HomeMy WebLinkAboutLateral Toe-Nail DetailedOCTOBER 1, 2006 1 LATERAL TOE -NAIL DETAIL I ST-TOENAIL
01_10
�JQ
�a
MiTek Industries, Inc.
MiTek Industries, Chesterfield, MO Page 1 of 1
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES WITH THE MEMBER
AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD,
3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE BOTTOM CHORD SPECIES
FOR MEMBERS OF DIFFERENT SPECIES,
TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (lb/nall)
DAM.
SYP
OF
HE
SEE
SPF-S
Le
.131
88.1
80.6
69.9
68.4
59.7
p
.135
93.5
85.6
74.2
72.6
63.4
to
.162
118.3
108.3
93.9
91.9
80.2
O'
Z
.128
84.1
76.9
1 66.7
65.3
57.0
.131
88.1
80.6
69.9
68.4
59.7
N
.148
106.6
97.6
84.7
82.8
72.3
M
(9
.120
73.9
67.6
58.7
57.4
50.1
O
.128
84.1
76.9
66.7
65.3
57.0
-
.131
88.1
80.6
69.9
68.4
59.7
`�
.148
106.6
97.6
84.7
82.8
72.3
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OE LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3)- 16d NAILS (.162" diam. x 3.5")WITH SPF SPECIES BOTTOM CHORD
For load duration increase of 1,15:
3 (nails) X 91.9 (lb/nail) X 1.15 (DOL) = 317.0 lb Maximum Capacity
L/2
L/2
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
45 DEGREE ANGLE
BEVEL CUT
SIDE VIEW
(2x3, 2x4)
2 NAILS
NEAR SIDE
NEARSIDE
45.000
j� SIDE VIEW
/ x 3
3 NAILS
NEARSIDE
NEAR SIDE
\ NEAR SIDE
SQUARE CUT
SIDE VIEW
(2x4, 2x6)
3 NAILS
NEAR SIDE
--I FAR SIDE
NEAR SIDE
SIDE VIEW
(2x 2 NAILS
NEARSIDE
-i FAR SIDE
OCTOBER 1, 2006
�flQ
E: jMa
MITek Industries, Inc.
LATERAL TOE -NAIL DETAIL ( ST-TOENAIL_SP
MITek Industries, Chesterfield, MO Page 1 of 1
NOTES;
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45 DEGREES WITH THE MEMBER
AND MUST HAVE FULL WOOD SUPPORT. (NAIL MUST BE DRIVEN THROUGH AND
EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES
FOR MEMBERS OF DIFFERENT SPECIES,
TOE -NAIL SINGLE SHEAR VALUES PER NDS 2001 (lb/nail)
DIAM.
SYP
DF
HF
SPF
I SPF-S
O
.131
88.0
80.6
1 69.9
1 68.4
59.7
p
.135
93.5
85.6
74.2
72,6
63.4
J
-
.162
108.8
99.6
86.4
84.5
73.8
O
z
.128
67.9
58.9
57.6
50.3
.131
q
69.5
60.3
59.0
51.1
c`u
.148
74.5
64.6
63.2
52.5
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (.162 diam. x 3.5")WITH SPF SPECIES BOTTOM CHORD
For load duration increase of 1.15:
3 (nails) X 84.5 (lb/nail) X 1.15 (DOL) = 291.5 lb Maximum Capacity
ANGLE MAY
VARY FROM
30° TO 60°
45.00°
ANGLE MAY
VARY FROM
30° TO 60°
THIS DETAIL APPLICABLE TO THE
THREE END DETAILS SHOWN BELOW
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
SIDE VIEW SIDE VIEW
(2NAILS )
2 NAILS
3 NA
3 NAILS
NEAR SIDE NEARSIDE
Ivi
NEAR SIDE NEARSIDE
NEAR SIDE
iz
45,00°
ANGLE MAY
VARY FROM
30° TO 60°
45.00°