HomeMy WebLinkAboutRoof info sheetcLL! LLL -
4
rI
ST. LUCIE WORKS
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Required Sections of
Attachments Required
Roof System
the Permit Application
See List Below
Form
Low Slope Application
A, B, C
1,2,3,4,6,6,7
Prescriptive BUR-RAS 150 A, B, C
2,4,5,6,7
Asphaltic Shingles A, B, D
1,2,4,5,8,7
Concrete or Clay Tile A, R, D, F
1, 2,4,5,6,7
ht
Meta! Roofs r� A B D
1,2,3 5,6,7
Wood Shingles and I A, B, D
i,2,4,6,6,7
Shakes
As App licable
1.2,.5,6,7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page a
�`
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawing ,
3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4. Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification For Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
Form RoofinfoFeb21 Rev Feb 18, 2021
r
ST. LUCIE WORKS
Section A (General Information)
Master Permit No.
Contractors Name: Collins Roofing Inc
Job Address 5800 MYRTLE DR
Process No.
License # CCC-058011
ROOF CATEGORY
❑ Low Slope ❑ mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles
❑ Asphaltic Shingles etal Panel/Shingles Mood Shingles/Shakes
11 Prescriptive BUR-RAS 150
ROOF ROOF TYPE_- �
❑ New roof 0 Repair ❑ Maintenance Veroofing ❑ Recovering
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) 856 4 Steep Sloped Roof Area (SF) 2000 Total (SF) 2856
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
ST. LUCIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: POly9lass
Q 2'�
Product Approval No.: FL 1654 -
Design wind Pressures, From RAS 128 Or Calculations:
53 3 -53.3 -74.4 -95 8
Zone 1'. Zone 1 Zone 2: _Zone 3:
Max. Design Pressure, from the specific product approval
system:
Deck.:
Type. Plywood
Gauge Thickness: 5I8"
Slope. 1-ll21 12
Anchor/Base Sheet & No. df Ply(s).
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer!
Base Insultation Size and Thickness,
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material -
Base Sheet(s) & No. of Ply(s):
Polygiass SA-V & 1
Base Sheet Fastener/Bonding Material.
Self -Adhesive
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply: P%A ll� �
Top Ply Fastener/Bonding Material:
70 Y Ln_ Ly D
White Granular Surfaces
Surfacing:
Fastener Spacing for Anchor/Base sheet Attachment:
Zone 1':—"
oc @ Lap, # Rows— @ -- oc
Zone 1:—"
oc @ Lap, # Rows — ® O°
Zone 2:_"
oc @ Lap, # Rows — —. O°
Zone 3:_"
oc @ Lap, # Rows.— —. Oc
Number of Fasteners Per Insulation Board, -
Zone 1': Zone 1: Zone 2: Zone 3:
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterffashing, Coping, Etc
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 1 11 and Chapter 16.
AT ■ r
ST. LUCIE WORKS
Section 0 (Steep Slope Roof System)
Extreme Metal Fab
Roof System Manufacturer:
Notice of Acceptance Number: FL 17023
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): 81.7
Zone I -aZone 2e: one 2n,�Sone 2r,�one 3e' Zone 3r:
Deck Type: 5!8" Plywood
Type Underlayment I High Temp/Self Adhesive Underlayment MULE H DE SHUR
Roof Slope: C; tJfiF{U
4 12 Insulation: NIA
Fire Barrier: NIA
Ridge Ventilation? Fastener Type & Spacing: #10x1.5"-12"x12" Pattern 16" o.c. (Wood Zac)
NIA _
Adhesive Type: NIA
Type Gap Sheet NIA
Mean Roof Height: 15 ft Roof Covering: 26 Ga 5V Metal Roof Panels
Type & Size Drip 2'W" Galy. Steel
Edge: