Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 179 Phase 3 Waterstone 1512 BGLS Builder Name: ADAMS HOMES Street: 5336 Vespera Street Permit Office: City, State, Zip: Fort Pierce, FL, 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�1641.9 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1347.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 294.94 ft2 4. Number of Bedrooms 3 c. N/A d. N/A R= ft2 R= ft2 5. Is this a worst case? No 11. Ceiling Types (1512.0 sgft.) Insulation Area 6. Conditioned floor area above grade (ft2) 1512 a. Under Attic (Vented) b. N/A R=30.0 1512.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 R= ft2 7. Windows(174.2 sgft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 118.38 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 302.4 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 35.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 3.801 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.275 a. Electric Heat Pump 28.2 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A 9. Floor Types (1512.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1512:00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.115 Total Proposed Modified Loads: 49.12 PASS Total Baseline Loads: 50.05 I hereby certify that the plans d ications covere this Revie : of the plans and �HB;Or.- calculation are in compli c nergy specifications covered by this A Code. calculation indicates compliance �w r/,,''�� f PREPARED BY: with the Florida Energy Code. Before is construction completed DATE: n7-15-2n21 1810nn Kenmany this building will be inspected for w. compliance with Section 553.908 �... " I hereby certify that this building, as designed, is in compliance with the Florida E9e Code. Florida Statutes. OWNER/AGE _ _ .. BUILDING OFFICIAL: DATE: DATE: - Compliance requires certificaionby the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/15/2021 2:03 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 179 Phase 3 Waterstone Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1512 Lot # 179-3 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5336 Vespera Street Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1512 13608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1512 13608 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0 1512 ftz ---- 0.47 0 0.53 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1691 ftz 378 ftz Medium N 0.85 N 0.85 No 0 26.57 ATTIC ` / �/ # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1512 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1512 ftZ 0.11 Wood 7/15/2021 2:03 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 IAIDI IT 01I11Aeenov nu�i.v■ .■.T .■r�■�■ v■.Vvf�L1�71 RGrVI[1 WALLS Adjacent S Space P Cavity Width _ Height Sheathing Framing Solar Below 1 W 2 SE 3 S 4 SW 5 E 6 N 7 - Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Garage Frame - Wood Main 4.1 39 4.1 2 4.1 18 4.1 2 4.1 53 4.1 41 .13 35 10 3 1 3 7 2 9 8 9 8 0 8 3 8 0 8 7 8 7 8 3 348.5 ft2 18.0 ft2 149.2 ft2 18.0 ft2 459.9 ft2 353.3 ft2 294.9 ft2 0 0 0 0 0 0 0 0 0.6 0 0.6 0 0.6 0 0.6 0 0.6 0 0.6 0.23 0.01 0 0 0 0 0 0 0 DOORS # 1 2 Ornt Door Type Space S Insulated Main - Wood Main Storms None None U-Value Ft .25 3 .25 2 Width In 8 Height Ft In 6 8 6 8 Area 20 ft2 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall # Ornt ID Frame Panes NFRC 1 W 1 Vinyl Low-E Double Yes 2 W 1 Vinyl Low-E Double Yes 3 SE 2 Vinyl Low-E Double Yes 4 S 3 Vinyl Low-E Double Yes 5 S 3 Vinyl Low-E Double Yes 6 SW 4 Vinyl Low-E Double Yes 7 E 5 Vinyl Low-E Double Yes 8 E 5 Vinyl Low-E Double Yes 9 N 6 Vinyl Law-E Double Yes 10 N 6 Vinyl Low-E Double Yes 11 N 6 Vinyl Low-E Double Yes U-Factor SHGC 0.55 0.7 0.33 0.23 0.33 0.21 0.33 0.31 0.33 0.21 0.33 0.21 0.33 0.23 0.33 0.23 0.33 0.23 0.33 0.23 0.33 0.23 Imp N N N N N N N N N N N Area 17.8 ft2 6.9 ft2 10.0 ft2 3.0 ft2 15.0 ft2 10.0 ft2 9.8 ft2 16.2 ft2 30.0 ft2 23.2 ft2 32.4 ft2 Overhang Depth Separation 13 ft 0 in 1 ft 4 in 1 ft 0 in 0 ft 10 in 1 ft 0 in 1 ft 0 in 7 ft 4 in 0 ft 9 in 1 ft 4 in 1 ft 0 in 1 ft 4 in 1 ft 0 in 1.ft 4 in 1 ft 0 in 1 ft 4 in 1 ft 0 in 8 ft 4 in 0 ft 10 in 1 ft 4 in 0 ft 10 in 1 ft 4 in 0 ft 10 in Int Shade None Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Screening None None None None None None None None None None None GARAGE # 1 Floor Area Ceiling Area Exposed Wall Perimeter 390 ft2 390 ft2 64 ft Avg. Wall Height 8 ft Exposed Wall Insulation 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1587.6 87.1 163.52 .1324 7 7/15/2021 2:03 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 IIUPI IT cI IRRIMAov r►uCi+vl IL-T nr-mo%mr ...-.■� . v.....vr��w IXGwIt 1 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 28.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 28.4 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT HVAC # VProgramab4le OUT QN RLF Heat Cool Attic 6 302.4 ft Main 75.6 ft2 Default Leakage Main (Default) (Default)TEMPERATURES Thermostat: Y Ceiling Fans: Cooling Jan Feb Heating f X Jan f X� Feb Venting [ Jan [ Feb Mar Mar HX Mar Apr f A r [X] Apr Jul Mug AugSe Ma rj Jun rl Ma Jun Jul Auge May Jun Jul Sep �X� rj Oct Oct Oct Nov Nov x Nov Dec Dec H Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 78 80 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 7/15/2021 2:03 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 'FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftZ) 7. Windows- Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.21 c. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.70 d. U-Factor: other (see details SHGC: other (see details Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 5336 Vesperal Street, Fort Pierce, FL, 34951 New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1347.00 ftZ 1 b. Frame - Wood, Adjacent R=13.0 294.94 ftZ c. N/A R= ftZ 3 d. N/A R= ftZ No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1512.00 ftZ 1512 b. N/A R= ftZ Area c. N/A R= ftZ 118.38 ftZ 12. Ducts, location & insulation level R ftZ a. Sup: Attic, Ret: Main, AH: Main 6 302.4 35.00 ftZ 13. Cooling systems kBtu/hr Efficiency 17.78 ftZ a. Central Unit 28.4 SEER:15.00 3.00 ftZ 14. Heating systems kBtu/hr Efficiency 3.801 ft. a. Electric Heat Pump 28.2 HSPF:8.50 0.275 Area 15. Hot water systems ftZ a. Electric Cap: 40 gallons EF: 0.94 b. Conservation features Insulation Area None R=0.0 1512.00 ftZ Credits (Performance method) Pstat R= ftZ R= ftZ I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: \ _ Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/15/2021 2:03 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1