Home
My WebLink
About
Project Information
h Duct System Summary Job. r wrightsoft - �-� Entire House g�RERV o Byte: Quick Calcs, Inc. JUN 0 S 2021 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com L r I nr le COUntY. Permitting Project Information For: Jose & Lisa Vides, Lot 2 Johnson Road Fort Pierce, FL 34951 External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.250 in/100ft 1383 cfm 200 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.250 in/100ft 1383 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bach h 69 3 3 0.356 4.0 Ox0 VIFx 25.4 115.0 st3 Bath 2 h 1287 52 26 0.307 5.0 Ox 0 VIFx 27.7 135.0 st7 Bath 3 h 1226 50 24 0.251 5.0 Ox 0 VIFX 44.5 155.0 st6 Bedroom 2 h 4448 181 121 0.301 8.0 Ox 0 VIFX 31.3 135.0 st7 Bedroom 3 C 4568 205 223 0.251 8.0 Ox 0 VIFX 44.2 155.0 st6 Closet h 69 3 3 0.371 4.0 Ox 0 VIFX 19.8 115.0 st3 Closet 3 h 69 3 3 0,250 4.0 OX 0 VIFx 45.0 156.0 st6 Family Room C 3084 149 150 0.327 8.0 Ox 0 VIFx 37.7 115.0 st1 Family Room -A C 3084 149 150 0.324 8.0 Ox 0 VIFX 39.6 115.0 st1 Foyer h 1223 50 28 0.298 5.0 OX0 VIFx 32.7 135.0 st5 Kitchen c 3168 24 155 0.338 8.0 Ox 0 VIFX 32.9 115.0 st1 Laundry C 1303 53 64 0.392 6.0 Ox0 VIFX 12.7 115.0 st4 M Bath h 1490 61 48 0.313 6.0 Ox 0 VIFX 44.7 115.0 st2 M Toilet h 426 17 6 0.306 4.0 Ox 0 VIFX 48.1 115.0 st2 M Wic h 719 29 12 0.308 4.0 Ox 0 VIFx 47.1 115.0 st2 Master Bedroom h 4993 203 174 0.304 8.0 Ox 0 VIFX 49.4 115.0 st2 Mud Room c 339 4 17 0.366 4.0 Ox 0 VIFX 21.6 115.0 st3 Pantry . h 86 4 3 0.372 4.0 Ox 0 VIFx 19.5 115.0 st4 Sate Room c 290 2 14 0.379 4.0 Ox 0 VIFX 17.0 115.0 st3 Study c 3040 112 148 0.297 7.0 Ox 0 VIFx 33.4 135.0 st5 Toilet 2 h 46 2 2 0.297 4.0 Ox 0 VIFx 33.5 135.0 st7 WIC 2 h 673 27 10 0.386 4.0 Ox 0 VIFx 14.4 115.0 st4 wriahtsoW 2021-Apr-0512:23:35 ..,.,v. , ....: RightSuite@Universal 2019 19.021 RSU08101 Page 1 AM-ADocuments\Wrightsoft HVACWides Residence.rup Calc = MJ8 Front Door faces: W Name Trunk Type Htg (Cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st2 Peak AVF 311 240 0.304 570 10.0 0 x 0 VinlFlx st6 Peak AVF 258 249 0.250 584 9.0 0 x 0 VinlFlx st5 st5 Peak AVF -420 425 0.250 542 12.0 0 x 0 VinlFlx st3 st3 Peak AVF 432 461 • 0.250 587 12.0 0 x 0 VinlFlx st1 Peak AVF 321 455 0.324 580 12.0 0 x 0 VinlFlx st7 Peak AVF 235 149 0.297 533 9.0 0 x 0 VinIFIX st4 st4 Peak AVF 320 226 0.297 586 10.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg _ (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1383 1383 0 0 0 0 Ox 0 VIFx wrightsoft, 2021-Apr-0512:23:35 ^�/�•* .., ,�, M..ti, ?..,, RightSuite® Universal 2019 19.021 RSU08101 Page 2 ...r\Documents%Wrightsoft HVAC\Vides Residence.rup Calc = MJ8 Front Door faces: W