HomeMy WebLinkAboutEnergy Efficiency zCodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KHOV-LELIA
Builder Name: KHOVNANAIN HOMES
Street: 5109 ARMINA PLACE
Permit Office:
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: LELIA MODEL LOT 31 @ WATERSTONE
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type$1844.9 sqft.)
Insulation Area
2. Single family or multiple family detached
a. Concrete Block - Int Insul, Exterior
1 1508.90 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
11.0 336.00 ft2
c. NIA
R= ft2
4. Number of Bedrooms 4
d. NIA
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1917.0 sqft.)
Insulation Area
a. Under Attic (Vented)
1 1917.00 ft2
6. Conditioned floor area above grade (ft2) 1917
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
7. Windows(201.8 sqft,) Description Area
12. Ducts
R ft2
a U-Factor: Di 11i 159.83 ft2
a. Sup: Attic, Ret: LAUNDRY, AH: LAUNDRY 6 250
Si SHGC=0.30
b. U-Factor: Dbl, U=0,55 42.00 ft2
13. Cooling systems
kBtulhr Efficiency
Si SHGC=0.34
a. Central Unit
35.2 SEER:16.00
c. U-Factor: NIA ft2
Si
Area Weighted Average Overhang Depth: 1.570 ft.
14. Heating systems
kl3tulhr Efficiency
Area Weighted Average Si 0.308
a. Electric Strip Heat
32.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): NIA
a. Electric
Cap: 50 gallons
9. Floor Types (1917.1 sqft.) Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation 1 1917.10 ft2
b. Conservation features
b. NIA R= ft2
None
c. NIA R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 59.66
Glass/Floor Area: 0.105
PASS
Total Baseline Loads: 61.14
I hereby certify that the plans and pecifications covered by
Review of the plans andT
S7 q
this calculation are in compliance ith the Flor'da Energy
specifications covered by this
4V
Code,
calculation indicates compliance
with the Florida Energy Code.
r+rr,�' , =. o: ,••` „s+
PREPARED BY:
Before construction is completed
axr• • ,:`
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
C'Dfj ,
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
7/13/2021 8:04 AM EnergyGaugeb USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: KHOV-LELIA
Bedrooms: 4
Address Type:
Street Address
Building Type: User
Conditioned Area: 1917
Lot #
Owner Name: LELIA MODEL LOT 31 @ WA
Total Stories: 1
Block/Subdivision
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: KHOVNANIAIN HOMES
Rotate Angle: 0
Street:
5109 ARMINA PLACE
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FORT PIERCE,
Family Type: Detached
FL
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name. Area
Volume
1 Entire House 1917
16614.7
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 EXT STE LIV PLUS 199
1765.1 No
0
4
1
No
Yes
Yes
2 WIG STE PLS BED 25
220 No
0
1
No
Yes
Yes
3 EX STE PLUS BED 132
1161.6 No
0
1
No
Yes
Yes
4 EX STE BATH 54
475.2 No
0
1
No
Yes
Yes
5 FOYER 81
712.8 No
0
1
No
Yes
Yes
6 HALL BATH 54
475.2 No
0
1
No
Yes
Yes
7 LAUNDRY 77
677.6 No
0
1
No
Yes
Yes
8 BED 3 126
1108.8 No
1
1
No
Yes
Yes
9 BED 2 126
1109 No
1
1
No
Yes
Yes
10 KIT GREAT RM DI 672
6644.8 No
0
1
No
Yes
Yes
11 M BATH 95
836 No
0
1
No
Yes
Yes
12 MASTER SUITE 210
1848 No
2
1
No
Yes
Yes
13 MASTER WIC 66
580.8 No
0
1
No
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tiie Wood
Carpet
1 Slab -On -Grade Edge Insulatio EXT STE LIV PL 46 ft 0
199.3 ftz
----
0 1
0
2 Slab -On -Grade Edge Insulatio WIC STE PLS BE 4.5 ft 0
25 ftz
----
0 1
0
3 Slab -On -Grade Edge Insulatio EX STE
PLUS B 8.5 ft 0
132 ft2
___-
0 1
0
4 Slab -On -Grade Edge Insulatio EX STE BATH 1 ft 0
54 ftz
--_-
1 0
0
7/13/2021 8:04 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulatio
FOYER 19 ft
0
81.3 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulatio
HALL BATH 1 ft
0
54 ft2
----
1
0
0
7 Slab -On -Grade Edge Insulatio
LAUNDRY 7.5 ft
0
77 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulatio
BED 3 22.5 ft
0
126 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio
BED 2 12.5 ft
0
126 ft2
----
0
1
0
10Slab-On-Grade Edge Insulatio
KIT GREAT RM 43.5 ft
0
672 ft2
_---
1
0
0
11SIab-On-Grade Edge Insulatio
M BATH 9 ft
0
94.5 ft2
----
1
0
0
12SIab-On-Grade Edge Insulatio
MASTER SUITE 28 ft
0
210 ft2
----
0
1
0
135iab-On-Grade Edge Insulatio
MASTER WIG 6 ft
0
66 ft2
----
0
1
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Composition shingles 2076 ft2
0 ft2 Medium
N
0.9
No 0.9
No 0
22.6
ATTIC
V # Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1917 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
EXT STE LIV PL
30
Blown
199 ft2
0A
Wood
2 Under Attic (Vented)
WIC STE PLS BE
30
Blown
25 ft2
0.1
Wood
3 Under Attic (Vented)
EX STE PLUS B
30
Blown
132 ft2
0A
Wood
4 Under Attic (Vented)
EX STE BATH
30
Blown
54 ft2
0.1
Wood
5 Under Attic (Vented)
FOYER
30
Blown
81 ft2
0.1
Wood
6 Under Attic (Vented)
HALL BATH
30
Blown
54 ft2
0A
Wood
7 Under Attic (Vented)
LAUNDRY
30
Blown
77 ft2
0.1
Wood
8 Under Attic (Vented)
BED 3
30
Blown
126 ft2
0A
Wood
9 Under Attic (Vented)
BED 2
30
Blown
126 ft2
0A
Wood
10 Under Attic (Vented)
KIT GREAT RM
30
Blown
672 ft2
0.1
Wood
11 Under Attic (Vented)
M BATH
30
Blown
95 ft2
0.1
Wood
12 Under Attic (Vented)
MASTER SUITE
30
Blown
210 ft2
0.1
Wood
13 Under Attic (Vented)
MASTER WIC
30
Blown
66 ft2
0.1
Wood
7/13/2021 8:04 AM EnergyGaugeS USA 7.0.00 - RaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY rW1=rKI IqT RFPnRT
WALLS
Adjacent
SpaceFt
Cavity
Width
In
Height
Ff In
Area
Sheathing Framing
R-Vab-
Solar
Abqnr
Below
o
1
SE
Exterior
Concrete Block - Int InsEKT STE LIV
4A
11
7
9
4
108.1 ft2
0
on
0
0.5
0
2
SW
Exterior
Concrete Block - Int InsFHXT STE LIV
4.1
15
4
10
0
153.3 ft2
0
0
0.5
0
3
SW
Exterior
Concrete Block - Int InsiHX STE PLU
4.1
7
8
10
0
76.7 ft2
0
0
0.5
0
4
SE
Exterior
Concrete Block - Int Insul FOYER
4.1
6
4
9
4
59.1 ft2
0
0
0.5
0
5
SW
Exterior
Concrete Block - Int Insul FOYER
4A
11
4
10
0
113.3 ftz
0
0
0.5
0
6
NE
Exterior
Concrete Block- Int Insul BED 3
4.1
11
7
9
4
108.1 ft2
0
0
0.5
0
7
NE
Exterior
Concrete Block- Int Insul BEd 2
4.1
11
7
9
4
108.1 ft2
0
0
0.5
0
8
SW
Exterior
Concrete Block - Int InsLKIT GREAT
4.1
25
2
10
0
251.7 ft2
0
0
0.5
0
9
NW
Exterior
Concrete Block - Int InsLKIT GREAT
4.1
15
1
9
4
140.8 ftz
0
0
0.5
0
10
NE
Exterior
Concrete Block - Int Insul M BATH
4.1
8
9
9
4
81.7 ftZ
0
0
0.5
0
11
NE
Exterior
Concrete Block - Int InsMASTER SUI
4.1
14
1
9
4
131.4 ftz
0
0
0.5
0
12
NW
Exterior
Concrete Block - Int InsMASTER SUI
4.1
13
1
9
4
122.1 ft2
0
0
0.5
0
13
NW
Exterior
Concrete Block - Int InsWASTER WI
4A
5
10
9
4
54.4 ft2
0
0
0.5
0
14
NW
Garage
Frame - Wood KIT GREAT
11
36
0
9
4
336.0 ft2
0
0
0.5
0
DOORS
#
Ornt
door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SW
Insulated EXT STE LIV
None
.39
3
2
6 8
21.1 ft2
2
SW
Insulated EXT STE LIV
None
.39
3
2
6 8
21.1 ft2
3
NW
Wood KIT GREAT
None
.39
3
2
6 8
21.1 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation_
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
SE 1
Metal Double (Tinted) Yes
0.28
0.3
N
22.9 ft2
1 ft 0 in
1 ft 0 in
None
None
2
SW 3
Metal Double (Tinted) Yes
0.28
0.3
N
23.0 ft2
6 ft 0 in
1 ft 0 in
None
None
3
SW 5
Metal Double (Tinted) Yes
0.28
0.3
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
4
NE 6
Metal Double (Tinted) Yes
0.28
0.3
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
5
NE 7
Metal Double (Tinted) Yes
Q 28
0.3
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
6
SW 8
Metal Double (Tinted) Yes
0.28
0.3
N
23.0 ft2
1 ft 0 in
1 ft 0 in
None
None
7
NW 9
Metal Double (Tinted) Yes
0.28
0.3
N
23.0 ft2
1 ft 0 in
1 ft 0 in
None
None
8
NW 9
Metal Double (Tinted) Yes
0.55
0.34
N
42.0 ft2
1 ft 0 in
1 ft 0 in
None
None
9
NW 12
Metal Double (Tinted) Yes
0.28
0.3
N
22.9 ft2
1 ft 0 in
1 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
380 ft2 380 ft2
64 ft
8 ft
1
7/13/2021 8:04 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Whoiehouse Proposed ACH(50)
.000385
1938.4 106.35 1W65 .1304
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1 32 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Sing{ SEER: 16 35.2 kBtu/hr cfm
0.81 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
---- Return ---- Air CFM 25 CFM25
HVAC #
V/ # Location R-Value Area
Location
Area Leakage Type Handler TOT OUT
ON RLF
Heat Cool
1 Attic 6 250 ft2
LAUNDRY
1 ft2 Default Leakage LAUNDRY (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin an ]] Feb [ ]] Mar
He atinf X] Jan Feb [X] Mar
Apr
f Apr f
Ma X Jun X Jul rj Au Se
May 4 Jun Jul Auri Sep f
Oct Nov
Oct X� Nov
Dec
f X� Dec
lX]
Venting[ ] Jan [ ]] Feb [X]] Mar
jX Apr [
May [ Jun Jul Aug Se [
Oct [X Nov
[ ] Dec
7/13/2021 8:04 AM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
80 80
80
80
78
78
78
78
78
78 78
78
78
Cooling (VVEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78 78
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD)
AM
66
66
66
66
66
58
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH)
AM
66
66
66
66
fib
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
Oft
0.3
BED 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC BED 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN DINING
Default(8 lbs/sq.ft.
ft2
ft
0.3
GREAT ROOM
Default(8 lbs/sq ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0,3
M Wic
Default(8 lbslsq ft.
ft2
ft
0.3
M TIOLET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/s .ft.
ft2
ft
0.3
MASTER SUITE
7/13/2021 8:04 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: Dbl, U=0.28
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.34
c. U-Factor: NIA
SHGC:
d. U-Factor: NIA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): NIA
SHGC(AVG): NIA
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. NIA
c. NIA
0109 ARMINA PLACE, FORT PIERCE, FL,
New (From Plans)
10. Wail Type and Insuiation
Insulation
Area
Detached
a. Concrete Block - Ink Insul, Exterior
R=4.1
1508.90 ft2
b. Frame - Wood, Adjacent
R=11.0
336.00 ft2
1
c. NIA
R=
ftZ
4
d. NIA
R=
ft2
N0
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1917.00 ft2
1917
b. N/A
R=
ft2
Area
c. NIA
R=
ft2
159 83 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: LAUNDRY, AK LAUNDRY
6 250
42.00 ft2
13. Cooling systems
kBtulhr
Efficiency
ft2
a. Central Unit
35.2
SEER:16.00
ft2
1.570 ft.
0.308
Area
ft2
Insuiation Area
R=0.0 1917.10ft2
R= ft2
R= ft2
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
kBtulhr Efficiency
32.0 COPA.00
Cap: 50 gallons
EF: 0.95
Pstat
t ksT
y �Q
0QD
'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/13/2021 8:04 AM Energy0auge0 USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1