HomeMy WebLinkAboutAPPROVED TSP98412 plans stamp 9 28 2021(1)FLAT FLAT FLAT SYSTEM CAPACITY: 8.14 KW DC / 6.38 KW AC PV PANELS: (22) SIL-TITAN 370 NX (66 CELL) BY SIL-FAB COMBINER: (1) IQ COMBINER 3 BY ENPHASE INVERTER: (22) IQ7 PLUS MICROINVERTER BY ENPHASE RACKING SYSTEM: CROSS RAIL SYSTEM 44-X BY K2 SYSTEMS COVER SHEET C-1 1 PROJECT LATITUDE PROJECT LONGITUDE WIND EXPOSURE MIN AMBIENT TEMP MAX AMBIENT TEMP AHJ 27.412594 -80.346542 º C DESIGN WIND SPEED PROJECT DESCRIPTION C-1 COVER SHEET E-1 E-2 S-1 S-2 D-1 PV MODULES DATA SHEET GENERAL NOTES B 159 ST. LUCIE COUNTY D-2 D-3 SMART MONITORING DATA SHEET INVERTER DATA SHEET RACKING PLAN SAFETY LABELS STRUCTURAL PLAN ONE LINE RISER DIAGRAM 35 0 º C MPH C-2 SAFETY PLANS ROOF PLAN VIEW / BOS LOCATION1N.T.S. LOCATION MAP / WIND ZONES2N.T.S. IRRADIANCE MAP3N.T.S. 3D RENDERING4N.T.S. DRAWINGS INDEX PROJECT INFORMATION NORTH OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 SHARON MOSHER 09-20-2021 4026 GREENWOOD DRIVE FORT PIERCE, FL 34982 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 2421-702-0014-000-5 PARCEL NUMBER: PROJECT ID: TSP98412 DOCUMENT CONTROL 09-27-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC RC RR DATE CAD QC PER FL. STATUTE 377.705 (REVISED 7/1/2017), I RAFAEL A. GONZALEZ SOTO, P.E. 83104 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. APPLICABLE CODES: 2020 FLORIDA BUILDING CODE 7TH EDITION, ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES, FFPC 7TH EDITION, NFPA 2018, NFPA 70 AND NEC 2017. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2020 FLORIDA BUILDING CODE 7TH EDITION OR LOCAL GOVERNING CODE. ALL WIRING METHODS AND INSTALLATION PRACTICES SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE (NEC) 2017, LOCAL STATE CODES, AND OTHER APPLICABLE LOCAL CODES. MEANS SHALL BE PROVIDED TO DISCONNECT ALL CURRENT CARRYING CONDUCTORS OF THE PHOTOVOLTAIC POWER SOURCE FROM ALL OTHER CONDUCTORS IN THE BUILDING. CONNECTORS TO BE TORQUED PER DEVICE LISTING, OR MANUFACTURERS RECOMMENDATIONS. NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING. REQUIRED SAFETY SIGNS AND LABELS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE, OR OTHER MECHANICAL MEANS, LABELS SHALL COMPLY WITH ARTICLE 690 VI OF THE NEC 2017 OR OTHER APPLICABLE STATE AND LOCAL CODES. SEE LABELS AND MARKING PAGE FOR MORE INFORMATION. RACKING ROOF MOUNT SYSTEM SHALL BE INSTALLED FOLLOWING MANUFACTURERS INSTRUCTION SPEC'S, INCLUDING ALL GROUNDING WEEB CLIPS, GROUND LUGS, AND RAIL SPLICE KITS FOR ELECTRICAL CONTINUITY. MECAWIND TOOL IS BASED ON THE C&C WIND LOADS FOR ENCLOSED BUILDINGS. DESIGN WIND PRESSURES ARE CALCULATED USING ASCE 7-16 EQUATION 30.6-1. ALL NOTES IN FIGURES ASCE 7-16 30.4-1 AND 30.4-2(A,B AND /67C) HAVE BEEN INCORPORATED. MEAN ROOF HEIGHT MUST BE LESS THAN 60 FEET."PRO P E RT Y SI D E F A CI N G ST R E ET" PV DISCONNECT IQ COMBINER BOX EXISTING ELECTRICAL METER D-4 GATEWAY DATA SHEET N O R T H FLAT FLAT FLAT SAFETY PLAN C-2 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 SHARON MOSHER 09-20-2021 4026 GREENWOOD DRIVE FORT PIERCE, FL 34982 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 2421-702-0014-000-5 PARCEL NUMBER: PROJECT ID: TSP98412 DOCUMENT CONTROL 09-27-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC RC RR DATE CAD QC NOTES: 1.INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME 2.INSTALLERS SHALL UPDATE NAME ADDRESS AND PHONE NUMBER OF NEAREST URGENT CAR FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK NAME: LOCATION OF NEAREST URGENT CARE FACILITY ADDRESS: PHONE NUMBER: SAFETY PLAN1N.T.S. "PROPERTY SIDE FACING STREET" PV DISCONNECT IQ COMBINER BOX EXISTING ELECTRICAL METER 2 2P-20A 2P-20AJB NEMA3R ENVOY GATEWAY 2 8 9 40A 7 4 5 6 200A 12 1 #6 THWN-2 GROUND NEW UNDERGROUND SERVICE 240V/120V 225A BUS BAR 3 #3/0 THWN-2 INVERTER TOTAL OUTPUT: 26.62A SAFETY RATING (125%): 33.275A TOTAL PV SYSTEM OCPD: 40A MAIN BREAKER RATING: 200A BUS BAR RATING: 225A 120% BACKFEED RATING: 70A METER 13 11 9 FUSED 200A 9 10 A1.1 A1.2 A1.3 A1.4 A1.5 A1.6 A1.7 A1.8 A1.9 A1.10 A1.11 BRANCH #1 2 1 A2.1 A2.2 A2.3 A2.4 A2.5 A2.6 A2.7 A2.8 A2.9 A2.10 A2.11 BRANCH #2 2 1 PV RAILS TO BE BONDED WITH #8 BARE WIRE 3 LEGEND: 1 4 7 10 2 5 8 11 3 6 9 12 NEMA 3R JUNCTION BOX PV INTERCONNECTION POINT - LOAD SIDEPV SYSTEM DISCONNECT RATED 200A NEW UTILITY ELECTRICAL SERVICE IQ7+ MICROINVERTER BY ENPHASE REFER TO D-3 SHEET 2 #8 L1,L2 THWN-2 1 #8 THWN-2 NEUTRAL 1 #8 THWN-2 GROUND 3/4" EMT CONDUIT 4 #10 THWN-2 1 #8 THWN-2 GROUND 3/4" EMT CONDUIT IQ COMBINER BOX BY ENPHASE REFER TO D-2 SHEET 2 IQ CABLE BY ENPHASE 1 #8 BARED WIRE GROUND (22) SIL-TITAN 370 NX (66 CELL) BY SIL-FAB REFER TO D-1 SHEET 2 #2/0 L1,L2 THWN-2 1 #2/0 THWN-2 NEUTRAL 1 #6 THWN-2 GROUND 1 1/2" EMT CONDUIT TESLA GATEWAY 2 13 14 15 NOT USED INTERIOR SUB-PANEL RATED 125A NOT USED WIRE SIZES, QUANTITY & TYPE RACEWAY SIZE, TYPE, LOCATION & INFO.WIRE AMPACITY CALCULATIONS ADDITIONAL INFORMATION WIRE TAG CONDUCTOR QTY. SIZE & TYPE NEUTRAL QTY. SIZE & TYPE GROUND QTY. SIZE & TYPE RACEWAY SIZE & TYPE RACEWAY LOCATION RACEWAY HEIGHT ABOVE ROOF OUTPUT CURRENT 125% OF OUTPUT CURRRENT MIN OCPD WIRE DE-RATED CALCULATION DIST.VOLTAGE VOLTAGE DROP % CONDUIT FILL %WIRE RATING AMBIENT TEMP # OF COND. FINAL AMPACITY AC.1 (BEFORE JB) AC.2(FROM JB TO COMBINER BOX) AC.3(FROM COMBINER BOX TO SERVICE) (2) IQ CABLE BY ENPHASE (4) #10 AWG THWN-2 (2) #2/0AWG THWN-2 N/A N/A (1) #2/0 AWG THWN-2 (1) #8 AWG BARE COPPER (1) #8 AWG THWN-2 (1) #6 AWG THWN-2 NOT APPLICABLE 3/4" EMT CONDUIT 1 1/2" EMT CONDUIT UNDER ARRAY ABOVE ROOF EXTERIOR WALL 1/2" TO 3-1/2" 1/2" TO 3-1/2" "N/A" 13A 13A 26.62A 16.25A 16.25A 33.275A 20A 20A 40A 30A X 0.76 X 1 = 22.8 A 40A X 0.76 X 0.8 = 24.3 A 195A X 0.76 X 1 = 148.2 A 10 FT. 20 FT. 5 FT. 350V 350V 240V 0.11% 0.21% 0.1% 6.4% 8.1% 7.7% OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 SHARON MOSHER 09-20-2021 4026 GREENWOOD DRIVE FORT PIERCE, FL 34982 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 2421-702-0014-000-5 PARCEL NUMBER: PROJECT ID: TSP98412 DOCUMENT CONTROL 09-27-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC RC RR DATE CAD QC ONE LINE RISER DIAGRAM E-1 3 ONE LINE RISER DIAGRAM1N.T.S. CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS LOAD SIDE LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 690.13 (B) LABEL LOCATION: AC DISCONNECT, MAIN PANEL PER CODE: NEC 110.27 (C) OSHA 1910.145(f)(7) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL DO NOT DISCONNECT UNDER LOAD WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING: PHOTOVOLTAIC POWER SOURCE CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SYSTEM SHUTDOWN MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 690.15, NEC 690.13(B) WARNING SECOND SOURCE IS PHOTOVOLTAIC SYSTEM DUAL POWER SOURCE PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: 26.62 A 240V MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) 60 VDC 15.73 A INVERTER #1 240 V 60 HZ MAXIMUM AC POWER NOMINAL OPERATING AC FREQUENCY MAXIMUM AC CURRENT NOMINAL OPERATING AC VOLTAGE 6.38KW 26.62 A MAX OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION 20 A N/A LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.13 (B) LABEL LOCATION: MAIN SERVICES DISCONNECT, DC CONDUIT PER CODE: NEC 690.31 (G) (3) LABEL LOCATION: INVERTER PER CODE: NEC 690.53 LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.54 LABEL LOCATION: INVERTER PER CODE: NEC 690.52 LABEL LOCATION: MAIN SERVICE PANEL PER CODE: NEC 690.45(B)(5) LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 705.12 (B)(3) LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 705.12(B)(2)(3)(b) LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 690.33(E)(2) & NEC 690.15 (C) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT, MAIN PANEL PER CODE: NEC 690.56(C)(3) LABEL LOCATION: AC DISCONNECT POINT OF INTERCONNECTION PER CODE: NEC 690.56(C) TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. EMERGENCY RESPONDER THIS SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT, MAIN PANEL PER CODE: FFPC 7TH EDITION: 11.12.2.1.1.1.1 TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN THE ENTIRE PV SYSTEM. SAFETY LABELS E-2 4 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 SHARON MOSHER 09-20-2021 4026 GREENWOOD DRIVE FORT PIERCE, FL 34982 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 2421-702-0014-000-5 PARCEL NUMBER: PROJECT ID: TSP98412 DOCUMENT CONTROL 09-27-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC RC RR DATE CAD QC PV SAFETY LABELS DATA1N.T.S. N O R T H IQ COMBINER BOX PV DISCONNECT EXISTING ELECTRIC METER FLAT FLAT 4'-3" 4'-3" OBS OBS OBS OBS OBS OBS OBS ARRAY A TILT=12º AZIMUTH= 319º (NW) SOLAR MODULE - TYP. SEE D-1 ROOF MOUNTS LOCATED AT CENTER OF ROOF TRUSS - TYP. WOOD TRUSSES/RAFTERS LOCATION - INSTALLER MUST VERIFY IN FIELD A1.1 A1.11A2.1 A2.11 EXT.EXT. EXT.EXT. EXT.EXT. FLAT 72.13" 39.4" SIL-TITAN 370 NX (66 CELL) NOTES: -INSTALL MID CLAMPS BETWEEN MODULES AND ENDS CLAMPS AT THE END OF EACH ROW OF MODULES. -ALUMINUM RAILS SHOULD ALWAYS BE SUPPORTED BY MORE THAN ONE FOOTING ON BOTH SIDES OF THE SPLICE. UL 1703 CERTIFIED MAX. DESIGN LOAD: 79.3 psf APPLIED WIND LOAD : 53.04 psf RISK CATEGORY ZONES (PSF) PRESSURES SPAN (FT) MAX. CANTI- LEVER (IN) MAX. EXPOSURE CATEGORY ROOF SLOPE (°) ROOF TYPE ULTIMATE WIND SPEED DESIGN WIND SPEED mph mph PRESSURE ZONE: MEAN ROOF HEIGHT: PERIMETER WIDTH: KD KZT KH VELOCITY PRESSURE (q) = 0.60*0.00256* KHKZTKDV2 VELOCITY PRESSURE (ASD) TOTAL ROOF AREA sq.-ft sq.-ft TOTAL MODULES: TOTAL PHOTOVOLTAIC AREA: WIND LOAD (PSF): TOTAL WIND LOAD (LBS): TOTAL ROOF MOUNTS: TENSION FORCE PER MOUNT (LBS): INTERNAL PRESSURE COEFFICIENT 0.18 175 159 II B 12 GABLED 1&2 10.85 4.34 0.85 1.0 0.575 18.97 3,524.19 22 434.18 53.04 23,029.04 76 303.01 - - - - - - ' ' ' ' ' ' " " " " " " MATERIAL ROOF TYPE ARRAY EQUALIZATION FACTOR: a = 0.8 (PSF) INTERIOR PRESSURES (PSF) EXTERIOR PRESSURES 30.35 30.35 45.53 45.53 45.53 54.63 45.53 45.53 68.29 68.29 68.29 81.95 1 2r 2e 2n 3e 3r EXTERIOR EDGE FACTOR: E = 1.5 INTERIOR EDGE FACTOR: E = 1.0 EXTERNAL PRESSURE COEFFICIENT Z1 EXTERNAL PRESSURE COEFFICIENT Z2e EXTERNAL PRESSURE COEFFICIENT Z2n EXTERNAL PRESSURE COEFFICIENT Z2r EXTERNAL PRESSURE COEFFICIENT Z3e EXTERNAL PRESSURE COEFFICIENT Z3r 0.7 0.7 0.7 0.7 0.7 0.7 -2.0 -2.0 -3.0 -3.0 -3.0 -3.6 - - - - - - - - - - - - 2 2 2 2 2 2 8 8 8 8 8 8 41.35 41.35 60.32 60.32 60.32 71.71 METAL WORST CASE MODULE: ZONE 1: 67% ZONE 2r: 33% 45.53(0.67) + 68.29(0.33) = 53.04 psf OBS ROOF OBSTRUCTIONS PV MODULES TRUSSES OR RAFTERS ROOF MOUNTS ROOF SLOPE XX.X ARRAY # STRING # MODULE # & RAIL EXTERIOR PV MODULEEXT. STRUCTURAL PLAN S-1 5 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 SHARON MOSHER 09-20-2021 4026 GREENWOOD DRIVE FORT PIERCE, FL 34982 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 2421-702-0014-000-5 PARCEL NUMBER: PROJECT ID: TSP98412 DOCUMENT CONTROL 09-27-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC RC RR DATE CAD QC STRUCTURAL ROOF PLAN & PV MODULES LAYOUT1N.T.S. SOLAR MODULE ROOF INSPECTION NOTE: PV MODULE IN LAYOUT IS CONSIDERED NON-EXPOSED AFTER COMPLYING WITH THE FOLLOWING STATEMENTS BASED ON ASCE7-16: -NO INDIVIDUAL PV MODULE IS MORE THAN 0.5(MEAN ROOF HEIGHT) AWAY FROM ROOF EDGE OR ANOTHER MODULE. -NO INDIVIDUAL PV MODULE IS MORE THAN 4 FT AWAY FROM ROOF EDGE OR ANOTHER MODULE. -INDIVIDUAL PV MODULE IS MORE THAN 1.5(MODULE LENGTH) AWAY FROM CLOSEST EXPOSED EDGE ASCE 7.16 - 29.4-7 DESIGNED WIND PRESSURES: p = qh (GCp)(E)( a) ROOF'S GENERAL NOTES: 1- CONTRACTOR/INSTALLER TO VERIFY ROOF CONDITIONS FOR PROPER INSTALLATION OF THE PV SYSTEM. 2- CONTRACTOR/INSTALLER TO NOTIFY THE OWNER IMMEDIATELY OF ANY ROOF DEFICIENCIES AND/OR REPAIR REQUIRED TO INSTALL THE PV SYSTEM. 3- EOR DOES NOT ASSUME ANY RESPONSIBILITY FOR THE INSTALLATION OF ANY PV SYSTEM ON DEFICIENT ROOFS. 4-CONTRACTOR/INSTALLER ASSUMES ALL RESPONSIBILITY TO INSTALL AS PER MANUFACTURER STANDARDS. WEIGHTED AVERAGE LEGEND & SYMBOLS METAL ROOF MOUNT DETAIL & DATA1 N.T.S. Notes: (1) Thread must be embedded in the side grain of a Trusses or other structural member integral with the building structure. (2)Lag Bolts must be located in the middle third of the structural member. (3)These values are not valid for wet services. (4)This table does not include shear capacities. If necessary, contact a local engineer to specify lag bolt size with regard to shear forces. (5)Install lag bolts with head ad washer flush to surface (no gap). Do nor over-torque. (6)Withdrawal design values for lag screw connections shall be multiplied by applicable adjustment factors if necessary. Spruce, Pine,Per inch Thread Depth 266lbs SS Lag Bolt 5/16" x 4"Min. Thread Depth 0'-3" Wood Strength x Thread Depth = Pull Out Strength 266 lbs. x 3 in = 798 lbs. Allowable Pull Out Strength per Lag Bolt 798 lbs. Max. Pull Out Strength Required per Lag Bolt 303.01 Lag Bolt Pull Out Strength Safety Factor 2.63 S-5 BRACKET PULL OUT CALCULATIONS DISTRIBUTED LOAD CALCULATIONS PV MODULES & RACKING WEIGHT = (INDIVIDUAL MODULE WEIGHT + 3.5 LBS) * (MODULE QTY) = (47.9 LBS) * (22) = 1,053.8 LBS PER SQUARE FEET (PSF) ARRAY LOAD = PV MODULES & RACKING WEIGHT / TOTAL ARRAY AREA = 1,053.8 LBS / 434.18 SQFT = 2.43 PSF HENCE, ROOF WILL CARRY THE ADDITIONAL SOLAR SYSTEM LOAD K2 CROSSRAIL STANDARD RAIL SOLAR MODULE 5/16" Ø - 18 X 1 - 1/4" S.S. FLANGE BOLT L FOOT S-5-SOLARFOOT ATTACHEMENT <25% MODULE LENGTH TYP. "A"CROSSRAIL YETI END CLAMP 13MM HEX BOLT LOCK WASHER K2 SYSTEM 44-X Portrait 72-Cell Ground Snow Load Exposure Category Panel Angle Wind Speed 160 mph Roof Zone 1'1 2e 2r 2n 3e 3r 0 psf B 7 to 20 Array Interior 58 58 58 47 47 47 43 Array Edge 47 47 47 38 38 38 35 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 SHARON MOSHER 09-20-2021 4026 GREENWOOD DRIVE FORT PIERCE, FL 34982 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 2421-702-0014-000-5 PARCEL NUMBER: PROJECT ID: TSP98412 DOCUMENT CONTROL 09-27-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC RC RR DATE CAD QC RACKING PLAN S-2 6 PV MODULES DATA SHEET D-1 7 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 SHARON MOSHER 09-20-2021 4026 GREENWOOD DRIVE FORT PIERCE, FL 34982 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 2421-702-0014-000-5 PARCEL NUMBER: PROJECT ID: TSP98412 DOCUMENT CONTROL 09-27-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC RC RR DATE CAD QC SMART MONITORING DATA SHEET D-2 8 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 SHARON MOSHER 09-20-2021 4026 GREENWOOD DRIVE FORT PIERCE, FL 34982 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 2421-702-0014-000-5 PARCEL NUMBER: PROJECT ID: TSP98412 DOCUMENT CONTROL 09-27-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC RC RR DATE CAD QC INVERTER DATA SHEET D-3 9 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 SHARON MOSHER 09-20-2021 4026 GREENWOOD DRIVE FORT PIERCE, FL 34982 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 2421-702-0014-000-5 PARCEL NUMBER: PROJECT ID: TSP98412 DOCUMENT CONTROL 09-27-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC RC RR DATE CAD QC GATEWAY DATA SHEET D-4 10 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 SHARON MOSHER 09-20-2021 4026 GREENWOOD DRIVE FORT PIERCE, FL 34982 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 2421-702-0014-000-5 PARCEL NUMBER: PROJECT ID: TSP98412 DOCUMENT CONTROL 09-27-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC RC RR DATE CAD QC