Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Manual J Worksheets
-r- wrightsoft, Right-JO Worksheet Date: Entire House JUN ®3 2021 Date: Quick Calcs, Inc. By: LlssT,LucieCounty, Permitting 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: qulckcalcs@aol.com 1 Room name Entire House Bedroom 2 2 Exposed wall 193.2 ft 28.0 ft 3 Room height 10.6 It 10.0 ft heat1cool 4 Room dimensions 14.0 x 14.0 ft 5 Room area 2672.0 fP 196.0 fN T Y Construction U-value Or HTM I Area ft' () Load Area ft' I () Load number (StuhHt" (stuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 war-+G 13A 7.5ocs 18 rlfv 0.095 0.980 n. n' : 2 66 2744 1.26 21.83 441 6 427 0 y 1136 165 546 131 140 -6 140 0 372 0 177 "0 �--G .18 rlfv .-._: _,. - .._. _. _: 0.980 _ m ,-_27.44 ._ 21,83 r 8 _ 13A-7.5ocs 0.095 . a 2.66 1.26 594 _0 358 _ 952 452 140 86 229 109 11 1A-rlov 0.900 a 25.20 42.33 36 0 907 1524 0 0 0 0 1A-r1ov 0.900 a 25.20 19.79 72 144 1814 1425 54 54 1361 1069 1 A r1 ovd _ 0.900 a -• 25 20 19.79 128 256 3226 2533 0 _ 0 _ 0 13A 7 5ocs O'095 s 2 66 1 26 628 604 1607 763 _ 0 0 •0 0 0 16 rlfv : ` :18-r1fv- - __,- _ _. O'980 ,' . _ ___0 980 s, _ s.- 27.44 _.. _ .27.44. 21 83 ,, _ 21.83 , 16 -. _ :-.8 . , 32 _.-16 .. 439 -220 ,... 349 '__ 175 0 - : _.0 . .:, __ 0 _-.. _ 0 .____ 0 0 -.-- 0 .•_-0 VI/ 13A-7.5ocs 0.095 sw 2.66 1.26 36 25 67 32 0 0 0 0 0.900 -sw ---- - 25.20 _ _ -31.01 11 5 _ 277 .. 341 .. - 0 0 .. _.•..- -0 _ ._ ..0 13A 7.5ocs 0.095 w 2.66 1.26 286 190 505 240 0 6 0 0 1A rlov ,1A r1ov ; .0.900 0.900 w= , w. 25.20 25.20, 42.33 28:50 36 36 0 `44 907 907 1524 1026 �0 "0 ° -:0 0 ' 0 0 0 0 _D _11D0 ___.,_ _.._____.:.____:0.390-w' ._-._10.92 -, _A0.34 s. _:.::24 24 ___-_262.___.•__ 248:_....... _._0:._ ._.... .6,__ -:,_0 __-_. __0 13A-7.5ocs 0.095 nw 2.66 1.26 36 25 67 32 0 0 0 0 C-_76X19-Omd._ F 1A-rlov _... ._ ... ,.._ 22A tol -_.•-, 0.900 ..- _ _ . , . 0A08 0.989 nw _ _: -__ .--, 25.20 . _ _ _ 1.59 27.09 34.05 _ _, .1.37 t" ,0.00 11 _ ._. -2672 -2672 m___ 0 _ ._ _ .2672 _193 277 _ . - _ _._-.4287. _5349 _- -- 375 _ _.._ 3656 ... . 0, -_ 0 _ _,... 196 -196 .- : 0 _ .196 :. -28 0 .. 311. 775 ._ . _ _-, _- ___0 _268 - _0 61 c) AED excursion 1 13221 1 1120 Envelope loss/gain 23540 15661 3048 1503 12 a) Infiltration 4646 1244 644 172 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 17 3910 2 460 Appliances/other 3400 0 Subtotal (lines 6 to 13) 28186 24415 3692 2135 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 28186 24415 3692 2135 15 Duct loads 20% 16% 5773 3936 20% 16% 756 344 Total room load 339591 28351I 44411 24791 Air required (cfm) I I I 1383 1383 I I 181 121 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -d- wrllo"V "rt� 2021-Apr-0512:23:33 ��� " ^^' °^^•°^ RightSuite®Universal 2019 19.021 RSUD8101 Pagel ..r\Documents\Wdghtsoft HVAC\Vides Residence.rup Calc = MJ8 Front Door faces: W - wrightsoft• Right-JO Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Bath 2 Toilet 2 2 Exposed wall 9.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 110.0 ft 4.0 x 6.0 ft 5 Room area 110.0 f? 24.0 ft' T y Construction number U-value (Btuh/ft2_ F Or I HTM (Btuhlft') I Area ft' or perimeter (ft) I Load (Btuh) I Area ft' or perimeter (ft) I Load (Stuh) Heat Cool Gross N/P/S Heat I Cool Gross NIP/S Heat Cool 6 'It: 13A 7 5ocs. } 0,095 n"' -2"66 1:26 90 82 218 104 0 0 D 0 --G 1B rlfv 0.900 n 27.44 21i83 0 0 0 0 0 0 0 0 ,n. 27.44 21.83 _. _ ._8 .. _.. _ U _._. _..220 ._ .. __ 175.._.... _ .__ _.._0 _ ._ _.._0 - ._..., --0 _ 13A-7.5ocs _0_980. 0.095 a 2.66 ._. 1.26 0 0 0 0 0 0 0 0 11 -G 1A-r1ov 0.900 a 25.20 42.33 0 0, 0 0 0 0 0 0 1A-r1ov 1Ar1ovd - 13A-7 5ocs " 1 B rlfv 18 r1fv_, _ ,° __ 4 0.900 0900,-e, 0 095 0 980 0.980 a s , s - s ....._.27.44;...._21.83..... 25.20 2520 2 66 27 44, 19.79 1979 1.M 21.83 0 ,0 0 A 0 __.. 6 0 0 0 0 _ ..: 0 0 0 „' 0 _:0.._:_ 0 0 0 0 ... _0 ._ 0 0 0 0 _._._ ..0 0 0 0 0 .___ ._ __ 0 ._. 0 0 0 ;0 _ _0 _._ 0 0 0 0 0 _,. 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0 -1A-r1ov....._ .13A 7.5ocs . 1A rlov ._. R, - 0.900.-sw 0.095 0.900 w w ___25.20, 2.66 25.20 _ . 31,01 1',26 42.33 _.. 0 .. :.; :0 0 ._ ...;, 0 0 0 _ ._..-., •. 0 0 0 0 .. 0 0 0 0 _- . 0 0 U 0 0 6 0. IA r1ov 0.900 w' 25.20 ' 28.50 -0 0 0 0 0 0 0 0 _D _1]DO--_-.._. M . -_ i 0.390 ___w _10.92 .__.-10.34.. . ___ :0 __ _..__.: _0 -_-a _.. 0 .__.._ _ -0 - -_-_' ---- 0 __ _ _..._.,0 _ .--..'_._0 _.._ _..__0. Val 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0 t-G C_ .' ..16X190md. 1A-r1ov 0.900 __- 0A08 nw -. -_.. 25.20 ._..1.59 34.05 _ ._.1:37 0 .. 1:10 0 110 - - 0 .;. 174 _.__.., 0 150 _._-.. 0 _24', _ 0 .__..24 0 ._._ . _38 _ 0 33 22A-tpl - _-- _ . ,.. _ _ . _... _. 0.989 .. -_._ _... 27.69 -_ . , 0.00 _ _ ----110 _...__ 711 ._ ..9 ..___249 _.,._.,. _ _ _0. ._ w_.24 _ _.:,_ __ 0 _.. __.Q _ ... 0 6 c) AED excursion 1 -26 -2 Envelope loss/gain 1 861 403 1 38 31 12 a) Infiltration 207 55 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1068 458 38 31 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1068 458 38 31 15 Duct loads 20% 16% 219 74 20% 16% 8 5 load 1252I 526I 42 32I Air requTotl ir d (c m) I I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. + wrlghtndMtt*' 2021-Apr-0512:23:33 wm^ �^-- �• RightSuite®Univerml201919.021 RSUD8101 Paget ...rlDocumentsUrightsoft HVAMVides Residence.rup Cale = MJ8 Front Door faces: W -Fp- wrightsoW Right-J® Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name WIC 2 Pantry 2 Exposed wall 6.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 10.0 x 6.0 ft 6.0 x 6.0 ft 5 Room area 60.0 fN 36.0 fN T y Construction U-value Or I HTM I Area ft' I Load I Area ft' I Load number (BtuhNt'= F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross I N/P/S Heat Cool Gross N/P/S Heat Cool 6 w 13A 7 5ods; 0 095 n 2 6-6 1 26 60 60 160 76 0 0 0 0 18 r1 fv 0.980 n. 27.44 21 83 0 0 0 0 0 0. 0 0 0.980 ... W ,....27 0 .... - _ _0 _ .._, _... _0 .._ ,... .0 13A-7.5ocs 0.095 a 2.66 1.26 0 0 0 0 0 0 0 0 11 1A-r1ov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 1A-r1ov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0 _.. 1A_r1ovd _ _. _.. 0.900 ._e - 25.20 _ -,19.79 0 - ._..__._O _ _ _-0 __,... ---__0 _-- -- _0 ... 0 ._. 0 _____ .0 13A 7 5ocs 113 r1fv _1Brlfv :i_.�;: 0.095 0.980 __.. ,0.980 6 s' r_... 2.66 27.44: .27.44, 7-.26 21.83 _21;83 0 A _. __w0 _.. 0 0 '.,0_._.,, 0 0 ._._0._ _... 0 0 0 .. 0 0 ,. _„A _ ,.___._.D 0 0 .__ ... 0 0 _0 _.__, 0 0 _.0. �1 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0 �-( 1A-r1ov.... 0,900 25.20. - _ 31.01 '-0 _- ..----_0 _-- _.O _. _ ._ -_ __0 _... _ - 0 ..-._ _ _-- _0 _--_ _ 0. _ _. _ _ 0 _ _ --_- -_.. 13A 7.5ocs 1A rlov '.' 1A r1ov r _.-sw_ 0.095 0.900 0:900 w w w -' .... 2.66 25.20, 25.20 L26 42.33 26.50 D 0 0 _ 0 0 0 o 0 0 0 0 0. 0, 0 0 0 0 0 0 0 0 6 0 0 _D 11D0 ., _ 0.390 10.92 .10.34 ___.._...0 -._ _.. --0 .__. __:0 ..._. __ 0' Vy 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0 L_ _G C. .. _" 1 A-r1 ov 16X19-Omd .u_, _ ... 0.900 .0.408 __,-_. nw _: 25.20 . '1.59 34.05 , `. �__-1:37 _._v.., 0 '60 _ .: 0 __., 60 ._ 0 - -__ 95 ._ .-. 0 _ .82 ._ 0 ... _. 36 0 36 ,... _.._57_ 0 , _ 0 _ _49 F . , 22A tpl�_ _._ 0., 989 -.,. 27.69 _.0.00 _ 60 _. _ 6 .-_ ..., 166 ., ... 0 _,.._. .. 36 _..... 0 0 0 61 c) AED excursion -10 -3 Envelope loss/gain 421 1 148 1 1 57 47 12 a) Infiltration 138 37 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 559 184 57 47 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 14 12 14 Subtotal 559 184 71 58 15 Duct loads 20% 16 % 114 30 20% 16 % 15 9 Total room load 673 214 86 68 Air required (cfm) I I I 27I 10I I I 4 3 Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed. -Orf- wrriflift YC 2021-Apr-0512:23:33 •- RightSuite@Universa12019 19.021 RSUO8101 Page ...ADocumentsUrightsoft HVAC%Vides Residence.rup Calc = MJ8 Front Door faces: W - wrightsoft* Right -A) Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772.466-6799 Email: quickcalcs@aol.com 1 Room name Laundry Hall 1 2 Exposed wall 10.0 ft 0 ft 3 Room height 10.0 ft heattcool 10.0 ft heat/cool 4 Room dimensions 1.0 x 96.0 ft 6.0 x 6.0 ft 5 Room area 96.0 fP 36.0 fP T y Construction U-value Or HTM I Area ft' I Load Area ft' I Load I number (Btuh/ft'-° (Btuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1ry 73A 7.Socs• 0095 n 2:66 1 26 100 94 250 119 '. O 0 Q _ ....0 EL-_ GG 113rlfv _18_rlfv __ ._._ .. _ - .._ 0 980 _- ,0980.. n n„ 27.44, _27.44 21.63 21.83 6 ._" -0 0 _._._ --- 0 165 _._ ..:__0 131 . 0 0 ..___ ___0 0 __ . ---- 0 0 __..__ 0 0 _. .. _0 13A-7.5ocs 0.095 a 2.66 1.26 0 0 0 0 6 0 6 6 11 1 A-r1 ov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 L-G 1 A-rl ov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0 1A rlovd 13A 7 5ors 1B-rlfv 0.900 0.095 0:980 .0980 e.. s s _, s. 25.20 2.66 27.44 _ _.27,44...._ 19.79 1 26 21.83 21:83 0 0 0 .. _ _`e0 0 0 0 . __ __ _.D _ 0 0 0 _ _ 0 0 0 0 . _ `--- 0 0 0 0 _.__.1 ___0 0 0 0' ___ _ 0 _ 0 0 0 _ ,_ .. ;0 0 0 0 __. 0 y/ 13A-7.5acs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0 C 16-rlov .._ 13A7.50cs; „{ 1A rlov . IA-06v 0.90.0... " 0.095 0.90 0.900 sw.. ,"w w w _25.20. 2.66 25.20 25.20 _31.01 .1,26 ' 42.33 28.50 0 0 0 ._ .;, 0 0 , 0 0 0 0 0 0 __._ .. 0 0 0 0 . ._ - ,0 0 . ' 0 0 _. 0 0 ' 0 U __A 0 0 0 . .._ _ .0. 0 0 -0 D .11D0 __ •0.390 . w:...: ,__..10.92 _ '.10.34 _ - _••,_0 -...__ .0 _ _ ___ 0 _._.;_ _0 _ _ -_---__0 ._. _._ _ 0 . _ __..__ .D -- -. _ _ 0 Vy 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0 L-G 1A-r1ov 0.900 nw 25.20 34.05 0 0 0 0 0 0 0 0 0.408 _ __ _ _ 1.59 -,1.37 .: .._.. _-96 _ .__ 96 , _. -. . 152 .. _ _:_ 131 _ ___ 36 "_ _ _ 38' _ . _57 _.. 49 F _ _ ....22A-tPl. .: _. .. 0.989 r.. _ 71 .._ _ .27.69 . - 0.00 _._ 96 10 . _... 277 0 ..36 ._...___ _ 0 . .... 0. 61 c) AED excursion 1 -621 13 Envelope loss/gain 1 844 319 1 1 57 47 12 a) Infiltration 230 62 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13) 1074 111C 57 47 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 14 12 S7 -47 14 Subtotal 1088 1122 0 0 15 Duct loads 20% 16% 223 181 20% 16% 0 0 roomloadI 13I 13I 01 I I 53 64 I I 0 IAirreqd) D Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -rid- wrlgtitecottt" 2021-Apr-0512:23:33 RIghtSuite®Universa1201919.021RSU08101 Page r\Documents\Wrightsoft HVACIVides Residence.rup Calc = MJ8 Front Doorfaces: W - wrightsottp Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By, 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Mud Room Family Room 2 Exposed wall 0 ft 25.0 ft 3 Room height 10.0 ft heat/cool 12.0 ft heat/cool 4 Room dimensions 8.0 x 6.0 ft 25.0 x 25.0 ft 5 Room area 48.0 ft' 625.0 fN T y Construction U-value Or HTM Area ft' Load Area ft' Load number (Btuh/ft'° (Stuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat cool::] 6 j3A 7 Sots 0:095 n 2 66 1.26 0 0 0 0 0 0 A 0 1Br9fv 0980 n- 2744' 21.93 0 0 0 0 0 0 0 ;.o ,16,rtfv ... a .. 0:980_ n 27.44 .:'_0 w 0 a._..r i] 0 4 ;:. Q_. � _� Q 13A-7.50cs 0.095 _., a 2.66 . ._21,83 _..._ 1.26 0 0 .- 0 _._.-<_ 0 300 _. 172 __..__._ 458 __.,." 217 11 1A-r1ov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 1Ar1ov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0 1 A r1 ovd 0.900 e 25.20 19.79 0 0 0 0 128 128 3226 2533 13A 7 sots ' 0 095 _ s 2 66 1 26 0 0 0 0 r 0 0 . 0 0 16 r1 fv 0;980 s, 27 44 21.83 0 V110 0 0 0 °. 0 ; 0 0 .1B rlfv _ ..•__.._._ _ _0.980 s ..... ,2744: ___ 21.83 . _ _ 0 0 W 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0 1A-rlov_- 0.900 -sw„ -25.20 31.01 0 0 - _, 0 0 -, 0 0 0 13A 7 Sots 0 095 W, , _ 2 66, 1 28 0 „_ 0 0 ., ... .:. 0 - „0 0 0 0 - `0 1A rlov 0 900 w_ 25 20 42 33 9 0 0 0 0 0 0 0 1 A r1 ov 0 900 w 25 20 28 50 0 0 0 0 0 0 0 0 ,.0.390_._w_ ...._.10.92 ..__10.34 ...__ _ 0 ___.-_.._ 0 ._ 0 0 .._._. __ 0.__- __...0:. __ .__.o 0 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0 1A-r1ov 0.900 nw 25.20 34.05 0 0 0 0 0 0 0 0 _ ,4848 .._ , .__ _ 76 .. _._:_ 66 . , A25 - • , 825 F _ _ .-_ 22A tpl _.__. W ., . - _ -0.989 ..,. 27,69 0.00 48 0 ._.. 0 _ 0 __.,. 625 ..;. _ 25 _692 0 _ 2. 6 c) AED excursion -16 - -298 Envelope loss/gain 76 50 5366 3307 12 a) Infiltration 0 0 690 185 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 4 920 Appliancesiother 0 900 Subtotal (lines 6 to 13) 76 280 6056 5312 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 14 12 0 0 14 Subtotal 90 292 6056 5312 15 Duct loads 20% 16 % 19 47 20% 16% 1240 856 tal load 104I 317I 7297I 6301 Air requi droom (c m) I I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -44-- w"rigt�l RsfR" 2021-Apr-0512:23:33 AC.11 ,< -� RightSuite®Universal 2019 19.021 RSU08101 Pages ...rlDocuments\Wdghtsoft HVACWides Residence.rup Calc = MJ8 Front Door faces: W - - wrightsoft, Right-M Worksheet Job: Entire House Date: Quick Caics, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Kitchen Safe Room 2 Exposed wall O ft O ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 23.0 x 13.0 ft 5.0 x 5.0 ft 5 Room area 299.0 ft 25.0 ft' Ty Construction U-value Or HTM Area (ft') I Load I Area (ft') I Load I number (Btuh/Ft'=F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A 7 5dds r 0.095 n ` 2,66 1.26 _ U 6 0 w 0 -- - -0 _6 �-0 , 0 1 B rlfv 0.980 , n 27.44 21.83 0 0 0 0 0 0 0 0 21.83 - .'0 __.0 0 _.. _.0 _. ._. - 13A-7.5ocs 0.095 a 2.66 1.26 _. 0 _._ 0 0 0 0 0 0 0 11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 1A-rtov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0 --G 1 A r1 ovd 13A 7 5ocs 0.9D0 0.095 980 a s 25 20 2.66 27.44 19 79 1 26 21 83 0 j 0 0 0 0 1 0 0 ' 0 0 0 0 0 0 0 0 0 0 0 01 0 0 0' 0. _'G_ 1B,rtiv _ .: - _ .. _' .. - 0.980 t - s, . 27.44....2183 ,.__..rOA_ .__ '_0----,:_ A._.-.: _0.-=._._..0____ _---Q;_... .<.0_..... ...0 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0 �=G -1A-rtov _ ._ _. , 13A7.5ocs 0.900 -0.095 ..sw- w . 25.20 -Z66 __---.31.01 •1.26 _ , _ . -0,- 0 .. __0 0 _ 0 0 .... _..9 0 _ ,. A 0 ..0 6 0 0 1A rlev 0.900 w 25.20 42.33 :0 0 0 0 0 0 0 0 .1A-r1ov 0:900 w 25.20 28.50 .0 0 0 0 0 0 0 0 _ .__D 1.1D0..__. - ___ ___ _ .-_-:0.390.-w_-- `._- 10.92 ____ 10.34 ..:. =, 0 .__- -___.0 _ _. ;_ 0 ___._0 -- • -_ -- .0 _._ ,:_ ---0 - -'-- .- .0 V►I 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0 �G C 1A-00v 16X19 0md _ ,_ _ _, -_ 0.900 _ ._ 0.406 nw _ . -_ 25.20 ,_ _ 1:59 34.05 -_ 1.37 0 299 0 _ _ - 299: 0 474 0 '- _ _ _ _ 40.9 0 _ .'_ _ -_ 25 0 _ • :_ .-25 0 _ 40 0 __ _ 34 F . _ 22A tDI__ - - - - -- . -_0.989 _ . _ - 27.69 - _ 0.00 -- ---299 _ - 0 _-. _______0 _ __0 _0 25 _ ...----- fl . _ -._ __.0 _- _..-- 61 c) AED excursion 1 -152 -14 Envelope loss/gain 474 257 1 1 40 20 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 1 230 Appliances/other 2000 0 Subtotal (lines 6 to 13) 474 2717 40 250 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 14 12 0 0 14 Subtotal 488 2728 40 250 15 Duct loads 20% 16% 100 440 20% 16% 8 40 room load 524881 3155I 42 214 Air requiredal (c m) I I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -il'W wrYgt�t .oYt°' 2021-Apr-0512:23:33 r r""^ �•�' RightSuite®Universo12019 19.021 RSU08101Ac*Page6 ADocumentsUrightsoft HVAC1Vides Residence.rup Calc = MJ8 Front Door faces: W -�- wrightsoft, Right-J® Worksheet - Job: Entire House Date: Quick Calcs, Inc. By 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Closet Bath 2 Exposed wall O ft O ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 6.0 x 6.0 ft 6.0 x 6.0 ft 5 Room area 36.0 ft' 36.0 fN T y Construction U-value Or HTM Area ft' Load Area ft' Load number (Btuh/ft'= (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 13A 7 5ocs , 0,095 n ` 2.66 1.26 ; p 0 0 0 _ 0o 0 _O. 18 rlfv 0.980 n 2744, 21.83 0 0 0 0 0 0 0 0 18-r1fv_.- -. 0.980 ._ . n..: ..27.44' , . _ , - .. -0 -. _ -. o 0 . __... 0 ...._ - _ 0 0 - -0 VV 13A-7.Socs 6.095 a 2.66 _21:83 1.26 0 0 0 0 0 0 0 0 11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 1A-rtov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0 1A-r1ovd_,.__..._..... .. 13A-7 56cs - .... . ...0.900 0:095 .._<e . s ._..25.20. _.. 2.66 19.79 _. 1 26 ..._ .__9 0 _0 0 _ _ __0 0 .._..___- -0 ._.._ 0 _ .-0 0 ...-_..___ 0 A _ ., : 0 0 _ .._.-- - -0 0 1B,rtfv .. 0:980 ._. s., - 27.44 _.21:83 - 0 _ , 0 . <-_ _0 .' 0 0 0 0 0' V)/ 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0 -.,, -IAr1ov__I._. _.sw...__ 25.20 31.01 0 ......_.v,-0 0 ...- 0, .-.-, .. 13A7 5ocs. , _ :__._0.900 9.095 w 2.fi5 ._ 1:26 ._.. 0 .__ ,__.._.0 0 0. .._..__ _0._._ 0 .-_. `- 0 . 9.- -,. _. ...0. 0 0 1 A rl ov ` 0.900 - w 25.20 42.33 0 0 0 0 '" 0 0 0 -0 c 1Arlov 1.1D0-_ ..: _ __ _..__: 0.900 _.._. .:0.390-.w-- w 25:20 ----10.92 .: 28.50 _10.34.., 0 .__...,0 _. ___-.-.0 0 .___.._.,_".0 0 -.__._..._0_._.._,.___0-.-..... 0 0 0 _..__0 __... 0 ,_-0':. ,._.:_._r0. 0. 13A-7.5ocs 1A-r1ov 0.095 0.900 nw nw 2.66 25.20 1.26 34.05 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C A16X19-0md ... _ ., . _.:.:0.408 __`,. i.59 , , _.1.37, .. ._- _E36 _ ... 36 _ -_ ' .. 57, _ - _49 _. _>< _ 36 . _ . .36 _ _ _ . _ 57 _ ,-_ _.._ 49 F _ 22A-tol.___ 0.989 _ _ 27.69 0.00 _ 36 --0 .. ----o o - - - -- - -._ _ 0 . _. -- . 36 ._ ......-__0 - 0. _ .. 0. 61 c) AEC) excursion 1-3 -3 Envelope loss/gain 571 471 1 1 57 47 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 57 47 57 47 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 57 47 57 47 15 Duct loads 20% 16% 12 8 20% 16% 12 8 Total room loadAir 63I 53I 63I 53I required (cfm) I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t -* wt*Ig1�1G.ott" 2021-Apr-0512:23:33 ^" � ^° �• Right -Suite® Universal2019 19.021 RSU08101 Page r\Documents\Wrightsoft HVAC\Vides Residence.rup Calc = MJ8 Front Door faces: W -- wrightsoft, Right-M Worksheet Job: J. Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Study Foyer 2 Exposed wall 16.0 ft 8.0 ft 3 Room height 10.0 ft heat/cool 11.0 ft heat1cool 4 Room dimensions 12.0 x 12.0 ft 1.o x 100.0 ft 5 Room area 144.0 f? 100.0 ft, T y Construction U-value Or HTM I Area ' I Load I Area ft' I Load number (Btuhlf?- (St uh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/PIS Heat Cool 6 13A 7 5acs, 0.095 ' n 2 68 1:26 0 , 0 0 ` , . 0 ' ' 11 11 29 14' 41 B-rlfv , 1B r1fv, --_ 0:980 0.980 n_ n_ 27 44 27.44 21.83 21.83 % -".... ,0 , 0 . _ 0 _. _.. 0 0 ... 0 ___ _.__.____Q 0 _._-<.,Q 0 __ _ _._: 0 0 _,__....,.0 VV --._-. -- 13A-7.5ocs 0.095 _ a ... 2.66 1.26 _ 0 --- 0 0 _._ ._ _0 0 0 6 0 0 11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 1A-rlov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0 _1A-r1ovd_ __,.. _ ._-- 13A 7 5ocs -. _ .__0.900 0.095 . _e _ s .__-25.20- 2.66 19.79 1.26 _0 46 _.. __...0 40 ...._._ __0 106 _0 51 __. _._._0 11 ., _ _ 0 _ ... 0. 29 0 14 1B rlfv -1Brlfv.-,_ 0.980 01980_ , s s. 27.44 _ .27.44:,. -21.83 21.83 0-" -... :f0._.. .• 0 ..0_._.__ p 0. 0 . ..._0. 0 ;.0 '0 "0 --'0.. 0 _ _.0_..' 0 ._ 0 VVjjlI 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0 _IA-rlov _.. :_. __.__.. _--0.9.00,. sw__. 25.20 _.. 31.01 -_0_._ _ _-...0 ._ -, _0.. -.-- -._-_0 _0._ 0.._-. ..0 _. _.__._-0 _!= 13A7.5gcs, `- '0.095 w 2.66 1.26 120 . , 84 .. ;. 223 106 ,' 66 42 112 53 1Ar1ov 0.900 w 26.20 -42.33 0 0 0 0 0 0 0 0 1A rlov 0.900 w 25.20 .28.50, 36 22 907 1026 0 '0 0 0 -------- - 0.390 -_"::w._ ...._10.92 . -- -10.34 _ ;.._0 ._ ___-0 __ _; _u_0 ._ _..._._ --0 _..__. _...24 _-__... -24 --:--_-_262 _____ 248 Vjl 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0 L-G 1 A-r1 ov _ 16 0.900 0:408 nw __ -_ 25.20 . - _-1.59 34.05 % ' 1:37 _ 0 _. _ -= 144 0 .-- .: __14. _ 0 _ ;.. _ 2213 - 0 _ .-._.. 197 0 i00 0 -,. _ _.. 100. _ 0 _ _-.-159- 0 ,. _ . :137. F_. -. 22A-tDl ._ ._ _._. .__0.989 - 27.69 ,.. _ 00.0 . - , -__144 -.. _ _. 16 _ _- 443 _ . _ 0 ._.__.__.100 _., s, 6 c) AED excursion 680 -28 Envelope loss/gain 1 1908 2060 1 1 812 438 12 a) Infiltration 368 99 202 54 b) Doom ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2276 2618 1015 492 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2276 2618 1015 492 15 Duct loads 20% 16% 466 422 20% 16% 208 79 al room load 2112I 3148I 1250I 528I Airtrequi d (c m) I I I I Calculations- approved by ACCA to meet all requirements of Manual J 8th Ed. -*^ w� ilgfti_�pfY°' 2021-Apr-05 12:23:33 ---- Right-Suite®Universal 2019 19.021 RSU08101 Page ...r\Documents\Wrightsoft HVAC\Vides Residence.rup Calc = MJ8 Front Door faces: W - wrightsoft' Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Master Bedroom M Bath 2 Exposed wall 31.0 It 8.0 ft 3 Room height 11.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 14.0 x 17,0 ft 238.0 fP 1.0 x 140.0 ft 140.0 ft' T Y Construction U-value Or HTM Area ft' () Load I Area ft' I () Load number (Btuhfi (Btuh/ft') or perimeter (ft) (stuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 13A 7 5ocs; r 0,095 n ' 2.86 1.26 0 . ' 0 0 _ 0 ... U - rv0 . , 0 .-- _ ' 1 B rlfv 0980 n- . 27.44 21.83 0 0 0 0 0 0 0 0 -G �-G .18 rliv._ ,- ` .. _- 13A-7.50cs _ 0;980 0.095 _ n._ a 27.44 2.66 ,._ . 21.83 1.26 _. 0 154 Q 100 -4 266 - _Q 126 __o........ 0 _D 0 - g 6 - _-q 0 11 1 A-rl ov 0.900 a 25.20 42.33 36 0 907 1524 0 0 0 0 1 A-rl ov 0.900 a 25.20 19.79 18 18 454 - 356 0 0 0 0 1 A r1 ovd 13A 7 5ocs 0 900 0.095 _e , s . 25.20 2.66 19 79 1.26 _ 0 187 0 187 0 497 _ 0 236 0 80 _0 64 - 0 . 170 0 _ 81 1 B-rl fv 1 B rliv _ „ _ _ O' 980 _-.-0:980,e , s s`_' 27 44 .,._.2744':-. 21 83 21.83`.. '. - 6 -:A 0 ._.. 0-. 0 -_ 0. 0 -_.__.-_0 16 ._,.____.-0 16 .__ __ .0.,__-...-._0 439 '349 ._....0. Vy 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0 _ 1 A, ov , - _. . _ _.., _ _...-._ 0.900 _ -sw _25.20 25.20. _ 31.01 0 4 0 0 13A 7.5ocs, 0.695 w _ 2.66 1.26 _ _ ._..4 6 0 - ._0 0 -- --._0 0� . __..._ _._ 0 -, . _ '0 ..__. __ 0 _ .. - 0 ID 1A rlov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 1A rlov 0.900. w 25.20 28.50 . 0 0--. 0 0 0 0 0 0' .11D0 .._.. w._ _. 10.92 ._.�.'_10.34 .. _ ._.0 ., .,, ___ _0 ___ .. _T_--0._.0------ 0 ... _ ._.__ 0 __- _. _ __0 ..._ .__ :0, W 13A-7,5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0 1A-r1ov 0.900 nw':. 5.20 C.:.. ':16X19Omd..,e:_;. -_........0'408 .�1.59 31.3Z'_ _ _.230 .-.-.._238 .__.,>..:'37,7 . __.._B26 :- _.140._.. 140 ;__- _..222..__ _ ..192, 22A tol- --. ...._,._. - ._. _0.969 _ - ..._._ .27.69 .. ,_..,-0.00 - - 238 . _. _..._ 31. _ . _B66 .. __.. _ _.. 0 _..._. _ 140 -_.-.. - 8 222 - 0 6 c) AED excursion 1 -172 -48 Envelope loss/gain 3360 2396 1053 574 12 a) Infiltration 784 210 184 49 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 4144 3066 1237 853 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4144 3066 1237 853 15 Dud loads 20% 16% 849 494 20 % 16% 253 138 I requTotl ir 42039931 31745601 1461 991 dIoad (dm) I Air I I I I I I 48I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr'tghpYt 2021-Apr-0512:23:33 A96K Rlght.Suite®Universal 2019 19.021 RSUD8101 Page ...r\Documents\Wdghtsoft HVAC\Vides Residence.rup Calc = MJ8 Front Door faces: W -t' - wrightsoft• Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name M Toilet M WIC 2 Exposed wall 4.0 It 6.0 It 3 Room height 10.0 It heat/cool 10.0 It heat/cool 4 Room dimensions 7.0 x 4.0 ft 14.0 x 6.0 it 5 Room area 28.0 ft2 84.0 ft2 Ty Construction U-value Or I HTM I Area (ft2) I Load I Area (ft2) I Load number (Btuhlft'- F (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Coal 6 13A 7 5ocs,0.095 in 2 66 1 26 0 0 0 0 0 0 0 0 {-C _ 1841fv 18r1fv...- ' - ._.r. 0980 -0980_n.' n 2744, ,..2744'._.._2183. 2183 0 ._ 0 �._. 0 `' u 0 �.'-_. 0 -D 0 o 01 .-. 0 0 13A-7.5ocs 0.095 a 2.66 1.26 ..0 0 0. 0 0 - 0 _ ._ 0 _ 0 _.-...-.R 0 11 IA-rlav 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 IA-rlov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0 r ov 0 00 e.- 25.20 _ 19.79 0 0 0 _ 0 0_ 0 13A 7 5ocs 0.095 s 2.66 : 1.26 . 40 40 106 51 1 60 60 6 180 76 6 i 13 rlfv 98rlfv-_ - 0.095 _._0.980 s `.s.. 27 44 __.2744' - 21 83 ` __.21.83' A __-0 _ ._ 0 0 ._ 0 _.�._ 0.__.�.:__ 0 -0 0 _..::. 0. -0 0 0 _. ._- 0 - 0: try 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0 1A r1ov 13A 7 5oc5 0.900 0.095 __ sw w .... 25.20 2.66 .. ..31.01 '126 . „ ._0 0 0 0 :... 0 0 . _,_.._ - 0 0 0 '- - 0` .. 0 0 0 0 �---G 1A rlov 0.900 w 25.20 42.33 0 0 0 0' 0 0 -0 .0 1-G .1 A-rl ov 0.900 .w 25.20 28.50 : 0 0 0 0 0 0 0 0 . __D II DO -' __ _ ._ _ .___:. , ._ _..0.390 ,:_w._ : _= 10.92 ._:,.. _10.34 •_ __, ,?_0 __._ __. _'-0 .__ . ,___-..0 __ - ..._0 _-_- .... 0 .__ . _ 0 ,_. _ .-..-0 0: 11� 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0 G� 1A-rlov 0.900 nw 25.20 34.05 0 0 0 0 0 0 0 0 ._ F _ -- _ I6X79 ., 22A-tol._. .._ 0.989 _,. . .-.__ . 59 .-__.27,59 _ .,_ _ 0.00 .. 2 .,__. 4_ __ . 111 ,_.._ _0 ._..-.__. - 84 _.. 6_ ....330,40 _..166_ .115C _ .. s• 61 c) AED excursion -6 -12 Envelope loss/gain 262 83 1 1 459 179 12 a) Infiltration 92 25 138 37 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 354 107 597 216 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 354 107 597 216 15 Duct loads 20% 16% 72 17 20% 16% 122 35 room 4261 1211 7I 25IAirreqim) (cf I I I 17 6 I I 29 2 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ^VI&- wrlght-:oft 2021-Apr-0512:23:33 A 6 ^^ o.• Pig htSuite@Univenzal201919.021 RSUD8101 Page10 rlDocumentslWdghtsoft HVACIVides Residence.rup Calc = MJ8 Front Door faces: W wrightsoft3 Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcaics@aol.com 1 Room name Closet 3 Bath 3 2 Exposed wall 0 ft 9.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 6.0 36.0 f? ft 1.0 78.0 ft' x 78.0 ft Ty Construction U-value Or HTM Area (ft') I Load Area (ft') I Load I number I (Btuh/ft.= (Btuhfft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A 7 5ocs 1B-rlfv 0.095 0.980 n, ' n; 2.66 27.44 1 26 21.83 0 -0 - 0 k 0 ' ' 0 0 0 ;` 0 0 _.. "0 0 0 0- -6 ' 0 80 -_n_. .. _27.44 2183 , . u,., 0 .. , . 0 -F 0 __..A �, 0 R _ 0 13A 7 5ocs 0.095 a 2.66 1.26 0 0 0 ._. 0 _..: _..-. _ 0 _ ...._ 0 _. _,_ _. 0 --~' 0 11 1A rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 1A rlov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0 1A rlovd _ _ 0.900 - e - 25.20 19.79 0 0 0 0 0 0 0 13A 7 5om 0.095 s 2.66 1.26 __0 0 _ 0 0 0 _._ g0 -. 82 218 104 ;Vrllr�_? ! 18rtfv :1&rlfv__•-__ ._.._- 0.980 ___ 0980_s_: s, 27.44 .,27.44 21.83 -_.21:83... 0 _0 0 __0, 0 -,R_0 0 _ .....0 0 __._8--_ 0' --,8_-220 0 0 175. 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0 _-,.._.-1A-r19v __... 13A-7 5ocs ..-.v...,0.900_..s`N.. 0.095 w ...... 25.20___.,31.01.._...-,TO 2.66 4.26 0 0.._..-- 0 0 0 _...._-0,..., 6 0 0_.._.. 0 -0. 0 0 1. 0 1A r1ov, 0.900 w 25.20 -42:33 0 0 0 0 0 0 0 0. 1Arlov_ '4+ 0.900 w 2$:20 28:60 0 0 -01 0 "0 0 0 -D .11D0__=. _ -. _.__ - --_.6.390--_w----_ _10.92 ..._ 10'34 _ '_0 _ .c:._.- .O ',_. 0 ------- 0._-_ .__ ._0 _ _ __;0:_.__. _,_.0 _ __'_0. 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0 0.900 nw, _. 0 0. 0 0 0 C - : ;16X19-Omd_ _ . _ :. _ . 0.408 - .:-_ _25.20 - _ 1.59 .__ -34;05 -. _._ 1.37 _ ' _. 36 _ __ - m_ - 36 _ _.. -_. _` .. __ .57 - _ _ _49 _..---_- . _. -. _. 76 _ _ _._._0._.-,-- .__ .: _ _.. 78 _ ._O, _- ._ :-124% 107 F..._ ..22Atol,-,._ 0.989 .,,.. 27.-69 0,00._...__36 O __.,......0 9. .-.-,...7 .9-._.._._249 -- cO. 6 c) AED excursion 1-31 -23 Envelope loss/gain 57 47 1 1 811 362 12 a) Infiltration 0 0 207 55 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 57 47 1017 417 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 57 47 1017 417 15 Duct loads 20% 16% 12 8 20% 16 % 208 67 Total room load ggl 541 12261 4841 Air required (cfm) I I I 3 3 I I 50 24 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. L wrlgtft�oYt" 2021-Apr-0512:23:33 •� .. �� RightSuite@ Universal 2019 19.021 RSU08101 Page 11 ADocuments\Wrightsoft HVAC\Vides Residence.rup Calc = MJ8 Front Door faces: W - wrightsoft• Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane. Fort Pierce. FL 34946 Phone: 772-466-6799 Email: ouickcaics0aol.com i 1 Room name Bedroom 3 2 Exposed wall 33.2 ft 3 Room height 10.0 ft heat/cool 4 Room dimensions 1.0 x 197.0 ft 5 Room area 197.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area Load number (Btuh/ft'= (Btuh/ft') or perimeter (ft) (Btuh) or perimeter Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 " 13A 7 5ocs 0.095 n 2 66 1.28 , 40 40 ^1 D6 51 1B r1fv 1B7r1fv _ _. 13A-7.5acs 0.980 . 0.980 0.095 n• ,._n a 2744.1 . 27.44. 2.66 21 83 ,2183 1.26 ^0 _ ..0 0 0 . _ ._ _- 0 0 0 _0 0 0 _...._- 0 11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 1 A-rl ov 0.900 a 25.20 19.79 0 0 0 0 1A (lovd 0.900 e _ . 25.20 _ 19.79 0 0 0 0 19A 7 5ocs , 0.095 - s 2,66 126 120 120 319 152 1B-r1fv 18 r1fv - ,y..,_ . .._ `` 0.980 _ . _ . 0.980 s .` s. 2744., .. _ 27 44' 21.89 .. _ 21'.83 0 , ... _ 0 0 ... . - _' ..0 0 . __ . _.. _0 0 .-_.W.:.. _ 0 „ y! 13A-7.5ocs 0.095 sw 2.66 1.26 36 25 67 32 --'- _-O. 1A-r1ov _: 13A 7.5acs , . ,. __. 0.900. 0:095 sw w -.. 25.20 2.66 ..._31.01 1.26 _.._.�1 100 _ ,F 2 64 277 170 _•__ 341„ . 81 y - 1A rtov .6.900 w 25.20 42.33 36 0 907 1524 - 1A-r1ov 0.900 w 25.20 ` 28.50 0 0 0 0_ _____D.11D0,._:_ .___ ..... __-..0:390..,.w...__..10.92_ _-10.34 0., .._'.-0 :__',. �_0',_.._0__-_._ :,.., _._.._.__._:. _..__:_. .._.. '_ 13A-7.5ocs 0.095 nw 2.66 1.26 36 25 67 32 1 V0ov 0.900 nw 25.20 34.05 11 0 277 375 C 16X19-0md:'. 0.408 ,..-- _T59 _ _ 1:3Z 197 _ _ _ 197 _ .. ., 312 :._ _ _ 270 F,_ 22A401_--.. ... _,.._. >. 0.9.89.- _. - 27.6.9 _...__0.00 197 . --33 91_8 0 61 c) AED excursion 644 Envelope loss/gain 3422 3500 12 a) Infiltration 763 204 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 1 230 Appliances/other 0 Subtotal (lines 6 to 13) 4185 3934 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 4185 3934 15 Duct loads 20% 16% 857 634 room load 5205I 568 4223I ATotl ir requi d (cfm) I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrlgi�tzotY#^ RightSuite®Universal 2019 19.022021-Apr-0512:23:33AM 1 RSU06101 Page12 r%Documents%Wdghtsoft HVAC1Vides Residence.rup Cale = MJB Front Door faces: W