Loading...
HomeMy WebLinkAboutLateral Toe-Nail DetailedOCTOBER 1, 2006 1 LATERAL TOE -NAIL DETAIL I ST-TOENAIL 01_10 �JQ �a MiTek Industries, Inc. MiTek Industries, Chesterfield, MO Page 1 of 1 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD, 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE BOTTOM CHORD SPECIES FOR MEMBERS OF DIFFERENT SPECIES, TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (lb/nall) DAM. SYP OF HE SEE SPF-S Le .131 88.1 80.6 69.9 68.4 59.7 p .135 93.5 85.6 74.2 72.6 63.4 to .162 118.3 108.3 93.9 91.9 80.2 O' Z .128 84.1 76.9 1 66.7 65.3 57.0 .131 88.1 80.6 69.9 68.4 59.7 N .148 106.6 97.6 84.7 82.8 72.3 M (9 .120 73.9 67.6 58.7 57.4 50.1 O .128 84.1 76.9 66.7 65.3 57.0 - .131 88.1 80.6 69.9 68.4 59.7 `� .148 106.6 97.6 84.7 82.8 72.3 VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OE LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3)- 16d NAILS (.162" diam. x 3.5")WITH SPF SPECIES BOTTOM CHORD For load duration increase of 1,15: 3 (nails) X 91.9 (lb/nail) X 1.15 (DOL) = 317.0 lb Maximum Capacity L/2 L/2 VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY 45 DEGREE ANGLE BEVEL CUT SIDE VIEW (2x3, 2x4) 2 NAILS NEAR SIDE NEARSIDE 45.000 j� SIDE VIEW / x 3 3 NAILS NEARSIDE NEAR SIDE \ NEAR SIDE SQUARE CUT SIDE VIEW (2x4, 2x6) 3 NAILS NEAR SIDE --I FAR SIDE NEAR SIDE SIDE VIEW (2x 2 NAILS NEARSIDE -i FAR SIDE OCTOBER 1, 2006 �flQ E: jMa MITek Industries, Inc. LATERAL TOE -NAIL DETAIL ( ST-TOENAIL_SP MITek Industries, Chesterfield, MO Page 1 of 1 NOTES; 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45 DEGREES WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT. (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES, TOE -NAIL SINGLE SHEAR VALUES PER NDS 2001 (lb/nail) DIAM. SYP DF HF SPF I SPF-S O .131 88.0 80.6 1 69.9 1 68.4 59.7 p .135 93.5 85.6 74.2 72,6 63.4 J - .162 108.8 99.6 86.4 84.5 73.8 O z .128 67.9 58.9 57.6 50.3 .131 q 69.5 60.3 59.0 51.1 c`u .148 74.5 64.6 63.2 52.5 VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (.162 diam. x 3.5")WITH SPF SPECIES BOTTOM CHORD For load duration increase of 1.15: 3 (nails) X 84.5 (lb/nail) X 1.15 (DOL) = 291.5 lb Maximum Capacity ANGLE MAY VARY FROM 30° TO 60° 45.00° ANGLE MAY VARY FROM 30° TO 60° THIS DETAIL APPLICABLE TO THE THREE END DETAILS SHOWN BELOW VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY SIDE VIEW SIDE VIEW (2NAILS ) 2 NAILS 3 NA 3 NAILS NEAR SIDE NEARSIDE Ivi NEAR SIDE NEARSIDE NEAR SIDE iz 45,00° ANGLE MAY VARY FROM 30° TO 60° 45.00°