6904 Parke East Blvd. Tampa, FL 33610-4115 MiTek USA, Inc. RE: WS0031 - Design Code: FBC2020/TPI2014 Wind Code: ASCE 7-16 Wind Speed: 165 mph Roof Load: 37.0 psf Design Program: MiTek 20/20 8.4 1 of 2 This package includes 33 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Floor Load: N/A psf Site Information: Lot/Block: 31 Customer Info: K Hovnanian Homes Project Name: WS0031 Model: Lelia-A Subdivision: Waterstone Address: 5109 Armina Pl., . State: FLCity: Fort Pierce Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: July 12,2021 Velez, Joaquin The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource - Plant City. Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2023. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. No.Seal#Truss Name 1 T24642126 CJ1 Date 7/12/212T24642127CJ37/12/213T24642128CJ3A7/12/214T24642129CJ57/12/215T24642130CJ5A7/12/216T24642131EJ77/12/217T24642132HJ57/12/218T24642133HJ77/12/219T24642134T017/12/2110T24642135T027/12/2111T24642136T037/12/2112T24642137T047/12/2113T24642138T057/12/2114T24642139T067/12/21 No.Seal#Truss Name 15 T24642140 T07 Date 7/12/2116T24642141T087/12/2117T24642142T097/12/2118T24642143T107/12/2119T24642144T117/12/2120T24642145T127/12/2121T24642146T137/12/2122T24642147T147/12/2123T24642148T14A7/12/2124T24642149T157/12/2125T24642150T167/12/2126T24642151T177/12/2127T24642152T187/12/2128T24642153T197/12/21 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies 6904 Parke East Blvd. Tampa, FL 33610-4115 MiTek USA, Inc. RE: WS0031 - 2 of 2 Site Information: Lot/Block: 31 Customer Info: K Hovnanian Homes Project Name: WS0031 Model: Lelia-A Subdivision: Waterstone Address: 5109 Armina Pl., . State: FLCity: Fort Pierce No.Seal#Truss Name 29 T24642154 T20 Date 7/12/2130T24642155V017/12/2131T24642156V027/12/2132T24642157V037/12/2133T24642158V047/12/21 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss CJ1 Truss Type CORNER JACK Qty 12 Ply 1 Job Reference (optional) T24642126 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:28 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-o_fa6TEu21cZpZ1kqlVwHhqEWZBlwfaaXWqZHJyyu41 Scale = 1:6.5 1 2 3 4 2x4 ST1.5x8 STP 1-0-0 1-0-0 -1-0-0 1-0-0 1-0-0 1-0-0 0-4-10-9-10-4-100-9-15.00 12 Plate Offsets (X,Y)-- [2:0-1-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.15 0.01 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 2 2 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=40(LC 12) Max Uplift 3=-8(LC 1), 2=-97(LC 12) Max Grav 3=18(LC 12), 2=125(LC 1), 4=18(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 8 lb uplift at joint 3 and 97 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss CJ3 Truss Type Corner Jack Qty 11 Ply 1 Job Reference (optional) T24642127 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:29 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-GADzKpFWpLkQRjcwOT09quMO3zVCf6qjmAa7qlyyu40 Scale = 1:10.8 1 2 5 3 4 2x4 ST1.5x8 STP 3-0-0 3-0-0 -1-0-0 1-0-0 3-0-0 3-0-0 0-4-11-7-11-2-101-7-15.00 12 Plate Offsets (X,Y)-- [2:0-1-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.23 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=71(LC 12) Max Uplift 3=-32(LC 12), 2=-106(LC 12) Max Grav 3=54(LC 17), 2=187(LC 1), 4=52(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 32 lb uplift at joint 3 and 106 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss CJ3A Truss Type Corner Jack Qty 1 Ply 1 Job Reference (optional) T24642128 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:29 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-GADzKpFWpLkQRjcwOT09quMN3zVkf6qjmAa7qlyyu40 Scale = 1:10.8 1 2 3 2x4 3-0-0 3-0-0 3-0-0 3-0-0 0-4-11-7-11-2-101-7-15.00 12 Plate Offsets (X,Y)-- [1:0-0-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.30 0.16 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 1-3 1-3 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=Mechanical, 2=Mechanical, 3=Mechanical Max Horz 1=49(LC 12) Max Uplift 1=-24(LC 12), 2=-54(LC 12) Max Grav 1=106(LC 1), 2=78(LC 1), 3=58(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 24 lb uplift at joint 1 and 54 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss CJ5 Truss Type Corner Jack Qty 9 Ply 1 Job Reference (optional) T24642129 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:30 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-kMnLX9G8aesH3tB7yAXOM6vVPNpNOZ4t?pJgMCyyu4? Scale = 1:15.8 1 2 5 6 3 4 2x4 ST1.5x8 STP 5-0-0 5-0-0 -1-0-0 1-0-0 5-0-0 5-0-0 0-4-12-5-12-0-102-5-15.00 12 Plate Offsets (X,Y)-- [2:0-1-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.45 0.26 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.05 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=103(LC 12) Max Uplift 3=-77(LC 12), 2=-116(LC 12) Max Grav 3=114(LC 17), 2=253(LC 1), 4=92(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 77 lb uplift at joint 3 and 116 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss CJ5A Truss Type Corner Jack Qty 1 Ply 1 Job Reference (optional) T24642130 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:31 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-CZKjlVHmLy_8g1mJWu2dvJSfgm9470K0DT3Eueyyu4_ Scale = 1:14.9 1 4 5 2 3 2x4 5-0-0 5-0-0 5-0-0 5-0-0 0-4-12-5-12-0-102-5-15.00 12 Plate Offsets (X,Y)-- [1:0-0-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.54 0.29 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.07 -0.00 (loc) 1-3 1-3 2 l/defl >999 >863 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=Mechanical, 2=Mechanical, 3=Mechanical Max Horz 1=81(LC 12) Max Uplift 1=-42(LC 12), 2=-91(LC 12) Max Grav 1=180(LC 1), 2=132(LC 1), 3=98(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-0-12 to 3-0-12, Interior(1) 3-0-12 to 4-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 42 lb uplift at joint 1 and 91 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss EJ7 Truss Type Jack-Open Qty 19 Ply 1 Job Reference (optional) T24642131 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:31 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-CZKjlVHmLy_8g1mJWu2dvJSdem6A70K0DT3Eueyyu4_ Scale = 1:19.8 1 2 5 6 3 43x4 ST1.5x8 STP 7-0-0 7-0-0 -1-0-0 1-0-0 7-0-0 7-0-0 0-4-13-3-12-10-103-3-15.00 12 Plate Offsets (X,Y)-- [2:0-0-10,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.67 0.48 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.10 -0.18 -0.00 (loc) 2-4 2-4 3 l/defl >773 >431 n/a L/d 240 180 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=136(LC 12) Max Uplift 3=-103(LC 12), 2=-130(LC 12) Max Grav 3=159(LC 1), 2=324(LC 1), 4=121(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 103 lb uplift at joint 3 and 130 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss HJ5 Truss Type Roof Special Girder Qty 1 Ply 1 Job Reference (optional) T24642132 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:32 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-glu5yqIP6G6?IBLV3bZsRX_ohARrsSy9S7onQ4yyu3z Scale = 1:16.2 1 2 3 4 6 52x4 2x4 2x4 2x4 6-9-6 6-9-6 7-0-14 0-3-8 -1-5-0 1-5-0 6-9-6 6-9-6 7-0-14 0-3-8 0-3-132-4-133.54 12 Plate Offsets (X,Y)-- [2:0-0-14,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.65 0.52 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.18 0.00 (loc) 2-6 2-6 l/defl >910 >443 n/a L/d 240 180 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=1-5-0, 6=0-5-5 Max Horz 2=94(LC 8) Max Uplift 2=-106(LC 8), 6=-112(LC 8) Max Grav 2=225(LC 1), 6=302(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 106 lb uplift at joint 2 and 112 lb uplift at joint 6. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54 Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-to-3=-92(F=-19, B=-19), 3=-52(F=-19, B=-19)-to-4=-55(F=-21, B=-21), 2=0(F=10, B=10)-to-5=-35(F=-8, B=-8) This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss HJ7 Truss Type Diagonal Hip Girder Qty 5 Ply 1 Job Reference (optional) T24642133 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:33 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-8xSTAAI1tZEswKwidJ45_kX13apFbr7JhnYKyWyyu3y Scale = 1:20.6 1 2 3 7 6 8 4 52x4 3x4 3x4 2x4 5-8-1 5-8-1 9-10-1 4-1-15 -1-5-0 1-5-0 5-8-1 5-8-1 9-10-1 4-1-15 0-4-13-2-133.54 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.42 0.44 0.30 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.06 0.01 (loc) 2-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 40 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 2=0-10-15, 5=Mechanical Max Horz 2=162(LC 8) Max Uplift 4=-131(LC 8), 2=-155(LC 8), 5=-91(LC 8) Max Grav 4=211(LC 13), 2=392(LC 1), 5=375(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-777/150 BOT CHORD 2-7=-265/722, 6-7=-265/722 WEBS 3-6=-790/289, 3-7=0/272 NOTES-(8) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 4, 155 lb uplift at joint 2 and 91 lb uplift at joint 5. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-8=-54 Trapezoidal Loads (plf) Vert: 8=0(F=27, B=27)-to-4=-133(F=-39, B=-39), 2=-2(F=9, B=9)-to-5=-49(F=-15, B=-15) This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T01 Truss Type Hip Girder Qty 1 Ply 1 Job Reference (optional) T24642134 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:34 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-d80sNWJfetMjXUVuB0bKXy47W_0bKI0SwRHuUzyyu3x Scale: 3/8"=1' 1 2 3 4 5 7 6 8 3x6 ST1.5x8 STP 5x6 5x6 3x4 5x6 4x4 7-0-0 7-0-0 11-8-0 4-8-0 18-8-0 7-0-0 7-0-0 7-0-0 11-8-0 4-8-0 18-8-0 7-0-0 19-8-0 1-0-0 0-4-13-3-10-4-13-3-15.00 12 Plate Offsets (X,Y)-- [1:0-0-14,0-0-2], [2:0-3-0,0-2-4], [3:0-3-0,0-2-4], [4:0-2-6,Edge], [7:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.76 0.95 0.26 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.23 0.09 (loc) 6-7 6-7 4 l/defl >999 >943 n/a L/d 240 180 n/a PLATES MT20 Weight: 75 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 31 *Except* 2-3: 2x4 SP No.1 BOT CHORD 2x4 SP No.1 *Except* 4-7: 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-1-15 oc bracing. REACTIONS. (size)1=Mechanical, 4=0-8-0 Max Horz 1=-79(LC 6) Max Uplift 1=-495(LC 8), 4=-576(LC 8) Max Grav 1=1519(LC 1), 4=1621(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3390/1094, 2-3=-2971/1021, 3-4=-3355/1077 BOT CHORD 1-7=-914/3054, 6-7=-907/3019, 4-6=-892/3003 WEBS 2-7=-139/629, 3-6=-144/681 NOTES-(11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 495 lb uplift at joint 1 and 576 lb uplift at joint 4. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 199 lb down and 68 lb up at 7-0-0, and 199 lb down and 68 lb up at 11-8-0 on top chord, and 375 lb down and 128 lb up at 7-0-0, and 375 lb down and 128 lb up at 11-8-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard Continued on page 2 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T01 Truss Type Hip Girder Qty 1 Ply 1 Job Reference (optional) T24642134 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:34 2021 Page 2 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-d80sNWJfetMjXUVuB0bKXy47W_0bKI0SwRHuUzyyu3x LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54, 2-3=-134(F=-80), 3-5=-54, 1-7=-20, 6-7=-59(F=-39), 4-6=-20 Concentrated Loads (lb) Vert: 3=-199(F) 7=-375(F) 6=-375(F) 2=-199(F) Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T02 Truss Type Jack-Open Girder Qty 1 Ply 1 Job Reference (optional) T24642135 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:35 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-5KaEasKHPBUa9e44lj7Z39cI3OOh3o2c851R0Pyyu3w Scale = 1:20.0 1 2 3 5 467 3x4 ST1.5x8 STP 2x4 2x4 2x4 2x4 5-0-12 5-0-12 7-0-0 1-11-4 5-0-12 5-0-12 7-0-0 1-11-4 0-4-13-3-15.00 12 Plate Offsets (X,Y)-- [1:0-4-5,0-1-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.71 0.83 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.18 -0.32 0.00 (loc) 1-5 1-5 l/defl >439 >242 n/a L/d 240 180 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x6 SP M 26 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-8-7 oc bracing. REACTIONS. (size)1=0-8-0, 4=Mechanical Max Horz 1=108(LC 8) Max Uplift 1=-248(LC 8), 4=-489(LC 8) Max Grav 1=822(LC 1), 4=1406(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-217/273 NOTES-(9) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 248 lb uplift at joint 1 and 489 lb uplift at joint 4. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 86 lb down and 44 lb up at 1-1-1, and 160 lb down and 62 lb up at 3-1-1, and 1499 lb down and 515 lb up at 5-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 1-4=-20 Concentrated Loads (lb) Vert: 5=-1499(F) 6=-86(F) 7=-160(F) This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T03 Truss Type Roof Special Girder Qty 1 Ply 1 Job Reference (optional) T24642136 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:36 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-ZW8coCLvAUcQnofGIReocN9Wanjoo3WlNlm_Zryyu3v Scale = 1:57.1 1 2 3 4 5 6 7 8 9 10 15 14 13 12 11 16 17 18 19 5x6 ST1.5x8 STP ST1.5x8 STP 4x6 4x4 3x10 8x12 4x4 2x4 4x8 2x4 3x8 2x4 3x8 7-0-0 7-0-0 11-11-14 4-11-14 15-4-13 3-5-0 18-8-0 3-3-3 20-8-0 2-0-0 21-0-0 0-4-0 21-4-0 0-4-0 30-4-0 9-0-0 -1-0-0 1-0-0 4-3-7 4-3-7 7-0-0 2-8-9 11-11-14 4-11-14 15-4-13 3-5-0 18-8-0 3-3-3 20-8-0 2-0-0 21-0-0 0-4-0 21-4-0 0-4-0 24-5-13 3-1-13 30-4-0 5-10-3 31-4-0 1-0-0 0-4-13-3-14-1-10-4-13-3-15.00 12 Plate Offsets (X,Y)-- [2:0-3-1,0-1-8], [3:0-3-0,0-2-4], [9:0-3-1,0-1-8], [12:0-2-12,0-5-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.53 0.84 0.84 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.27 -0.49 0.11 (loc) 13 13 9 l/defl >999 >719 n/a L/d 240 180 n/a PLATES MT20 Weight: 169 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 31 *Except* 6-7,7-10: 2x4 SP No.2 BOT CHORD 2x6 SP M 26 *Except* 9-12: 2x6 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-4-14 oc bracing. REACTIONS. (size)2=0-8-0, 9=0-8-0 Max Horz 2=103(LC 7) Max Uplift 2=-773(LC 8), 9=-571(LC 8) Max Grav 2=2227(LC 1), 9=1611(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4930/1590, 3-4=-4522/1518, 4-5=-5010/1682, 5-6=-5010/1682, 6-7=-3093/1038, 7-8=-3125/1036, 8-9=-3367/1120 BOT CHORD 2-15=-1362/4459, 14-15=-1712/5518, 13-14=-1712/5518, 11-13=-1336/4375, 9-11=-943/3035 WEBS 3-15=-331/1228, 6-13=-276/930, 6-11=-2424/849, 4-13=-745/280, 7-11=-703/2194, 4-14=-132/555, 4-15=-1160/388 NOTES-(10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 773 lb uplift at joint 2 and 571 lb uplift at joint 9. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 199 lb down and 65 lb up at 7-0-0 on top chord, and 375 lb down and 123 lb up at 7-0-0, and 375 lb down and 123 lb up at 11-8-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard Continued on page 2 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T03 Truss Type Roof Special Girder Qty 1 Ply 1 Job Reference (optional) T24642136 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:36 2021 Page 2 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-ZW8coCLvAUcQnofGIReocN9Wanjoo3WlNlm_Zryyu3v LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-16=-134(F=-80), 6-16=-54, 6-7=-54, 7-10=-54, 2-15=-20, 15-19=-59(F=-39), 9-19=-20 Concentrated Loads (lb) Vert: 3=-199(F) 15=-375(F) 19=-375(F) Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T04 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T24642137 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:37 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-1ji_?YLXxokHOyDTs8918aijhB33XgbucPWY5Iyyu3u Scale = 1:55.0 1 2 3 4 5 6 7 8 9 12 11 10 13 14 15 16 17 18 19 20 4x8 ST1.5x8 STP ST1.5x8 STP 4x8 4x4 3x4 2x4 5x8 2x4 4x4 3x4 2x4 9-0-0 9-0-0 15-2-0 6-2-0 20-8-0 5-6-0 21-4-0 0-8-0 30-4-0 9-0-0 -1-0-0 1-0-0 5-8-11 5-8-11 9-0-0 3-3-5 15-2-0 6-2-0 20-8-0 5-6-0 21-0-0 0-4-0 21-4-0 0-4-0 24-7-6 3-3-6 30-4-0 5-8-10 31-4-0 1-0-0 0-4-14-1-10-4-14-1-15.00 12 Plate Offsets (X,Y)-- [4:0-5-4,0-2-0], [6:0-5-4,0-2-0], [7:0-0-0,0-0-0], [11:0-4-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.45 0.83 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.38 0.09 (loc) 2-12 2-12 8 l/defl >999 >948 n/a L/d 240 180 n/a PLATES MT20 Weight: 144 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-7-14 oc bracing. REACTIONS. (size)2=0-8-0, 8=0-8-0 Max Horz 2=100(LC 11) Max Uplift 2=-427(LC 12), 8=-427(LC 12) Max Grav 2=1170(LC 1), 8=1170(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2221/925, 3-4=-1995/830, 4-5=-2192/960, 5-6=-2192/960, 6-7=-1995/830, 7-8=-2221/925 BOT CHORD 2-12=-770/1990, 11-12=-611/1814, 10-11=-615/1814, 8-10=-775/1990 WEBS 4-12=-63/378, 4-11=-202/542, 5-11=-380/235, 6-11=-202/542, 6-10=-63/377 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0, Interior(1) 12-0-0 to 21-4-0, Exterior(2R) 21-4-0 to 24-4-0, Interior(1) 24-4-0 to 31-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 427 lb uplift at joint 2 and 427 lb uplift at joint 8. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T05 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T24642138 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:38 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-VvGMDuM9i6s806ofQsgGhoEssbSRG742q3F5dkyyu3t Scale = 1:54.8 1 2 3 4 5 6 7 8 13 12 11 10 9 14 15 16 3x4 ST1.5x8 STP ST1.5x8 STP 4x4 4x4 4x6 3x4 2x4 3x8 3x4 3x8 3x4 2x4 3x4 6-6-5 6-6-5 11-0-0 4-5-11 19-4-0 8-4-0 23-9-11 4-5-11 30-4-0 6-6-5 6-6-5 6-6-5 11-0-0 4-5-11 15-2-0 4-2-0 19-4-0 4-2-0 23-9-11 4-5-11 30-4-0 6-6-5 31-4-0 1-0-0 0-4-14-11-10-4-14-11-15.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [7:0-3-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.55 0.70 0.26 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.15 -0.36 0.09 (loc) 10-12 10-12 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 147 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-9-5 oc bracing. REACTIONS. (size)1=0-8-0, 7=0-8-0 Max Horz 1=-119(LC 10) Max Uplift 1=-357(LC 12), 7=-428(LC 12) Max Grav 1=1096(LC 1), 7=1171(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2277/886, 2-3=-1829/764, 3-4=-1650/736, 4-5=-1648/741, 5-6=-1826/763, 6-7=-2262/885 BOT CHORD 1-13=-725/2024, 12-13=-725/2024, 10-12=-594/1755, 9-10=-733/2009, 7-9=-733/2009 WEBS 2-12=-461/252, 3-12=-163/486, 4-12=-267/113, 4-10=-269/117, 5-10=-160/484, 6-10=-446/244 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 11-0-0, Exterior(2R) 11-0-0 to 15-2-0, Interior(1) 15-2-0 to 19-4-0, Exterior(2R) 19-4-0 to 23-9-11, Interior(1) 23-9-11 to 31-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 357 lb uplift at joint 1 and 428 lb uplift at joint 7. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T06 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T24642139 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:39 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-z5plQENoTP_?eFNr_ZBVE?n_v?mI?WyB3j?f9Ayyu3s Scale = 1:54.8 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 17 18 3x4 ST1.5x8 STP ST1.5x8 STP 4x8 4x4 3x6 3x4 2x4 3x4 3x8 3x4 2x4 3x4 7-7-12 7-7-12 13-0-0 5-4-4 17-4-0 4-4-0 22-8-4 5-4-4 30-4-0 7-7-12 7-7-12 7-7-12 13-0-0 5-4-4 17-4-0 4-4-0 22-8-4 5-4-4 30-4-0 7-7-12 31-4-0 1-0-0 0-4-15-9-10-4-15-9-15.00 12 Plate Offsets (X,Y)-- [1:0-1-10,Edge], [3:0-5-4,0-2-0], [6:0-3-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.72 0.78 0.47 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.27 0.09 (loc) 9-11 1-12 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 147 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-9-6 oc bracing. REACTIONS. (size)1=0-8-0, 6=0-8-0 Max Horz 1=-139(LC 10) Max Uplift 1=-357(LC 12), 6=-428(LC 12) Max Grav 1=1096(LC 1), 6=1171(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2235/865, 2-3=-1651/721, 3-4=-1470/708, 4-5=-1651/724, 5-6=-2223/866 BOT CHORD 1-12=-697/1980, 11-12=-697/1980, 9-11=-450/1470, 8-9=-707/1967, 6-8=-707/1967 WEBS 2-12=0/292, 2-11=-610/294, 3-11=-117/390, 4-9=-121/390, 5-9=-596/286, 5-8=0/290 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 13-0-0, Exterior(2E) 13-0-0 to 17-4-0, Exterior(2R) 17-4-0 to 21-6-15, Interior(1) 21-6-15 to 31-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 357 lb uplift at joint 1 and 428 lb uplift at joint 6. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T07 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T24642140 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:40 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-RHN7eZOQEj6sGPy2XHikmDK5IP4jkvbLINkCicyyu3r Scale = 1:53.8 1 2 3 4 5 6 7 8 11 10 9 12 13 14 15 3x6 ST1.5x8 STP ST1.5x8 STP 4x4 3x6 4x4 3x4 2x4 5x8 3x4 2x4 4x4 8-9-6 8-9-6 15-0-0 6-2-10 15-2-0 0-2-0 15-4-0 0-2-0 21-6-10 6-2-10 30-4-0 8-9-6 8-9-6 8-9-6 15-0-0 6-2-10 15-2-0 0-2-0 15-4-0 0-2-0 21-6-10 6-2-10 30-4-0 8-9-6 31-4-0 1-0-0 0-4-16-7-140-4-15.00 12 Plate Offsets (X,Y)-- [10:0-4-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 1.00 0.90 0.77 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.18 -0.38 0.09 (loc) 1-11 1-11 7 l/defl >999 >931 n/a L/d 240 180 n/a PLATES MT20 Weight: 136 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-11-6 oc bracing. REACTIONS. (size)1=0-8-0, 7=0-8-0 Max Horz 1=-160(LC 10) Max Uplift 1=-357(LC 12), 7=-428(LC 12) Max Grav 1=1096(LC 1), 7=1171(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2179/808, 2-4=-1482/632, 4-6=-1481/626, 6-7=-2170/798 BOT CHORD 1-11=-631/1922, 10-11=-631/1922, 9-10=-635/1912, 7-9=-635/1912 WEBS 2-11=0/338, 2-10=-742/350, 6-10=-731/345, 6-9=0/337, 4-10=-296/812 NOTES-(7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 15-2-0, Exterior(2R) 15-2-0 to 19-4-15, Interior(1) 19-4-15 to 31-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 357 lb uplift at joint 1 and 428 lb uplift at joint 7. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T08 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T24642141 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:41 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-vUxVrvP2?1FjtZXE5_DzJQsLFoTCTIhUX1UlE3yyu3q Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 23 24 25 5x12 ST1.5x8 STP ST1.5x8 STP ST1.5x8 STP 4x4 4x6 3x6 3x4 3x6 2x4 5x12 3x4 3x4 5x6 3x4 3x4 2x4 5-0-0 5-0-0 9-8-0 4-8-0 16-3-11 6-7-11 23-4-5 7-0-11 29-9-13 6-5-8 35-0-0 5-2-3 -1-0-0 1-0-0 5-0-0 5-0-0 9-8-0 4-8-0 12-2-8 2-6-9 19-10-0 7-7-8 27-5-8 7-7-8 35-0-0 7-6-8 36-0-0 1-0-0 0-4-12-5-16-7-140-4-12-5-15.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge], [3:0-10-4,0-2-12], [9:0-3-0,0-1-8], [12:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.67 0.69 0.97 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.29 0.04 (loc) 12-13 12-13 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 171 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-9-4 oc bracing. REACTIONS. (size)2=0-8-0, 16=0-8-0, 9=0-8-0 Max Horz 2=-162(LC 10) Max Uplift 2=-376(LC 18), 16=-606(LC 12), 9=-398(LC 12) Max Grav 2=38(LC 12), 16=2138(LC 17), 9=1196(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-463/1478, 3-4=-919/374, 4-5=-1020/426, 5-6=-1517/598, 6-8=-1689/645, 8-9=-2341/754 BOT CHORD 2-16=-1294/491, 15-16=-1417/543, 13-15=-440/1435, 12-13=-285/1195, 11-12=-624/1907, 9-11=-609/2080 WEBS 3-16=-1936/752, 3-15=-883/2565, 4-15=-478/231, 5-15=-644/287, 6-13=-70/387, 6-12=-174/707, 8-12=-575/321, 8-11=0/304 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-0-0, Exterior(2R) 5-0-0 to 8-0-0, Interior(1) 8-0-0 to 19-10-0, Exterior(2R) 19-10-0 to 22-10-0, Interior(1) 22-10-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 376 lb uplift at joint 2, 606 lb uplift at joint 16 and 398 lb uplift at joint 9. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T09 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T24642142 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:42 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-OgVt3FPglKNaVj6QfilCrdPTYCosCqVelhDJmVyyu3p Scale = 1:64.8 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 17 18 19 20 21 22 5x6 ST1.5x8 STP ST1.5x8 STP ST1.5x8 STP 5x6 4x6 3x6 3x4 5x8 3x4 4x4 3x4 5x6 3x4 2x4 5-0-0 5-0-0 7-0-0 2-0-0 11-8-0 4-8-0 16-3-11 4-7-11 19-10-0 3-6-5 23-4-5 3-6-5 29-9-12 6-5-7 35-0-0 5-2-4 -1-0-0 1-0-0 7-0-0 7-0-0 11-8-0 4-8-0 12-2-10 0-6-10 16-3-11 4-1-1 19-10-0 3-6-5 27-5-7 7-7-7 29-9-12 2-4-5 35-0-0 5-2-4 36-0-0 1-0-0 0-4-13-3-16-7-140-4-13-3-15.00 12 Plate Offsets (X,Y)-- [2:0-1-2,Edge], [3:0-3-0,0-2-4], [11:0-3-0,0-3-0], [13:0-2-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.89 0.73 0.68 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.18 -0.31 0.05 (loc) 11-12 11-12 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 170 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 *Except* 4-5: 2x4 SP No.1 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-0-9 oc bracing. REACTIONS. (size)2=0-8-0, 14=0-8-0, 8=0-8-0 Max Horz 2=-162(LC 10) Max Uplift 2=-310(LC 18), 14=-557(LC 12), 8=-409(LC 12) Max Grav 2=7(LC 9), 14=2032(LC 17), 8=1226(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-440/1383, 3-4=-1561/667, 4-5=-1610/643, 5-7=-1769/683, 7-8=-2413/792 BOT CHORD 2-14=-1202/485, 12-13=-516/1630, 11-12=-326/1263, 10-11=-657/1975, 8-10=-644/2145 WEBS 3-14=-2138/848, 4-13=-794/367, 5-12=-79/412, 4-12=-303/181, 5-11=-168/713, 7-11=-567/315, 7-10=0/298, 3-13=-601/1791 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-0-0, Exterior(2R) 7-0-0 to 10-0-0, Interior(1) 10-0-0 to 19-10-0, Exterior(2R) 19-10-0 to 22-10-0, Interior(1) 22-10-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 310 lb uplift at joint 2, 557 lb uplift at joint 14 and 409 lb uplift at joint 8. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T10 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T24642143 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:44 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-K3ddTxRwHydIk1Gpm6ngx2Uo70TmgiIwD?iQrOyyu3n Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 23 24 4x4 ST1.5x8 STP ST1.5x8 STP ST1.5x8 STP 4x6 4x4 3x6 3x4 3x6 4x8 3x6 4x4 5x6 3x4 2x4 3x4 2x4 5-0-0 5-0-0 9-0-0 4-0-0 13-8-0 4-8-0 16-3-11 2-7-11 19-10-0 3-6-5 23-4-5 3-6-5 27-1-2 3-8-13 29-4-11 2-3-9 35-0-0 5-7-5 -1-0-0 1-0-0 5-5-0 5-5-0 9-0-0 3-7-0 13-8-0 4-8-0 19-10-0 6-2-0 26-0-0 6-2-0 27-1-2 1-1-2 35-0-0 7-10-14 36-0-0 1-0-0 0-4-14-1-16-7-140-4-14-1-15.00 12 Plate Offsets (X,Y)-- [9:0-2-6,Edge], [12:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.88 0.83 0.78 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.29 0.05 (loc) 12-13 12-13 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 176 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-6-14 oc bracing. REACTIONS. (size)2=0-8-0, 9=0-8-0, 16=0-8-0 Max Horz 2=-162(LC 10) Max Uplift 2=-275(LC 18), 9=-407(LC 12), 16=-566(LC 12) Max Grav 2=15(LC 9), 9=1230(LC 18), 16=2006(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-405/1244, 3-4=-721/333, 4-5=-633/326, 5-6=-1627/677, 6-8=-1800/723, 8-9=-2368/770 BOT CHORD 2-16=-1095/432, 15-16=-762/294, 13-15=-490/1573, 12-13=-316/1246, 11-12=-603/1858, 9-11=-606/2089 WEBS 3-15=-513/1564, 6-12=-232/777, 8-12=-524/304, 8-11=-5/338, 6-13=-135/492, 5-13=-252/195, 5-15=-1168/454, 3-16=-1858/723 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0, Interior(1) 12-0-0 to 19-10-0, Exterior(2R) 19-10-0 to 22-10-0, Interior(1) 22-10-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 275 lb uplift at joint 2, 407 lb uplift at joint 9 and 566 lb uplift at joint 16. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T11 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T24642144 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:45 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-oFB0hHSY2Fl9MAr?KqIvTG1z?Qp3PEW4RfSzNqyyu3m Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 16 1514 13 12 11 17 18 19 20 21 22 23 24 4x8 ST1.5x8 STP ST1.5x8 STP ST1.5x8 STP 4x4 4x4 3x6 3x4 3x6 2x4 3x8 3x4 3x8 5x6 3x4 4x4 2x4 5-0-0 5-0-0 11-0-0 6-0-0 15-8-0 4-8-0 23-4-5 7-8-5 29-4-11 6-0-6 35-0-0 5-7-5 -1-0-0 1-0-0 6-8-2 6-8-2 11-0-0 4-3-14 15-8-0 4-8-0 19-10-0 4-2-0 26-0-0 6-2-0 35-0-0 9-0-0 36-0-0 1-0-0 0-4-14-11-16-7-140-4-14-11-15.00 12 Plate Offsets (X,Y)-- [4:0-5-4,0-2-0], [9:0-2-6,Edge], [12:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.87 0.83 0.47 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.38 0.05 (loc) 12-13 12-13 9 l/defl >999 >951 n/a L/d 240 180 n/a PLATES MT20 Weight: 181 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-7-15 oc bracing. REACTIONS. (size)2=0-8-0, 16=0-8-0, 9=0-8-0 Max Horz 2=-162(LC 10) Max Uplift 2=-239(LC 24), 16=-542(LC 12), 9=-411(LC 12) Max Grav 2=5(LC 9), 16=1951(LC 17), 9=1246(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-392/1161, 3-4=-1070/479, 4-5=-1548/671, 5-6=-1739/784, 6-8=-1849/742, 8-9=-2400/791 BOT CHORD 2-16=-1009/421, 13-15=-251/995, 12-13=-332/1259, 11-12=-622/1900, 9-11=-626/2119 WEBS 3-16=-1952/794, 3-15=-326/1122, 4-15=-421/198, 4-13=-300/901, 5-13=-848/450, 6-13=-255/613, 6-12=-232/814, 8-12=-519/309, 8-11=-6/320 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 11-0-0, Exterior(2R) 11-0-0 to 14-0-0, Interior(1) 14-0-0 to 19-10-0, Exterior(2R) 19-10-0 to 22-10-0, Interior(1) 22-10-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 239 lb uplift at joint 2, 542 lb uplift at joint 16 and 411 lb uplift at joint 9. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T12 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T24642145 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:46 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-GRkOudSBpZt0_KQBuXp80TZ8fp888c_DgJBWvGyyu3l Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 23 24 4x4 ST1.5x8 STP ST1.5x8 STP ST1.5x8 STP 4x12 4x4 3x6 3x4 3x6 3x4 3x4 3x8 3x4 5x6 3x4 4x4 2x4 5-0-0 5-0-0 13-0-0 8-0-0 17-8-0 4-8-0 23-4-5 5-8-5 29-4-11 6-0-6 35-0-0 5-7-5 -1-0-0 1-0-0 7-9-7 7-9-7 13-0-0 5-2-9 17-8-0 4-8-0 19-10-0 2-2-0 26-0-0 6-2-0 35-0-0 9-0-0 36-0-0 1-0-0 0-4-15-9-16-7-140-4-15-9-15.00 12 Plate Offsets (X,Y)-- [2:0-0-14,Edge], [9:0-2-6,Edge], [12:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.88 0.84 0.77 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.14 -0.24 0.06 (loc) 12-13 12-13 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 186 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)2=0-8-0, 16=0-8-0, 9=0-8-0 Max Horz 2=162(LC 11) Max Uplift 2=-177(LC 24), 16=-498(LC 12), 9=-417(LC 12) Max Grav 2=17(LC 21), 16=1832(LC 17), 9=1259(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-311/952, 3-4=-1278/566, 4-5=-1137/551, 5-6=-1620/766, 6-8=-1868/771, 8-9=-2444/817 BOT CHORD 2-16=-824/364, 14-16=-213/647, 13-14=-432/1485, 12-13=-356/1292, 11-12=-647/1923, 9-11=-650/2158 WEBS 3-16=-2026/831, 3-14=-128/726, 4-14=-43/288, 5-14=-571/207, 5-13=-420/263, 6-13=-260/596, 6-12=-236/762, 8-12=-529/308, 8-11=-4/345 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 13-0-0, Exterior(2R) 13-0-0 to 16-0-0, Interior(1) 16-0-0 to 19-10-0, Exterior(2R) 19-10-0 to 22-10-0, Interior(1) 22-10-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 177 lb uplift at joint 2, 498 lb uplift at joint 16 and 417 lb uplift at joint 9. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T13 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T24642146 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:47 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-keIm6zTpat?tbU_OSFKNYh6KeDU9tBqNvzx4Riyyu3k Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 3x6 ST1.5x8 STP ST1.5x8 STP 4x8 4x6 3x6 4x4 4x6 3x4 2x4 3x4 3x4 2x4 4x6 4x4 3x8 7-4-11 7-4-11 15-0-0 7-7-5 19-8-0 4-8-0 20-0-0 0-4-0 27-7-6 7-7-6 35-0-0 7-4-10 -1-0-0 1-0-0 7-4-11 7-4-11 15-0-0 7-7-5 19-8-0 4-8-0 19-10-0 0-2-0 20-0-0 0-2-0 27-7-6 7-7-6 35-0-0 7-4-10 36-0-0 1-0-0 0-4-16-7-10-4-16-7-15.00 12 Plate Offsets (X,Y)-- [5:0-5-4,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.80 0.79 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.37 0.13 (loc) 14 14-16 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-2-4 oc bracing. WEBS 1 Row at midpt 3-14, 8-13 REACTIONS. (size)2=0-8-0, 9=0-8-0 Max Horz 2=-160(LC 10) Max Uplift 2=-483(LC 12), 9=-483(LC 12) Max Grav 2=1342(LC 1), 9=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2686/1052, 3-5=-1940/845, 5-6=-1719/842, 6-8=-1941/845, 8-9=-2686/1052 BOT CHORD 2-16=-880/2398, 14-16=-880/2398, 13-14=-553/1718, 11-13=-884/2398, 9-11=-884/2398 WEBS 3-16=0/327, 3-14=-751/354, 5-14=-95/441, 8-11=0/327, 6-13=-104/442, 8-13=-751/354 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 15-0-0, Exterior(2R) 15-0-0 to 18-0-0, Interior(1) 18-0-0 to 20-0-0, Exterior(2R) 20-0-0 to 23-0-0, Interior(1) 23-0-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 9. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T14 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T24642147 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:48 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-Cqs8JJURLA7jDeZa?yrc5ufaCdrCcYYW8dgd_9yyu3j Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 11 12 13 18 17 16 15 14 19 20 21 22 23 24 3x6 ST1.5x8 STP ST1.5x8 STP 3x6 3x6 3x6 4x4 4x6 3x4 2x4 3x4 3x8 3x4 3x4 2x4 4x6 4x4 3x6 8-9-9 8-9-9 17-0-0 8-2-7 17-6-0 0-6-0 18-0-0 0-6-0 26-2-7 8-2-7 35-0-0 8-9-9 -1-0-0 1-0-0 6-1-3 6-1-3 12-3-13 6-2-10 17-0-0 4-8-3 17-6-0 0-6-0 18-0-0 0-6-0 22-8-3 4-8-3 28-10-13 6-2-10 35-0-0 6-1-3 36-0-0 1-0-0 0-4-17-5-10-4-17-5-15.00 12 Plate Offsets (X,Y)-- [6:0-3-0,0-2-4], [8:0-3-0,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.49 0.73 0.70 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.26 -0.45 0.12 (loc) 14-16 14-16 12 l/defl >999 >909 n/a L/d 240 180 n/a PLATES MT20 Weight: 171 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-10-2 oc bracing. REACTIONS. (size)2=0-8-0, 12=0-8-0 Max Horz 2=-180(LC 10) Max Uplift 2=-483(LC 12), 12=-483(LC 12) Max Grav 2=1492(LC 17), 12=1492(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2945/999, 3-5=-2734/929, 5-6=-1883/734, 6-7=-1696/704, 7-8=-1696/704, 8-9=-1883/734, 9-11=-2735/929, 11-12=-2946/999 BOT CHORD 2-18=-832/2789, 16-18=-608/2218, 14-16=-618/2123, 12-14=-842/2654 WEBS 3-18=-297/215, 5-18=-113/637, 5-16=-689/320, 9-16=-689/320, 9-14=-113/637, 11-14=-297/215, 7-16=-381/1191 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 17-0-0, Exterior(2E) 17-0-0 to 18-0-0, Exterior(2R) 18-0-0 to 22-2-15, Interior(1) 22-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 12. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T14A Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T24642148 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:50 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-9D_vk_VhtoNRSyjz7Nu4AJkuHRWi4Onpbx9k21yyu3h Scale = 1:66.0 1 2 3 4 5 6 7 8 9 10 11 12 13 15 14 18 17 16 21 20 19 22 23 24 25 3x6 ST1.5x8 STP ST1.5x8 STP 4x4 4x4 3x6 3x4 2x4 3x8 2x4 4x12 2x4 2x4 4x4 3x4 5x6 5x8 3x4 5x8 3x4 4x4 7-2-10 7-2-10 11-3-4 4-0-10 17-0-0 5-8-12 20-8-0 3-8-0 27-1-12 6-5-12 35-0-0 7-10-4 -1-0-0 1-0-0 4-10-13 4-10-13 11-3-4 6-4-7 17-0-0 5-8-12 18-0-0 1-0-0 20-8-0 2-8-0 23-5-6 2-9-6 27-1-12 3-8-5 29-1-10 1-11-14 35-0-0 5-10-6 36-0-0 1-0-0 0-4-17-5-10-4-12-0-07-5-15.00 12 Plate Offsets (X,Y)-- [14:0-5-0,0-2-0], [16:0-5-8,0-3-8], [18:0-5-8,0-3-4], [20:0-2-12,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.58 0.80 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.23 -0.45 0.19 (loc) 18 19-20 12 l/defl >999 >925 n/a L/d 240 180 n/a PLATES MT20 Weight: 209 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-4-12 oc bracing. REACTIONS. (size)12=0-8-0, 2=0-8-0 Max Horz 2=180(LC 11) Max Uplift 12=-483(LC 12), 2=-483(LC 12) Max Grav 12=1342(LC 1), 2=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2704/1019, 3-5=-2509/955, 5-6=-2365/917, 6-7=-2145/886, 7-8=-2341/939, 8-10=-2988/1112, 10-11=-2507/957, 11-12=-2664/980 BOT CHORD 12-14=-823/2378, 17-18=-573/2140, 16-17=-823/2711, 2-21=-861/2436, 20-21=-643/2034 WEBS 5-21=-110/351, 6-18=-244/741, 8-16=-215/749, 5-20=-608/258, 18-20=-678/2144, 10-14=-499/219, 14-16=-789/2396, 10-16=-63/436, 7-17=-336/814, 8-17=-983/431 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 17-0-0, Exterior(2E) 17-0-0 to 18-0-0, Exterior(2R) 18-0-0 to 22-2-15, Interior(1) 22-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 12 and 483 lb uplift at joint 2. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T15 Truss Type Hip Qty 10 Ply 1 Job Reference (optional) T24642149 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:51 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-dPYHxKWJe5VI45I9h5PJjXH5Rqtvpt8yqbvHaUyyu3g Scale = 1:62.4 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 17 18 19 20 21 22 3x6 ST1.5x8 STP ST1.5x8 STP 4x4 3x6 4x4 4x6 3x4 2x4 3x4 3x8 3x4 3x4 2x4 4x6 4x4 8-9-9 8-9-9 17-0-0 8-2-7 17-6-0 0-6-0 18-0-0 0-6-0 26-2-7 8-2-7 35-0-0 8-9-9 -1-0-0 1-0-0 6-1-3 6-1-3 12-3-13 6-2-10 17-0-0 4-8-3 17-6-0 0-6-0 18-0-0 0-6-0 22-8-3 4-8-3 28-10-13 6-2-10 35-0-0 6-1-3 36-0-0 1-0-0 0-4-17-7-90-4-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.49 0.73 0.71 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.26 -0.45 0.12 (loc) 12-14 12-14 10 l/defl >999 >914 n/a L/d 240 180 n/a PLATES MT20 Weight: 172 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-10-1 oc bracing. REACTIONS. (size)2=0-8-0, 10=0-8-0 Max Horz 2=-185(LC 10) Max Uplift 2=-483(LC 12), 10=-483(LC 12) Max Grav 2=1490(LC 17), 10=1490(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2940/1003, 3-5=-2730/934, 5-6=-1881/747, 6-7=-1881/747, 7-9=-2731/934, 9-10=-2940/1003 BOT CHORD 2-16=-839/2787, 14-16=-619/2220, 12-14=-623/2126, 10-12=-844/2649 WEBS 3-16=-295/212, 5-16=-110/634, 5-14=-699/323, 7-14=-699/323, 7-12=-110/634, 9-12=-295/212, 6-14=-388/1205 NOTES-(7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 17-6-0, Exterior(2R) 17-6-0 to 20-6-0, Interior(1) 20-6-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 10. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T16 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T24642150 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:52 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-5b6f9gXxPPd9iFtLEowYFkpBNECKYR362Fer7wyyu3f Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 3x6 ST1.5x8 STP ST1.5x8 STP 4x8 4x6 3x6 4x4 4x6 3x4 2x4 3x4 3x8 3x4 2x4 4x6 4x4 7-4-11 7-4-11 15-0-0 7-7-5 20-0-0 5-0-0 27-7-5 7-7-5 35-0-0 7-4-11 -1-0-0 1-0-0 7-4-11 7-4-11 15-0-0 7-7-5 20-0-0 5-0-0 27-7-5 7-7-5 35-0-0 7-4-11 36-0-0 1-0-0 0-4-16-7-10-4-16-7-15.00 12 Plate Offsets (X,Y)-- [5:0-5-4,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.80 0.79 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.37 0.13 (loc) 14 14-16 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-3-8 oc bracing. WEBS 1 Row at midpt 3-14, 8-13 REACTIONS. (size)2=0-8-0, 9=0-8-0 Max Horz 2=160(LC 11) Max Uplift 2=-483(LC 12), 9=-483(LC 12) Max Grav 2=1342(LC 1), 9=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2686/1019, 3-5=-1940/809, 5-6=-1719/804, 6-8=-1941/809, 8-9=-2686/1019 BOT CHORD 2-16=-844/2398, 14-16=-844/2398, 13-14=-516/1718, 11-13=-854/2398, 9-11=-854/2398 WEBS 3-16=0/327, 3-14=-751/356, 5-14=-96/441, 6-13=-103/442, 8-13=-751/356, 8-11=0/327 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 15-0-0, Exterior(2R) 15-0-0 to 19-2-15, Interior(1) 19-2-15 to 20-0-0, Exterior(2R) 20-0-0 to 24-2-15, Interior(1) 24-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 9. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T17 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T24642151 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:53 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-Zog1M0YaAjl0JPSYoVRnoyMLHeUGHr?FHuOOfMyyu3e Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 18 19 20 21 22 23 4x4 ST1.5x8 STP ST1.5x8 STP 4x4 4x4 4x6 3x4 2x4 3x8 3x4 3x8 3x4 2x4 4x6 4x4 7-7-12 7-7-12 13-0-0 5-4-4 22-0-0 9-0-0 27-4-4 5-4-4 35-0-0 7-7-12 -1-0-0 1-0-0 7-7-12 7-7-12 13-0-0 5-4-4 17-6-0 4-6-0 22-0-0 4-6-0 27-4-4 5-4-4 35-0-0 7-7-12 36-0-0 1-0-0 0-4-15-9-10-4-15-9-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.85 1.00 0.50 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.35 -0.62 0.14 (loc) 12-13 12-13 8 l/defl >999 >664 n/a L/d 240 180 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)2=0-8-0, 8=0-8-0 Max Horz 2=-140(LC 10) Max Uplift 2=-483(LC 12), 8=-483(LC 12) Max Grav 2=1490(LC 17), 8=1490(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2916/1008, 3-4=-2307/862, 4-5=-2102/837, 5-6=-2102/837, 6-7=-2307/862, 7-8=-2916/1008 BOT CHORD 2-15=-826/2709, 13-15=-826/2709, 12-13=-654/2209, 10-12=-837/2605, 8-10=-837/2605 WEBS 3-15=0/252, 3-13=-654/290, 4-13=-178/682, 5-13=-293/119, 5-12=-293/119, 6-12=-178/682, 7-12=-655/290, 7-10=0/252 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 13-0-0, Exterior(2R) 13-0-0 to 17-6-0, Interior(1) 17-6-0 to 22-0-0, Exterior(2R) 22-0-0 to 26-2-15, Interior(1) 26-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 8. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T18 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T24642152 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:55 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-VAnoniZqhK?kZjcwwwUFtNRl0SEklpYYlCtVkFyyu3c Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 19 20 21 22 4x8 ST1.5x8 STP ST1.5x8 STP 4x8 4x4 3x6 3x4 2x4 3x4 3x8 2x4 3x4 3x4 2x4 3x6 4x4 6-6-5 6-6-5 11-0-0 4-5-11 17-6-0 6-6-0 24-0-0 6-6-0 28-5-11 4-5-11 35-0-0 6-6-5 -1-0-0 1-0-0 6-6-5 6-6-5 11-0-0 4-5-11 17-6-0 6-6-0 24-0-0 6-6-0 28-5-11 4-5-11 35-0-0 6-6-5 36-0-0 1-0-0 0-4-14-11-10-4-14-11-15.00 12 Plate Offsets (X,Y)-- [4:0-5-4,0-2-0], [6:0-5-4,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.58 0.74 0.24 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.20 -0.38 0.13 (loc) 13 13-15 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 174 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-3-8 oc bracing. REACTIONS. (size)2=0-8-0, 8=0-8-0 Max Horz 2=-120(LC 10) Max Uplift 2=-483(LC 12), 8=-483(LC 12) Max Grav 2=1342(LC 1), 8=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2681/1020, 3-4=-2249/910, 4-5=-2410/1014, 5-6=-2410/1014, 6-7=-2249/910, 7-8=-2681/1020 BOT CHORD 2-16=-847/2391, 15-16=-847/2391, 13-15=-653/2037, 11-13=-662/2037, 10-11=-857/2391, 8-10=-857/2391 WEBS 3-15=-434/229, 4-15=-86/369, 4-13=-183/574, 5-13=-401/247, 6-13=-183/574, 6-11=-86/369, 7-11=-434/229 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 11-0-0, Exterior(2R) 11-0-0 to 15-2-15, Interior(1) 15-2-15 to 24-0-0, Exterior(2R) 24-0-0 to 28-5-11, Interior(1) 28-5-11 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 8. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T19 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T24642153 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:56 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-zMLA?2aSSe7bAtA6Te?UQa_rWrXwUCthzsc2Ghyyu3b Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 17 18 19 20 21 22 4x4 ST1.5x8 STP ST1.5x8 STP 3x6 4x4 4x4 4x6 3x8 2x4 3x4 3x4 3x4 3x8 2x4 4x6 4x4 9-0-0 9-0-0 17-6-0 8-6-0 26-0-0 8-6-0 35-0-0 9-0-0 -1-0-0 1-0-0 5-8-11 5-8-11 9-0-0 3-3-5 13-4-12 4-4-12 21-7-4 8-2-8 26-0-0 4-4-12 29-3-5 3-3-5 35-0-0 5-8-11 36-0-0 1-0-0 0-4-14-1-10-4-14-1-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.92 0.94 0.49 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.24 -0.47 0.14 (loc) 14 14-16 10 l/defl >999 >881 n/a L/d 240 180 n/a PLATES MT20 Weight: 164 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)2=0-8-0, 10=0-8-0 Max Horz 2=100(LC 11) Max Uplift 2=-483(LC 12), 10=-483(LC 12) Max Grav 2=1342(LC 1), 10=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2646/1035, 3-4=-2418/938, 4-5=-2219/899, 5-7=-2828/1106, 7-8=-2219/899, 8-9=-2418/938, 9-10=-2646/1035 BOT CHORD 2-16=-865/2377, 14-16=-957/2743, 12-14=-950/2743, 10-12=-875/2377 WEBS 4-16=-266/781, 5-16=-772/331, 7-12=-772/331, 8-12=-266/781 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 13-4-12, Interior(1) 13-4-12 to 26-0-0, Exterior(2R) 26-0-0 to 30-2-15, Interior(1) 30-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 10. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T20 Truss Type HIP GIRDER Qty 1 Ply 2 Job Reference (optional) T24642154 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:57 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-RZvYCOb4DxGSo0lJ1LWjyoX0PFtJDcnrCWMco7yyu3a Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 5x8 ST1.5x8 STP ST1.5x8 STP 3x6 5x8 3x6 4x6 2x4 5x8 2x4 3x4 3x8 2x4 4x6 3x6 7-0-0 7-0-0 14-0-9 7-0-9 20-11-7 6-10-13 28-0-0 7-0-9 35-0-0 7-0-0 -1-0-0 1-0-0 7-0-0 7-0-0 14-0-9 7-0-9 20-11-7 6-10-13 28-0-0 7-0-9 35-0-0 7-0-0 36-0-0 1-0-0 0-4-13-3-10-4-13-3-15.00 12 Plate Offsets (X,Y)-- [3:0-5-12,0-2-8], [7:0-5-12,0-2-8], [12:0-3-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.91 0.93 0.70 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.41 -0.77 0.18 (loc) 12-13 12-13 8 l/defl >999 >533 n/a L/d 240 180 n/a PLATES MT20 Weight: 314 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 *Except* 3-5,5-7: 2x4 SP M 31 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 9-7-6 oc bracing, Except: 7-9-2 oc bracing: 12-13. REACTIONS. (size)2=0-8-0, 8=0-8-0 Max Horz 2=80(LC 7) Max Uplift 2=-1078(LC 8), 8=-1078(LC 8) Max Grav 2=3160(LC 1), 8=3160(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-7173/2323, 3-4=-9844/3267, 4-6=-9843/3267, 6-7=-9840/3266, 7-8=-7174/2323 BOT CHORD 2-15=-2032/6494, 13-15=-2039/6527, 12-13=-3129/9839, 10-12=-2039/6528, 8-10=-2032/6495 WEBS 3-15=-135/670, 3-13=-1184/3696, 4-13=-990/410, 6-12=-1010/410, 7-12=-1183/3690, 7-10=-136/672 NOTES-(11) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1078 lb uplift at joint 2 and 1078 lb uplift at joint 8. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 199 lb down and 65 lb up at 7-0-0, and 199 lb down and 65 lb up at 28-0-0 on top chord, and 375 lb down and 123 lb up at 7-0-0, and 375 lb down and 123 lb up at 28-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."Continued on page 2 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss T20 Truss Type HIP GIRDER Qty 1 Ply 2 Job Reference (optional) T24642154 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:57 2021 Page 2 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-RZvYCOb4DxGSo0lJ1LWjyoX0PFtJDcnrCWMco7yyu3a LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-7=-134(F=-80), 7-9=-54, 2-15=-20, 10-15=-59(F=-39), 8-10=-20 Concentrated Loads (lb) Vert: 3=-199(F) 7=-199(F) 15=-375(F) 10=-375(F) Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss V01 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) T24642155 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:58 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-wlTwPjci_FOJQAKVb31yV?3IufNwyD?_RA59Kayyu3Z Scale = 1:12.2 1 2 3 4 2x4 2x4 2x4 4-6-3 4-6-3 0-0-41-10-95.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.48 0.26 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-5-9, 3=4-5-9 Max Horz 1=74(LC 9) Max Uplift 1=-42(LC 12), 3=-46(LC 12) Max Grav 1=134(LC 1), 3=135(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 4-4-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 42 lb uplift at joint 1 and 46 lb uplift at joint 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss V02 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) T24642156 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:59 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-Ox1Id3cKlZWA1Kvh9mYB2DcYo3nXhgF8fqrit0yyu3Y Scale: 1.5"=1' 1 2 3 2x4 2x4 2x4 2-6-3 2-6-3 0-0-41-0-95.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.08 0.05 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-5-9, 3=2-5-9 Max Horz 1=33(LC 9) Max Uplift 1=-19(LC 12), 3=-21(LC 12) Max Grav 1=60(LC 1), 3=60(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 19 lb uplift at joint 1 and 21 lb uplift at joint 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss V03 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) T24642157 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:52:59 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-Ox1Id3cKlZWA1Kvh9mYB2DcQI3iuhgF8fqrit0yyu3Y Scale = 1:13.1 1 2 3 4 2x4 2x4 2x4 5-0-0 5-0-0 0-0-42-1-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.63 0.34 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-11-6, 3=4-11-6 Max Horz 1=84(LC 9) Max Uplift 1=-47(LC 12), 3=-52(LC 12) Max Grav 1=152(LC 1), 3=153(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 4-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 47 lb uplift at joint 1 and 52 lb uplift at joint 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0031 Truss V04 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) T24642158 8.430 s Jun 2 2021 MiTek Industries, Inc. Mon Jul 12 06:53:00 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-s8bhqPdzWse1fUUuiU3QaQ9iYT5DQ7VHuUaGPSyyu3X Scale = 1:9.0 1 2 3 2x4 2x4 2x4 3-0-0 3-0-0 0-0-41-3-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.15 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-11-6, 3=2-11-6 Max Horz 1=43(LC 9) Max Uplift 1=-24(LC 12), 3=-27(LC 12) Max Grav 1=78(LC 1), 3=78(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 24 lb uplift at joint 1 and 27 lb uplift at joint 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. July 12,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths