Entire House g�RERV o Byte:
Quick Calcs, Inc. JUN 0 S 2021
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com L r I nr le COUntY. Permitting
Project Information
For: Jose & Lisa Vides, Lot 2 Johnson Road
Fort Pierce, FL 34951
External static pressure
Pressurelosses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50 in H2O
0 in H2O
0.50 in H2O
0.250 / 0.250 in H2O
0.250 in/100ft
1383 cfm
200 ft
Cooling
0.50 in H2O
0 in H2O
0.50 in H2O
0.250 / 0.250 in H2O
0.250 in/100ft
1383 cfm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bach
h 69
3
3
0.356
4.0
Ox0
VIFx
25.4
115.0
st3
Bath 2
h 1287
52
26
0.307
5.0
Ox 0
VIFx
27.7
135.0
st7
Bath 3
h 1226
50
24
0.251
5.0
Ox 0
VIFX
44.5
155.0
st6
Bedroom 2
h 4448
181
121
0.301
8.0
Ox 0
VIFX
31.3
135.0
st7
Bedroom 3
C 4568
205
223
0.251
8.0
Ox 0
VIFX
44.2
155.0
st6
Closet
h 69
3
3
0.371
4.0
Ox 0
VIFX
19.8
115.0
st3
Closet 3
h 69
3
3
0,250
4.0
OX 0
VIFx
45.0
156.0
st6
Family Room
C 3084
149
150
0.327
8.0
Ox 0
VIFx
37.7
115.0
st1
Family Room -A
C 3084
149
150
0.324
8.0
Ox 0
VIFX
39.6
115.0
st1
Foyer
h 1223
50
28
0.298
5.0
OX0
VIFx
32.7
135.0
st5
Kitchen
c 3168
24
155
0.338
8.0
Ox 0
VIFX
32.9
115.0
st1
Laundry
C 1303
53
64
0.392
6.0
Ox0
VIFX
12.7
115.0
st4
M Bath
h 1490
61
48
0.313
6.0
Ox 0
VIFX
44.7
115.0
st2
M Toilet
h 426
17
6
0.306
4.0
Ox 0
VIFX
48.1
115.0
st2
M Wic
h 719
29
12
0.308
4.0
Ox 0
VIFx
47.1
115.0
st2
Master Bedroom
h 4993
203
174
0.304
8.0
Ox 0
VIFX
49.4
115.0
st2
Mud Room
c 339
4
17
0.366
4.0
Ox 0
VIFX
21.6
115.0
st3
Pantry .
h 86
4
3
0.372
4.0
Ox 0
VIFx
19.5
115.0
st4
Sate Room
c 290
2
14
0.379
4.0
Ox 0
VIFX
17.0
115.0
st3
Study
c 3040
112
148
0.297
7.0
Ox 0
VIFx
33.4
135.0
st5
Toilet 2
h 46
2
2
0.297
4.0
Ox 0
VIFx
33.5
135.0
st7
WIC 2
h 673
27
10
0.386
4.0
Ox 0
VIFx
14.4
115.0
st4
wriahtsoW 2021-Apr-0512:23:35
..,.,v. , ....: RightSuite@Universal 2019 19.021 RSU08101 Page 1
AM-ADocuments\Wrightsoft HVACWides Residence.rup Calc = MJ8 Front Door faces: W
Name
Trunk
Type
Htg
(Cfm)
Clg
(cfm)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
st2
Peak AVF
311
240
0.304
570
10.0
0 x 0
VinlFlx
st6
Peak AVF
258
249
0.250
584
9.0
0 x 0
VinlFlx
st5
st5
Peak AVF
-420
425
0.250
542
12.0
0 x 0
VinlFlx
st3
st3
Peak AVF
432
461
• 0.250
587
12.0
0 x 0
VinlFlx
st1
Peak AVF
321
455
0.324
580
12.0
0 x 0
VinlFlx
st7
Peak AVF
235
149
0.297
533
9.0
0 x 0
VinIFIX
st4
st4
Peak AVF
320
226
0.297
586
10.0
0 x 0
VinlFlx
Name
Grille
Size (in)
Htg
(cfm)
Clg _
(cfm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
Ox0
1383
1383
0
0
0
0
Ox 0
VIFx
wrightsoft, 2021-Apr-0512:23:35
^�/�•* .., ,�, M..ti, ?..,, RightSuite® Universal 2019 19.021 RSU08101 Page 2
...r\Documents%Wrightsoft HVAC\Vides Residence.rup Calc = MJ8 Front Door faces: W