Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR RECEIVER JUN 0 S 2021 BUILDIN Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Vides Residence Builder Name: Street: Lot 2 Johnson Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jose & Lisa Vides Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$2400.7 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Polystyrene Bead AggR=0.0 2020.70 ft2 b. Frame - Wood, Adjacent R=11.0 380.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (2672.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2672.00 ft2 6. Conditioned floor area above grade (ft2) 2672 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. /A R= ft2 7. Windows(368.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft2 6 .90 a. U-Factor: Sgl, U=0.45 368.00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 41.5 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 10.576 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 34.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A - a. Propane Tankless Cap: 1 gallons 9. Floor Types (2672.0 sqft.) Insulation Area EF: 0.600 a. Slab -On -Grade Edge Insulation R=0.0 2672.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits CF, Pstat Glass/Floor Area: 0.138 Total Proposed Modified Loads: 78.34 PASS Total Baseline Loads: '79.34 I hereby certify that the plans and specifications covered by Review of the plans and D��HESTq?� this calculation are in compliance with the Florida Energy specifications covered by this zz 0�, Code. calculation indicates compliance with the Florida Energy Code. Jmr,: PREPARED BY: Before construction is completed �` "Q DATE: 4-6-231211 this building will be inspected for compliance with Section 553.908 I hereby certify that this b ild' g, as designed, is in compliance Florida Statutes. with the Florida Ener Olj `OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). 4/5/2021 12:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Vides Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2672 Lot # Owner Name: Jose & Lisa Vides Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: Lot 2 Johnson Road Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce, Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2672 28308 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Bedroom 2 196 1960 No 2 1 1 Yes Yes Yes 2 Bath 2 110 1100 No 0 1 Yes Yes Yes 3 Toilet 2 24 240 No 0 1 No Yes Yes 4 WIC 2 60 600 No 0 1 Yes Yes Yes 5 Pantry 36 360 No 0 1 No Yes Yes 6 Laundry 96 960 No 1 1 Yes Yes Yes 7 Hall 36 360 No 0 1 No Yes Yes 8 Mud Room 48 480 No 1 1 No Yes Yes 9 Family Room 625 7500 No 4 1 Yes Yes Yes 10 Kitchen 299 2990 Yes 2 1 No Yes Yes 11 Safe Room 25 250 No 1 1 No Yes Yes 12 Closet 36 360 No 0 1 No Yes Yes 13 Bath 36 360 No 0 1 No Yes Yes 14 Study 144 1440 No 2 1 Yes Yes Yes 15 Foyer 100 1100 No 0 1 Yes Yes Yes 16 Master Bedroom 238 2618 No 2 1 1 Yes Yes Yes 17 M Bath 140 1400 No 1 1 Yes Yes Yes 18 M Toilet 28 280 No 0 1 Yes Yes Yes 19 M WIC 84 840 No 0 1 Yes Yes Yes 20 Closet 3 36 360 , No 0 1 No Yes Yes 21 Bath 3 78 780 No 0 1 Yes Yes Yes 22 Bedroom 3 197 1970 No 1 1 1 Yes Yes Yes 4/5/2021 12:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Bedroom 2 28 ft 196 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulatio Bath 2 9 ft 110 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulatio Toilet 2 1 ft 24 ft2 ____ 1 0 0 4Slab-On-Grade Edge Insulatio WIC 2 6 ft 60 ft2 _-__ 1 0 0 5 Slab -On -Grade Edge Insulatio Pantry 1 ft 36 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulatio Laundry loft 96 ft2 __-- 1 0 0 7 Slab -On -Grade Edge Insulatio Hall 1 1 ft 36 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulatio Mud Room 1 ft 48 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulatio Family Room 25 ft 625 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulatio Kitchen 1 ft 299 ft2 -_-_ 1 0 0 11Slab-On-Grade Edge Insulatio Safe Room 1 ft 25 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulatio Closet 1 ft 36 ft2 1 0 0 13SIab-On-Grade Edge Insulatio Bath 1 ft 36 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulatio Study 16 ft 144 ft2 __-- 1 0 0 15SIab-On-Grade Edge Insulatio Foyer 8 ft 100 ft2 _-__ 1 0 0 16SIab-On-Grade Edge Insulatio Master Bedroom 31 ft 238 ft2 __-- 1 0 0 178Iab-On-Grade Edge Insulatio M Bath 8 ft 140 ft2 -___ 1 0 0 18SIab-On-Grade Edge Insulatio M Toilet 4 ft 28 ft2 ___- 1 0 0 19SIab-On-Grade Edge Insulatio M WIC 6 ft 84 ft2 ____ 1 0 0 20SIab-On-Grade Edge Insulatio Closet 3 1 ft 36 ft2 _-_- 1 0 0 21SIab-On-Grade Edge Insulatio Bath 3 9 ft 78 ft2 -_-- 1 0 0 22SIab-On-Grade Edge Insulatio Bedroom 3 33.2 ft 197 ft2 -___ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2988 ft2 0 ft2 Light N 0.6 No 0.9 No 20 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2672 ft2 N N 4/5/2021 12:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Bedroom 2 0 Blown 196 ft2 0.1 Wood 2 Under Attic (Unvented) _ Bath 2 0 Blown 110 ft2 0.1 Wood 3 Under Attic (Unvented) Toilet 2 0 Blown 24 ft2 0.1 Wood 4 Under Attic (Unvented) WIC 2 0 Blown 60 ft2 0.1 Wood 5 Under Attic (Unvented) Pantry 0 Blown 36 ft2 0.1 Wood 6 Under Attic (Unvented) Laundry 0 Blown 96 ft2 0.1 Wood 7 Under Attic (Unvented) Hall 1 0 Blown 36 ft2 0.1 Wood 8 Under Attic (Unvented) Mud Room 0 Blown 48 ft2 0.1 Wood 9 Under Attic (Unvented) Family Room 0 Blown 625 ft2 0.1 Wood 10 Under Attic (Unvented) Kitchen 0 Blown 299 ft2 0.1 Wood 11 Under Attic (Unvented) Safe Room 0 Blown 25 ft2 0.1 Wood 12 Under Attic (Unvented) Closet 0 Blown 36 ft2 0.1 Wood 13 Under Attic (Unvented) Bath 0 Blown 36 ft2 0.1 Wood 14 Under Attic (Unvented) Study 0 Blown 144 ft2 0.1 Wood 15 Under Attic (Unvented) Foyer 0 Blown 100 ft2 0.1 Wood 16 Under Attic (Unvented) Master Bedroom 0 Blown 238 ft2 0.1 Wood 17 Under Attic (Unvented) M Bath 0 Blown 140 ft2 0.1 Wood 18 Under Attic (Unvented) M Toilet 0 Blown 28 ft2 0.1 Wood 19 Under Attic (Unvented) M WIC 0 Blown 84 ft2 0.1 Wood 20 Under Attic (Unvented) Closet 3 0 Blown 36 ft2 0.1 Wood 21 Under Attic (Unvented) Bath 3 0 Blown 78 ft2 0.1 Wood 22 Under Attic (Unvented) Bedroom 3 0 Blown 197 ft2 0.1 Wood WALLS Adjacent Cavity Space Cy Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Polystylkdroom 2 0 14 0 10 0 140.0 ft2 0 0 0.5 0 _ 2 E Exterior Concrete Block - Polystytodroom 2 14 0 10 0 140.0 ft2 0 0 0.5 0 _ 3 N Exterior Concrete Block - Polystyrer8ath 2 9 0 10 0 90.0 ft2 0 0 0.5 0 _ 4 N Exterior Concrete Block - PolystyrerW IC 2 6 0 10 0 60.0 ft2 0 0 0.5 0 5 N Exterior Concrete Block - Polystyrdoaundry 10 0 10 0 100.0 ft2 0 0 0.5 0 _ 6 E Exterior Concrete Block - Polystftmily Room 25 0 12 0 300.0 ft2 0 0 0.5 0 7 S Exterior Concrete Block - PolystyrerStudy 4 0 10 0 40.0 ft2 0 0 0.5 0 8 W Exterior Concrete Block - PolystyrenStudy 12 0 10 0 120.0 ft2 0 0 0.5 0 _ 9 N Exterior Concrete Block - PolystyrerFoyer 1 0 11 0 11.0 ft2 0 0 0.5 0 10 S Exterior Concrete Block - Polystyrerfoyer 1 0 11 0 11.0 ft2 0 0 0.5 0 _ 11 W Exterior Concrete Block - PolystyrerFoyer 6 0 11 0 66.0 ft2 0 0 0.5 0 12 E Exterior Concrete Block - Polystpeater Bedro 14 0 11 0 154.0 ft2 0 0 0.5 0 _ 13 S Exterior Concrete Block - Polystpeater Bedro 17 0 11 0 187.0 ft2 0 0 0.5 0 _ 14 S Exterior Concrete Block - PolystyreM Bath 8 0 10 0 80.0 ft2 0 0 0.5 0 15 S Exterior Concrete Block - PolystyreM Toilet 4 0 10 0 40.0 ft2 0 0 0.5 0 16 S Exterior Concrete Block - PolystyreM WIC 6 0 10 0 60.0 ft2 0 0 0.5 0 _ 17 S Exterior Concrete Block - PolystyrerBath 3 9 0 10 0 90.0 ft2 0 0 0.5 0 _ 18 N Exterior Concrete Block - Polystyfkdroom 3 4 0 10 0 40.0 ft2 0 0 0.5 0 4/5/2021 12:15 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 19 S Exterior Concrete Block - Polysty8edroom 3 12 0 10 0 120.0 ft2 0 0 0.5 0 20 SW Exterior " Concrete Block - Polystylodroom 3 3 7 10 0 35.8 ft2 0 0 0.5 0 21 W Exterior Concrete Block - Polystyfledroom 3 10 0 10 0 100.0 ft2 0 0 0.5 0 _22 NW Exterior Concrete Block - Polystyftsdroom 3 0 3 7 10 0 35.8 ft2 0 0 0.5 0 _23 W Garage Frame - Wood Laundry 11 8 10 80.0 ft2 0.23 0.5 0 _24 N Garage Frame - Wood Mud Room 11 4 10 40.0 ft2 0.23 0.5 0 _25 W Garage Frame - Wood Mud Room 11 8 10 80.0 ft2 0.23 0.5 0 26 W Garage Frame - Wood Safe Room 11 5 10 50.0 ft2 0.23 0.5 0 _27 N Garage Frame - Wood Closet 11 1 10 10.0 ft2 0.23 0.5 0 _28 N Garage Frame - Wood Study 11 12 10 120.0 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Foyer None .39 3 8 24 ft2 2 W Insulated Mud Room None .39 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Vinyl Low-E Single Yes 0.45 0.25 Y 54.0 ft2 15 ft 0 in 1 ft 4 in None None 2 N 3 Vinyl Low-E Single Yes 0.45 0.25 Y 8.0 ft2 1 ft 5 in 1 ft 4 in None None 3 N 5 Vinyl Low-E Single Yes 0.45 0.25 Y 6.0 ft2 1 ft 5 in 1 ft 4 in None None 4 E 6 Vinyl Low-E Single Yes 0.45 0.25 Y 128.0 ft2 15 ft 0 in 1 ft 4 in None None 5 W 8 Vinyl Law-E Single Yes 0.45 0.25 Y 36.0 ft2 6 ft 0 in 1 ft 4 in None None 6 E 12 Vinyl Low-E Single Yes 0.45 0.25 Y 36.0 ft2 15 ft 0 in 1 ft 4 in None None 7 E 12 Vinyl Low-E Single Yes 0.45 0.25 Y 18.0 ft2 15 ft 0 in 1 ft 4 in None None 8 S 14 Vinyl Low-E Single Yes 0.45 0.25 Y 16.0 ft2 1 ft 5 in 1 ft 4 in None None 9 S 17 Vinyl Low-E Single Yes 0.45 0.25 Y 8.0 ft2 1 ft 5 in 1 ft 4 in None None 10 SW 20 Vinyl Low-E Single Yes 0.45 0.25 Y 11.0 ft2 1 ft 5 in 1 ft 4 in None None 11 W 21 Vinyl Low-E Single Yes 0.45 0.25 Y 36.0 ft2 1 ft 5 in 1 ft 4 in None None 12 NW 22 Vinyl Low-E Single Yes 0.45 0.25 Y 11.0 ft2 1 ft 5 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 609 ft2 609 ft2 38 ft loft 11 4/5/2021 12:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000404 2830.8 155.31 291.57 .1212 6 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 41.5 kBtu/hr cfm 0.7 1 sys#1 - HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Exterior 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS --- Supply --- V # Location R-Value Area -- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 90 ft2 Attic 20 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y CoolingH Jan H Feb [[ ]] Mar HeatinJan Feb [X] Mar Venting Jan Feb [[XX]] Mar Ceiling Fans: [ j Apr I Ma rlJun Jul [X� Au [X] Se (]Oct [ ] Apr May Jun l Jul [ ] Au[ ]Sep [ ] [X) Apr May Jun [ Jul [ j Aug [ ] Se [X] i Nov Oct Nov Oct Nov Dec Dec Dec 4/5/2021 12:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 - 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Toilet 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Mud Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Family Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Safe Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Closet Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Study Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 M Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 M Toilet Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 Closet 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 3 Default(8 Ibs/s .ft. ft2 ft 0.3 Bedroom 3 4/5/2021 12:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7