HomeMy WebLinkAboutAPPROVED ROOFINFO�CL IL4�1 .1, - �01
r
STr LUCIE
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
Roof System
Required Sections of
the Permit Application
Form
Attachments Required
See List Below
Low Slope Application
A, B, C
1,2,3,4,6.6,7 .
Prescriptive BUR-RAS 150
A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
1,2,4,5,6,7
Concrete or Clay Tile
A, B, D, E
1,2,3,4,5,6,7
Metal Roos
A, B, D
Wood Shingles and
Shakes
A, B, D
1,2,4,5,6,7
Other
As Applicable
1,2,3,4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1.
Fire Directory Listing Page
2.
From Product Approval;
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7,
Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
ST. LUCIE
Section A (General Information)
Master Permit No.
Process No.
Contractors Name: 3� ce L ct rC/ License N GGG 133 Z 3'4L
Job Address 2--0 3 5 1I7(!,t;za Ai ✓0y- 2>Y
ROOF CATEGORY
❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles
❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ New roof ❑ Repair ❑ Maintenance [}'Reroofing ❑ Recovering
. ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) 11 O b Total (SF) (I D O
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
I
I
�K---- -_-D�
J
i
ST. LUCIE
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval No.:
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': Zone 1: Zone 2: zone 3:
Max. Design Pressure, from the specific product approval
system:
Deck:
Type:
Gauge Thickness:
Slope:
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Mate 'al:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickne
Top Insulation Fastener/Bondiate n riak
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Bonding Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':—"
oc @ Lap, # Rows— ® "o
Zone 1:_"
oc @ Lap, # Rows — — oo
Zone 2:�"
oc @ Lap, # Rows — ® "00 '
Zone 3:_"
oc @ Lap, # Rows— ® — ac
Number of Fasteners Per Insulation Board:
Zone 1':_Zone 1:_Zone 2:—Zone 3:—
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
t,sling, Continuous Cleat, Cant Strip, Base Flashing,
Counte 'ng, Coping, Etc..
Indicate: can Roo eight, Parapet Height, Height of Base
Flashin Component Material, Material' Thickness, Fastener
Type, stener5pacingorSubmitManufacturersDetailsthat
m ly with RAS 111 and Chapter 16..
ST. LUCIE
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mrwith the values from Mr. If the Mf values
are greater than or equal to the M,values, for each area of the roof, then the tile attachment method is acceptable.
Method 1 'Moment Based Tile Calculations Per RAS 12T
(Zone 1:
_xa,_=
_j_Mg: _=Mn_
Product Approval Mi
(Zone2e:
_xX_=—
Mg:
_=MR .—
Product Approval Mr
(Zone 2n:
_x 1^=
_) -- Mg:
_= Mom,_
Product Approval Mf
(Zone2r:
_x),_=
)-Mg:
_=M
- Product ApprovalMf
(Zone 3e: ''_x
X _=
- Mg:
_= M,y_
Product Approval Mf
(Zone3r:
_xx_=
Mg:
MO
Product ApprovalMi
Method 2 "Simplified Tile
Calculati
ins Per le Below"
Required Moment of Resistance (Mr) From Table Below
Produ
' pproval P
Mr required Moment Resistance
Mean Roof Height Roof Slope
is,
20'
25'
3
0'
2:12
34.4
36.5
38.2
.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
3.8
35.1
37.3
5:12
28.4
.1
3 6
2.8
34.9
6:12
26.4
28.
29.4
.5
32.4
7:12
24.4
259
27.1
2
30.0
"Must be used in conjunction with a list of moment bas the systems
• For Uplift based tile systems use Method 3. Compare the alues for F' with th
equal to the Fr values, for each area of the roof, then the til attachment metho
Method 3 "Uplift Based Ti Calculations Per
(Zone 1:
x L
=x W:= ) -W:
cos ir
(Zone 2e:
x L=
x W:= ) -W:
cos r
(Zone 2n:
x L
=x W:=) -W:
cos r
(Zone 2r:
x L=
x W:= ) -W:
cos r
(Zone 3e:
x L
=x W:=
cos r
(Zone 3r:
x L=
x W:= ) W:
cos r
res for Fr If the F' values are greater than or
acceptable.
Product A ooroval F',
Product Approval F'_
Product Approval F'
Product Approval F
Product Approval F'
Product Approval F'
Where to Obtain Information
Description
Sym I
Where to find
Design Pressure
Zones 1, 2e, 2n, 2r, 3e, 3r
From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
8
Job Site
Aerodynamic Multiplier
a -
Product Approval
Restoring Moment due to Gravity
Mg
Product Approval
Attachment Resistance
Mr
Product Approval
Required Moment Resistance
Mg
Calculated
Minimum Attachment Resistance
F
Product Approval
Required Uplift Resistance
F,
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L = length W = width
Product Approval
All calculations must be submitted to the building official at the time of permit application.
ST. LUCIE
Section D (Steep Slope Roof System)
Roof System Manufacturer. n G , L
Notice of Acceptance Number:
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1:-" Zone 2e: - k- Zone 2n:- 1.5LZone 2r:fi3-LZone 3e:— Zone 3r: —lrj,b
Deck Type: woo ArGOA
Type Underlayment: I F
Roof Slope:
121 A/ ---�
Insulation:
Fire Barrier:
Ridge VgIniilation? Fastener Type & Spacing:
YO Gr y Rr� a
Adhesive Type:
Type Gap Sheet:
r
Mean Roof Height: �fl Roof Covering; �H 1 �� /�%►i�.�'i
Type & Size Dripy A X�
Edge: