Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 181 Phase 3 Waterstone 1512 BGRS Street: 5328 Vespera Street City, State, Zip: Fort Pierce, FL , 34951 Owner: Design Location: FL, ST_LUCIE_CO_INTL Builder Name: ADAMS HOMES Permit Office: Permit Number: Jurisdiction: 661000 County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1642.6 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1347.70 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 294.94 ft2 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1512.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1512.00 ft2 6. Conditioned floor area above grade (ft2) 1512 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(174.2 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 118.38 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 302.4 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 35.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 3.466 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.275 a. Electric Heat Pump 28.2 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A 9. Floor Types (1512.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1512.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.115 Total Proposed Modified Loads: 49.16 PASS Total Baseline Loads: 50.06 I hereby certify that the plans this calculation are in complia Code. PREPARED BY: L..i " DATE: r17-1.r,-2021 Wonn Kenmany I hereby certify that this building, as designed, is in compliance with the Florida -Ea C OWNER/AG i DATE: Review'bf the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/15/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORON405-2020 INPI IT GI IMMARV rI4rru1 ICT DCIonOT PROJECT Title: Lot 181 Phase 3 Waterstone Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 1512 Lot # 181-3 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5328 Vespera Street Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1512 13608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1512 13608 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0 1512 ft2 ---- 0.47 0 0.53 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1691 ft2 378 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC ` / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1512 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1512 ft2 0.11 Wood 7/15/2021 3:24 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPI IT CI IMMADV ruGran ICT DCDnDT ---- ------- WALLS - Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 E Exterior Concrete Block - Int Insul Main 4.1 39 10 8 9 348.5 ft2 0 0 0.6 0 2 SW Exterior Concrete Block - Int Insul Main 4.1 2 3 8 0 18.0 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Int Insul Main 4.1 18 2 8 3 149.9 ft2 0 0 0.6 0 4 SE Exterior Concrete Block - Int Insul Main 4.1 2 3 8 0 18.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block - Int Insul Main 4.1 53 7 8 7 459.9 ft2 0 0 0.6 0 6 N Exterior Concrete Block - Int Insul Main 4.1 41 2 8 7 353.3 ft2 0 0 0.6 0 7 - Garage Frame - Wood Main 13 35 9 8 3 294.9 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Main None .25 3 6 8 20 ft2 2 Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 13 ft 0 in 1 ft 4 in None None 2 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 SW 2 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 S 3 Vinyl Low-E Double Yes 0.32 0.31 N 3.0 ft2 7 ft 4 in 0 ft 9 in Drapes/blinds None 5 S 3 Vinyl Low-E Double Yes 0.33 0.21 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 6 SE 4 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 7 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 8 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 9 N 6 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 6 ft 8 in 0 ft 10 in Drapes/blinds None 10 N 6 Vinyl Low-E Double Yes 0.33 0.23 N 23.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 11 N 6 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 390 ft2 390 ft2, 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1587.6 87.1 163.52 .1324 7 7/15/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM k405-2020 INPUT SUMMARY CHECKLIST REPf)RT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 28.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 28.4 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS / ---- Supply ---- ---- Return--- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 302.4 ft Main 75.6 ftz Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling an Feb Mar Heating f X� Jan H Feb Mar HX Apr Apr Jul May Jun Jul May rl Jun rl AuSep rl Aug Se rl Oct Oct Nov Nov Dec Dec Venting [ Jan Feb Mar [X] Apr [ May JunJul Aug Se [X] Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 7/15/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORn R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Windows- Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.21 c. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.70 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 5328 Vespera Street, Fort Pierce, FL, 34951 New (From Plans) 10. Wall Type and Insulation Detached a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Adjacent 1 c. N/A 3 d. N/A No 11. Ceiling Type and insulation level a. Under Attic (Vented) 1512 b. N/A Area c. N/A 118.38 ftz 12. Ducts, location & insulation level a. Sup: Attic, Ret: Main, AH: Main 35.00 ftz 13. Cooling systems 17.78 ftz a. Central Unit 3.00 ftz 3.466 ft. 0.275 Area ftz Insulation Area R=0.0 1512.00 ftz R= ftz R= ftz 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature; %' Date: Address of New Home: City/FL Zip: Insulation Area R=4.1 1347.70 ftz R=13.0 294.94 ftz R= ftz R= ftz Insulation Area R=30.0 1512.00 ftz R= ftz R= ftz R ftz 6 302.4 kBtu/hr Efficiency 28.4 SEER:15.00 kBtu/hr Efficiency 28.2 HSPF:8.50 Cap: 40 gallons EF: 0.94 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/15/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1