Product Annroval Menu > Produd or Aoolicatlon S7FFL170722-R9
>Ap
FL # Application type Revision
Code Version 020
Application Status pproved
Florida Building Code Online
Comments
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
fivalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By James R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL17022 R9 COI 26ga VMAX pjywood&df
Standard
Year
TAS 100
1995
TAS 125
2003
UL 580
2006
Sections from the Code
https://floddabuilding.org/prlpr app_dtl.aspx7param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2b7ZBOgjsB2joMvlulBgwLyA%3d%3d 1/3
5/19/2021
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
12/16/2020
12/16/2020
12/26/2020
02/09/2021
FL # Model, Number or Name Description
17022A 01: 26ga VMax on Plywood 26ga (min) VMax 5V panel with 24" coverage on 15/32" (min)
plywood or 3/4" (min) thick wood plank.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R9 II 26ga VMAX .. wood.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-228 Evaluation Reports
Other: Refer to evaluation report. FL17022 R9 AE 26ga VMAX oiywood.p,&
Created by Independent Third Party: Yes
17022.2
02: 032 Aluminum VMax on Plywood
Nominally 0.032" aluminum (or thicker) VMax 5V panel with
21" coverage on 15/32" (min) plywood or 3/4" (min) thick
wood plank.
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL17022 R9 II 032 VMAX 21in nI ood.Ddf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-168.5
Evaluation Reports
Other: Refer to evaluation report,
FL17022 R9 AE 032 VMAX �iin R ywood.p�f
Created by Independent Third Party: Yes
17022.3
03: 26ga VMax on Plywood
269a (min) VMax 5V panel with 24" coverage on 15/32" (min)
plywood or 3/4" (min) thick wood plank. Option for fasteners in
the flats and In the ribs.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R9 II 26ga VMAX Diywood flats.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-114.25
Evaluation Reports
Other: Refer to evaluation report.
FL17022 R9 AE 26ga VMAX plywood flats.ps_jf
Created by Independent Third Party: Yes
17022.4
04: 26ga CorMax on Plywood
26ga (min) CorMax corrugated panel with 29.5" coverage on
15/32" (min) plywood or 3/4" (min) thick wood plank.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL17022 R9 II 269a CorMax Plywood HVHZ.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161
Evaluation Reports
Other: Refer to evaluation report.
FL17022 R9 AE 26oa CorMax Plywood HVHZ.odf
Created by Independent Third Party: Yes
17022.5
05: 26ga CorMax on Battens
26ga (min) CorMax corrugated panel with 29.5" coverage on
2x4 (min) battens,
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R9 II 26ga CorMax Battens.pjd
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161
Evaluation Reports
Other: Refer to evaluation report.
FL17022 R9 AE 269a CorMax Battens.
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. o right 2007-2013 State of Florida.:; Prlvaa Statement ;: Accesslbllity Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls
https://flohdabuilding.org/prlpr app otl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoRa/o2b7ZBOgjsB2joMvlu[8gwLyA%3d%3d 2/3