HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
Lot 181 Phase 3 Waterstone 1512 BGRS
Street:
5328 Vespera Street
City, State, Zip:
Fort Pierce, FL , 34951
Owner:
Design Location:
FL, ST_LUCIE_CO_INTL
Builder Name: ADAMS HOMES
Permit Office:
Permit Number:
Jurisdiction: 661000
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Type$1642.6 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1347.70 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0 294.94 ft2
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
5. Is this a worst case?
No
11. Ceiling Types (1512.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1512.00 ft2
6. Conditioned floor area above grade (ft2)
1512
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
7. Windows(174.2 sqft.) Description
Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33
118.38 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 302.4
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
35.00 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55
17.78 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 3.466 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.275
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights
Area
c. U-Factor:(AVG) N/A
ft2
15. Hot water systems
SHGC(AVG): N/A
9. Floor Types (1512.0 sqft.)
Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 1512.00 ft2
b. Conservation features
EF: 0.940
b. N/A
R= ft2
None
c. N/A
R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.115
Total Proposed Modified Loads: 49.16
PASS
Total Baseline
Loads: 50.06
I hereby certify that the plans
this calculation are in complia
Code.
PREPARED BY: L..i "
DATE: r17-1.r,-2021 Wonn Kenmany
I hereby certify that this building, as designed, is in compliance
with the Florida -Ea C
OWNER/AG i
DATE:
Review'bf the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
7/15/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORON405-2020 INPI IT GI IMMARV rI4rru1 ICT DCIonOT
PROJECT
Title:
Lot 181 Phase 3 Waterstone Bedrooms: 3
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 1512
Lot #
181-3
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
5328 Vespera Street
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1512 13608
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1512 13608 Yes 4
3 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0
1512 ft2 ----
0.47 0 0.53
ROOF
/
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
V #
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 1691 ft2 378 ft2 Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
` /
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1512 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1512 ft2 0.11
Wood
7/15/2021 3:24 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPI IT CI IMMADV ruGran ICT DCDnDT
---- -------
WALLS
-
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
0
1
E
Exterior
Concrete Block - Int Insul
Main
4.1 39
10
8 9
348.5 ft2
0
0 0.6
0
2
SW
Exterior
Concrete Block - Int Insul
Main
4.1 2
3
8 0
18.0 ft2
0
0 0.6
0
3
S
Exterior
Concrete Block - Int Insul
Main
4.1 18
2
8 3
149.9 ft2
0
0 0.6
0
4
SE
Exterior
Concrete Block - Int Insul
Main
4.1 2
3
8 0
18.0 ft2
0
0 0.6
0
5
W
Exterior
Concrete Block - Int Insul
Main
4.1 53
7
8 7
459.9 ft2
0
0 0.6
0
6
N
Exterior
Concrete Block - Int Insul
Main
4.1 41
2
8 7
353.3 ft2
0
0 0.6
0
7
-
Garage
Frame - Wood
Main
13 35
9
8 3
294.9 ft2
0
0.23 0.01
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated Main
None
.25
3
6 8
20 ft2
2
Wood Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
E
1
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
13 ft 0 in
1 ft 4 in
None
None
2
E
1
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
None
3
SW 2
Vinyl Low-E Double
Yes
0.33 0.21
N
10.0 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
None
4
S
3
Vinyl Low-E Double
Yes
0.32 0.31
N
3.0 ft2
7 ft 4 in
0 ft 9 in
Drapes/blinds
None
5
S
3
Vinyl Low-E Double
Yes
0.33 0.21
N
15.0 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
None
6
SE
4
Vinyl Low-E Double
Yes
0.33 0.21
N
10.0 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
None
7
W
5
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
8
W
5
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
9
N
6
Vinyl Low-E Double
Yes
0.33 0.23
N
30.0 ft2
6 ft 8 in
0 ft 10 in
Drapes/blinds
None
10
N
6
Vinyl Low-E Double
Yes
0.33 0.23
N
23.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
11
N
6
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
390 ft2 390 ft2,
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .0004
1587.6 87.1
163.52
.1324
7
7/15/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM k405-2020 INPUT SUMMARY CHECKLIST REPf)RT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5
28.2 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftz
DUCTS
/ ---- Supply ----
---- Return---
Air
CFM 25 CFM25
HVAC #
�/ # Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic 6 302.4 ft Main
75.6 ftz Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling an Feb Mar
Heating f X� Jan H Feb Mar
HX
Apr
Apr
Jul
May Jun Jul
May rl
Jun rl
AuSep
rl Aug
Se
rl
Oct
Oct
Nov
Nov
Dec
Dec
Venting [ Jan Feb Mar
[X] Apr [
May JunJul
Aug
Se [X]
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM 78
78 78
78 78 78
78
78 80
80
80
80
PM 80
80 78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78 78
78
78
78
PM 78
78 78
78 78 78
78
78 78
78
78
78
Heating (WD) AM 66
66 66
66 66 68
68
68 68
68
68
68
PM 68
68 68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM 66
66 66
66 66 68
68
68 68
68
68
68
PM 68
68 68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
7/15/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORn R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows- Description
a. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.70
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
5328 Vespera Street, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Detached
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
1
c. N/A
3
d. N/A
No
11. Ceiling Type and insulation level
a. Under Attic (Vented)
1512
b. N/A
Area
c. N/A
118.38 ftz
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Main, AH: Main
35.00 ftz
13. Cooling systems
17.78 ftz
a. Central Unit
3.00 ftz
3.466 ft.
0.275
Area
ftz
Insulation Area
R=0.0 1512.00 ftz
R= ftz
R= ftz
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature; %' Date:
Address of New Home:
City/FL Zip:
Insulation Area
R=4.1 1347.70 ftz
R=13.0 294.94 ftz
R=
ftz
R=
ftz
Insulation
Area
R=30.0
1512.00 ftz
R=
ftz
R=
ftz
R ftz
6 302.4
kBtu/hr
Efficiency
28.4 SEER:15.00
kBtu/hr Efficiency
28.2 HSPF:8.50
Cap: 40 gallons
EF: 0.94
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/15/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1