S6
G FR or FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1
or Section 5.8.3.2 herein for attachment requirements.
• When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by torch -applied Polyflex G or Polyflex G FR, refer
to Section 5.8.3.2 herein for attachment requirements.
6.4
6,4.1
6.4.2
6.4.3
HydraGuard Dual Pro, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P,
Polyflex SA P FR, Polystick IR-Xe, Polystick MTS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus or
Polystick XFR:
General:
All seal -lap seams (selvage laps) must be firmly rolled with a
in accordance with Polyglass requirements to ensure full
contact and adhesion. For HydraGuard Dual Pro and
HydraGuard Tile Pro, align the edge of the top sheet to the
end of the glue pattern (the sheet will overlap the fabric).
View of Overlap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro
Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC
1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,
and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt, Elastobase, Elastobase P or
Mule -Hide Nail Base, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
Tile Applications excludes HydraGuard Dual Pro Polystick IR-Xe and Polli,stick MU-X :
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.4.4 Multi -Ply Underlayment Systems:
Polystick MTS Plus or Polystick XFR followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU-X, Polystick
TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof
systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply
underlayment system is desired.
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not a
requirement, but is allowable if a 2-ply underlayment system is desired.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R29
Certificate oJAuthorization #32455 7m EDITION (2020) FBC NON-HVHZ EVALUATION F15259-1133 {NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 17 of 19
NNEMO I etc.
6.5 Elastoflex S6 G or Elastoflex S6 G FR:
6.5.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "Two Ply
System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the
manufacturer's installation instructions.
Refer to Section 5.8.2 and 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.6 Polyflex G or Po"ex G FR:
6.6.1 Shall be installed in compliance with requirements as an alternate to the "Heat Applied Cap Sheet" in the "Two Ply System" in
the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's
installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
18. MANUFAcTuRING PLANTS:
Contact the named CiA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section
4 herein for products and production locations having met codified material standards.
QUALITY19.
UL LLC — QUA9625; (414) 248-6409; Karen.buchmann@ul.com
- END OF EVALUATION REPORT -
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-11129
Certificate ofAuthorixation #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZi
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 18 of 18