BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
ifte: JUI Uy I 1(),% 1. Permit #:
intractor: AP'TX L
b Address: 4140 R
n: (�') New Construction — Complete ( ) Existing — After Addition
House Infiltration Test Results SLC Climate Zone 2
CFM (50) = 2DJc� Test Date:
Volume = 0 501 1
ACH (50) = CFM (50) x 60 [Volume Mechanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less (�) Pass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50-Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at anytime after creation of all penetrations of the building
;thermal envelope.
Residential
ere the air infiltration rate' of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
ssure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
ny Ne� UES, Universal Engineering Sciences Address: 607 NW Commodity Cove, PSL
hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
2quirements in accordance with Section R402.4.1.2 Climate Zone 2.
ature:
nted Name: Sean
se/Certification #: 50.5970 BPI
Duct Leakage Test Report
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: 7- 0 0 Permit #:
ilder: 'RAT44
System 1
cfm25
System 2
cfm25
System 3.
cfm25
Sum of any
cfm25
Total of all
cfm25
3-7 C) Qn
Total of all
Total Conditioned
systems
Square Footage
PASS FAI L
State: FL
Lot: / NA
Zip:
t35�
'
3'049� p. M-dd q` r26tff
"piqQa 00ub�nSilly
s
eaCe 4 dl"u:
WNdtiU rWEN 'at ,
'Aft -g M
C A 'MMIOss -JAM, t61%M 37e:R'0r.'e§tih `6
IQ.
'4fl -e
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section
553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes.
G
JAV'-.ARa� -?S
Company Name: U c V cc cs- Phone: 772-
1 hereby verify that the above'duct leaka 7,fe testing results are in accordance with the Florida Building Code requirements with the
selected compliance path as _.§t6ted o`ve, either the Prescriptive Method or Performance Method.
Signature of Tester: Date of Test:
Printed Name of Tester: _tr_S=VoZ
License/Certification #:Sc)6L[ 787 issuing Authority:
8/2019 7:46:04 AM EnergyGauge@ USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of I