Loading...
HomeMy WebLinkAboutEnergy Code. "9 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 4836 Watersong Way Builder Name: Coastal Construction Design, Inc Street: 4836 Watersong Way Permit Office: City, State, Zip: Fort Pierce , FL, 34949 Permit Number: Owner: Machesani Residence Jurisdiction: St Lucie Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�5194.4 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=20.0 4746.40 ft' b. Frame - Steel, Adjacent R=11.0 448.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Types (1854.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=22.0 1854.00 ft2 6. Conditioned floor area above grade (ft2) 4303 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c• _ 7. Windows(808.2 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic,,AH: AC 1 R ft2 6 718 a. U-Factor: Dbl, U=0.78 386.83 ft2 b. Sup: Attic, Ret: Attic, AH: AC 2 6 999 SHGC: SHGC=0.28 b. U-Factor: Dbl, U=1.06 224.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 29.4 SEER:16.00 c. U-Factor: Dbl, U=0.67 148.67 ft2 b. Central Unit 46.5 SEER:16.00 SHGC: SHGC=0.21 Area Weighted Average Overhang Depth: 4.237 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.268 a. Electric Strip Heat 20.5 COP:1.00 b. Electric Strip Heat 40.7 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2503.7 sqft.) Insulation Area EF: 0.960 a. Slab -On -Grade Edge Insulation R=0.0 937.80 ft2 b. Conservation features b. Floor Over Other Space R=0.0 838.80 ft2 None c. other (see details) R= 727.10 ft' 16. Credits None Glass/Floor Area: 0.188 Total Proposed Modified Loads: 117.71 PASS Total Baseline Loads: 1,34.72 1 hereby certify that the plans and specifications covered by Review of the plans and 4E S7, this calculation are in compliance with the Florida Energy specifications covered by this OAT �?' , _ O Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: DATE: 06/17/2021 Before construction is completed this building will be inspected for compliance with Section 553.908 * ° I hereby certify that this g s ign is in compliance the Florida Energy Florida Statutes. COD with Id. W16 OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 4.00 ACH50 (111402.4.1.2). FILE COPY 6/17/2021 8:24 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 9 FORM R405-2020 INPUT SUMMARY CHF=CKLIST REPORT PROJECT Title: 4836 Watersong Way Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 4303 Lot # Owner Name: Machesani Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Coastal Construction Design, Rotate Angle: 0 Street: 4836 Watersong Way Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: St Lucie Whole House Fan: No City, State, Zip: Fort Pierce, Family Type: Detached FL, 34949 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 AH1 2502 25387.4 2 AH 2 1801 17297.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 3rd FL Stairs 111 1043.4 No 0 1 Yes Yes Yes 2 3rd FL Hall 151 1419.4 No 0 1 Yes Yes Yes 3 Office 128 1203.2 No 0 1 Yes Yes Yes 4 3rd FL Elev 28 263.2 No 0 1 Yes Yes Yes 5 Bath 3 80 752 No 0 1 Yes Yes Yes 6 Bed 3 201 1889.4 No 0 1 1 Yes Yes Yes 7 AC 2 17 159.8 No 0 1 Yes Yes Yes 8 WIC 3 44 413.6 No 0 1 Yes Yes Yes 9 Bath 2 55 517 No 0 1 Yes Yes Yes 10 WIC 2 39 366.6 No 0 1 Yes Yes Yes 11 Hers 99 930.6 No 0 1 Yes Yes Yes 12 Bed 2 174 1635.6 No 0 1 1 Yes Yes Yes 13 His 45 423 No 0 1 Yes Yes Yes 14 M Bath 240 2256 No 0 1 Yes Yes Yes 15 Wtr Clst 21 197.4 No 0 1 Yes Yes Yes 16 Master Bedroom 368 3827.2 No 0 1 1 Yes Yes Yes 17 Flex Space 332 2988 No 0 1 Yes Yes Yes 18 Ocean Room/DR 540 5832 No 3 1 Yes Yes Yes 19 Kitchen 323 3488.4 Yes 2 1 Yes Yes Yes 20 Stairs 104 1123.2 No 0 1 Yes Yes Yes 21 Laundry 86 928.8 No 0 1 Yes Yes Yes 6/17/2021 8:24 AM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 9 FORM R4n5-202n INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 Bed 4 212 2289.6 No 0 1 1 Yes Yes Yes 23 Bath 4 77 831.6 No 0 1 Yes Yes Yes 24 2nd FL Elev 28 302.4 No 0 1 Yes Yes Yes 25 Pwdr Rm 53 572.4 No 0 1 Yes Yes Yes 26 AC 1 14 151.2 No 0 1 Yes Yes Yes 27 2nd FL Hall 126 1360.8 No 0 1 Yes Yes Yes 28 Foyer 140 1316 No 0 1 Yes Yes Yes 29 1St FL Elev 25 225 No 0 1 Yes Yes Yes 30 Stairs/Stor 102 918 No 0 1 Yes Yes Yes 31 Storage 43 383 No 0 1 Yes Yes Yes 32 Cabana 150 1350 No 0 1 Yes Yes Yes 33 W/D 34 306 No 0 1 Yes Yes Yes 34 1St FL Hall 113 1017 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Floor Over Other Space Bed 3 _-__ ____ 172.5 ft2 0 1 0 0 2 Raised Floor M Bath 140.5 ft2 19 1 0 0 3 Floor Over Other Space Master Bedroom ___ ___ 342.9 ft2 0 1 0 0 4 Slab -On -Grade Edge Insulatio Flex Space 53 ft 0 331.6 ft2 --__ 1 0 0 5 Floor Over Other Space Ocean Room/DR __-_ _-_- 323.4 ft2 0 1 0 0 6 Raised Floor Kitchen -_-- ____ 190.8 ft2 0 1 0 0 7 Raised Floor Laundry ---_ ____ 86 ft2 19 1 0 0 8 Raised Floor Bed 4 __-_ --_- 211.5 ft2 19 1 0 0 9 Raised Floor Bath 4 __- ---_ 72 ft2 19 1 0 0 10Raised Floor Pwdr Rm _-_- -__- 26.3 ft2 19 1 0 0 1lSlab-On-Grade Edge Insulatio Foyer 31 ft 0 140.3 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulatio 1St FL Elev loft 0 25 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulatio Stairs/Stor 12 ft 0 102 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulatio Storage 5 ft 0 42.5 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulatio Cabana 16.5 ft 0 150.1 ft2 -_-- 1 0 0 16SIab-On-Grade Edge Insulatio W/D 12 ft 0 33.8 ft2 -__- 1 0 0 17SIab-On-Grade Edge Insulatio 1St FL Hall 20.5 ft 0 112.5 ft2 ___- 1 0 0 6/17/2021 8:24 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 9 FORM R405-2020 INPUT SUMMARY CHF-CKLIST REPURT ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2143 ft2 0 ft2 Light N 0.3 No 0.9 No 22 30.26 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1851 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) 3rd FL Stairs 23 Blown 111 ft2 0.1 Wood 2 Under Attic (Unvented) 3rd FL Hall 23 Blown 151 ft2 0.1 Wood 3 Under Attic (Unvented) Office 23 Blown 128 ft2 0.1 Wood 4 Under Attic (Unvented) 3rd FL Elev 23 Blown 28 ft2 0.1 Wood 5 Under Attic (Unvented) Bath 3 23 Blown 80 ft2 0.1 Wood 6 Under Attic (Unvented) Bed 3 23 Blown 201 ft2 0.1 Wood 7 Under Attic (Unvented) AC 2 23 Blown 17 ft2 0.1 Wood 8 Under Attic (Unvented) WIC 3 23 Blown 44 ft2 0.1 Wood 9 Under Attic (Unvented) Bath 2 23 Blown 55 ft2 0.1 Wood 10 Under Attic (Unvented) WIC 2 23 Blown 39 ft2 0.1 Wood 11 Under Attic (Unvented) Hers 23 Blown 99 ft2 0.1 Wood 12 Under Attic (Unvented) Bed 2 23 Blown 174 ft2 0.1 Wood 13 Under Attic (Unvented) His 23 Blown 45 ft2 0.1 Wood 14 Under Attic (Unvented) M Bath 23 Blown 240 ft2 0.1 Wood 15 Under Attic (Unvented) Wtr Clst 23 Blown 21 ft2 0.1 Wood 16 Under Attic (Unvented) Master Bedroom 23 Blown 368 ft2 0.1 Wood 17 Under Attic (Unvented) Foyer 23 Blown 17 ft2 0.1 Wood 18 Under Attic (Unvented) Stairs/Star 23 Blown 12 ft2 0.1 Wood 19 Under Attic (Unvented) Storage 23 Blown 5 ft2 0.1 Wood 20 Under Attic (Unvented) Cabana 23 Blown 11 ft2 0.1 Wood 21 Under Attic (Unvented) W/D 23 Blown 8 ft2 0.1 Wood WALLS QMt Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 SW Exterior Concrete Block - Int Ins0rd FL Stairs 20 13 0 9 5 122.4 ft2 0 0 0.3 0 2 SW Exterior Concrete Block - Int Insul3rd FL Hall 20 4 0 9 5 37.7 ft2 0 0 0.3 0 3 SE Exterior Concrete Block - Int Insul Office 20 8 0 9 5 75.3 ft2 0 0 0.3 0 4 SW Exterior Concrete Block - Int Insul Office 20 16 0 9 5 150.7 ft2 0 0 0.3 0 5 SE Exterior Concrete Block - Int Insul Bath 3 20 5 6 9 5 51.8 ft2 0 0 0.3 0 6 SW Exterior Concrete Block - Int Insul Bath 3 20 3 6 9 5 33.0 ft2 0 0 0.3 0 7 NE Exterior Concrete Block - Int Insul Bed 3 20 13 6 9 5 127.1 ft2 0 0 0.3 0 8 SE Exterior Concrete Block - Int Insul Bed 3 20 14 6 9 5 136.5 ft2 0 0 0.3 0 6/17/2021 8:24 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 9 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 9 NE Exterior Concrete Block - Int Insul WIC 3 20 5 6 9 5 51.8 ft2 0 0 0.3 0 10 NE Exterior Concrete Block - Int Insul Bath 2 20 5 0 9 5 47.1 ft2 0 0 0.3 0 11 NE Exterior Concrete Block - Int Insul WIC 2 20 6 0 9 5 56.5 ft2 0 0 0.3 0 12 SW Exterior Concrete Block - Int Insul Hers 20 13 0 9 5 122.4 ft2 0 0 0.3 0 13 NE Exterior Concrete Block - Int Insul Bed 2 20 12 0 9 5 113.0 ft2 0 0 0.3 0 14 NE Exterior Concrete Block - Int Insul M Bath 20 9 6 9 5 89.5 ft2 0 0 0.3 0 15 SW Exterior Concrete Block - Int Insul M Bath 20 17 0 9 5 160.1 ft2 0 0 0.3 0 16 NW Exterior Concrete Block - Int Insul M Bath 20 14 0 9 5 131.8 ft2 0 0 0.3 0 17 SW Exterior.. Concrete Block - Int Insul Wtr Clst 20 3 6 9 5 33.0 ft2 0 0 0.3 0 18 NE Exterior Concrete Block - Int InsMasterBedro 20 18 6 10 5 192.7 ft2 0 0 0.3 0 19 NW Exterior Concrete Block - Int InsMaster Bedro 20 14 0 10 5 145.8 ft2 0 0 0.3 0 _20 NE Exterior Concrete Block - Int InsuFlex Space 20 17 0 9 0 153.0 ft2 0 0 0.3 0 _21 SE Exterior Concrete Block - Int InsuFlex Space 20 5 0 9 0 45.0 ft2 0 0 0.3 0 _22 NW Exterior Concrete Block - Int InsuFlex Space 20 18 0 9 0 162.0 ft2 0 0 0.3 0 _23 SE Garage Frame - Steel Flex Space 11 9 6 9 0 85.5 ft2 0 0.001 0.8 0 _24 NE Garage Frame - Steel Flex Space 11 3 6 9 0 31.5 ft2 0 0.001 0.8 0 25 NE Exterior Concrete Block - Int InsCIcean Room/ 20 19 0 10 10 205.8 ft2 0 0 0.3 0 26 SW Exterior Concrete Block - Int InsClcean Room/ 20 23 0 10 10 249.2 ft2 0 0 0.3 0 27 NW Exterior Concrete Block - Int InsCicean Room/ 20 27 0 10 10 292.5 ft2 0 0 0.3 0 28 NE Exterior Concrete Block - Int Insul Kitchen 20 17 0 10 10 184.2 ft2 0 0 0.3 0 29 SW Exterior Concrete Block - Int Insul Stairs 20 13 0 10 10 140.8 ft2 0 0 0.3 0 _30 NE Exterior Concrete Block - Int Insul Laundry 20 9 6 10 10 102.9 ft2 0 0 0.3 0 31 NE Exterior Concrete Block - Int Insul Bed 4 20 13 6 10 10 146.3 ft2 0 0 0.3 0 32 SE Exterior Concrete Block - Int Insul - Bed 4 20 14 0 10 10 151.7 ft2 0 0 0.3 0 33 SE Exterior Concrete Block - Int Insul Bath 4 20 5 6 10 10 59.6 ft2 0 0 0.3 0 34 SW Exterior Concrete Block - Int Insul Bath 4 20 3 6 10 10 37.9 ft2 0 0 0.3 0 35 SE Exterior Concrete Block - Int Insul Pwdr Rm 20 7 6 10 10 81.3 ft2 0 0 0.3 0 36 SW Exterior Concrete Block - Int Insul Pwdr Rm 20 7 0 10 10 75.8 ft2 0 0 0.3 0 37 SW Exterior Concrete Block - Int Insu2nd FL Hall 20 12 6 10 10 135.4 ft2 0 0 0.3 0 _38 SE Exterior Concrete Block - Int Insul Foyer 20 8 6 9 5 80.0 ft2 0 0 0.3 0 _39 SW Exterior Concrete Block - Int Insul Foyer 20 16 6 9 5 155.4 ft2 0 0 0.3 0 _40 NE Garage Frame - Steel Foyer 11 6 0 9 5 56.5 ft2 0 0.001 0.8 0 _41 SE Garage Frame - Steel 1St FL Elev 11 5 0 9 0 45.0 ft2 0 0.001 0.8 0 _42 NE Garage Frame - Steel 1St FL Elev 11 5 0 9 0 45.0 ft2 0 0.001 0.8 0 43 SW Exterior Concrete Block - Int InsuGtairs/Stor 20 12 0 9 0 108.0 ft2 0 0 0.3 0 _44 SW Exterior Concrete Block - Int Insul Storage 20 5 0 9 0 45.0 ft2 0 0 0.3 0 45 SW Exterior Concrete Block - Int Insul Cabana 20 11 0 9 0 99.0 ft2 0 0 0.3 0 v 46 NW Exterior Concrete Block - Int Insul Cabana 20 5 6 9 0 49.5 ft2 0 0 0.3 0 47 SW Exterior Concrete Block - Int Insul W/D 20 7 6 9 0 67.5 ft2 0 0 0.3 0 48 NW Exterior Concrete Block - Int Insul W/D 20 4 6 9 0 40.5 ft2 0 0 0.3 0 _49 NE Garage Frame - Steel 1St FL Hall 11 20 6 9 0 184.5 ft2 0 0.001 0.8 0 6/17/2021 8:24 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 9 DOORS I # Omt Door Type Space Storms U-Value Width Height Area I Ft In Ft In 7 1 N Wood 3rd FI- Stairs None .2 .1 .1 .1 ft2 1 WINDOWS Orientation shown is the entered. F V # Omt Wall ID Frame Panes _ 1 SW 2 Vinyl Low-E Double 2 SE 3 Vinyl Low-E Double 3 SE 5 Vinyl Low-E Double _ 4 SE 8 Vinyl Low-E Double _ 5 NE 10 Vinyl Low-E Double _ 6 NE 13 Vinyl Low-E Double _ 7 NW 16 Vinyl Low-E Double _ 8 SW 17 Vinyl Low-E Double 9 NE 18 Vinyl Low-E Double 10 NW 19 Vinyl Low-E Double 11 NE 20 Vinyl Low-E Double 12 NW 22 Vinyl Low-E Double _ 13 NE 25 Vinyl Low-E Double _ 14 NE 25 Vinyl Low-E Double 15 SW 26 Vinyl Low-E Double 16 SW 26 Vinyl Low-E Double 17 NW 27 Vinyl Low-E Double 18 NE 28 Vinyl Low-E Double 19 NE 28 Vinyl Low-E Double 20 NE 30 Vinyl Low-E Double _ 21 NE 30 Vinyl Low-E Double 22 SE 32 Vinyl Low-E Double _ 23 SE 32 Vinyl Low-E Double 24 SE 33 Vinyl Low-E Double 25 SW 36 Vinyl Low-E Double _ 26 SW 37 Vinyl Low-E Double _ 27 SW 37 Vinyl Low-E Double _ 28 SE 38 Vinyl Low-E Double 29 SW 39 Vinyl Low-E Double 30 NW 46 Vinyl Low-E Double NFRC U-Factor SHGC Yes 0.78 0.28 Yes 0.78 0.28 Yes 0.78 0.28 Yes 0.78 0.28 Yes 0.78 0.28 Yes 0.78 0.28 Yes 0.78 0.28 Yes 0.78 0.28 Yes 0.78 0.28 Yes 1.06 0.3 Yes 0.78 0.28 Yes 0.67 0.21 Yes 0.78 0.28 Yes 0.8 0.2 Yes 0.78 0.28 Yes 0.8 0.2 Yes 1.06 0.3 Yes 0.78 0.28 Yes 0.8 0.2 Yes 0.78 0.28 Yes 0.8 0.2 Yes 0.78 0.28 Yes 0.67 0.21 Yes 0.78 0.28 Yes 0.78 0.28 Yes 0.78 0.28 Yes 0.8 0.2 Yes 0.67 0.21 Yes 0.78 0.28 Yes 0.67 0.21 Overhang mp Area Depth Separati Y 16.0ft2 2ft0in 2ft0in Y 16.0ft2 2ft0in 2ft0in Y 16.0ft2 2ft0In 2ft0in Y 32.0ft2 2ft0in 2ft0in Y 16.0ft2 2ft0in 2ft0in Y 16.0ft2 2ft0in 2ft0in Y 32.0ft2 2ft0in 2ft0in Y 16.0ft2 2ft0in 2ft0in Y 32.0ft2 2ft0in 2ft0in Y 80.0ft2 9ft0in 2ft0in Y 26.7ft2 2ft0in 2ft0in Y 44.0ft2 2ft0in 2ft0in Y 37.3ft2 2ft0in 2ft0in Y 16.0ft2 2ft0in 2ft0in Y 24.9ft2 2ft0in 2ft0in Y 10.7ft2 2ft0in 2ft0in Y 144.0ft2 9ft0in 2ft0in Y 13.3ft2 2ft0in 2ft0in Y 6.7ft2 2ft0in 2ft0in Y 11.7ft2 2ft0in 2ft0in Y 5.0ft2 2ft0in 2ft0in Y 8.0ft2 6ft0in 2ft0in Y 44.0ft2 6ft0in 2ft0in Y 8.0ft2 6ft0in 2ft0in Y 14.2ft2 2ft0in 2ft0in Y 24.1 ft2 2ft0in 2ft0in Y 10.3ft2 2ft0in 2ft0in Y 44.0ft2 2ft0in 2ft0in Y 26.7ft2 2ft0in 2ft0in Y 16.7ft2 2ft0in 2ft0in Int Shade Screening Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds 'Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 6/17/2021 8:24 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 9 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000252 2845.4 156.11 293.07 .0787 4 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COPA 20.52 kBtu/hr 2 COPA 40.73 kBtu/hr 1 sys#1 sys#2 COOLING SYSTEM # l System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split Sing[ SEER: 16 29.4 kBtu/hr 882 cfm 0.85 2 S[ngl SEER: 16 46.5 kBtu/hr cfm 0.85 1 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.96 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V # — Supply — Location R-Value Area -- Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 718 ft2 Attic 6 999 ft2 Attic Attic 718 ft2 Default Leakage AC 1 (Default) (Default) 999 ft2 Default Leakage AC 2 (Default) (Default) 1 1 2 2 6/17/2021 8:24 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 9 FORM R405-2020 INPU I SUMMAKY t;Mtt;KL1, I KtrUK I TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling[[ ]] Jan [[ ]] Feb Heatin[X] Jan [X] Feb [[ jj Mar [X] Mar [ ] Apr [ j Apr [ [ ] Ma ] May Jun Jun n JulAugX] Jul n Au II'Aug Se [ I Sep [ Oct [ [ ] Oct [X] Nov Nov [ ] Dec [X] Dec Ventin II ]) Jan [[ ]l Feb [[�X]) Mar [X] A r [) Ma Jun Jul [ l Se [X) Oct [X] Nov I[ )] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH) AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD) AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 3rd FL Stairs Default(8 Ibs/sq.ft. ft2 ft 0.3 3rd FL Hall Default(8 Ibs/sq.ft. ft2 ft 0.3 Office Default(8 Ibs/sq.ft. ft2 ft 0.3 3rd FL Elev Default(8 lbs/sq.ft. ft2 ft 0.3 Bath 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bed 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 AC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hers Defauit(8 Ibs/sq.ft. ft2 ft 0.3 Bed 2 Default(8 lbs/sq.ft. ft2 ft 0.3 His Default(8 Ibs/sq.ft. ft2 ft 0.3 M Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Wtr Clst Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Flex Space Default(8 Ibs/sq.ft. ft2 ft 0.3 Ocean Room/DR Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Stairs Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Bed 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 2nd FL Elev Default(8 Ibs/sq.ft. ft2 ft 0.3 Pwdr Rm Default(8 Ibs/sq.ft. ft2 ft 0.3 AC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 2nd FL Hail Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 lbs/sq.ft. ft2 ft 0.3 1St FL Elev Default(8 lbs/sq.ft. ft2 ft 0.3 Stairs/Stor 6/17/2021 8:24 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 8 of 9 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft2 ft 0.3 Storage Default(8 Ibs/sq.ft. ft2 ft 0.3 Cabana Default(8 Ibs/sq.ft. ft2 ft 0.3 W/D Default(8 Ibs/s .ft. ft' ft 0.3 '[St FL Hall J 6/17/2021 8:24 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 9 of 9 FORM R405-2020 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the Residential Simulated Performance Alternative shall include: ❑ This checklist ❑ Form R405-2020 report ❑ Input summary checklist that can be used for field verification (usually four pages/may be greater) ❑ Energy Performance Level (EPL) Display Card (one page) ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements (five pages) Required prior to CO: ❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1- one page) ❑ A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 ❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed 2020 Duct Leakage Test Report - Performance Method (usually one page) 6/17/2021 8:23:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1